1.Clinical Study on Acupoint Automatic Positioning Moxibustion Therapy Robot for Treatment of Lumbar Disc Herniation
Shuangyue LI ; Juntao YAN ; Fanfu FANG ; Yuxin ZHENG ; Chengbing CAO ; Yuan YUAN ; Feiran ZHAO ; Qing XU ; Xiaojie SU ; Guohui ZHANG
Chinese Journal of Information on Traditional Chinese Medicine 2025;32(5):154-161
Objective To investigate the clinical advantages and safety of an acupoint auto-positioning moxibustion robot combined with massage techniques in the treatment of lumbar disc herniation.Methods Totally 114 patients with lumbar disc herniation treated between June 2021 and December 2023 at Yueyang Hospital of Integrated Traditional Chinese and Western Medicine,Shanghai University of Traditional Chinese Medicine,the Outpatient Department of Rehabilitation Medicine,Changhai Hospital and Shanghai Third Rehabilitation Hospital were divided into control group and experimental group with random number table method,with 57 cases in each group.The control group received conventional moxibustion combined with massage techniques,while the experimental group was treated using an acupoint auto-positioning moxibustion robot combined with massage techniques.Both groups underwent treatment once every three days,totaling 10 sessions over one month.Clinical efficacy was observed between the two groups by comparing pre-treatment and post-treatment(after 3,6 and 10 sessions)scores on the visual analogue scale(VAS)for pain,the Japanese Orthopaedic Association(JOA)lower back pain score,and lumbar range of motion(LROM).Adverse reactions during the intervention were recorded.Satisfaction with the moxibustion robot in the experimental group was assessed using a Likert scale.Additionally,20 healthy subjects were recruited to evaluate the accuracy of the robot's acupoint auto-positioning function.Results The overall effective rate was 91.23%(52/57)in the experimental group and 94.74%(54/57)in the control group,without statistical significance between the two groups(P>0.05).Compared to pre-treatment,both groups showed significant improvements in VAS scores,JOA scores and LROM across all measured directions after 3,6,and 10 treatment sessions(P<0.001).In the Likert scale assessment,86.96%of subjects agreed that the device was convenient to use,87.72%agreed that the device was safer than conventional moxibustion therapy,and 94.74%were willing to recommend the device to other patients.The accuracy evaluation of the acupoint auto-positioning moxibustion robot demonstrated that the average deviation between robot-positioned acupoints and standard acupoints was(1.68±0.46)mm,achieving a positioning accuracy rate exceeding 95%.No adverse reactions were reported during the intervention.Conclusion The combination of an acupoint auto-positioning moxibustion robot with massage techniques is as effective as conventional moxibustion combined with massage techniques in improving clinical symptoms,alleviating pains,enhancing lumbar function and increasing lumbar mobility in patients with lumbar disc herniation.Participants have exhibited a high willingness to use the device,and the robot achieved a high accuracy rate in acupoint positioning.
2.Ion Unidirectional Ejection Simulation Study of An Extremely Miniature Hyperbolic Linear Ion Trap
Yun-Fan HE ; Zhuo-Qing YANG ; Yan WANG ; Jiu-Wen SUN ; Yun-Na SUN ; Lu-Yue ZHU ; Di ZHANG ; Feng-Dan WANG ; Min LIU ; Gui-Fu DING ; Jin-Yuan YAO
Chinese Journal of Analytical Chemistry 2025;53(6):885-893
With the increasing demand for dynamic,real-time and rapid qualitative analysis of chemical composition in areas such as emergency response and space exploration,chip-scale mass spectrometers have attracted significant attention.These devices are expected to drive the integration of mass spectrometry with micro/nano-fabrication and intelligent sensing technologies,fostering profound innovation and breakthroughs in analytical chemistry.As an excellent mass analyzer,the ion trap exhibits numerous advantages,and its miniaturization creates favorable conditions for the high-density integration of miniature mass spectrometers.However,the reduction in ion storage capacity may compromise its sensitivity and dynamic range,rendering the study of ion unidirectional ejection in highly miniaturized ion traps of significant practical importance.In this work,a research was conducted on achieving efficient ion unidirectional ejection while maintaining high mass resolution in the extremely miniature hyperbolic linear ion trap(M-HLIT)with a field radius of 1 mm,and an electric field compensation method was proposed,which combined asymmetric electrode stretching and unbalanced RF voltage to achieve high-precision optimization of the electric field composition.Simulations showed that in an ideal structure,this method achieved 100%unidirectional ejection efficiency with the mass resolution of 518,significantly outperforming traditional asymmetric structure method(365)and unbalanced voltage method(321).Following the introduction of ion ejection slots,further optimization through bidirectional stretching and electrical parameters improved the resolution to 790 while maintaining a unidirectional ejection efficiency of 93%.This method eliminated the requirement for additional excitation voltage,offering an ideal solution for the miniature mass analyzer with high detection performance of chip-level mass spectrometers.
