1.Application of annual progressive assessment mode in standardized training for residents in a medical laboratory base
Ying LUO ; Yuwei DI ; Yue MENG ; Qianyun DENG ; Hui LI ; Huiquan GAN ; Bing GU
Chinese Journal of Medical Education Research 2025;24(3):361-365
Objective:To explore the establishment, implementation, and application effect of the annual progressive assessment mode for standardized training of resident physicians in a medical laboratory base.Methods:Since 2020, the base has improved the annual progressive assessment system through assessment system establishment, question bank construction, routine assessment, rotation examination, and annual examination. This new assessment mode was adopted for the residency trainees enrolled in the base after 2020. The control group consisted of seven residency trainees enrolled before 2020, while the experimental group comprised 13 trainees enrolled in 2020 and later. The two groups were compared based on the rotation and annual examination scores of second- and third-year trainees, as well as their academic achievements. Additionally, teaching outcomes of the base before and after 2020 were analyzed. The t test, rank-sum test, and Fisher's exact test were performed using SPSS 27.00. Results:There were no significant differences in age, sex, and education level between the two groups. The experimental group showed significantly higher scores than the control group in theory assessment ( P<0.001 for second-year trainees and P=0.008 for third-year trainees) and skill assessment ( P<0.001 for second-year trainees and P=0.038 for third-year trainees) in rotation examination, as well as in theory assessment (both P<0.001) and skill assessment (both P<0.001) in annual examination. The improvement was particularly pronounced among second-year trainees. The trainees of the experimental group submitted 17 case reports in three years, and won awards at national conferences, provincial conferences, and institutional case speech competitions. In a national academic conference, the trainees won the second prize of "Excellent Case". Since 2020, we have been granted with our first teaching reform project and published our first teaching article. To date, we have obtained five teaching reform projects, published six teaching articles, and won multiple awards in provincial and institutional teaching competitions. Conclusions:The establishment of the annual progressive assessment mode is critical for training high-quality laboratory physicians, and puts forward higher requirements for residency training teachers.
2.Application study of pelvic floor muscle training combined with electromyographic biofeedback in urinary incontinence patients after radical prostatectomy
Chengfei GAO ; Jie GU ; Qianyun MA ; Ping REN ; Xianli MENG ; Xue LU ; Chunxue PENG ; Jie CAO
Chinese Journal of Nursing 2025;60(4):418-424
Objective To investigate the rehabilitative effects of pelvic floor muscle training(PFMT)combined with electromyography biofeedback(EMG-BF)in patients with post-prostatectomy incontinence(PPI),aims to provide refer-ence for clinical nursing practice.Methods 98 patients with PPI who were treated at the urinary incontinence nurse-led clinic of a tertiary hospital in Shanghai were included using the method of convenience sampling.Patients enrolled from June to September 2022 were assigned to a control group(n=49),receiving PFMT alone at home.Those enrolled from November 2022 to February 2023 were assigned to an experimental group(n=49),receiving PFMT at home combined with EMG-BF at the nurse-led clinic.Both groups received intervention for 3 months,preceded by guidance for PFMT provided by incontinence specialist nurses.The urine leakage in 24-hour pad test,the International Consultation on Incontinence Questionnaire-Short Form(ICIQ-SF),the Incontinence Quality of Life Questionnaires(I-QOL),and the Broome Pelvic Muscle Self-Efficacy Scale(BPMSES)were used to assess objective and subjective incontinence severity,quality of life,and self-efficacy of PFMT on the day of catheter removal and at 1,2,and 3 months post-intervention.Results A total of 46 patients were included in each group.The 24-hour urine leakage volume and I-QOL scores demonstrated significant between-group and over-time effects(P<0.05),with no interaction effect between groups and time(P>0.05)The ICIQ-SF and BPMSES scores exhibited interactive ef-fects between time and groups(P<0.05).At 2 and 3 months post-intervention,the intervention group showed signifi-cantly lower ICIQ-SF scores(P<0.001),and higher BPMSES scores(P<0.05),compared to those in the control group.Conclusion PFMT combined with EMG-BF can effectively alleviate the objective and subjective severity of PPI,enhance patients'self-efficacy in PFMT,and improve their postoperative quality of life.
