1.Short-term results of transcatheter aortic valve replacement using Venus A-Plus valve delivery system in patients with severe aortic stenosis: A retrospective cohort study
Hang ZHANG ; Huajun WANG ; Fengwu SHI ; Su LIU ; Qianli MA ; Jinghui AN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(03):438-443
Objective To evaluate the short-term efficacy of transcatheter aortic valve replacement (TAVR) using Venus A-Plus valve delivery system in patients with severe aortic stenosis. Methods The clinical data of patients undergoing TAVR in our hospital from August 2018 to March 2022 were collected and they were divided into a Venus A-Plus and a Venus A group according to the type of valve delivery system used. The perioperative data of the two groups were compared. Results A total of 121 patients were included, including 70 patients in the Venus A-Plus group [45 males and 25 females with a mean age of (67.81±6.62) years], and 51 patients in the Venus A group [33 males and 18 females with a mean age of (68.25±7.01) years]. All patients underwent TAVR, and the postoperative hemodynamic features (left ventricular ejection fraction, mean cross-valve pressure difference, peak flow rate) were significantly improved (P<0.05). There was no statistical difference in surgical success rate, all-cause mortality, conversion to thorax opening, valve-in-valve placement, moderate or above perivalvular regurgitation, new left bundle branch block or new right bundle branch block between the two groups (P>0.05). Conclusion TAVR with Venus A-Plus valve delivery system in patients with severe aortic stenosis shows comparable efficacy to the first-generation Venus A system and is satisfactory, safe and reliable.
2.Identification of potential biomarkers of proliferative diabetic retinopathy based on proteomics and transcriptomics data
Yeanqi JIN ; Junbin LIU ; Xiang FANG ; Guanrong WU ; Haoxian ZHU ; Xinyu CHEN ; Mengya LIU ; Shuoxin LIAO ; Fangfang LI ; Xueli ZHANG ; Qianli MENG
Recent Advances in Ophthalmology 2025;45(8):622-628
Objective To identify potential biomarkers for proliferative diabetic retinopathy(PDR)using proteomics and transcriptomics data.Methods In this study,the proteomics dataset(PXD046630)and two transcriptomics datasets(GSE60436 and GSE102485)were derived from the aqueous humor samples and fibrovascular membranes of PDR patients,respectively.Differentially expressed genes(DEGs)were identified via R software,specifically the limma and edgeR pack-ages.The shared DEGs between PXD046630 and GSE60436 were analyzed via protein-protein interaction(PPI),Gene On-tology(GO)enrichment,and Kyoto Encyclopedia of Genes and Genomes(KEGG)pathway enrichment analyses.The key DEGs were validated in GSE102485 via receiver operating characteristic(ROC)curve analysis.A quantitative polymerase chain reaction(qPCR)assay was used to confirm the mRNA of these candidate biomarkers in human retinal microvascular endothelial cells(HRMECs)cultured in high glucose and low oxygen conditions.Results A total of 59 shared DEGs and 26 hub genes were identified from the PXD046630 and GSE60436 datasets.KEGG analysis revealed that six pathways,inclu-ding extracellular matrix-receptor interaction,proteoglycans in cancer,and complement and coagulation cascades,were enriched in 12 key DEGs.Fibronectin 1(FN1),tissue inhibitor of metalloproteinase 3(TIMP3),complement factor H(CFH),decorin(DCN),and lipoprotein receptor-related protein-2(LRP2)were identified as potential biomarkers on the basis of their AUC values being greater than 0.900(CI≥95%).The mRNA expression levels of FN1,CFH,and LRP2 were significantly increased in HRMECs cultured in high glucose and low oxygen conditions.Conclusion FN1,CFH,and LRP2 are potential biomarkers for PDR,and further studies are needed to explore their roles and therapeutic potential in PDR.
