1.Research of Subtype A Caused by New A Allele Mutation
Li-Ping ZOU ; Fang QIU ; Jian-Shuo LIU ; Zhi-Peng WU ; Feng-Qing ZHANG ; Ying ZHU
Journal of Experimental Hematology 2025;33(6):1765-1768
Objective:In order to clarify the ABO phenotype and genotype,and explore the molecular biological mechanism,serological detection,genotyping and gene sequencing were performed on an upper gastrointestinal hemorrhage patient with inconsistent forward and reverse ABO blood typing.Methods:ABO forward and reverse blood typing,H antigen identification,capillary centrifugation test and salivary substance detection were performed by classical serological method,moreover,polymerase chain reaction-sequence specific primer(PCR-SSP)was used for ABO genotyping,ABO gene 1-7 exons were sequenced by Sanger analysis in order to identify mutation.Results:Mixed field agglutination with anti-A,anti-AB and no agglutination with anti-A1 were appeared in the forward typing tests,agglutination with B cells but no agglutination with A1 cells and O cells were appeared in the reverse typing tests.3+agglutination strength was showed with anti-H.In capillary centrifugation experiment,erythrocyte after isolation in proximal part and distal end had same strength of agglutination with anti-A.Substances A and H were detected in saliva.The patient was assigned an A3 phenotype according to serological characteristics.Sequencing results of ABO gene 1-7 exons showed c.261delG,c.467C>T,c.865A>G,in which,865A>G was the first discovered mutation,and this new mutation had been submitted to GenBank with accession number PP187306.Conclusion:A novel site mutation c.865A>G is reported in this study,and this new mutation can result in a replacement of Met with Val at residue 289(p.Met289Val)and lead to an A3 phenotype.
2.Correlation analysis between weakness and readmission of elderly patients with chronic heart failure in vulnerable period
Lanqing HUANG ; Xiaoqin QIU ; Chunhan LAN ; Li ZHANG ; Xiaodong JIANG ; Jiemei ZHENG ; Fang LIU
China Modern Doctor 2025;63(30):26-29,81
Objective To investigate the relationship between frailty and readmission during vulnerable periods in elderly patients with chronic heart failure.Methods Using convenience sampling method,290 elderly patients with chronic heart failure admitted to Department of Cardiovascular,the People's Hospital of Guangxi Zhuang Autonomous Region from December 2022 to August 2023 were selected as the research subjects.They were followed up for three months and surveyed using general information questionnaire,frailty scale,and Barthel index.Results Spearman correlation analysis showed a positive correlation between readmission during the vulnerable period and frailty(r=0.266,P<0.05).The readmission rate during the vulnerable period was 28.6%,and the results of multivariate Logistic regression analysis showed that frailty(OR=2.561,95%CI:1.409-4.654),age(OR=1.113,95%CI:1.067-1.161),and renal dysfunction(OR=2.903,95%CI:1.559-5.406)were independent risk factors for unplanned readmission during the vulnerable period in elderly patients with chronic heart failure.Conclusion There is a positive correlation between frailty and readmission during the vulnerable period in elderly patients with chronic heart failure.Frailty,age,and renal dysfunction are independent risk factors for decompensated admission events in vulnerable elderly patients with chronic heart failure.
