1.Subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets
Qiu-jin QU ; Ling-xiao SUN ; Xiao-fei WANG ; Fu-yu ZHU ; Guo-xi CHE ; Jing XU ; Xiao-yan WANG ; Nai-shui HAN ; Xiao-xia SUN ; Chun-xia QIAO
Chinese Medical Equipment Journal 2025;46(10):29-35
Objective To evaluate the subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets using hydroxyethyl starch(HES)130/0.4 sodium chloride injection as an extraction medium.Methods Firstly,40 Sprague Dawley(SD)rats including 20 male and 20 female ones were seleted and randomly enrolled into a sample group and a control group by sex,with 20 ones in each group.Secondly,instead of plasma HES 130/0.4 sodium chloride injection was used to leach disposable plasma virus-inactivated blood transfusion sets to prepare the test solution by simulating clinical application such as lighting,adsorption and filtration and storage.Finally,the test solution and HES 130/0.4 sodium chloride injection were injected into the tail vein of the SD rats at a dose of 20 mL/kg for 28 d in the sample group and in the control group respectively,and the subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets and the feasibility of using HES 130/0.4 sodium chloride injection as the extraction medium to assess their subchronic systemic toxicity were evaluated with clinical observation,body mass monitoring,clinical pathology examination,gross necropsy and histopathology examination.Results The sample group and control group had no significant differences in mortality rates,clinical observation results,body mass,gross necropsy results,hematological and coagulation examination results and organ weight(all P>0.05);blood biochemical examinations showed the male rats in the sample group had the cholesterol(CHO)values higher while the creatinine(CR)values lower than those in the control group,with the differences being statistically significant(both P<0.05)and the two indexes within the range of the laboratory's historical reference data,and other blood biochemical indexes were not significantly different(all P>0.05);the sample group had the spleen weight-to-body mass ratios of the female rates lower significantly than those in the control group(P<0.05),and the ratios of other organ weight to body mass had significant differences(all P>0.05);histopathology examination showed slight pathological changes in liver,spleen and kidney of female rats and in spleen and kidney of male rats in the sample group,and the female and male rats in the control group had similar pathological changes found in the sample group,which might be caused by HES metabolites.Conclusion Disposable plasma virus-inactivated blood transfusion sets prove to have no significant subchronic systemic toxicity,and its feasible to use HES 130/0.4 sodium chloride injection as the extraction medium to evaluate the subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets.[Chinese Medical Equipment Journal,2025,46(10):29-35]
2.Expert consensus on infection prevention and control of Creutzfeldt-Jakob disease in medical institutions
Tianxiang GE ; Yangyang JIA ; Chunhui LI ; Jianrong HUANG ; Xiujuan MENG ; Xiaodong GAO ; Jingping ZHANG ; Fu QIAO ; Lijuan XIONG ; Hui LIANG ; Wei LI ; Haiyan LOU ; Wenjuan WU ; Tianxin XIANG ; Jiansen CHEN ; Biao ZHU ; Kaijin XU ; Zhihui ZHOU ; Hongliu CAI ; Meihong YU ; Yan ZHANG ; Yanwan SHANGGUAN ; Haiting FENG ; Hangping YAO ; Lei GUO ; Tieer GAN ; Weihong ZHANG ; Jimin SUN ; Ye LU ; Qun LU ; Meng CAI ; Jin SHEN ; Yunsong YU ; Anhua WU ; Liu-yi LI ; Tingting QU
Chinese Journal of Infection Control 2025;24(4):437-450
Creutzfeldt-Jakob disease(CJD)is a rapidly progressive and fatal neurodegenerative disorder caused by prions,with certain infectivity and iatrogenic transmission risks.With the rapid progress and application of new dia-gnostic biomarkers and detection methods,as well as the construction and improvement of surveillance and reporting systems,the detection of CJD in patients domestically and internationally has shown an increasing trend year by year.Due to its long incubation period and heterogeneity of early symptoms,early identification and diagnosis of the disease is difficult,increasing the risk of transmission within medical institutions.Currently,there is a lack of con-sensus on the infection prevention and control of CJD.In order to timely identify and diagnose CJD as well as effec-tively block its transmission in medical institutions,this consensus summarizes 15 clinical concerns and formulates 24 specific recommendations based on the latest domestic and international research findings and clinical evidence,as well as combines with clinical practice,aiming to standardize healthcare-associated infection prevention and control measures for CJD and reduce its transmission risk in medical institutions.
