1.Distribution characteristics of self-reported diseases and occupational injuries among workers in manufacturing enterprises
Lin ZHANG ; Zhi’an LI ; Yishuo GU ; Juan QIAN ; Chunhua LU ; Jianjian QIAO ; Yong QIAN ; Zeyun YANG ; Xiaojun ZHU
Journal of Environmental and Occupational Medicine 2025;42(2):165-170
Background Diseases severely affect the efficiency of workers. Comorbidity refers to the coexistence of two or more chronic diseases or health problems in the same individual. Previous studies have primarily focused on occupational injuries caused by environmental exposures, while the analysis of the epidemiological characteristics of self-reported diseases and occupational injuries among manufacturing workers has been insufficient. Objective To analyze the distribution of self-reported diseases and occupational injuries among manufacturing workers, the strength of correlation between different diseases, and common disease combinations, and to preliminarily explore the relationship between self-reported diseases and occupational injuries. Methods A cross-sectional survey was conducted to investigate the occupational injuries of
2.An alkyne and two phenylpropanoid derivants from Carthamus tinctorius L.
Lin-qing QIAO ; Ge-ge XIA ; Ying-jie LI ; Wen-xuan ZHAO ; Yan-zhi WANG
Acta Pharmaceutica Sinica 2025;60(1):185-190
The chemical constituents from the
3.Clinical trial of spironolactone combined with sacubitril/valsartan in the treatment of patients with hypertensive nephropathy
Lin-Lin WANG ; Jia-Li FENG ; Sheng-Jun LIU ; Zhen-Hua QIAO ; Xiu-Ling JIA ; Xiao-Li HAN
The Chinese Journal of Clinical Pharmacology 2024;40(8):1091-1095
Objective To observe the clinical efficacy and safety of spironolactone combined with sacubitril/valsartan in the treatment of patients with hypertensive nephropathy.Methods The patients with hypertensive nephropathy were randomly divided into control group and treatment group.The control group was treated with sacubitril/valsartan(100-200 mg·d-1 in the morning),and treatment group was combined with low-dose spironolactone treatment(20 mg·d-1 in the morning)on the basis of control group.Both groups were treated continuously for 12 weeks.The clinical efficacy was compared;the blood pressure,urinary microalbumin(mAlb),urinary β2 microglobulin(β2-MG)and serum cystatin C(Cys-C),transforming growth factor-β1(TGF-β1),connective tissue growth factor(CTGF)and angiotensin Ⅱ(Ang Ⅱ)and adverse drug reactions were observed before and after treatment.Results There were 87 cases in treatment group and 86 cases in control group were included respectively.After treatment,the total effective rates in treatment group and control group were 95.40%(83 cases/87 cases)and 82.56%(71 cases/86 cases),with significant difference(P<0.05).After treatment,the systolic blood pressure values in treatment group and control group were(124.65±9.65)and(130.27±8.93)mmHg,the diastolic blood pressure values were(75.08±7.14)and(80.45±7.35)mmHg,urinary mAlb levels were(42.58±5.65)and(51.28±6.64)mg·L-1,urinary β2-MG levels were(0.46±0.17)and(0.75±0.25)mg·L-1,24 h urinary protein quantitation levels were(138.49±46.64)and(216.48±65.27)mg,serum Cys-C levels were(0.63±0.26)and(0.85±0.24)mg·L-1,TGF-β1 levels were(98.67±21.43)and(112.46±26.72)pg·mL-1,CTGF levels were(1 206.54±236.56)and(1 340.51±248.25)pg·mL-1,Ang Ⅱ levels were(101.55±17.62)and(115.65±20.08)pg·mL-1,all with significant difference(all P<0.05).The incidence of adverse drug reactions in treatment group and control group were 6.90%(6 cases/87 cases)and 2.33%(2 cases/86 cases),with no significant difference(P>0.05).Conclusion Compared with sacubitril/valsartan alone,spironolactone combined with sacubitril/valsartan can better reduce blood pressure,improve renal function and delay progression of renal fibrosis in the treatment of hypertensive nephropathy,and has definite efficacy,with good safety.