3.Systematic review of a body image assessment tool for burn patients
Ning LIU ; Jingling LI ; Shunli ZUO ; Xiuyuan ZHU ; Yiping FANG ; Lihong QIU
Chinese Journal of Nursing 2025;60(4):478-486
Objective The measurement characteristics of body image specificity evaluation tools for burn patients were systematically evaluated,aims to provide reference for selecting appropriate assessment tools.Methods CNKI,Wanfang data knowledge service platform,VIP database,China Biomedical Literature Service system,PubMed,Embase,Web of Science,PsycINFO and CINAHL were searched by computer to collect and evaluate the measurement characteristics of burn patients'body image specificity evaluation tools from the establishment of the database to April 15,2024.There were 2 researchers who independently reviewed the collected literature,looked for the full text and extracted information.At the same time,the methodological quality and measurement performance of such assessment tools were systematically evaluated under the guidance of consensus-based standards for the selection of health measurement instrument(COSMIN)guidelines.Finally,the quality and strength were rated to form a recommendation.Results A total of 6 studies were included,including 3 evaluation tools for body image specificity of burn patients,namely the Body Image Quality of Life Inventory into Brazilian Portuguese(BIQLI-BP),Satisfaction with Appearance Scale(SWAP),and the Derriford Appearance Scale 59(DAS59).In the development of PROMs,the overall quality of BIQLI-BP,SWAP and DAS59 is"doubtful".In terms of content validity,the methodological quality of BIQLI-BP,SWAP and DAS59 was evaluated as"doubtful".In terms of construct validity,the methodological quality of SWAP and DAS59 was evaluated as"good"and"very good"respectively,while the methodological quality of BIQLI-BP was"inadequate".In terms of internal consistency,the methodological quality of BIQLI-BP,SWAP and DAS59 was"very good".In terms of stability,the BIQLI-BP and DAS59 were"unreported",and the methodological quality evaluation of the SWAP was"doubtful".In terms of criterion validity,the BIQLI-BP and DAS59 scales were"unreported",and the methodological quality evaluation of the SWAP scale was"inadequate".In terms of measurement errors,the BIQLI-BP and DAS59 scales were"unreported",and the methodological quality evaluation of the SWAP scale was"doubtful".In the aspect of hypothesis test,except that the DAS59 scale is"unreported",the methodological quality of BIQLI-BP scale is"very good"and the evaluation of SWAP scale is"doubtful".Conclusion Among the existing body image specificity evaluation tools for burn patients,the SWAP has good measurement performance and it can be recommended for the time being.The number of specific evaluation tools for body image of burn patients in China is relatively insufficient,and more localization studies should be carried out in the future.
4.Research of Subtype A Caused by New A Allele Mutation
Li-Ping ZOU ; Fang QIU ; Jian-Shuo LIU ; Zhi-Peng WU ; Feng-Qing ZHANG ; Ying ZHU
Journal of Experimental Hematology 2025;33(6):1765-1768
Objective:In order to clarify the ABO phenotype and genotype,and explore the molecular biological mechanism,serological detection,genotyping and gene sequencing were performed on an upper gastrointestinal hemorrhage patient with inconsistent forward and reverse ABO blood typing.Methods:ABO forward and reverse blood typing,H antigen identification,capillary centrifugation test and salivary substance detection were performed by classical serological method,moreover,polymerase chain reaction-sequence specific primer(PCR-SSP)was used for ABO genotyping,ABO gene 1-7 exons were sequenced by Sanger analysis in order to identify mutation.Results:Mixed field agglutination with anti-A,anti-AB and no agglutination with anti-A1 were appeared in the forward typing tests,agglutination with B cells but no agglutination with A1 cells and O cells were appeared in the reverse typing tests.3+agglutination strength was showed with anti-H.In capillary centrifugation experiment,erythrocyte after isolation in proximal part and distal end had same strength of agglutination with anti-A.Substances A and H were detected in saliva.The patient was assigned an A3 phenotype according to serological characteristics.Sequencing results of ABO gene 1-7 exons showed c.261delG,c.467C>T,c.865A>G,in which,865A>G was the first discovered mutation,and this new mutation had been submitted to GenBank with accession number PP187306.Conclusion:A novel site mutation c.865A>G is reported in this study,and this new mutation can result in a replacement of Met with Val at residue 289(p.Met289Val)and lead to an A3 phenotype.