3.AuNPs-FeCDs Dual Nanozyme Cascade System Integrated with A Smartphone Platform for Sensitive Detection of Glucose
Qing-Jing YE ; Xue-Ying ZHOU ; Yan-Ying ZHENG ; Yun ZHANG ; Wen-Ying JIN ; Ya-Li YUAN
Chinese Journal of Analytical Chemistry 2025;53(9):1457-1466
A centrifugation-free,single-reaction colorimetric method for detection of glucose,utilizing a dual nanozyme cascade system based on gold nanoparticles(AuNPs)and iron-doped carbon dots(FeCDs),was developed in this work.The AuNPs exhibited glucose oxidase-like activity to catalyze glucose oxidation for generation of H2O2,while the FeCDs demonstrated peroxidase-like activity to subsequently catalyze the H2O2-mediated oxidation of 3,3',5,5'-tetramethylbenzidine(TMB).To prevent interference from the blue signal generated by self-aggregation of AuNPs in subsequent quantitative detection,the reaction system was terminated with HCl,converting oxTMB into a stable yellow product.Based on changes in the absorbance at 450 nm of this yellow solution,a quantitative relationship was established between glucose concentration and absorbance at 450 nm(A450).Experimental results demonstrated that this sensor achieved a linear detection range of 44 μmol/L to 11.11 mmol/L(R2=0.993)with a detection limit of 30.68 μmol/L and spiked recoveries of 97.9%-104.7%.By integrating smartphone-based color recognition capabilities,a rapid visual detection platform was established for quantification of glucose through RGB analysis.The validation experimental results using commercial glucose injection samples further confirmed the practical application potential of this methodology.
4.Delayed covering causes the accumulation of motile sperm, leading to overestimation of sperm concentration and motility with a Makler counting chamber.
Lin YU ; Qing-Yuan CHENG ; Ye-Lin JIA ; Yan ZHENG ; Ting-Ting YANG ; Ying-Bi WU ; Fu-Ping LI
Asian Journal of Andrology 2025;27(1):59-64
According to the World Health Organization (WHO) manual, sperm concentration should be measured using an improved Neubauer hemocytometer, while sperm motility should be measured by manual assessment. However, in China, thousands of laboratories do not use the improved Neubauer hemocytometer or method; instead, the Makler counting chamber is one of the most widely used chambers. To study sources of error that could impact the measurement of the apparent concentration and motility of sperm using the Makler counting chamber and to verify its accuracy for clinical application, 67 semen samples from patients attending the Department of Andrology, West China Second University Hospital, Sichuan University (Chengdu, China) between 13 September 2023 and 27 September 2023, were included. Compared with applying the cover glass immediately, delaying the application of the cover glass for 5 s, 10 s, and 30 s resulted in average increases in the sperm concentration of 30.3%, 74.1%, and 107.5%, respectively (all P < 0.0001) and in the progressive motility (PR) of 17.7%, 30.8%, and 39.6%, respectively (all P < 0.0001). However, when the semen specimens were fixed with formaldehyde, a delay in the application of the cover glass for 5 s, 10 s, and 30 s resulted in an average increase in the sperm concentration of 6.7%, 10.8%, and 14.6%, respectively, compared with immediate application of the cover glass. The accumulation of motile sperm due to delays in the application of the cover glass is a significant source of error with the Makler counting chamber and should be avoided.