3.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]
4.Expert consensus on infection prevention and control of Creutzfeldt-Jakob disease in medical institutions
Tianxiang GE ; Yangyang JIA ; Chunhui LI ; Jianrong HUANG ; Xiujuan MENG ; Xiaodong GAO ; Jingping ZHANG ; Fu QIAO ; Lijuan XIONG ; Hui LIANG ; Wei LI ; Haiyan LOU ; Wenjuan WU ; Tianxin XIANG ; Jiansen CHEN ; Biao ZHU ; Kaijin XU ; Zhihui ZHOU ; Hongliu CAI ; Meihong YU ; Yan ZHANG ; Yanwan SHANGGUAN ; Haiting FENG ; Hangping YAO ; Lei GUO ; Tieer GAN ; Weihong ZHANG ; Jimin SUN ; Ye LU ; Qun LU ; Meng CAI ; Jin SHEN ; Yunsong YU ; Anhua WU ; Liu-yi LI ; Tingting QU
Chinese Journal of Infection Control 2025;24(4):437-450
Creutzfeldt-Jakob disease(CJD)is a rapidly progressive and fatal neurodegenerative disorder caused by prions,with certain infectivity and iatrogenic transmission risks.With the rapid progress and application of new dia-gnostic biomarkers and detection methods,as well as the construction and improvement of surveillance and reporting systems,the detection of CJD in patients domestically and internationally has shown an increasing trend year by year.Due to its long incubation period and heterogeneity of early symptoms,early identification and diagnosis of the disease is difficult,increasing the risk of transmission within medical institutions.Currently,there is a lack of con-sensus on the infection prevention and control of CJD.In order to timely identify and diagnose CJD as well as effec-tively block its transmission in medical institutions,this consensus summarizes 15 clinical concerns and formulates 24 specific recommendations based on the latest domestic and international research findings and clinical evidence,as well as combines with clinical practice,aiming to standardize healthcare-associated infection prevention and control measures for CJD and reduce its transmission risk in medical institutions.
5.Subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets
Qiu-jin QU ; Ling-xiao SUN ; Xiao-fei WANG ; Fu-yu ZHU ; Guo-xi CHE ; Jing XU ; Xiao-yan WANG ; Nai-shui HAN ; Xiao-xia SUN ; Chun-xia QIAO
Chinese Medical Equipment Journal 2025;46(10):29-35
Objective To evaluate the subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets using hydroxyethyl starch(HES)130/0.4 sodium chloride injection as an extraction medium.Methods Firstly,40 Sprague Dawley(SD)rats including 20 male and 20 female ones were seleted and randomly enrolled into a sample group and a control group by sex,with 20 ones in each group.Secondly,instead of plasma HES 130/0.4 sodium chloride injection was used to leach disposable plasma virus-inactivated blood transfusion sets to prepare the test solution by simulating clinical application such as lighting,adsorption and filtration and storage.Finally,the test solution and HES 130/0.4 sodium chloride injection were injected into the tail vein of the SD rats at a dose of 20 mL/kg for 28 d in the sample group and in the control group respectively,and the subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets and the feasibility of using HES 130/0.4 sodium chloride injection as the extraction medium to assess their subchronic systemic toxicity were evaluated with clinical observation,body mass monitoring,clinical pathology examination,gross necropsy and histopathology examination.Results The sample group and control group had no significant differences in mortality rates,clinical observation results,body mass,gross necropsy results,hematological and coagulation examination results and organ weight(all P>0.05);blood biochemical examinations showed the male rats in the sample group had the cholesterol(CHO)values higher while the creatinine(CR)values lower than those in the control group,with the differences being statistically significant(both P<0.05)and the two indexes within the range of the laboratory's historical reference data,and other blood biochemical indexes were not significantly different(all P>0.05);the sample group had the spleen weight-to-body mass ratios of the female rates lower significantly than those in the control group(P<0.05),and the ratios of other organ weight to body mass had significant differences(all P>0.05);histopathology examination showed slight pathological changes in liver,spleen and kidney of female rats and in spleen and kidney of male rats in the sample group,and the female and male rats in the control group had similar pathological changes found in the sample group,which might be caused by HES metabolites.Conclusion Disposable plasma virus-inactivated blood transfusion sets prove to have no significant subchronic systemic toxicity,and its feasible to use HES 130/0.4 sodium chloride injection as the extraction medium to evaluate the subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets.[Chinese Medical Equipment Journal,2025,46(10):29-35]
6.Identification and expression analysis of AP2/ERF family members in Lonicera macranthoides.
