1.Mechanism of vanillic acid against cardiac fibrosis induced by isoproterenol in mice based on Drp1/HK1/NLRP3 and mitochondrial apoptosis signaling pathways.
Hai-Bo HE ; Mian WU ; Jie XU ; Qian-Qian XU ; Fang-Zhu WAN ; Hua-Qiao ZHONG ; Ji-Hong ZHANG ; Gang ZHOU ; Hui-Lin QIN ; Hao-Ran LI ; Hai-Ming TANG
China Journal of Chinese Materia Medica 2025;50(8):2193-2208
This study investigated the effects and underlying mechanisms of vanillic acid(VA) against cardiac fibrosis(CF) induced by isoproterenol(ISO) in mice. Male C57BL/6J mice were randomly divided into control group, VA group(100 mg·kg~(-1), ig), ISO group(10 mg·kg~(-1), sc), ISO + VA group(10 mg·kg~(-1), sc + 100 mg·kg~(-1), ig), ISO + dynamin-related protein 1(Drp1) inhibitor(Mdivi-1) group(10 mg·kg~(-1), sc + 50 mg·kg~(-1), ip), and ISO + VA + Mdivi-1 group(10 mg·kg~(-1), sc + 100 mg·kg~(-1), ig + 50 mg·kg~(-1), ip). The treatment groups received the corresponding medications once daily for 14 consecutive days. On the day after the last administration, cardiac functions were evaluated, and serum and cardiac tissue samples were collected. These samples were analyzed for serum aspartate aminotransferase(AST), lactate dehydrogenase(LDH), creatine kinase-MB(CK-MB), cardiac troponin I(cTnI), reactive oxygen species(ROS), interleukin(IL)-1β, IL-4, IL-6, IL-10, IL-18, and tumor necrosis factor-α(TNF-α) levels, as well as cardiac tissue catalase(CAT), glutathione(GSH), malondialdehyde(MDA), myeloperoxidase(MPO), superoxide dismutase(SOD), total antioxidant capacity(T-AOC) activities, and cytochrome C levels in mitochondria and cytoplasm. Hematoxylin-eosin, Masson, uranium acetate and lead citrate staining were used to observe morphological and mitochondrial ultrastructural changes in the cardiac tissues, and myocardial injury area and collagen volume fraction were calculated. Flow cytometry was applied to detect the relative content and M1/M2 polarization of cardiac macrophages. The mRNA expression levels of macrophage polarization markers [CD86, CD206, arginase 1(Arg-1), inducible nitric oxide synthase(iNOS)], CF markers [type Ⅰ collagen(Coll Ⅰ), Coll Ⅲ, α-smooth muscle actin(α-SMA)], and cytokines(IL-1β, IL-4, IL-6, IL-10, IL-18, TNF-α) in cardiac tissues were determined by quantitative real-time PCR. Western blot was used to detect the protein expression levels of Coll Ⅰ, Coll Ⅲ, α-SMA, Drp1, p-Drp1, voltage-dependent anion channel(VDAC), hexokinase 1(HK1), NOD-like receptor protein 3(NLRP3), apoptosis-associated speck-like protein(ASC), caspase-1, cleaved-caspase-1, gasdermin D(GSDMD), cleaved N-terminal gasdermin D(GSDMD-N), IL-1β, IL-18, B-cell lymphoma-2(Bcl-2), B-cell lymphoma-xl(Bcl-xl), Bcl-2-associated death promoter(Bad), Bcl-2-associated X protein(Bax), apoptotic protease activating factor-1(Apaf-1), pro-caspase-3, cleaved-caspase-3, pro-caspase-9, cleaved-caspase-9, poly(ADP-ribose) polymerase-1(PARP-1), and cleaved-PARP-1 in cardiac tissues. The results showed that VA significantly improved cardiac function in mice with CF, reduced myocardial injury area and cardiac index, and decreased serum levels of AST, CK-MB, cTnI, LDH, ROS, IL-1β, IL-6, IL-18, and TNF-α. VA