5.Investigation on ventilator use and management in secondary and tertiary medical institutions in Sichuan Province
Zheng-hua LIANG ; Si-mei WANG ; Qiu-yu LIU ; Jin-long XU ; Ze-fang LIU ; Dan WEN
Chinese Medical Equipment Journal 2025;46(3):75-80
Objective To investigate the current situation of the ventilator use and management in secondary and tertiary medical institutions in Sichuan Province to provide references for management and training of ventilator users.Methods A questionnaire survey involving in 235 nurses from 13 secondary and tertiary medical institutions in Sichuan Province was conducted in terms of general information of the respondents,pipeline connection and parameter setup of ventilators,cleaning,sterilization and maintenance of ventilators,identification and treatment of ventilator alarms and hospital-acquired infection prevention and control.Results The results showed 20.4%of the respondents were nurses from critical care departments,and 79.6%of the respondents underwent the training for using the ventilator in their department;91.9%of the respondents could conduct ventilator self-testing by connecting the simulated lungs after the ventilator was switched on;66.4%of the respondents indicated that the initial parameters of the ventilator were set by the doctor;60.9%of the respondents proved that the performance monitoring and routine maintenance of the ventilator were carried out by the nurse;63.4%of the respondents showed disposable lines were commonly used in the departments.There were 89.8%of the respondents said the daily sterilization and management of the ventilator were performed by the nurse;46.0%of the respondents expressed the external surface of the ventilator was disinfected mainly with gamma disinfectant wipes;44.7%of the respondents indicated the external surface of the ventilator was sterilized every day;48.5%of the respondents said the internal airway of the ventilator was disinfected;57.0%of the respondents proved the disinfection was conducted after the expiratory flow sensors were used by any patient.There were 74.5%of the respondents that had paid attention to the ventilator waveform,and by the ventilator waveform only 21.3%were correct in determining whether there was secretion or fluid in the circuit and 22.1%in clarifying whether there was air leakage in the circuit.There were 59.1%of the respondents indicated that the closed suction tube was replaced once every 24 h;71.1%of the respondents could perform airbag pressure monitoring by the special pressure gauge.Conclusion Most of the nurses from secondary and tertiary medical institutions in Sichuan Province can use ventilators correctly,who have problems in disinfection specifications,infection prevention and control or recognition of ventilation waveform.It's suggested the training be strengthened to enhance the clinical nursing staffs in ventilator management.[Chinese Medical Equipment Journal,2025,46(3):75-80]
6.The mediating effect of electrocardiographic indicators in the association between exposure to fine particulate matter and its element constituents and blood pressure
Yu WANG ; Wenwen ZHANG ; Qian LIU ; Huiting LING ; Changzhen XIANG ; Yiqi QIU ; Chen CHEN ; Jiaonan WANG ; Jianlong FANG ; Xiaoming SHI
Chinese Journal of Preventive Medicine 2025;59(5):621-627
Objective:To evaluate the mediating effect of electrocardiographic (ECG) indicators in the association between short-term exposure to fine particulate matter (PM 2.5) and blood pressure and to explore the key PM 2.5 element constituents that produce the mediating effect. Methods:Based on a cross-sectional survey across 10 cities in the Beijing-Tianjin-Hebei region and surrounding areas, PM 2.5 and its element constituents were collected from the nearest air monitoring superstation. Blood pressure and ECG indicators of participants were obtained through physical examinations. A multivariate linear regression was used to evaluate the effect of short-term exposures to PM 2.5 on blood pressure. A mediation analysis was used to identify the mediating effect of ECG indicators in the association between exposure to PM 2.5 and its element constituents and blood pressure. Results:The age of the 1 793 participants was (65.1±13.3) years, and 885 (49.4%) were males. During the study period, the daily mean concentration of PM 2.5 was (70±45) μg/m 3, and the systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP) and pulse pressure (PP) were (139±20), (82±11), (101±13), and (57±17) mmHg (1 mmHg=0.133 kPa), respectively. The results of the multivariate linear regression showed that for every 10 μg/m 3 increase in PM 2.5 on the same day (lag 0), DBP increased by 0.15 (95% CI: 0.02-0.28) mmHg, and PP decreased 0.18 (95% CI: 0.36-0.01) mmHg. The exposure to 14 elemental constituents, such as Ga, Co and Se, was associated with an increase in DBP, while the exposure to 17 elemental constituents, such as Cs, Se and Ag, was associated with a decrease in PP. At lag 0, the PM 2.5-induced increase in DBP was mediated by the QRS interval (mediation percentage of 18.98%), and the PM 2.5-induced decrease in PP was mediated by the QT interval (mediation percentage of -6.31%). The exposure to K, Br, Pb, Zn, Ca, Co, Pd, Cu, and As constituents was associated with increases in DBP mediated by prolonged QRS interval. The exposure to Pb, Zn, K, and As constituents was associated with decreases in PP mediated by prolonged QRS interval. Conclusion:ECG indicators such as QRS interval may mediate the association between short-term exposure to PM 2.5 and its element constituents and blood pressure.