Humans
;
Male
;
Sperm Motility/physiology*
;
Sperm Count
;
Semen Analysis/methods*
;
Spermatozoa/physiology*
;
Time Factors
5.Explanation and interpretation of blood transfusion provisions for children with hematological diseases in the national health standard "Guideline for pediatric transfusion".
Ming-Yi ZHAO ; Rong HUANG ; Rong GUI ; Qing-Nan HE ; Ming-Yan HEI ; Xiao-Fan ZHU ; Jun LU ; Xiao-Jun XU ; Tian-Ming YUAN ; Rong ZHANG ; Xu WANG ; Jin-Ping LIU ; Jing WANG ; Zhi-Li SHAO ; Yong-Jian GUO ; Xin-Yin WU ; Jia-Rui CHEN ; Qi-Rong CHEN ; Jia GUO ; Ming-Hua YANG
Chinese Journal of Contemporary Pediatrics 2025;27(1):18-25
To guide clinical blood transfusion practices for pediatric patients, the National Health Commission has issued the health standard "Guideline for pediatric transfusion" (WS/T 795-2022). Blood transfusion is one of the most commonly used supportive treatments for children with hematological diseases. This guideline provides guidance and recommendations for blood transfusions in children with aplastic anemia, thalassemia, autoimmune hemolytic anemia, glucose-6-phosphate dehydrogenase deficiency, acute leukemia, myelodysplastic syndromes, immune thrombocytopenic purpura, and thrombotic thrombocytopenic purpura. This article presents the evidence and interpretation of the blood transfusion provisions for children with hematological diseases in the "Guideline for pediatric transfusion", aiming to assist in the understanding and implementing the blood transfusion section of this guideline.
Humans
;
Child
;
Hematologic Diseases/therapy*
;
Blood Transfusion/standards*
;
Practice Guidelines as Topic
6.Explanation and interpretation of the compilation of blood transfusion provisions for children undergoing hematopoietic stem cell transplantation in the national health standard "Guideline for pediatric transfusion".
Rong HUANG ; Qing-Nan HE ; Ming-Yan HEI ; Xiao-Fan ZHU ; Jun LU ; Xiao-Jun XU ; Tian-Ming YUAN ; Rong ZHANG ; Xu WANG ; Jin-Ping LIU ; Jing WANG ; Zhi-Li SHAO ; Ming-Yi ZHAO ; Yong-Jian GUO ; Xin-Yin WU ; Jia-Rui CHEN ; Qi-Rong CHEN ; Jia GUO ; Rong GUI ; Ming-Hua YANG
Chinese Journal of Contemporary Pediatrics 2025;27(2):139-143
To guide clinical blood transfusion practices for pediatric patients, the National Health Commission has issued the health standard "Guideline for pediatric transfusion" (WS/T 795-2022). Blood transfusion for children undergoing hematopoietic stem cell transplantation is highly complex and challenging. This guideline provides recommendations on transfusion thresholds and the selection of blood components for these children. This article presents the evidence and interpretation of the transfusion provisions for children undergoing hematopoietic stem cell transplantation, with the aim of enhancing the understanding and implementation of the "Guideline for pediatric transfusion".
Humans
;
Hematopoietic Stem Cell Transplantation
;
Child
;
Blood Transfusion/standards*
;
Practice Guidelines as Topic
7.Explanation and interpretation of blood transfusion provisions for critically ill and severely bleeding pediatric patients in the national health standard "Guideline for pediatric transfusion".