also lowered MDA and MPO levels, mRNA expressions of IL-1β, IL-6, IL-18, and TNF-α, and mRNA and protein expressions of Coll Ⅰ, Coll Ⅲ, and α-SMA in cardiac tissues, and increased serum levels of IL-4 and IL-10, cardiac tissue levels of CAT, GSH, SOD, and T-AOC, and mRNA expressions of IL-4 and IL-10. Additionally, VA ameliorated cardiac pathological damage, inhibited myocardial cell apoptosis, inflammatory infiltration, and collagen fiber deposition, reduced collagen volume fraction, and alleviated mitochondrial damage. VA decreased the ratio of F4/80~+CD86~+ M1 cells and the mRNA expressions of CD86 and iNOS in cardiac tissue, and increased the ratio of F4/80~+CD206~+ M2 cells and the mRNA expressions of CD206 and Arg-1. VA also reduced protein expressions of p-Drp1, VDAC, NLRP3, ASC, caspase-1, cleaved-caspase-1, GSDMD, GSDMD-N, IL-1β, IL-18, Bad, Bax, Apaf-1, cleaved-caspase-3, cleaved-caspase-9, cleaved-PARP-1, and cytoplasmic cytochrome C, and increased the expressions of HK1, Bcl-2, Bcl-xl, pro-caspase-3, pro-caspase-9 proteins, as well as the Bcl-2/Bax and Bcl-xl/Bad ratios and mitochondrial cytochrome C content. These results indicate that VA has a significant ameliorative effect on ISO-induced CF in mice, alleviates ISO-induced oxidative damage and inflammatory response, and its mechanism may be closely related to the inhibition of Drp1/HK1/NLRP3 and mitochondrial apoptosis signaling pathways, suppression of myocardial cell inflammatory infiltration and collagen fiber deposition, reduction of collagen volume fraction and CollⅠ, Coll Ⅲ, and α-SMA expressions, thus mitigating CF.
Animals
;
Isoproterenol/adverse effects*
;
Male
;
Mice
;
Signal Transduction/drug effects*
;
Vanillic Acid/administration & dosage*
;
Dynamins/genetics*
;
Mice, Inbred C57BL
;
Fibrosis/genetics*
;
Apoptosis/drug effects*
;
Mitochondria/metabolism*
;
NLR Family, Pyrin Domain-Containing 3 Protein/genetics*
;
Myocardium/metabolism*
;
Humans
2.Clinical efficacy of Wenshen Chushi Decoction combined with LIPUS on erectile dysfunction with renal deficiency and phlegm-dampness syndrome.
Wen-Xiong ZHU ; Yi-Feng YUAN ; Tao LIU ; Bo LI ; Liu-Ya LONG ; Qi-Hua CHEN ; Ju-Qiao HE
National Journal of Andrology 2025;31(6):519-525
OBJECTIVE:
To explore the clinical efficacy of Wenshen Chushi Decoction combined with low intensity pulsed ultrasound (LIPUS) on erectile dysfunction (ED) caused by renal deficiency and phlegm-dampness syndrome.
METHODS:
One hundred and twenty ED patients were included from the Department of Andrology in the First Hospital of Hunan University of Traditional Chinese Medicine. The patients in control group were treated with Wenshen Chushi Decoction. While the patients in observation group were treated with Wenshen Chushi Decoction combined with LIPUS for 8 consecutive weeks. After the treatment, the efficacy was evaluated using the International Index of Erectile Function-5 (IIEF-5) score, Penile Flow Index (PFI), Traditional Chinese Medicine Syndrome Score, Self-Rating Depression Scale (SDS) score, and Self-Rating Anxiety Scale (SAS) score. Safety was also observed. And the efficacy was followed up 4 weeks after the end of treatment.