3.New-onset conduction block after transcatheter aortic valve replacement: A retrospective analysis in a single center
Hang ZHANG ; Huajun WANG ; Fengwu SHI ; Su LIU ; Qianli MA ; Jinghui AN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(03):372-376
Objective To investigate the new-onset conduction block after transcatheter aortic valve replacement (TAVR) and summarize the relevant experience. Methods The perioperative data of TAVR patients in the Second Hospital of Hebei Medical University from January 2016 to February 2023 were collected, and the new-onset incidence of conduction block after TAVR was analyzed retrospectively. Results Finally 352 patients were included, including 225 males and 127 females, with an average age of (67.2±5.1) years, among whom 256 patients were treated with Venus-A valves, 69 patients with Vita-Flow valves, and 27 patients with J-Valve valves. There were 38 (10.8%) patients of new-onset postoperative block. There were 6 (1.7%) patients of new-onset postoperative grade Ⅲ atrioventricular block, including 5 (2.0%) patients of Venus-A and 1 (1.4%) patient of Vita-Flow. Conduction function was restored in 2 patients within 14 days after surgery, and failed to be restored in 4 patients, who then received permanent pacemaker implantation in the Department of Cardiology. There were 27 (7.7%) patients of new left bundle branch block after surgery, including 22 (8.6%) patients of Venus-A, 4 (5.8%) patients of Vita-Flow and 1 (3.7%) patient of J-Valve; and conduction function was restored within 7 days after surgery in 23 patients, and 5 (1.4%) patients developed new right bundle branch blocks after surgery including 4 (1.5%) patients of Venus-A and 1 (1.4%) patient of Vita-Flow. Conclusion New-onset conduction block is a common complication after TAVR, and the new-onset rate of left bundle branch block is the highest, followed by the grade Ⅲ atrioventricular block. Mastering reasonable methods and applying appropriate strategies can effectively reduce the new-onset rate of postoperative conduction block and improve the overall success rate of TAVR surgery.
4.Short-term results of emergency conversion to surgery during transcatheter aortic valve replacement: A retrospective cohort study
Qilin LU ; Jieqiong ZHANG ; Jinghui AN ; Su LIU ; Qianli MA ; Fengwu SHI
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(08):1146-1150
Objective To analyze the short-term clinical outcomes of emergency conversion to surgery during transcatheter aortic valve replacement (TAVR). Methods Clinical data of patients who underwent emergency surgical conversion from TAVR in the Department of Cardiovascular Surgery, the Second Hospital of Hebei Medical University, from 2018 to 2023 were collected. Postoperative follow-up results at 1 month were recorded. Results A total of 253 patients underwent TAVR, of whom 11 (4.3%) required emergency conversion to surgery. Among these 11 patients, 7 were male and 4 were female, with a mean age of (69.55±5.01) years. The primary cause for emergency surgical conversion was valve stent displacement (63.6%), followed by left ventricular perforation/rupture (18.2%) and significant perivalvular regurgitation persisting after a second valve implantation (18.2%). One (9.1%) patient died intraoperatively. Among the 10 surviving patients, postoperative complications included pulmonary infection in 8 patients, severe pneumonia in 7, pleural effusion in 3, liver dysfunction in 8, renal dysfunction in 3, upper gastrointestinal bleeding in 5, cerebrovascular complications in 1, atrial fibrillation in 1, ventricular premature contractions in 1, atrioventricular block in 1, and complete left bundle branch block in 3. At 1-month postoperative follow-up, one additional patient died, yielding a 30-day mortality rate of 18.2% after TAVR emergency surgical conversion. The quality of life improved significantly compared to preoperative status in 9 (81.8%) patients, and no patients were readmitted for cardiovascular diseases. Conclusion The incidence of emergency conversion to surgery during TAVR is low, but the rates of surgical complications and 30-day postoperative mortality are high. Nevertheless, when severe complications occur during TAVR, emergency conversion to surgery can still yield satisfactory short-term clinical outcomes for a majority of these patients.
5.Hematopoietic Engineering:The Current Status and Prospects of In Vitro Erythrocyte Production Technology
Qianli ZHUO ; Zhaojun ZHANG ; Xiangdong FANG
Medical Journal of Peking Union Medical College Hospital 2025;16(5):1179-1184
In vitro erythrocyte manufacturing technology offers a novel solution for transfusion therapy,en-suring sustainable blood supply,reducing dependence on donors,and minimizing the risk of infectious disease transmission.This review summarizes recent advancements in in vitro erythrocyte production,including techniques for generating red blood cells(RBC)from various cell sources,with a focus on the cultivation and development of immortalized erythroid cell lines.The importance of enhancing enucleation efficiency and ensuring the safety of immortalized erythroid cells is emphasized.Additionally,the potential and challenges in clinical translation are discussed,aiming to provide new insights for future sustainable RBC supply and therapeutic applications.