7.Investigation of effects of petroleum ether fraction from Derris eriocarpa on glucose and lipid metabolism in a mouse model of metabolic syndrome via ATF3/HNF4ɑ/CYP7A1 pathway
Jing YAN ; Jie WENG ; Xuan ZHANG ; Xue LI ; Chao-nan KONG ; Hong-cun LIU ; Li-fang YANG ; Ming-guo JIANG ; Qiu-yan LIANG ; Li-ting HE
Chinese Traditional Patent Medicine 2025;47(9):2902-2911
AIM To investigate effects of petroleum ether fraction from Derris eriocarpa How on glucose and lipid metabolism in a mouse model of metabolic syndrome(MS).METHODS KM mice were fed a high-fat diet and administered streptozotocin intraperitoneally to establish MS models.The MS mice were then randomly assigned to the model group,the metformin hydrochloride group,the lovastatin group,the ursolic acid group,and the high-,medium-and low-dose D.eriocarpa petroleum ether fraction groups,with 10 mice in each group.Ten additional mice maitained on a normal diet served as the normal control group.After 4 weeks of intragastric administration,glucose and lipid metabolism indicators were measured.Hepatic pathological changes were assessed using HE staining and oil red O staining.Liver tissue mRNA expressions of ATF3,PEPCK,FXR,CYP7A1,HNF4ɑ,CYP8B1 and SRB1 were quantified by RT-qPCR.Hepatic protein expressions of ATF3,HNF4ɑ,PEPCK,FXR and CYP7A1 was analyzed by Western blot in MS mice.RESULTS Compared to the model group,the high-dose D.eriocarpa petroleum ether fraction group exhibited significant glucose tolerance improvement(reduced OGTT-AUC,P<0.01);favorable serum lipid modulation in terms of increased HDL-C levels(P<0.01)and decreased TG,TC,LDL-C(P<0.01);reduced renal biomarkers(BUN,SCR)and hepatotoxic indicators of TBA,AST and ALT activities(P<0.01);alleviated hepatic lipid accumulation and histopathological damage;downregulated mRNA and protein expressions of ATF3,HNF4ɑ and PEPCK,as well as CYP8B1 mRNA expression(P<0.01);and upregulated mRNA and protein expressions of FXR and CYP7A1,along with SRB1 mRNA expression(P<0.01).CONCLUSION D.eriocarpa petroleum ether fraction ameliorates glucose and lipid metabolism dysregulation in MS mice by modulating the ATF3/HNF4ɑ/CYP7A1 signaling pathway,consequently eliciting hypoglycemic,hypolipidemic,hepatoprotective and nephroprotective effects.
8.Anterior versus posterior selective fusion for Lenke 5C adolescent idiopathic scoliosis: the evolution of coronal imbalance
Yu WANG ; Yinyu FANG ; Jie LI ; Kiram ABDUKAHAR· ; Zongshan HU ; Bin WANG ; Zhen LIU ; Zezhang ZHU ; Yong QIU
Chinese Journal of Orthopaedics 2025;45(9):561-570
Objective:To investigate the effect of anterior and posterior selective fusion strategy on evolution of coronal pattern in patients with Lenke 5C adolescent idiopathic scoliosis (AIS) and whether upper end vertebra (UEV)-1 strategy in anterior surgery would have an effect on postoperative coronal balance.Methods:A total of 108 Lenke 5C AIS patients with at least 2 years follow-up who underwent anterior or posterior selective thoracolumbar fusion surgery from January 2005 to December 2020 were enrolled, with 51 patients in the anterior group and 57 patients in the posterior group. The patients were categorized into three groups (type A, C 7PL-CSVL<20 mm; type B, C 7PL-CSVL ≥20 mm with C 7PL toward the concave side of the main curve; and type C, C 7PL-CSVL≥20 mm with C 7PL toward the convex side of the main curve) to investigate the evolution of coronal balance of each preoperative coronal pattern at the anterior and posterior groups. Parameters such as thoracolumbar Cobb angle, rate of coronal imbalance, and SRS-22 score were recorded at preoperative, 1 week postoperatively, and final follow-up in both groups. Results:The differences of basic date between the two groups were not statistically significant except for the fusion level (5.2±0.7 vs. 5.6±0.9, t=2.497, P=0.014). In the anterior group, a total of 27 patients with preoperative type A, 23 patients with preoperative type A maintained type A at the 1 week postoperatively, and 2 of them were converted to type C at the final follow-up. Four patients with preoperative type A converted to type C at the 1 week postoperatively, and all of them returned to type A at the final follow-up. A total of 23 patients with preoperative type C, four patients with preoperative type C maintained type C at the 1 week postoperatively, and one of them maintained type C at the final