1.Research Progress of Chinese Medicine Monomers in Treatment of Cholangiocarcinoma.
Xiang WANG ; Xiao-Qing WANG ; Kai LUO ; He BAI ; Jia-Lin QI ; Gui-Xin ZHANG
Chinese journal of integrative medicine 2025;31(2):170-182
Cholangiocarcinoma (CCA) is a malignant tumor originating from cholangiocytes. However, it remains unclear about the pathogenesis of this carcinoma, which may be related to multiple factors. Currently, CCA is mainly treated by surgery, chemotherapy, and radiotherapy. Among them, surgery is the only potentially curative option for CCA. Nevertheless, the high malignancy and asymptomatic nature of CCA may lead to poor treatment outcomes. It has been demonstrated that Chinese medicine (CM) plays a significant role in various antitumor applications. Meanwhile, CM exhibits fewer side effects and high availability. Moreover, the in vitro application of CM monomers has been explored in many domestic and foreign studies. This article mainly reviews the signaling pathways and molecular mechanisms of CM monomers in the treatment of CCA in recent years. These findings are expected to provide new insights into the treatment of CCA.
Cholangiocarcinoma/drug therapy*
;
Humans
;
Drugs, Chinese Herbal/pharmacology*
;
Bile Duct Neoplasms/drug therapy*
;
Medicine, Chinese Traditional
;
Animals
;
Signal Transduction/drug effects*
2.Quality evaluation of Gegen Formula Granules
Dai-liang ZHANG ; Chun-xia WANG ; Lei SHI ; Yu-kang LIU ; Yong-qiang LIN ; Yu-zhuo WANG ; Jing-hua ZHANG ; Jin-xin LI ; Gui-yun CAO ; Zhao-qing MENG
Chinese Traditional Patent Medicine 2025;47(5):1421-1431
AIM To evaluate the quality of Gegen Formula Granules.METHODS Linear calibration with two reference substances(LCTRS)was adopted in the predicting of retention time with puerarin and daidzein as internal standards.UPLC characteristic chromatograms were established.The contents of 3'-hydroxy puerarin,puerarin(internal standard),3'-methoxy puerarin,puerarin 6"-O-xyloside,puerarin apioside and daidzin were determined by quantitative determination analysis multi-components by a single marker(QAMS),after which their transfer rates were calculated.RESULTS Compared with relative retention time method,LCTRS demonstrated higher positional accuracy for characteristic peaks and wider application range for columns.There were 9 characteristic peaks in the characteristic chromatograms for 14 batches of formula granules and 15 batches of standard decoctions with the similarities of more than 0.95.The contents and transfer rates of various constituents in formula granules and standard decoctions were basically consistent.CONCLUSION The chemical constituents in formula granules and their standard decoctions of Puerariae lobatae Radix display good consistency,reliable preparation process is observable in the former.
3.Evaluation of chemical constituent consistency in formula granules and traditional decoctions of Gouteng Jiangya Formula
Qing-gang ZHANG ; Dai-liang ZHANG ; Hong QI ; Shu-wen DING ; Yu-zhuo WANG ; Yun-lun LI ; Ji-fu HE ; Huan-ying GUO ; Gui-yun CAO ; Zhao-qing MENG
Chinese Traditional Patent Medicine 2025;47(11):3555-3565
AIM To evaluate the chemical constituent consistency in formula granules and traditional decoctions of Gouteng Jiangya Formula.METHODS HPLC characteristic chromatograms were established,the analysis was performed on a 30 ℃ thermostatic YMC-Triart C18 column(4.6 mm× 250 mm,5 μm),with the mobile phase comprising of acetonitrile-0.2%phosphoric acid flowing at 1.0 mL/min in a gradient elution manner,and the detection wavelength was set at 240 nm.Puerarin was used as an internal standard to calculate the relative correction factors of 3'-methoxy puerarin,puerarin apioside,magnolflorine,paeoniflora,daidzin,baicalin,palmatine,berberine,wogonoside and benzoylpaeoniflorin,after which the content detemination was made by quantitative analysis of multi-components by single-marker(QAMS).RESULTS The characteristic chromatograms of 9 batches of formula granules and 15 bacthes of traditional decoctions demonstrated the similarities of more than 0.90 at the detection wavelengths of 192,210,240,260,280,300,320,360 nm,along with similar total peak areas.Eleven constituents showed good linear relationships within their own ranges(r>0.999 0),whose average recoveries were 97.27%-101.64%with the RSDs of 0.36%-1.11%,the result obtained by QAMS and external standard method demonstrated no significant differences(P>0.05).The contents of various constituents in the formula granules approximated those in the traditional decoctions.CONCLUSION The consistent kinds and contents of various constituents are obversable in formula granules and traditional decoctions of Gouteng Jiangya Formula,which can provide a reference for the reasonable clinical application of this formula.