6.Application of 3D printing technology in transcatheter aortic valve replacement for bicuspid aortic stenosis
Hang ZHANG ; Huajun WANG ; Fengwu SHI ; Su LIU ; Qianli MA ; Jinghui AN
Journal of China Medical University 2025;54(10):942-945,957
Objective To explore the value of 3D printing technology in transcatheter aortic valve replacement(TAVR)for bicuspid aortic stenosis.Methods We retrospectively analyzed the clinical data of patients who underwent TAVR for bicuspid aortic stenosis at the Department of Cardiac Surgery of the Second Hospital of Hebei Medical University between January 2020 and January 2023.Seven-ty patients were divided into 3D printing and non-3D printing groups of 35 each,based on whether or not 3D printing technology was applied,and the perioperative clinical data of the two groups were compared.Results The patients' postoperative symptoms signifi-cantly improved compared with those before the operation,and the left ventricular ejection fraction increased to varying degrees.Compared with the non-3D printing group,the operation time,X-ray irradiation time.and transvalvular time in the 3D printing group were signifi-cantly shortened,and the probabilities of the occurrence of postoperative"flap-to-flap"implantation and conduction block were signifi-cantly reduced,with statistically significant differences(P<0.05).There was no statistically significant difference(P>0.05)in the inci-dence of moderate and above perivalvular leakage,valve displacement,or conversion to thoracotomy between the two groups after surgery.Conclusion 3D printing technology can effectively guide the TAVR treatment of bicuspid aortic stenosis.While significantly shortening the operation time,it can effectively increase the success rate of TAVR and reduce the risk of adverse events,providing a new approach for the transcatheter treatment of bicuspid aortic stenosis.
7.Application of 3D printing technology in transcatheter aortic valve replacement for bicuspid aortic stenosis
Hang ZHANG ; Huajun WANG ; Fengwu SHI ; Su LIU ; Qianli MA ; Jinghui AN
Journal of China Medical University 2025;54(10):942-945,957
Objective To explore the value of 3D printing technology in transcatheter aortic valve replacement(TAVR)for bicuspid aortic stenosis.Methods We retrospectively analyzed the clinical data of patients who underwent TAVR for bicuspid aortic stenosis at the Department of Cardiac Surgery of the Second Hospital of Hebei Medical University between January 2020 and January 2023.Seven-ty patients were divided into 3D printing and non-3D printing groups of 35 each,based on whether or not 3D printing technology was applied,and the perioperative clinical data of the two groups were compared.Results The patients' postoperative symptoms signifi-cantly improved compared with those before the operation,and the left ventricular ejection fraction increased to varying degrees.Compared with the non-3D printing group,the operation time,X-ray irradiation time.and transvalvular time in the 3D printing group were signifi-cantly shortened,and the probabilities of the occurrence of postoperative"flap-to-flap"implantation and conduction block were signifi-cantly reduced,with statistically significant differences(P<0.05).There was no statistically significant difference(P>0.05)in the inci-dence of moderate and above perivalvular leakage,valve displacement,or conversion to thoracotomy between the two groups after surgery.Conclusion 3D printing technology can effectively guide the TAVR treatment of bicuspid aortic stenosis.While significantly shortening the operation time,it can effectively increase the success rate of TAVR and reduce the risk of adverse events,providing a new approach for the transcatheter treatment of bicuspid aortic stenosis.