3.Application study of pelvic floor muscle training combined with electromyographic biofeedback in urinary incontinence patients after radical prostatectomy
Chengfei GAO ; Jie GU ; Qianyun MA ; Ping REN ; Xianli MENG ; Xue LU ; Chunxue PENG ; Jie CAO
Chinese Journal of Nursing 2025;60(4):418-424
Objective To investigate the rehabilitative effects of pelvic floor muscle training(PFMT)combined with electromyography biofeedback(EMG-BF)in patients with post-prostatectomy incontinence(PPI),aims to provide refer-ence for clinical nursing practice.Methods 98 patients with PPI who were treated at the urinary incontinence nurse-led clinic of a tertiary hospital in Shanghai were included using the method of convenience sampling.Patients enrolled from June to September 2022 were assigned to a control group(n=49),receiving PFMT alone at home.Those enrolled from November 2022 to February 2023 were assigned to an experimental group(n=49),receiving PFMT at home combined with EMG-BF at the nurse-led clinic.Both groups received intervention for 3 months,preceded by guidance for PFMT provided by incontinence specialist nurses.The urine leakage in 24-hour pad test,the International Consultation on Incontinence Questionnaire-Short Form(ICIQ-SF),the Incontinence Quality of Life Questionnaires(I-QOL),and the Broome Pelvic Muscle Self-Efficacy Scale(BPMSES)were used to assess objective and subjective incontinence severity,quality of life,and self-efficacy of PFMT on the day of catheter removal and at 1,2,and 3 months post-intervention.Results A total of 46 patients were included in each group.The 24-hour urine leakage volume and I-QOL scores demonstrated significant between-group and over-time effects(P<0.05),with no interaction effect between groups and time(P>0.05)The ICIQ-SF and BPMSES scores exhibited interactive ef-fects between time and groups(P<0.05).At 2 and 3 months post-intervention,the intervention group showed signifi-cantly lower ICIQ-SF scores(P<0.001),and higher BPMSES scores(P<0.05),compared to those in the control group.Conclusion PFMT combined with EMG-BF can effectively alleviate the objective and subjective severity of PPI,enhance patients'self-efficacy in PFMT,and improve their postoperative quality of life.
4.Application of annual progressive assessment mode in standardized training for residents in a medical laboratory base
Ying LUO ; Yuwei DI ; Yue MENG ; Qianyun DENG ; Hui LI ; Huiquan GAN ; Bing GU
Chinese Journal of Medical Education Research 2025;24(3):361-365
Objective:To explore the establishment, implementation, and application effect of the annual progressive assessment mode for standardized training of resident physicians in a medical laboratory base.Methods:Since 2020, the base has improved the annual progressive assessment system through assessment system establishment, question bank construction, routine assessment, rotation examination, and annual examination. This new assessment mode was adopted for the residency trainees enrolled in the base after 2020. The control group consisted of seven residency trainees enrolled before 2020, while the experimental group comprised 13 trainees enrolled in 2020 and later. The two groups were compared based on the rotation and annual examination scores of second- and third-year trainees, as well as their academic achievements. Additionally, teaching outcomes of the base before and after 2020 were analyzed. The t test, rank-sum test, and Fisher's exact test were performed using SPSS 27.00. Results:There were no significant differences in age, sex, and education level between the two groups. The experimental group showed significantly higher scores than the control group in theory assessment ( P<0.001 for second-year trainees and P=0.008 for third-year trainees) and skill assessment ( P<0.001 for second-year trainees and P=0.038 for third-year trainees) in rotation examination, as well as in theory assessment (both P<0.001) and skill assessment (both P<0.001) in annual examination. The improvement was particularly pronounced among second-year trainees. The trainees of the experimental group submitted 17 case reports in three years, and won awards at national conferences, provincial conferences, and institutional case speech competitions. In a national academic conference, the trainees won the second prize of "Excellent Case". Since 2020, we have been granted with our first teaching reform project and published our first teaching article. To date, we have obtained five teaching reform projects, published six teaching articles, and won multiple awards in provincial and institutional teaching competitions. Conclusions:The establishment of the annual progressive assessment mode is critical for training high-quality laboratory physicians, and puts forward higher requirements for residency training teachers.