4.Comparative experimental study on the biomechanical properties of retrograde tibial nailing and distal tibia L-shaped plate in distal tibia fracture.
Xu-Ping LIN ; Qing-Jun LIU ; Sheng-Gui XU ; Cong ZHANG ; Ming-Ming GAO ; Zhen-Qi DING ; Bin LIN
China Journal of Orthopaedics and Traumatology 2025;38(7):737-742
OBJECTIVE:
To investigate the biomechanical characteristics of retrograde tibial nailing (RTN) and distal tibial L-shaped plating in the internal fixation of distal tibial fractures.
METHODS:
Fourteen fresh adult tibia specimens were selected, comprising 7 males and 7 females aged from 34 to 55 years old. The specimens were randomly divided into experimental group and control group by numerical table method with 7 specimens in each group. RTN was used for internal fixation of distal tibial fractures in the experimental group, and L-shaped plate was used for internal fixation of distal tibial fractures in the control group. The axial compression properties of the two groups of specimens were tested under the pressure of 100, 200, 300, 400, and 500 N after operation, and torsional resistance at torque levels of 1.0, 2.0, 3.0, 4.0, 5.0 N·m. The anti-fatigue performance of the specimens was tested at 500 N pressure for 3 000 and 10 000 cycles. X-ray fluoroscopy was performed to observe whether the the internal fixator was deformed and whether the screw was loosened or broken.
RESULTS:
When the pressure was 400 N and 500 N, the axial compression displacement of the experimental group was (1.11±0.06) mm and (1.24±0.05) mm, which were smaller than those of the control group (1.21±0.08) mm and (1.37±0.11) mm, and the differences were statistically signific (P<0.05). Under the pressure of 500 N, the axial compression stiffness of the experimental group was (389.24±17.79) N·mm-1, which was significantly higher than that of the control group (362.37±14.44) N·mm-1(P<0.05). When the torque was 4 and 5 N·m, the torsion angles of the experimental group were (2.97±0.23) ° and (3.41±0.17) °, which were smaller than those of the control group (3.31±0.28) ° and (3.76±0.20) °, and the differences were statistically significant (P<0.05). When the torque was 5 N·m, the torsional stiffness of the experimental group was (1.48±0.07) N·m per degree, which was higher than that of the control group (1.36±0.06) N·m per degree, and the difference was statistically significant (P<0.05). For the intragroup comparison of fatigue resistance, the differences in axial compression displacement between the two groups were not statistically significant at 3 000 and 10 000 cycles (all P>0.05). When 3 000 times and 10 000 times of compression, the axial compression displacement of the experimental group was (1.38±0.08), (1.43±0.07) mm, which was smaller than that of the control group (1.51±0.10), (1.54±0.08) mm, the differences were statistically significant (P<0.05). In the experimental group, no screw loosening, fracture or internal fixation deformation was found, while in the control group, locking screw loosening occurred in 2 models after 10 000 pressures.
CONCLUSION
The biomechanical performance of RTN is obviously better than that of the distal tibial L-shaped plate, which provides biomechanical data support for the clinical application of RTN.
Humans
;
Female
;
Male
;
Adult
;
Tibial Fractures/physiopathology*
;
Middle Aged
;
Biomechanical Phenomena
;
Bone Plates
;
Fracture Fixation, Internal/instrumentation*
;
Bone Nails
;
Tibia/surgery*
5.Explanation and interpretation of blood transfusion provisions for children with hematological diseases in the national health standard "Guideline for pediatric transfusion".
Ming-Yi ZHAO ; Rong HUANG ; Rong GUI ; Qing-Nan HE ; Ming-Yan HEI ; Xiao-Fan ZHU ; Jun LU ; Xiao-Jun XU ; Tian-Ming YUAN ; Rong ZHANG ; Xu WANG ; Jin-Ping LIU ; Jing WANG ; Zhi-Li SHAO ; Yong-Jian GUO ; Xin-Yin WU ; Jia-Rui CHEN ; Qi-Rong CHEN ; Jia GUO ; Ming-Hua YANG
Chinese Journal of Contemporary Pediatrics 2025;27(1):18-25
To guide clinical blood transfusion practices for pediatric patients, the National Health Commission has issued the health standard "Guideline for pediatric transfusion" (WS/T 795-2022). Blood transfusion is one of the most commonly used supportive treatments for children with hematological diseases. This guideline provides guidance and recommendations for blood transfusions in children with aplastic anemia, thalassemia, autoimmune hemolytic anemia, glucose-6-phosphate dehydrogenase deficiency, acute leukemia, myelodysplastic syndromes, immune thrombocytopenic purpura, and thrombotic thrombocytopenic purpura. This article presents the evidence and interpretation of the blood transfusion provisions for children with hematological diseases in the "Guideline for pediatric transfusion", aiming to assist in the understanding and implementing the blood transfusion section of this guideline.