4.Research progress of large-scale brain network of Alzheimer's disease based on MRI analysis
Ying-Mei HAN ; Yijie LI ; Heng ZHANG ; Jing LV ; Yi ZHANG ; Yingbo QIAO ; Nan LIN ; Huiyong XU ; Feng WANG
The Journal of Practical Medicine 2024;40(4):575-579
With the advent of an aging society,Alzheimer's disease(AD)has gradually become a major ailment affecting the elderly.AD is a neurodegenerative disorder associated with cognitive impairments.In AD patients,brain network connections are disrupted,and their topological properties are also affected,leading to the disintegration of anatomical and functional connections.Anatomical connections can be tracked and evaluated using structural magnetic imaging(MRI)and diffusion tensor imaging(DTI),while functional connections are detected through functional MRI to assess their connectivity status.This review incorporates the findings of previous scholars and summarizes the current research of AD.It mainly discusses the imaging characteristics of large-scale brain network changes in AD patients,so as to provide researchers with scientific and objective imaging markers for AD prediction and early diagnosis,as well as future research.
5.Classification research of TCM pulse conditions based on multi-label voice analysis
Haoran Shen ; Junjie Cao ; Lin Zhang ; Jing Li ; Jianghong Liu ; Zhiyuan Chu ; Shifeng Wang ; Yanjiang Qiao
Journal of Traditional Chinese Medical Sciences 2024;11(2):172-179
Objective:
To explore the feasibility of remotely obtaining complex information on traditional Chinese medicine (TCM) pulse conditions through voice signals.
Methods:
We used multi-label pulse conditions as the entry point and modeled and analyzed TCM pulse diagnosis by combining voice analysis and machine learning. Audio features were extracted from voice recordings in the TCM pulse condition dataset. The obtained features were combined with information from tongue and facial diagnoses. A multi-label pulse condition voice classification DNN model was built using 10-fold cross-validation, and the modeling methods were validated using publicly available datasets.
Results:
The analysis showed that the proposed method achieved an accuracy of 92.59% on the public dataset. The accuracies of the three single-label pulse manifestation models in the test set were 94.27%, 96.35%, and 95.39%. The absolute accuracy of the multi-label model was 92.74%.
Conclusion
Voice data analysis may serve as a remote adjunct to the TCM diagnostic method for pulse condition assessment.
6.Comparison on Quality of Honey Processed Lilii Bulbus Prepared by Traditional Empirical and Pharmacopoeial Methods Based on Chemical Analysis and Sensory Techniques
Juanjuan ZHU ; Li LIN ; Qiao ZHOU ; Qi LU ; Yanpeng DAI ; Dianhua SHI
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(19):198-205
ObjectiveTo compare the quality of two kinds of honey-processed Lilii Bulbus(HPLB) prepared by empirical and pharmacopoeial methods based on chemical analysis and intelligent sensory technology, and to improve and upgrade the quality standard of HPLB on the basis of excavating and inheriting the traditional experience of famous experts in traditional Chinese medicine(TCM). MethodSamples of HPLB were prepared according to the method in the 2020 edition of Chinese Pharmacopoeia(honey was added before frying) and the empirical method of the old pharmacists(honey was added after frying), and the appearance characteristics, thin layer chromatography(TLC) identification, inspection, leachables and other items of the two kinds of samples were detected according to the methods under the Lilii Bulbus in the 2020 edition of Chinese Pharmacopoeia. The fingerprints of HPLB with different honey addition methods were established by high performance liquid chromatography(HPLC), and the contents of regaloside A, regaloside B and 5-hydroxymethylfurfural(5-HMF) were determined, the quality difference between the two HPLB samples was evaluated by multivariate statistical analysis. Meanwhile, electronic nose and electronic tongue were used to measure the sense of smell and taste, and combined with multivariate statistical analysis, the difference sensors were