Rong HUANG ; Qing-Nan HE ; Ming-Yan HEI ; Ming-Hua YANG ; Xiao-Fan ZHU ; Jun LU ; Xiao-Jun XU ; Tian-Ming YUAN ; Rong ZHANG ; Xu WANG ; Jin-Ping LIU ; Jing WANG ; Zhi-Li SHAO ; Ming-Yi ZHAO ; Yong-Jian GUO ; Xin-Yin WU ; Jia-Rui CHEN ; Qi-Rong CHEN ; Jia GUO ; Rong GUI
Chinese Journal of Contemporary Pediatrics 2025;27(4):395-403
To guide clinical blood transfusion practices for pediatric patients, the National Health Commission has issued the health standard "Guideline for pediatric transfusion" (WS/T 795-2022). Critically ill children often present with anemia and have a higher demand for transfusions compared to other pediatric patients. This guideline provides guidance and recommendations for blood transfusions in cases of general critical illness, septic shock, acute brain injury, extracorporeal membrane oxygenation, non-life-threatening bleeding, and hemorrhagic shock. This article interprets the background and evidence of the blood transfusion provisions for critically ill and severely bleeding children in the "Guideline for pediatric transfusion", aiming to enhance understanding and implementation of this aspect of the guidelines. Citation:Chinese Journal of Contemporary Pediatrics, 2025, 27(4): 395-403.
Humans
;
Critical Illness
;
Blood Transfusion/standards*
;
Child
;
Hemorrhage/therapy*
;
Practice Guidelines as Topic
8.Explanation and interpretation of blood transfusion provisions for children undergoing cardiac surgery in the national health standard "Guideline for pediatric transfusion".
Rong HUANG ; Qing-Nan HE ; Ming-Yan HEI ; Ming-Hua YANG ; Xiao-Fan ZHU ; Jun LU ; Xiao-Jun XU ; Tian-Ming YUAN ; Rong ZHANG ; Xu WANG ; Jing WANG ; Zhi-Li SHAO ; Ming-Yi ZHAO ; Yong-Jian GUO ; Xin-Yin WU ; Jia-Rui CHEN ; Qi-Rong CHEN ; Jia GUO ; Rong GUI ; Jin-Ping LIU
Chinese Journal of Contemporary Pediatrics 2025;27(7):778-785
To guide clinical blood transfusion practices in pediatric patients, the National Health Commission has issued the health standard "Guideline for pediatric transfusion" (WS/T 795-2022). Children undergoing cardiac surgery are at high risk of bleeding, and the causes of perioperative anemia and coagulation disorders in neonates and children are complex and varied, often necessitating the transfusion of allogeneic blood components. This guideline provides direction and recommendations for specific measures in blood management for children undergoing cardiac surgery before, during, and after surgery. This article interprets the background and evidence for the formulation of the blood transfusion provisions for children undergoing cardiac surgery, hoping to facilitate the understanding and implementation of this guideline.
Humans
;
Cardiac Surgical Procedures
;
Blood Transfusion/standards*
;
Child
;
Practice Guidelines as Topic
9.Effects of MTHFR and GGH gene polymorphisms on plasma concentrations and toxicity following high-dose methotrexate therapy in children with acute lymphoblastic leukemia.
Lin-Xiao TENG ; Qi AN ; Lei WANG ; Nan WANG ; Qing-Ling KONG ; Rui HAN ; Yuan WANG ; Lu LIU ; Yan WANG ; Shu-Mei XU ; Kun-Peng SHI ; Fang-Shan QIU ; Xi-Xi DU ; Jin-Rui SHI
Chinese Journal of Contemporary Pediatrics 2025;27(7):802-807
OBJECTIVES:
To investigate the effects of methylenetetrahydrofolate reductase (MTHFR) rs1801133 and γ-glutamyl hydrolase (GGH) rs11545078 gene polymorphisms on plasma concentrations and toxicity following high-dose methotrexate (MTX) therapy in children with acute lymphoblastic leukemia (ALL).
METHODS:
Children with ALL treated at the Xuzhou Children's Hospital of Xuzhou Medical University from January 2021 to April 2024 were selected for this study. Genotypes of MTHFR rs1801133 and GGH rs11545078 were determined using multiplex polymerase chain reaction. MTX plasma concentrations were measured by enzyme-multiplied immunoassay technique, and toxicity was graded according to the Common Terminology Criteria for Adverse Events version 5.0. The relationships between MTHFR rs1801133 and GGH rs11545078 genotypes and both MTX plasma concentrations and associated toxicities were analyzed.