RESULTS:
Fifty-seven cases were enrolled into control group finally with 55 cases in the treatment group. After the treatment, all the patients in both of groups showed an improvement in IIEF-5 scores (P<0.01). Compared with the control group (19.09 ± 2.22), the IIEF-5 score in observation group (20.42 ± 2.39) increased significantly (P<0.01). After the treatment, the scores of PFI, TCM syndrome and SDS in both groups decreased (P<0.01, P<0.05, P<0.01). Compared with the control group ([3.77 ± 1.21], [9.91 ± 1.71] and [39.88 ± 2.63] points), the observation group ([2.92 ± 1.08], [4.78 ± 1.45], and [34.51 ± 2.09] points) showed a more significant decrease (P<0.01). There was no significant difference in total effective rate between the two groups (P>0.05). During follow-up, the IIEF-5 scores of both groups of patients were higher than those before (P<0.05, P<0.01), and the observation group score was higher than that in the control group ([17.15 ± 3.37] vs [13.63 ± 1.96], P<0.01). No adverse reaction and abnormality of indicators occurred in both of two groups.
CONCLUSION
Wenshen Chushi Decoction has a significant therapeutic effect on ED caused by renal deficiency and phlegm-dampness syndrome. It can not only improve the quality of erection, but also improve the physical and mental symptoms associated with ED, which makes therapeutic effect lasting longer.
Humans
;
Male
;
Drugs, Chinese Herbal/therapeutic use*
;
Erectile Dysfunction/etiology*
;
Middle Aged
;
Adult
;
Treatment Outcome
;
Medicine, Chinese Traditional
;
Ultrasonic Therapy
;
Phytotherapy
3.Chromatin landscape alteration uncovers multiple transcriptional circuits during memory CD8+ T-cell differentiation.
Qiao LIU ; Wei DONG ; Rong LIU ; Luming XU ; Ling RAN ; Ziying XIE ; Shun LEI ; Xingxing SU ; Zhengliang YUE ; Dan XIONG ; Lisha WANG ; Shuqiong WEN ; Yan ZHANG ; Jianjun HU ; Chenxi QIN ; Yongchang CHEN ; Bo ZHU ; Xiangyu CHEN ; Xia WU ; Lifan XU ; Qizhao HUANG ; Yingjiao CAO ; Lilin YE ; Zhonghui TANG
Protein & Cell 2025;16(7):575-601
Extensive epigenetic reprogramming involves in memory CD8+ T-cell differentiation. The elaborate epigenetic rewiring underlying the heterogeneous functional states of CD8+ T cells remains hidden. Here, we profile single-cell chromatin accessibility and map enhancer-promoter interactomes to characterize the differentiation trajectory of memory CD8+ T cells. We reveal that under distinct epigenetic regulations, the early activated CD8+ T cells divergently originated for short-lived effector and memory precursor effector cells. We also uncover a defined epigenetic rewiring leading to the conversion from effector memory to central memory cells during memory formation. Additionally, we illustrate chromatin regulatory mechanisms underlying long-lasting versus transient transcription regulation during memory differentiation. Finally, we confirm the essential roles of Sox4 and Nrf2 in developing memory precursor effector and effector memory cells, respectively, and validate cell state-specific enhancers in regulating Il7r using CRISPR-Cas9. Our data pave the way for understanding the mechanism underlying epigenetic memory formation in CD8+ T-cell differentiation.
