1.RODENT DENSITY IN THE GARRISONS OF LANZHOU CITY DURING 2014-2022
Jun GAN ; Jing ZUO ; Lin WANG ; Wei WANG ; Xing MENG ; Yong-Long ZHANG ; Qing-Ming SHI ; Xiao-Lei YE
Acta Parasitologica et Medica Entomologica Sinica 2025;32(1):34-38
Objective To investigate the density,species composition,and seasonal prevalence of domestic rodents in different habitats within Lanzhou garrisons,providing basic information for rodent prevention and control.Methods A total of 12 monitoring sites were sampled across urban,suburban,and rural residential areas from 2014 to 2022.Rodent density was monitored using the night-trapping method in the middle of odd-numbered months.Results From 2014 to 2022,346 domestic rodents were captured using 122 035 effective traps,with an average domestic rodent density of 0.28%.The highest domestic rodent density was 0.63%in 2016,and the lowest was 0.07%in 2020,showing significant differences across years,with an overall trend of initially decreasing and then increasing(χ2=136.555,P<0.001).The dominant species was Rattus norvegicus,accounting for 83.24%of the total rodents captured.Rattus norvegicus accounted for a relatively high proportion across different years,with a statistically significant difference in species composition(χ2=20.931,P<0.05).Rodent densities and species composition also varied significantly among the monitored habitats(P<0.001),with the highest densities observed in rural residential areas and the lowest in urban areas.Seasonal variation in rodent densities showed a bimodal pattern,with smaller peaks in January or March and a larger peak in July.Conclusions Domestic rodent density in Lanzhou garrisons has shown an upward trend in the past few years.Rodent control measures should focus on barracks in rural residential areas,with targeted interventions to reduce the risk of rodent-borne diseases.
2.COCKROACH SURVEILLANCE IN LANZHOU FROM 2016 TO 2023
Ying ZHANG ; Jing ZUO ; Qing-Ming SHI ; Zi-Peng LI ; Wen-Juan BA ; Zhi-Qing LI ; Ai-Miao LIAO ; Jing-Jing YU ; Guo-Jing BAO ; Xing LI ; Jun GAN ; Xiao-Lei YE
Acta Parasitologica et Medica Entomologica Sinica 2025;32(2):119-122
Objective To investigate the population composition,seasonal dynamics,and infestation levels of cockroaches in Lanzhou,China,and to provide information for the scientific development of cockroach control strategies.Methods Monitoring was conducted at three locations using the sticky trap method.Habitats included farm product markets,catering establishments,hotels,hospitals,and residential areas.Results From 2016 to 2023,the average cockroach density was 0.77 insects per board,with an average infestation rate of 10.84%.Blattella germanica was the dominant species.Seasonal density of cockroaches showed an approximately unimodal distribution,peaking in September.The highest average density and infestation rates were observed in farm product markets.Conclusions Cockroach density and infestation levels in Lanzhou remained relatively low.A comprehensive prevention and control strategy focusing on environmental management in key areas should be implemented according to the seasonal fluctuations.
3.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
4.Study of Reference Materials for Quantitative Analysis of Gene Copy Numbers of Lentiviral Vectors
Yin-Bo HUO ; Jia-Qi YANG ; Qing TAO ; Wen LIANG ; Li XU ; Lan-Ying LI ; Xiao-Lei ZUO ; Juan YAN ; Min DING ; Ai-Wen MA ; Gang LIU
Chinese Journal of Analytical Chemistry 2025;53(9):1555-1565
Lentiviral vectors(LVs)are key gene delivery tools for integrating target genes into the host genome,but they may also pose risks of insertional mutagenesis.The vector copy number(VCN)in cells is critical for determining the safety of gene modification.However,the reliability and accuracy of its quantification process are influenced by multiple factors.Developing cell reference materials with specific vector copy numbers represents a viable approach to enhance the reliability and consistency of measurement results,enabling quality control of the quantification process and traceability of outcomes.However,the preparation of such reference materials faces challenges in cell sample design,preparation protocols,and advanced quantification techniques.In this study,T lymphocyte cell line Jurkat-based reference materials with LV gene copy numbers of 1 and 2 copy/cell were developed.A high-precision duplex digital polymerase chain reaction(dPCR)method was established to quantify the LV gene and endogenous genes simultaneously.Additionally,the results of dPCR were cross-validated through next-generation sequencing and flow cytometric analysis.Ultimately,confocal microscopy characterization results showed that the developed cell reference materials had intact morphology.The quantification result of VCN-1 was(1.07±0.11)copy/cell,and that of VCN-2 was(2.09±0.21)copy/cell.These cell reference materials demonstrated compliance with stability and homogeneity requirements,and could be applied for quality control throughout the VCN measurement workflow and metrological traceability,improving the accuracy,comparability,and validity of copy number measurements.
5.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
6.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
7.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
8.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
9.Identification of Jr(a-) rare blood type antibodies against anti-Jra: serological and molecular biology analysis and transfusion strategy.