Humans
;
Child
;
Hematologic Diseases/therapy*
;
Blood Transfusion/standards*
;
Practice Guidelines as Topic
6.Explanation and interpretation of the compilation of blood transfusion provisions for children undergoing hematopoietic stem cell transplantation in the national health standard "Guideline for pediatric transfusion".
Rong HUANG ; Qing-Nan HE ; Ming-Yan HEI ; Xiao-Fan ZHU ; Jun LU ; Xiao-Jun XU ; Tian-Ming YUAN ; Rong ZHANG ; Xu WANG ; Jin-Ping LIU ; Jing WANG ; Zhi-Li SHAO ; Ming-Yi ZHAO ; Yong-Jian GUO ; Xin-Yin WU ; Jia-Rui CHEN ; Qi-Rong CHEN ; Jia GUO ; Rong GUI ; Ming-Hua YANG
Chinese Journal of Contemporary Pediatrics 2025;27(2):139-143
To guide clinical blood transfusion practices for pediatric patients, the National Health Commission has issued the health standard "Guideline for pediatric transfusion" (WS/T 795-2022). Blood transfusion for children undergoing hematopoietic stem cell transplantation is highly complex and challenging. This guideline provides recommendations on transfusion thresholds and the selection of blood components for these children. This article presents the evidence and interpretation of the transfusion provisions for children undergoing hematopoietic stem cell transplantation, with the aim of enhancing the understanding and implementation of the "Guideline for pediatric transfusion".
Humans
;
Hematopoietic Stem Cell Transplantation
;
Child
;
Blood Transfusion/standards*
;
Practice Guidelines as Topic
7.Explanation and interpretation of blood transfusion provisions for critically ill and severely bleeding pediatric patients in the national health standard "Guideline for pediatric transfusion".
Rong HUANG ; Qing-Nan HE ; Ming-Yan HEI ; Ming-Hua YANG ; Xiao-Fan ZHU ; Jun LU ; Xiao-Jun XU ; Tian-Ming YUAN ; Rong ZHANG ; Xu WANG ; Jin-Ping LIU ; Jing WANG ; Zhi-Li SHAO ; Ming-Yi ZHAO ; Yong-Jian GUO ; Xin-Yin WU ; Jia-Rui CHEN ; Qi-Rong CHEN ; Jia GUO ; Rong GUI
Chinese Journal of Contemporary Pediatrics 2025;27(4):395-403
To guide clinical blood transfusion practices for pediatric patients, the National Health Commission has issued the health standard "Guideline for pediatric transfusion" (WS/T 795-2022). Critically ill children often present with anemia and have a higher demand for transfusions compared to other pediatric patients. This guideline provides guidance and recommendations for blood transfusions in cases of general critical illness, septic shock, acute brain injury, extracorporeal membrane oxygenation, non-life-threatening bleeding, and hemorrhagic shock. This article interprets the background and evidence of the blood transfusion provisions for critically ill and severely bleeding children in the "Guideline for pediatric transfusion", aiming to enhance understanding and implementation of this aspect of the guidelines. Citation:Chinese Journal of Contemporary Pediatrics, 2025, 27(4): 395-403.
Humans
;
Critical Illness
;
Blood Transfusion/standards*
;
Child
;
Hemorrhage/therapy*
;
Practice Guidelines as Topic
8.Explanation and interpretation of blood transfusion provisions for children undergoing cardiac surgery in the national health standard "Guideline for pediatric transfusion".
Rong HUANG ; Qing-Nan HE ; Ming-Yan HEI ; Ming-Hua YANG ; Xiao-Fan ZHU ; Jun LU ; Xiao-Jun XU ; Tian-Ming YUAN ; Rong ZHANG ; Xu WANG ; Jing WANG ; Zhi-Li SHAO ; Ming-Yi ZHAO ; Yong-Jian GUO ; Xin-Yin WU ; Jia-Rui CHEN ; Qi-Rong CHEN ; Jia GUO ; Rong GUI ; Jin-Ping LIU
Chinese Journal of Contemporary Pediatrics 2025;27(7):778-785
To guide clinical blood transfusion practices in pediatric patients, the National Health Commission has issued the health standard "Guideline for pediatric transfusion" (WS/T 795-2022). Children undergoing cardiac surgery are at high risk of bleeding, and the causes of perioperative anemia and coagulation disorders in neonates and children are complex and varied, often necessitating the transfusion of allogeneic blood components. This guideline provides direction and recommendations for specific measures in blood management for children undergoing cardiac surgery before, during, and after surgery. This article interprets the background and evidence for the formulation of the blood transfusion provisions for children undergoing cardiac surgery, hoping to facilitate the understanding and implementation of this guideline.