screened with the variable importance in the projection(VIP) value>1 in order to compare the differences between the two kinds of HPLB. ResultCompared with HPLB prepared by the pharmacopoeial method, the sample prepared by the empirical method had lower water content, slightly higher soluble extract content, better appearance and easy storage. HPLC fingerprints of two kinds of HPLB samples were established, and the similarity between them was≥0.999, indicating that the composition of two species was similar. And 29 common peaks were calibrated, among which peaks 8 and 18 were regaloside A and regaloside B. The quantitative analysis of the index components in the two kinds of HPLB samples showed that the difference in the contents of regaloside A and regaloside B was not statistically significant, whereas the content of 5-HMF in empirical HPLB was significantly higher than that of the pharmacopoeial HPLB(P<0.01). The electronic tongue and electronic nose test results showed that the umami, umami richness and saltiness of the empirical HPLB were higher than those of the pharmacopoeial HPLB. The results of electronic nose detection showed that the four sensors W1W, W2S, W5S and W1S were the differential odor sensors of the two samples, among which the response values of W1S and W2S sensors were higher than those of the pharmacopoeial HPLB, which might be related to the content of 5-HMF. ConclusionCompared with the pharmacopoeial HPLB, the empirical sample is of better quality, but the two can be clearly distinguished by electronic nose and electronic tongue, which can provide a reference for excavating and inheriting the traditional experience of famous experts in TCM and further improving the processing methods and quality standards of HPLB.
7.Distribution of platelet antibodies and their specificity in Zhongshan area
Huiyan LIN ; Yonglun WU ; Ainong SUN ; Yuru FANG ; Qianying CHEN ; Qiao LI ; Yujue WANG ; Hongmei WANG ; Zhizhao YANG ; Xiaoyi JIAN ; Xianguo XU ; Shengbao DUAN
Chinese Journal of Blood Transfusion 2024;37(1):63-67
【Objective】 To investigate the frequency of platelet antibodies in voluntary blood donors and patients in Zhongshan, Guangdong Province, and to study the specificity and cross-matching of platelet antibodies. 【Methods】 Platelet antibodies of blood donors and patients were screened by solid-phase immunoadsorption (SPIA), rechecked by flow cytometry (FCM), and antibody specificity was identified by PakPlus enzyme immunoassay, and platelet cross-matching was simulated by SPIA. 【Results】 A total of 1 049 blood donor samples and 598 patient samples were tested, with 6 (0.57%) and 49 (8.19%) samples positive for SPIA,respectively(P<0.05); In SPIA positive samples, the positive concordance rate of FCM in blood donors and patients was 100% vs 95%, and that of enzyme immunoassay was 100% vs 88%. Among the initial screening positive samples of blood donors, 5 were anti-HLA Ⅰ antibodies, accounting for 83%, and 1 was anti CD36 antibody, accounting for 17%, with an incidence rate of 0.10%. Among the 14 samples of enzyme immunoassay positive patients, 2 were anti-GP Ⅱb/Ⅲa, 1 was anti-GP Ⅱa/Ⅱa, 8 were anti HLA Ⅰ, and 3 were mixed antibodies (HLA Ⅰ, GP Ⅱb/Ⅲa, GP Ⅰa/Ⅱa). According to the types of antibodies, HLA Ⅰ antibodies were the most common, accounting for 65% (11/17), followed by HPA related anti GP, accounting for 35% (6/17). The majority of patients had a platelet antibody positive typing rate below 30%, accounting for 71.4% (10/14). 【Conclusions】 The positive rate of platelet antibody of patients in Zhongshan area is significantly higher than that of voluntary blood donors, and most of them are anti-HLA Ⅰ and anti-GP, and the incidence of anti-CD36 is extremely low. Therefore, it is necessary to establish a known platelet antigen donor bank, and at the same time, carry out platelet antibody testing and matching of patients, which is helpful to solve the issue of platelet transfusion refractoriness.
8.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
9.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
10.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.


Result Analysis
Print
Save
E-mail