5.Innovative design and experimental study of electromagnetic ejection endoscopic suture device
Dongming YIN ; Yujia LI ; Zhongxin HU ; Zhaoning GENG ; Qianyun GU ; Chengli SONG
International Journal of Biomedical Engineering 2024;47(1):10-16
Objective:To design a novel electromagnetic ejection device for endoscopic suturing to achieve continuous deployment of suture nails.Methods:An electromagnetic ejection device and its accompanying suture nail structure were designed and a prototype was fabricated based on electromagnetic ejection principles. A finite element model of the electromagnetic ejection device was constructed to study the effects of armature-coil center distance and different driving voltages on suture nail ejection speed. An experimental platform for testing electromagnetic ejection velocity was constructed, and a high-speed camera was used to detect the ejection velocity. A platform for the suture embedding experiment was built to measure the effects of different voltages on the inserting speed of suture into the gastric wall tissue. A platform for a suture extraction force experiment was built to evaluate the extraction force of sutures embedded in tissues under different driving voltages.Results:A suture nail structure and electromagnetic ejection device were designed, and a prototype was fabricated. The ejection velocity increased and then decreased with the increase of the armature-coil center distance, and the maximum ejection velocity was 15.81 m/s at the center distance of 18 mm. At this distance, the voltage was linearly related to the ejection velocity, and the experimental values of the staple basically coincided with the simulated values. When the driving voltage was in the range of 150 to 180 V, the suture nails could successfully insert in the tissues, and the 180 V voltage group had a greater insertion depth. The extraction force of the suture nails at 120, 150, 180, and 210 V voltages were (0.49 ± 0.19), (1.14 ± 0.19), (1.23 ± 0.15), and (1.85 ± 0.31) N, respectively.Conclusions:A novel electromagnetic ejection device for endoscopic suturing is proposed that is capable of continuous firing of suture nails. This device provides a new long-distance driving method for intelligent, minimally invasive surgical instruments.
6.A gallstones classification method and verification based on deep learning
Qianyun GU ; Chengli SONG ; Jiawen GUO ; Dongming YIN ; Shiju YAN ; Bo WANG ; Zhaoyan JIANG ; Hai HU
International Journal of Biomedical Engineering 2024;47(4):312-317
Objective:To establish and validate a gallstones classification method based on deep learning.Methods:A total of 618 gallstones samples were collected from East Hospital Affiliated to Tongji University, and 1 023 high-definition cross-sectional gallstones profile images were captured to construct a cross-sectional gallstones profile image dataset. Based on the traditional eight-category gallstones classification method, a lightweight network model, MobileNet V3, was trained using deep learning and transfer learning methods. The classification performance of MobileNet was evaluated using a confusion matrix with metrics such as accuracy rate, precision rate, F1 score, and recall rate. The MobileNet V3 was improved and further validated using accuracy and loss values.Results:The accuracy rate (94.17%), precision rate (94.03%), F1 score (92.96%) and recall rate (92.99%) of the improved MobileNet V3 model were better than other networks. The improved MobileNet V3 model achieved the highest accuracy rate (94.17%) in gallstones profile classification and was validated by the test set. The confusion matrix showed a weighted average of accuracy rate (92.0%), precision rate (92.6%), and F1 score (92.2%) for each category of gallstones.Conclusions:Based on deep learning, a high-accuracy gallstones classification method is proposed, which provides a new idea for the intelligent identification of gallstones.