Si-Min ZHOU ; Mei-Ling QU ; Juan ZENG ; Jia-Wei HE ; Jing-Yu ZHANG ; Zhi-Hui WANG ; Qiao-Zhen TONG ; Ri-Bao ZHOU ; Xiang-Dan LIU
China Journal of Chinese Materia Medica 2025;50(15):4248-4262
The AP2/ERF transcription factor family is a class of transcription factors widely present in plants, playing a crucial role in regulating flowering, flower development, flower opening, and flower senescence. Based on transcriptome data from flower, leaf, and stem samples of two Lonicera macranthoides varieties, 117 L. macranthoides AP2/ERF family members were identified, including 14 AP2 subfamily members, 61 ERF subfamily members, 40 DREB subfamily members, and 2 RAV subfamily members. Bioinformatics and differential gene expression analyses were performed using NCBI, ExPASy, SOMPA, and other platforms, and the expression patterns of L. macranthoides AP2/ERF transcription factors were validated via qRT-PCR. The results indicated that the 117 LmAP2/ERF members exhibited both similarities and variations in protein physicochemical properties, AP2 domains, family evolution, and protein functions. Differential gene expression analysis revealed that AP2/ERF transcription factors were primarily differentially expressed in the flowers of the two L. macranthoides varieties, with the differentially expressed genes mainly belonging to the ERF and DREB subfamilies. Further analysis identified three AP2 subfamily genes and two ERF subfamily genes as potential regulators of flower development, two ERF subfamily genes involved in flower opening, and two ERF subfamily genes along with one DREB subfamily gene involved in flower senescence. Based on family evolution and expression analyses, it is speculated that AP2/ERF transcription factors can regulate flower development, opening, and senescence in L. macranthoides, with ERF subfamily genes potentially serving as key regulators of flowering duration. These findings provide a theoretical foundation for further research into the specific functions of the AP2/ERF transcription factor family in L. macranthoides and offer important theoretical insights into the molecular mechanisms underlying floral phenotypic differences among its varieties.
Plant Proteins/chemistry*
;
Gene Expression Regulation, Plant
;
Transcription Factors/chemistry*
;
Lonicera/classification*
;
Flowers/metabolism*
;
Phylogeny
;
Gene Expression Profiling
;
Multigene Family
7.Cost-effectiveness of angiographic quantitative flow ratio-guided coronary intervention: A multicenter, randomized, sham-controlled trial.
Yanyan ZHAO ; Changdong GUAN ; Yang WANG ; Zening JIN ; Bo YU ; Guosheng FU ; Yundai CHEN ; Lijun GUO ; Xinkai QU ; Yaojun ZHANG ; Kefei DOU ; Yongjian WU ; Weixian YANG ; Shengxian TU ; Javier ESCANED ; William F FEARON ; Shubin QIAO ; David J COHEN ; Harlan M KRUMHOLZ ; Bo XU ; Lei SONG
Chinese Medical Journal 2025;138(10):1186-1193
BACKGROUND:
The FAVOR (Comparison of Quantitative Flow Ratio Guided and Angiography Guided Percutaneous Intervention in Patients with Coronary Artery Disease) III China trial demonstrated that percutaneous coronary intervention (PCI) lesion selection using quantitative flow ratio (QFR) measurement, a novel angiography-based approach for estimating fractional flow reserve, improved two-year clinical outcomes compared with standard angiography guidance. This study aimed to assess the cost-effectiveness of QFR-guided PCI from the perspective of the current Chinese healthcare system.
METHODS:
This study is a pre-specified analysis of the FAVOR III China trial, which included 3825 patients randomized between December 25, 2018, and January 19, 2020, from 26 centers in China. Patients with stable or unstable angina pectoris or those ≥72 hours post-myocardial infarction who had at least one lesion with a diameter stenosis between 50% and 90% in a coronary artery with a ≥2.5 mm reference vessel diameter by visual assessment were randomized to a QFR-guided strategy or an angiography-guided strategy with 1:1 ratio. During the two-year follow-up, data were collected on clinical outcomes, quality-adjusted life-years (QALYs), estimated costs of index procedure hospitalization, outpatient cardiovascular medication use, and rehospitalization due to major adverse cardiac and cerebrovascular events (MACCE). The primary analysis calculated the incremental cost-effectiveness ratio (ICER) as the cost per MACCE avoided. An ICER of ¥10,000/MACCE event avoided was considered economically attractive in China.
RESULTS:
At two years, the QFR-guided group demonstrated a reduced rate of MACCE compared to the angiography-guided group (10.8% vs . 14.7%, P <0.01). Total two-year costs were similar between the groups (¥50,803 ± 21,121 vs . ¥50,685 ± 23,495, P = 0.87). The ICER for the QFR-guided strategy was ¥3055 per MACCE avoided, and the probability of QFR being economically attractive was 64% at a willingness-to-pay threshold of ¥10,000/MACCE avoided. Sensitivity analysis showed that QFR-guided PCI would become cost-saving if the cost of QFR were below ¥3682 (current cost: ¥3800). Cost-utility analysis yielded an ICER of ¥56,163 per QALY gained, with a 53% probability of being cost-effective at a willingness-to-pay threshold of ¥85,000 per QALY gained.