CD8-Positive T-Lymphocytes/metabolism*
;
Cell Differentiation
;
Chromatin/immunology*
;
Animals
;
Mice
;
Immunologic Memory
;
Epigenesis, Genetic
;
SOXC Transcription Factors/immunology*
;
NF-E2-Related Factor 2/immunology*
;
Mice, Inbred C57BL
;
Gene Regulatory Networks
;
Enhancer Elements, Genetic
4.Guided by National Strategic Needs,Striving to Build a First-Class Forensic Medicine Discipline—The Construction Plan for Forensic Medicine at Southern Medical University
Dong-Fang QIAO ; Ping-Ming QIU ; Qi WANG ; Yun-Chun TAI ; Dong-Ri LI ; Jing-Tao XU ; Qi-Zhi LUO ; En-Ping HUANG ; Bo-Feng ZHU
Journal of Forensic Medicine 2025;41(1):15-19
The 2024 National Education Work Conference pointed out that at the current juncture of the critical period for achieving the goals and tasks of the 14th Five-Year Plan,the implementation of the Education Powerhouse Construction Plan Outline should be taken as the main line of work,and building first-class disciplines is an crucial task for a higher education powerhouse.In 2022,forensic medicine was officially listed as a first-level discipline under the medical category,presenting an un-precedented historical opportunity for the development of forensic medicine.The forensic medicine dis-cipline of Southern Medical University comprehensively improves the quality of talent cultivation and facilitates the construction of first-class disciplines as its main direction.It aims to initiate and imple-ment a high-level faculty team building plan featuring"combining recruitment and cultivation,inter-disciplinary integration";make vigorous efforts to establish a first-level doctoral program,refine advan-tageous second-level disciplines and research directions;and establish an innovative research platform from a high starting point with deep integration.The discipline adheres to moral cultivation and the Five Domains of Education simultaneous development,to build a high-quality talent joint training model.Guided by the construction of the national legal system and industry needs,the discipline will enhance social service capabilities.The forensic medicine construction in our university will continue to contribute to the rule of law in China and educational power.
5.Probucol combined with tirofiban for angina pectoris in patients with coronary heart disease after interventional surgery
Alatenqimuge ; Wangliang ZHU ; Bo YU ; Jianfei LI ; Xin QIAO ; Mingzhe SONG ; Dongye YUN
Journal of Interventional Radiology 2025;34(6):579-583
Objective To discuss the effect of probucol combined with tirofiban treatment on serum lipid peroxide levels and vascular endothelial function in patients with angina pectoris after interventional surgery of coronary heart disease(CHD).Methods A total of 120 patients with angina pectoris occurring after interventional surgery from January 2018 to December 2022 at the People's Hospital of Inner Mongolia Autonomous Region of China were enrolled in this study.Using random digital table method,the patients were divided into observation group(n=60)and control group(n=60).The patients of the control group received tirofiban,while the patients of the observation group received tirofiban plus probucol.All the preoperative and postoperative 7-day relevant indicators were recorded.The main observation indicator was the overall effective rate,and the secondary observation indicators included the frequency and duration of angina attacks,Seattle Angina Questionnaire(SAQ)score,cardiac function,myocardial injury markers,serum lipid peroxide levels,endothelial function and adverse reactions.Results The total effective rate in the observation group was 91.67%(55/60),which was higher than 78.33%(47/60)in the control group,the difference was statistically significant(P<0.05).After treatment,the improvement degree of angina pectoris,SAQ score,LVEF,serum superoxide dismutase(SOD),nitric oxide(NO)in the observation group were higher than those in the control group,while the LVESD,LVEDD,serum creatine kinase isozyme(CK-MB),lactate dehydrogenase(LDH),creatine kinase(CK),malondialdehyde(MDA),endothelin-1(ET-1)in the observation group were lower than those in the control group,the differences in the above indexes were statistically significant(all P<0.05).Conclusion For patients with angina pectoris occurring after interventional surgery of CHD,probucol combined with tirofiban has exact efficacy,which can promote the recovery of cardiac function,reduce myocardial injury,regulate serum lipid peroxide levels,and improve vascular endothelial function.