follow-up. Nineteen patients with preoperative type C converted to type A at the 1 week postoperatively, and all of them maintained type A at the final follow-up. In the posterior group, a total of 26 patients with preoperative type A, 22 patients with preoperative type A maintained type A at the 1 week postoperatively, and only 2 of these patients converted to type C at the final follow-up. Four of the preoperative type A patients converted to type C at the 1 week postoperatively, and all of them returned to type A at the final follow-up. A total of 29 patients with preoperative type C, thirteen patients with preoperative type C maintained type C at the 1 week postoperatively, and 7 of them maintained type C at the last follow-up. Sixteen patients with preoperative type C converted to type A at the 1 week postoperatively, of whom two converted to type C at the final follow-up. For patients with preoperative type C the rate of coronal imbalance was significantly lower in the anterior group than in the posterior group both in the immediate postoperative period (17% vs. 45%, P<0.05) and at the final follow-up (4% vs. 31%, P=0.038). The rate of coronal imbalance at final follow-up was significantly lower in the UEV-1 group than in the UEV group in the posterior approach (3% vs. 38%, P<0.05), and there was no difference between the two groups in the anterior approach. There were no significant differences in radiographic parameters and SRS-22 scores between the two groups, except for the thoracic Cobb angle at the final follow-up, which was greater in the anterior group than in the posterior group at the final follow-up (19.5±7.3 vs.16.4±5.6, t=2.427, P=0.017). Multivariate logistic regression analysis revealed that anterior surgery and Risser were risk factors for postoperative CIB of preoperative type C ( OR=21.138, P=0.030 and OR=0.406, P=0.048 respectively). Conclusion:For patients with preoperative type A, both anterior and posterior procedures lead to a satisfactory reconstruction of coronal balance. In patients with preoperative type C, anterior surgery acquire a better reconstruction of coronal balance. The strategy of proximal UEV-1 was similar to the strategy of UEV in terms of restoring coronary balance in anterior approach and it was unable to lower the rate of postoperative coronal imbalance. In contrast, UEV-1 strategy in posterior surgery was effective in reducing the rate of postoperative coronal imbalance.
9.Standardization of electronic medical records data in rehabilitation
Yifan TIAN ; Fang XUN ; Haiyan YE ; Ye LIU ; Yingxin ZHANG ; Yaru YANG ; Zhongyan WANG ; Meng ZHANG ; Xiaoxie LIU ; Yanyan YANG ; Bin ZENG ; Mouwang ZHOU ; Yuxiao XIE ; Guangxu XU ; Jiejiao ZHENG ; Mingsheng ZHANG ; Xiangming YE ; Fubiao HUANG ; Qiuchen HUANG ; Yiji WANG ; Di CHEN ; Zhuoying QIU
Chinese Journal of Rehabilitation Theory and Practice 2025;31(1):33-44
ObjectiveTo explore the data standard system of electronic medical records in the field of rehabilitation, focusing on the terminology and coding standards, data structure, and key content categories of rehabilitation electronic medical records. MethodsBased on the Administrative Norms for the Application of Electronic Medical Records issued by the National Health Commission of China, the electronic medical record standard architecture issued by the International Organization for Standardization and Health Level Seven (HL7), the framework of the World Health Organization Family of International Classifications (WHO-FICs), Basic Architecture and Data Standards of Electronic Medical Records, Basic Data Set of Electronic Medical Records, and Specifications for Sharing Documents of Electronic Medical Records, the study constructed and organized the data structure, content, and data standards of rehabilitation electronic medical records. ResultsThe data structure of rehabilitation electronic medical records should strictly follow the structure of electronic medical records, including four levels (clinical document, document section, data set and data element) and four major content areas (basic information, diagnostic information, intervention information and cost information). Rehabilitation electronic medical records further integrated information related to rehabilitation needs and characteristics, emphasizing rehabilitation treatment, into clinical information. By fully applying the WHO-FICs