7.Establishment of Gallbladder Volume Calculation Method and Analysis of Motor Function Based on CT Images
Jiawen GUO ; Chengli SONG ; Qianyun GU ; Bo WANG ; Zhaoyan JIANG ; Hai HU
Journal of Medical Biomechanics 2024;39(2):332-338
Objective To evaluate the accuracy of three-dimensional(3D)reconstruction of the gallbladder volume based on computed tomography(CT)images and study the biomechanical changes in gallbladder motility to explore the relationship between gallbladder dynamics and gallstone formation.Methods A method for calculating gallbladder volume based on CT 3D reconstruction of The gallbladder model was proposed and compared with the ellipsoid method.A finite element model of the gallbladder was constructed for fluid dynamics analysis to simulate changes in gallbladder motor function under different angles of convergence between the cystic and common bile ducts and in the presence of gallstones.Results The mean errors of the specific gallbladder model volume and ellipsoid volume of the 50 patients were 7.26%and 25.35%,respectively.During the refilling period,the maximum pressure,deformation,and flow velocity of the pear-shaped gallbladder were significantly higher than those of the gourd-shaped gallbladder.The angle between the gallbladder and common bile duct had little effect on the bile flow pattern,and the maximum bile flow rate was reached at an angle of 120°.The bile flow velocity of the gallbladder with calculus was lower than that of the gallbladder without calculus,and there was a vortex near the calculus.Conclusions Calculating gallbladder volume based on CT 3D reconstruction is more accurate than the ellipsoid method.Compared with a pear-shaped gallbladder,a gourd-shaped gallbladder has lower gallbladder wall contraction,bile flow rate,and poor motor function.The bile flow rate in the gallbladder is slow,which is more likely to lead to the enlargement of gallstones or the formation of new gallstones.
8.Risk factors and sonographic findings associated with the type of placenta accreta spectrum disorders
Huijing ZHANG ; Ruochong DOU ; Li LIN ; Qianyun WANG ; Beier HUANG ; Xianlan ZHAO ; Dunjin CHEN ; Yiling DING ; Hongjuan DING ; Shihong CUI ; Weishe ZHANG ; Hong XIN ; Weirong GU ; Yali HU ; Guifeng DING ; Hongbo QI ; Ling FAN ; Yuyan MA ; Junli LU ; Yue YANG ; Li LIN ; Xiucui LUO ; Xiaohong ZHANG ; Shangrong FAN ; Huixia YANG
Chinese Journal of Obstetrics and Gynecology 2019;54(1):27-32
Objective To evaluate the risk factors and sonographic findings of pregnancies complicated by placenta increta or placenta percreta. Methods Totally, 2219 cases were retrospectively analyzed from 20 tertiary hospitals in China from January 2011 to December 2015. The data were collected based on the original case records. All cases were divided into two groups, the placenta increta (PI) group (79.1%, 1755/2219) and the placenta percreta (PP) group (20.9%, 464/2219), according to the degree of placental implantation. The risk factors and sonographic findings of placenta increta or percreta were analyzed by uni-factor and logistic regression statistic methods. Results The risk factors associated with the degree of placental implantation were age, gravida, previous abortion or miscarriage, previous cesarean sections, and placenta previa (all P<0.05), especially, previous cesarean sections (χ2=157.961) and placenta previa (χ2=91.759). Sonographic findings could be used to predict the degree of placental invasion especially the boundaries between placenta and uterine serosa, the boundary between placenta and myometrium, the disruption of the placental-uterine wall interface and loss of the normal retroplacental hypoechoic zone(all P<0.01). Conclusions Previous cesarean sections and placenta previa are the main independent risk factors associated with the degree of placenta implantation. Ultrasound could be used to make a prenatal suggestive diagnosis of placenta accreta spectrum disorders.
9.Fluorescence Assay for Phospholipase C Activity Using Liposome Probes
Qiaorong GU ; Junjie AI ; Qianyun ZHANG ; Yanan DONG ; Qiang GAO
Chinese Journal of Analytical Chemistry 2017;45(9):1278-1283
A simple assay for detection of phospholipase C (PLC) activity was developed based on a fluorescence liposome probe using the Liss Rhod PE-loaded phospholipid liposomes.The liposome probe was prepared by the coassembly of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) and fluorescent lipid (Liss Rhod PE).The probe showed very low background fluorescence due to fluorescence self-quenching effect of Liss Rhod PE.As the PLC enzyme selectively digested lipid, the Rhod fluorescence was recovered from its quenched state, leading to the sensitive detection of PLC.This assay provided a limit of detection (at a signal-to-noise ratio of 3) of 2 U/L for PLC.In the presence of PLC inhibitor, the fluorescent response of the sensor for PLC decreased, indicating that the assay could also be used for screening PLC inhibitors.

Result Analysis
Print
Save
E-mail