6.Application of intraoral scanning registration implant robot in dental implant surgery
Nenghao JIN ; Bo QIAO ; Liang ZHU ; Fanhao MENG ; Quanquan LIN ; Liangbo LI ; Lejun XING ; Rui ZHAO ; Haizhong ZHANG
West China Journal of Stomatology 2024;42(6):804-809
Objective This paper aims to investigate the application of intraoral scanning and cone beam computed tomography(CBCT)registration implant robot in dental implant surgery.Methods The data of 40 cases with dental de-fect of robot-assisted implantation from November 2023 to May 2024 were retrospectively analyzed.Before the opera-tion,the intraoral scan data and CBCT data of the posi-tioning markers were automatically fused with the initial CBCT images,and the registration error was calculated.The average registration error of positioning markers was determined during the operation,and the implantation ac-curacy was analyzed after the operation.Results The intraoral scan data and CBCT data of 40 patients with dental defect wearing positioning markers were successfully registered with the initial CBCT image,and the registration errors were(0.157±0.026)mm and(0.154±0.033)mm,respectively.Statistical analysis showed no statistical significance between them.The registration errors of the marker was(0.037 3±0.003 6)mm.A total of 55 implants were performed,and the total deviations of the implant point and the apical point were(0.78±0.41)and(0.89±0.28)mm,respectively.The transverse deviations of the implant point and the apical point were(0.44±0.36)and(0.58±0.25)mm,respectively.The depth deviations of the implant point and the apical point were(0.51±0.32)and(0.54±0.36)mm,respectively.The devia-tion of the implant angle was 1.24°±0.67°.Conclusion The fusion technology based on intraoral scanning and CBCT registration can meet the accuracy requirements of preoperative registration of oral implant robots.The technology in-creases the choice of registration methods before robot-assisted dental implant surgery and reduces the multiple radiation exposuresof the patient.
7.Clinical trial of montelukast sodium combined with terbutaline in the treatment of children with cough variant asthma
Jian-Fei CHEN ; Qiao-Bo ZHU ; Dong-Liang SHAO ; Xiao-Yi JI
The Chinese Journal of Clinical Pharmacology 2024;40(15):2155-2159
Objective To observe the application effect of montelukast sodium combined with terbutaline on cough variant asthma(CVA)in children and its influence on airway remodeling and peripheral blood inflammatory indicators.Methods The children with CVA were randomly classified into control group and treatment group.The control group was given aerosol inhalation of terbutaline(5 mg each time,twice a day),and on the basis of the control group,the treatment group was combined with oral administration of montelukast sodium granules(4 mg each time,once a day,taking before going to bed),and both groups were continuously treated for 3 months.The clinical efficacy,airway cross-section area(AO),airway lumen area(AI),airway wall thickness(T),airway wall area(WA),serum interleukin-5(IL-5),eosinophilic chemotactic factor(Eotaxin),macrophage inflammatory protein-1α(MIP-1α)and T lymphocyte subgroups CD4+,CD8+and CD4+/CD8+were compared between the two groups of children,and the medication safety was assessed.Results Fifty-three cases in control group and 53 cases in treatment group were included.After treatment,the total effective rates in treatment group and control group were 96.23%(51 cases/53 cases)and 83.02%(44 cases/53 cases),respectively(P<0.05).The AO values in treatment group and control group were(39.42±3.67)and(45.69±4.92)mm2;AI values were(22.36±2.85)and(27.06±3.18)mm2;T values were(1.12±0.28)and(1.44±0.33)mm;WA values were(53.82±4.17)and(60.13±4.66)mm2;serum IL-5 levels were(25.46±5.83)and(41.46±7.64)ng·L-1;Eotaxin levels were(181.24±30.05)and(238.21±39.42)ng·L-1;MIP-1a levels were(15.24±3.67)and(22.43±4.05)ng·L-1;CD4+levels were(37.18±4.06)%and(33.57±3.82)%;CD8+levels were(24.08±3.15)%and(27.31±3.07)%;and CD4+/CD8+levels were 1.54±0.33 and 1.24±0.28,respectively(all P<0.05).The total incidences of adverse drug reactions in treatment group and control group were 9.43%(5 cases/53 cases)and 3.77%(2 cases/53 cases),respectively(P>0.05).Conclusion Montelukast sodium combined with terbutaline has an exact efficacy in the treatment of CVA in children,and it can effectively reverse airway remodeling,reduce inflammation level and enhance immune function,and it has good safety.
8.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
9.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
10.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.

Result Analysis
Print
Save
E-mail