RESULTS:
In the low-risk ALL group, the MTHFR rs1801133 genotype was associated with increased MTX plasma concentrations at 72 hours (P<0.05). In the intermediate- to high-risk group, the MTHFR rs1801133 genotype was associated with increased MTX plasma concentrations at 48 hours (P<0.05), and the GGH rs11545078 genotype was associated with increased MTX plasma concentrations at 48 hours (P<0.05). In the intermediate- to high-risk group, the MTHFR rs1801133 genotype was associated with the occurrence of reduced hemoglobin (P<0.05), and the GGH rs11545078 genotype was associated with the occurrence of thrombocytopenia (P<0.05).
CONCLUSIONS
Detection of MTHFR rs1801133 and GGH rs11545078 genotypes can be used to predict increased MTX plasma concentrations and the occurrence of toxic reactions in high-dose MTX treatment of ALL, enabling timely interventions to enhance safety.
Humans
;
Methotrexate/toxicity*
;
Methylenetetrahydrofolate Reductase (NADPH2)/genetics*
;
Precursor Cell Lymphoblastic Leukemia-Lymphoma/blood*
;
Male
;
Female
;
Child
;
Child, Preschool
;
gamma-Glutamyl Hydrolase/genetics*
;
Antimetabolites, Antineoplastic/adverse effects*
;
Infant
;
Polymorphism, Genetic
;
Adolescent
;
Genotype
;
Polymorphism, Single Nucleotide
10.Characteristics and Risk Analysis of COVID-19 Infection in Patients with Multiple Myeloma after Autologous Hematopoietic Stem Cell Transplantation.
Meng-Meng PAN ; Shi-Wei JIN ; Wan-Yan OUYANG ; Yan WAN ; Yi TAO ; Yuan-Fang LIU ; Wei-Ping ZHANG ; Jian-Qing MI
Journal of Experimental Hematology 2025;33(5):1358-1365
OBJECTIVE:
To retrospectively analyze the characteristics and influencing factors of COVID-19 infection in patients with multiple myeloma (MM) who underwent autologous hematopoietic stem cell transplantation (AHSCT).
METHODS:
The clinical data of MM patients who underwent AHSCT in Ruijin Hospital Affiliated to Shanghai Jiao Tong University School of Medicine from May 26, 2021 to December 26, 2022 were collected. The onset of COVID-19 infection, corresponding symptoms and laboratory tests were followed up in outpatient or by the means of telephone contact and online questionnaires. Related analysis was then performed.
RESULTS:
This study included 96 patients, and 72 cases among them were infected with COVID-19 while 24 cases were uninfected. Logistic regression analysis showed that vaccination did not significantly reduce the risk of COVID-19 infection, but patients who received two doses of the vaccine had a lower risk of developing moderate and severe disease than those who did not receive or received one dose (OR =0.06, P =0.029). Patients who received daratumumab before had a higher risk of COVID-19 infection (OR =5.78, P =0.039), while those with a history of immunomodulatory drugs (IMiDs) had the opposite effect (OR =0.31, P =0.028). The use of both drugs did not affect the severity of COVID-19 infection.
CONCLUSION
For MM patients undergoing AHSCT as first-line chemotherapy, COVID-19 vaccination does not significantly reduce the infection rate, but it plays a role in preventing moderate and severe cases. The application of antineoplastic drugs with different mechanisms has a certain impact on the susceptibility to the COVID-19, which should be considered comprehensively when creating treatment plans.
Humans
;
Multiple Myeloma/complications*
;
COVID-19/epidemiology*
;
Hematopoietic Stem Cell Transplantation
;
Transplantation, Autologous
;
Retrospective Studies
;
Risk Assessment
;
Risk Factors
;
Male
;
Female
;
Middle Aged
;
SARS-CoV-2
;
Adult
;
Antibodies, Monoclonal

Result Analysis
Print
Save
E-mail