CONCLUSION:
In patients undergoing PCI, a QFR-guided strategy appears economically attractive compared to angiographic guidance from the perspective of the Chinese healthcare system.
TRIAL REGISTRATION
ClinicalTrials.gov , NCT03656848.
Humans
;
Cost-Benefit Analysis
;
Percutaneous Coronary Intervention/methods*
;
Male
;
Female
;
Coronary Angiography/methods*
;
Middle Aged
;
Aged
;
Coronary Artery Disease/surgery*
;
Quality-Adjusted Life Years
;
Fractional Flow Reserve, Myocardial/physiology*
8.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]
9.Diagnostic efficiency evaluation of isolated-check visual evoked potential on primary open-angle glaucoma
Qiao YU ; Xin LIU ; Qian HU ; Wanning LIU ; Bo QU
Journal of China Medical University 2024;53(10):934-938
Objective To evaluate the accuracy,sensitivity,and specificity of isolated-check visual evoked potential(Ic-VEP)in the diagnosis of primary open-angle glaucoma(POAG).Methods The participants were 52 patients(104 eyes)with POAG and 40 healthy controls(80 eyes).All participants were examined using Ic-VEP and Humphrey perimetry to record the signal-to-noise ratio and mean devia-tion.Receiver operating characteristic(ROC)curve analysis was used to characterize the diagnostic performance of Ic-VEP in POAG.Results The sensitivity,specificity,and accuracy of the Ic-VEP qualitative examination were 92.3%,80.0%,and 88.0%,respectively.The area under the curve(AUC)was 0.873(95%CI:0.793-0.953).The sensitivity,specificity,and accuracy of the Ic-VEP quantitative examination were 91.3%,81.3%,and 87.0%,respectively.The AUC was 0.863(95%CI:0.804-0.922).The sensitivity of Ic-VEP in the early stage of POAG(81.3%)was slightly lower than that in the middle and late stages(82.0%),but the difference was not statisti-cally significant(x 2=0.001,P=0.981).The sensitivity of Ic-VEP quantitative examination in the early stage of POAG(88.4%)was slightly lower than that in the middle and late stages(93.4%);however,the difference was not statistically significant(x2=0.037,P=0.847).Conclusion Ic-VEP is an effective diagnostic instrument for middle-late and early stages of POAG.
10.Research progress and maturity assessment of continuous manufacturing of traditional Chinese medicine.
Zi-Chen LIANG ; Xue-Fang TANG ; Ping YANG ; Ju SONG ; Zhao-Zhou LIN ; Xiang XU ; Yan-Lin QIN ; Yan-Yu BAO ; Zhi-Qiang ZHANG ; Xin ZHANG ; Jian-Bo QU ; Yan-Jiang QIAO ; Bing XU
China Journal of Chinese Materia Medica 2023;48(12):3162-3168
The pharmaceutical manufacturing model is gradually changing from intermittent manufacturing to continuous manufacturing and intelligent manufacturing. This paper briefly reviewed the supervision and research progress in continuous pharmaceutical manufacturing in China and abroad and described the definition and advantages of continuous pharmaceutical manufacturing. The continuous manufacturing of traditional Chinese medicine(TCM) at the current stage was summarized in the following three terms: the enhancement of the continuity of intermittent manufacturing operations, the integration of continuous equipment to improve physical continuity between units, and the application of advanced process control strategies to improve process continuity. To achieve continuous manufacturing of TCM, the corresponding key technologies, such as material property characterization, process modeling and simulation, process analysis technology, and system integration, were analyzed from the process and equipment, respectively. It was proposed that the continuous manufacturing equipment system should have the characteristics of high speed, high response, and high reliability, "three high(H~3)" for short. Considering the characteristics and current situation of TCM manufacturing, based on the two dimensions of product quality control and production efficiency, a maturity assessment model for continuous manufacturing of TCM, consisting of operation continuity, equipment continuity, process continuity, and quality control continuity, was proposed to provide references for the application of continuous manufacturing technology for TCM. The implementation of continuous manufacturing or the application of key continuous manufacturing technologies in TCM can help to systematically integrate advanced pharmaceutical technology elements and promote the uniformity of TCM quality and the improvement of production efficiency.
Medicine, Chinese Traditional
;
Reproducibility of Results
;
China
;
Quality Control
;
Pharmaceutical Preparations

Result Analysis
Print
Save
E-mail