Humans
;
Cardiac Surgical Procedures
;
Blood Transfusion/standards*
;
Child
;
Practice Guidelines as Topic
9.Dual-modal Magnetic Resonance Imaging Contrast Agents Based on Polymetallic Nanoclusters for Targeted Diagnosis of Prostate Cancer
Qing-Dong LI ; Peng WANG ; Jian-Min XIAO ; Wen-Juan GAO ; Zhen-Hong XIA ; Gui-Long ZHANG ; Zheng-Yan WU
Chinese Journal of Analytical Chemistry 2025;53(4):602-611
Fe/Mn/Gd polymetallic nanooxide(FMGN)were prepared by one-step solvent thermal reaction by using Fe(acac)3,Mn(acac)2 and Gd(acac)3 as reaction precursors.Next,hyaluronic acid(HA)was used to modify FMGN to fabricate tumor-targeting T 1-T 2 dual-mode magnetic resonance imaging(MRI)contrast agent(HA-FMGN)for accurate diagnosis of prostate cancer.The structure and morphology of FMGN were observed by transmission electron microscope(TEM).It was found that FMGN exhibited a uniform nanocluster spherical structure when the feeding ratio of iron acetylacetonate,manganese acetylacetonate,and gadolinium acetylacetonate was 3:2:1.X-ray diffraction(XRD)analysis showed that FMGN had a typical inverse spinel structure of Mn doped Fe 3O 4,with Gd existing in the form of amorphous gadolinium oxide.The longitudinal relaxivity(r 1)and transverse relaxivity(r 2)of FMGN were 13.395 and 428.535 L/(mmol·s),respectively,measured by 0.5 T MRI analyzer,which proved that FMGN had excellent T 1-T 2 dual-mode MRI contrast capability.The cytotoxicity and hemolysis test found that HA-FMGN didn't damage red cells and induce toxicity for normal cells,indicating that HA-FMGN had excellent cell biocompatibility.The internalization efficacy of HA-FMGN was observed by CLSM,and the results showed that HA-FMGN possessed excellent prostate tumor-targeting ability.In vivo MRI experiment showed that HA-FMGN significantly enhanced T 1 and T 2 weighted MRI signal to noise ratio(SNR)of prostate tumor,which promoted the accurate diagnosis of orthotopic prostate cancer.
10.Ion Unidirectional Ejection Simulation Study of An Extremely Miniature Hyperbolic Linear Ion Trap
Yun-Fan HE ; Zhuo-Qing YANG ; Yan WANG ; Jiu-Wen SUN ; Yun-Na SUN ; Lu-Yue ZHU ; Di ZHANG ; Feng-Dan WANG ; Min LIU ; Gui-Fu DING ; Jin-Yuan YAO
Chinese Journal of Analytical Chemistry 2025;53(6):885-893
With the increasing demand for dynamic,real-time and rapid qualitative analysis of chemical composition in areas such as emergency response and space exploration,chip-scale mass spectrometers have attracted significant attention.These devices are expected to drive the integration of mass spectrometry with micro/nano-fabrication and intelligent sensing technologies,fostering profound innovation and breakthroughs in analytical chemistry.As an excellent mass analyzer,the ion trap exhibits numerous advantages,and its miniaturization creates favorable conditions for the high-density integration of miniature mass spectrometers.However,the reduction in ion storage capacity may compromise its sensitivity and dynamic range,rendering the study of ion unidirectional ejection in highly miniaturized ion traps of significant practical importance.In this work,a research was conducted on achieving efficient ion unidirectional ejection while maintaining high mass resolution in the extremely miniature hyperbolic linear ion trap(M-HLIT)with a field radius of 1 mm,and an electric field compensation method was proposed,which combined asymmetric electrode stretching and unbalanced RF voltage to achieve high-precision optimization of the electric field composition.Simulations showed that in an ideal structure,this method achieved 100%unidirectional ejection efficiency with the mass resolution of 518,significantly outperforming traditional asymmetric structure method(365)and unbalanced voltage method(321).Following the introduction of ion ejection slots,further optimization through bidirectional stretching and electrical parameters improved the resolution to 790 while maintaining a unidirectional ejection efficiency of 93%.This method eliminated the requirement for additional excitation voltage,offering an ideal solution for the miniature mass analyzer with high detection performance of chip-level mass spectrometers.

Result Analysis
Print
Save
E-mail