8.Identification of potential biomarkers of proliferative diabetic retinopathy based on proteomics and transcriptomics data
Yeanqi JIN ; Junbin LIU ; Xiang FANG ; Guanrong WU ; Haoxian ZHU ; Xinyu CHEN ; Mengya LIU ; Shuoxin LIAO ; Fangfang LI ; Xueli ZHANG ; Qianli MENG
Recent Advances in Ophthalmology 2025;45(8):622-628
Objective To identify potential biomarkers for proliferative diabetic retinopathy(PDR)using proteomics and transcriptomics data.Methods In this study,the proteomics dataset(PXD046630)and two transcriptomics datasets(GSE60436 and GSE102485)were derived from the aqueous humor samples and fibrovascular membranes of PDR patients,respectively.Differentially expressed genes(DEGs)were identified via R software,specifically the limma and edgeR pack-ages.The shared DEGs between PXD046630 and GSE60436 were analyzed via protein-protein interaction(PPI),Gene On-tology(GO)enrichment,and Kyoto Encyclopedia of Genes and Genomes(KEGG)pathway enrichment analyses.The key DEGs were validated in GSE102485 via receiver operating characteristic(ROC)curve analysis.A quantitative polymerase chain reaction(qPCR)assay was used to confirm the mRNA of these candidate biomarkers in human retinal microvascular endothelial cells(HRMECs)cultured in high glucose and low oxygen conditions.Results A total of 59 shared DEGs and 26 hub genes were identified from the PXD046630 and GSE60436 datasets.KEGG analysis revealed that six pathways,inclu-ding extracellular matrix-receptor interaction,proteoglycans in cancer,and complement and coagulation cascades,were enriched in 12 key DEGs.Fibronectin 1(FN1),tissue inhibitor of metalloproteinase 3(TIMP3),complement factor H(CFH),decorin(DCN),and lipoprotein receptor-related protein-2(LRP2)were identified as potential biomarkers on the basis of their AUC values being greater than 0.900(CI≥95%).The mRNA expression levels of FN1,CFH,and LRP2 were significantly increased in HRMECs cultured in high glucose and low oxygen conditions.Conclusion FN1,CFH,and LRP2 are potential biomarkers for PDR,and further studies are needed to explore their roles and therapeutic potential in PDR.
9.Short-term clinical efficacy of one-stop TAVR+PCI in the treatment of patients with aortic valve disease and coronary heart disease
Huajun WANG ; Hang ZHANG ; Tong SU ; Hongjuan LIAO ; Ziying CHEN ; Fengwu SHI ; Qianli MA ; Su LIU ; Jinghui AN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(06):848-852
Objective To analyze the short-term clinical efficacy and prognosis of one-stop transcatheter aortic valve replacement (TAVR)+percutaneous coronary intervention (PCI) in the treatment of aortic valve disease with coronary heart disease. Methods The clinical data of patients with aortic valve disease complicated with coronary heart disease who underwent one-stop TAVR+PCI treatment at the Department of Cardiovascular Surgery, the Second Hospital of Hebei Medical University from January 2018 to June 2023 were retrospective analyzed. The preoperative and postoperative clinical data were compared, and 1-month follow-up results were recorded. Results A total of 37 patients were enrolled, including 22 males and 15 females, with an average age of 69.14±6.47 years. Thirty-six patients recovered and were discharged after the surgery, and 1 (2.7%) patient died during the surgery. Self-expanding TAVR valves were implanted through the femoral artery in all patients. One coronary artery was opened by PCI in 35 (94.6%) patients, and two coronary arteries were opened by PCI in 2 (5.4%) patients. All PCI opened arteries had a stenosis>70%. During the postoperative hospitalization, the complications included pulmonary infection in 11 (30.6%) patients, severe pneumonia in 10 (27.8%) patients, liver function injury in 14 (38.9%) patients, renal function injury in 5 (13.9%) patients, cerebral infarction in 1 (2.8%) patient, atrial fibrillation in 1 (2.8%) patient, ventricular premature beats in 2 (5.6%) patients, atrioventricular block in 2 (5.6%) patients, and complete left bundle branch block in 5 (13.9%) patients. The median postoperative ventilation assistance time was 12.0 (0.0, 17.0) h, the ICU monitoring time was 1.0 (0.0, 2.0) d, and the postoperative hospitalization time was 5.0 (4.0, 7.0) d. There was a significant improvement in the New York Heart Association cardiac function grading after surgery (P<0.001). After surgery, there were 21 (58.3%) patients had minor perivalve leakage, 6 (16.7%) patients had minor to moderate perivalve leakage, and no moderate or above degree of perivalve leakage. After one month of postoperative follow-up, 36 patients showed significant improvement in heart function. There were no patients with recurrent acute coronary syndrome, re-PCI, or cardiovascular system disease related re-hospitalization. Conclusion The one-stop TAVR+PCI treatment for patients with aortic valve disease and coronary heart disease can obtain satisfactory short-term clinical efficacy, which is worth further trying and studying.
10.Hematopoietic Engineering: The Current Status and Prospects of In Vitro Erythrocyte Production Technology
Qianli ZHUO ; Zhaojun ZHANG ; Xiangdong FANG
Medical Journal of Peking Union Medical College Hospital 2024;16(5):1179-1184

Result Analysis
Print
Save
E-mail