Yunxiang WU ; Hua WANG ; Ruiqing GUO ; Zhicheng LI ; Qing LI ; Dong XIANG ; Yanli JI ; Aijing LI ; Fengyong ZHAO ; Fei WANG ; Jiangtao ZUO ; Yi XU ; Yajun LIANG ; Demei ZHANG
Chinese Journal of Medical Genetics 2025;42(2):145-150
OBJECTIVE:
To report the blood group antigen and antibody specificity identification methods for a patient with high-frequency antibodies, and the process of finding and providing compatible blood for the patient.
METHODS:
A patient sent from the Blood Transfusion Department of Shanxi Provincial People's Hospital to Blood Transfusion Technology Research Laboratory of Taiyuan Blood Center in November 2022 was selected for the study. Classical serological methods were used to determine the patient's blood type, screen for unexpected antibodies, identify antibodies, and perform crossmatching. High-frequency antibody identification was carried out using red blood cells treated with various enzymes. Blood group genotyping was conducted using Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF) and Sanger sequencing. Multiple strategies were employed to address the patient's blood source problem. The study was approved by the Medical Ethics Committee of Taiyuan Blood Center [Ethics No. 2024 Ethics Review No.(2)].
RESULTS:
The patient's blood type was B, RhD positive. Initial screening of the patient's serum with multiple screening cells and antibody identification cells in saline medium was negative, but positive in antiglobulin medium. The patient's serum showed varying reaction intensities with red blood cells treated with different enzymes. MALDI-TOF mass spectrometry and Sanger sequencing revealed a homozygous nonsense variant c.376C>T (p.Gln126Ter) in the ABCG2 gene, resulting in the Jr(a-) phenotype. During family donor selection, the patient's son was found to have a heterozygous variant c.376C>T (p.Gln126Ter), and another heterozygous variant c.421C>A (p.Gln141Lys), which predicted a Jr(a+w) phenotype. Crossmatch tests confirmed the compatibility of blood from the patient's son, which was used to address the urgent blood requirement. Later, rare blood from a Jr(a-) donor from the Guangzhou Blood Center was used for the patient's ongoing treatment, saving the patient's life.
CONCLUSION
Combining classic serological testing with blood group gene typing techniques successfully identified the rare Jr(a-) blood type and high-frequency anti-Jra antibodies. Enzyme-treated red blood cell identification methods confirmed the presence of anti-Jra antibodies. By searching within the family and seeking help from other blood centers, compatible blood was found. This approach may provide insights for resolving similar complex blood matching problems in the future.
Humans
;
Blood Grouping and Crossmatching/methods*
;
Blood Group Antigens/immunology*
;
Blood Transfusion
;
Male
;
Isoantibodies/blood*
;
Female
;
Genotype
10.Effect of variants in the non-coding region of ABO blood group alleles on the weak expression of antigens.
Hua WANG ; Yunxiang WU ; Fei WANG ; Yajun LIANG ; Qing LI ; Jiangtao ZUO ; Yi XU ; Zhicheng LI ; Ruiqing GUO ; Xin ZHANG ; Demei ZHANG
Chinese Journal of Medical Genetics 2025;42(5):628-632
OBJECTIVE:
To explore the regulatory mechanisms underlying the weak expression of ABO blood group antigens due to variants in the non-coding regions of the ABO gene.
METHODS:
From June 2014 to October 2023, a total of 29 samples from the Taiyuan Blood Center and local hospitals, which were serologically identified as having weak ABO antigen expression without detectable coding region mutations, were selected for this study. Full-length ABO gene sequencing was performed using third-generation long-read sequencing technology (Pacific Biosciences) to obtain complete haplotype sequences of the ABO gene. Variants in the non-coding regions were compared and identified to infer their regulatory effects on weak antigen expression. The procedures followed in this study were in accordance with the ethical standards of the World Medical Association's Declaration of Helsinki (2013 revision). The Medical Ethics Committee of Taiyuan Blood Center has granted an exemption from ethical review.
RESULTS:
18 bp deletions in the -35 to -18 region of the promoter were identified in 7 samples. Variants in intron 1 (+5.8 kb) were detected in 7 samples, including ABO*A (28+5792_5793delCT (1 case) and ABO*B (28+5793T>C) located in the GATA binding region; ABO*B (28+5808C>T) (1 case) in the E-box region; and ABO*B (28+5875C>T) (4 cases) in the RUNX1 binding region. Nucleotide variants at splice sites were detected in 2 samples, namely ABO*B (C.98+1G>A) and ABO*B (C.204-2A>C).
CONCLUSION
Variants in the non-coding regulatory sequences of the ABO gene are a significant factor contributing to weak ABO antigen expression. In clinical ABO sequencing, it is essential to screen not only the conventional coding regions but also the flanking sequences, introns, and splice sites of the ABO gene to facilitate precise blood transfusion.
ABO Blood-Group System/genetics*
;
Humans
;
Alleles
;
Promoter Regions, Genetic
;
Haplotypes
;
Introns

Result Analysis
Print
Save
E-mail