reference classifications, rehabilitation electronic medical records could establish a standardized framework, diagnostic criteria, functional description tools, coding tools and terminology index tools for the coding, indexing, functional description, and analysis and interpretation of diseases and health problems. The study elaborated on the data structure and content categories of rehabilitation electronic medical records in four major categories, refined the granularity of reporting rehabilitation content in electronic medical records, and provided detailed data reporting guidance for rehabilitation electronic medical records. ConclusionThe standardization of rehabilitation electronic medical records is significant for improving the quality of rehabilitation medical services and promoting the rehabilitation process of patients. The development of rehabilitation electronic medical records must be based on the national and international standards. Under the general electronic medical records data structure and standards, a rehabilitation electronic medical records data system should be constructed which incorporates core data such as disease diagnosis, functional description and assessment, and rehabilitation interventions. The standardized rehabilitation electronic medical records scheme constructed in this study can support the improvement of standardization of rehabilitation electronic medical records data information.
10.Systematic review of a body image assessment tool for burn patients
Ning LIU ; Jingling LI ; Shunli ZUO ; Xiuyuan ZHU ; Yiping FANG ; Lihong QIU
Chinese Journal of Nursing 2025;60(4):478-486
Objective The measurement characteristics of body image specificity evaluation tools for burn patients were systematically evaluated,aims to provide reference for selecting appropriate assessment tools.Methods CNKI,Wanfang data knowledge service platform,VIP database,China Biomedical Literature Service system,PubMed,Embase,Web of Science,PsycINFO and CINAHL were searched by computer to collect and evaluate the measurement characteristics of burn patients'body image specificity evaluation tools from the establishment of the database to April 15,2024.There were 2 researchers who independently reviewed the collected literature,looked for the full text and extracted information.At the same time,the methodological quality and measurement performance of such assessment tools were systematically evaluated under the guidance of consensus-based standards for the selection of health measurement instrument(COSMIN)guidelines.Finally,the quality and strength were rated to form a recommendation.Results A total of 6 studies were included,including 3 evaluation tools for body image specificity of burn patients,namely the Body Image Quality of Life Inventory into Brazilian Portuguese(BIQLI-BP),Satisfaction with Appearance Scale(SWAP),and the Derriford Appearance Scale 59(DAS59).In the development of PROMs,the overall quality of BIQLI-BP,SWAP and DAS59 is"doubtful".In terms of content validity,the methodological quality of BIQLI-BP,SWAP and DAS59 was evaluated as"doubtful".In terms of construct validity,the methodological quality of SWAP and DAS59 was evaluated as"good"and"very good"respectively,while the methodological quality of BIQLI-BP was"inadequate".In terms of internal consistency,the methodological quality of BIQLI-BP,SWAP and DAS59 was"very good".In terms of stability,the BIQLI-BP and DAS59 were"unreported",and the methodological quality evaluation of the SWAP was"doubtful".In terms of criterion validity,the BIQLI-BP and DAS59 scales were"unreported",and the methodological quality evaluation of the SWAP scale was"inadequate".In terms of measurement errors,the BIQLI-BP and DAS59 scales were"unreported",and the methodological quality evaluation of the SWAP scale was"doubtful".In the aspect of hypothesis test,except that the DAS59 scale is"unreported",the methodological quality of BIQLI-BP scale is"very good"and the evaluation of SWAP scale is"doubtful".Conclusion Among the existing body image specificity evaluation tools for burn patients,the SWAP has good measurement performance and it can be recommended for the time being.The number of specific evaluation tools for body image of burn patients in China is relatively insufficient,and more localization studies should be carried out in the future.

Result Analysis
Print
Save
E-mail