1.Research and Outlook on The Application of Radar-based Non-contact Health Monitoring Technology
Jia-Bin ZHONG ; Qing ZHANG ; Shuai-Wei QIAN
Progress in Biochemistry and Biophysics 2026;53(4):982-999
Radar-based non-contact health monitoring technology (RBNHMT) has emerged as a transformative paradigm in continuous health sensing, enabling non-invasive and continuous monitoring of physiological parameters and behavioral patterns by transmitting electromagnetic waves, analyzing the reflected signals, and detecting subtle bodily movements—ranging from millimeter-scale chest wall displacements due to respiration to micro-scale vibrations associated with cardiac activity—ultimately transforming them into quantifiable health data. Distinguished by its non-contact operation, inherent privacy preservation, and adaptability to diverse scenarios, RBNHMT exhibits stronger resistance to environmental interference than conventional contact-based monitoring, and has solidified its position as a prominent and dynamic research focus in the field of non-contact health monitoring. Currently, significant and multifaceted progress has been made across several key areas. In human activity recognition (HAR), systems leveraging micro-Doppler signatures or point cloud sequences achieve high-precision detection of gait, gestures, and fall events, with state-of-the-art deep learning-based models achieving accuracy rates exceeding 99% in controlled experimental settings. For vital sign and sleep monitoring, it not only tracks respiratory and heart rates continuously but also extracts clinically relevant metrics such as heart rate variability (HRV) for autonomic nervous system assessment and estimates blood pressure through indirect methods like pulse transit time analysis, while maintaining robustness in dynamic settings through advanced motion compensation algorithms. In sleep monitoring, it further enables sleep posture classification and apnea event detection. In emotion and stress recognition, it provides a non-intrusive approach for psychological assessment by analyzing autonomic-response physiological signal patterns or behavioral features. Furthermore, its applications in auxiliary medical diagnosis have expanded to promising interdisciplinary areas such as non-contact heart sound auscultation, radar-based screening for obstructive sleep apnea (OSA), and emerging research into breast cancer detection using microwave and millimeter-wave imaging techniques. However, several challenges impede its practical deployment. Signal quality is significantly compromised by multipath interference in complex indoor environments and clutter from static objects, and by motion artifacts in dynamic scenarios where gross body movements obscure the subtle physiological signals. Algorithmically, separating signals from multiple targets in close proximity and calibrating for substantial individual physiological differences, such as body habitus, baseline vital signs, remain difficult and limit generalizability. Hardware design also faces the challenge of balancing power consumption, cost, integration, and performance, often requiring trade-offs that constrain miniaturization, battery life, or measurement sensitivity. Future advancement, therefore, requires collaborative and targeted innovation across multiple dimensions. Algorithmically, developing adaptive signal processing models based on emerging paradigms such as few-shot learning (for user-specific calibration with minimal data) and reinforcement learning (for dynamic noise suppression) is essential. At the hardware level, highly integrated radar SoCs with embedded processing capabilities and advanced packaging technologies are crucial for achieving the dual goals of device miniaturization and cost reduction without sacrificing performance. At the system level, fusing radar data with complementary modalities such as infrared and acoustic sensing can create a synergistic, multi-modal framework that significantly enhances perceptual robustness and reliability in complex, real-world environments. This review provides a comprehensive synthesis that systematically summarizes the relevant theoretical foundations and application progress, and offers an in-depth analysis of the current technical bottlenecks. It aims to provide a clear development path and a foundational academic reference for the in-depth integration and practical application of RBNHMT in critical scenarios including rehabilitation engineering, smart elderly care, in-vehicle health monitoring, and beyond, thereby offering innovative technical support for the vision of universal, proactive, and personalized health management.
2.A Sensitive Lateral Flow Immunoassay for Detection of Interleukin-6 Using Carbon Dots-Mesoporous Silica Nanocomposite Fluorescent Probes
Yue-Qian YANG ; Peng-Yue WANG ; Jia-Qi REN ; Xiao PAN ; Feng-Hua TAN ; Yu-Jie MA ; Cong-Ying WEN ; Jing-Bin ZENG
Chinese Journal of Analytical Chemistry 2025;53(9):1467-1475
In this study,a sensitive lateral flow immunoassay(LFIA)platform based on carbon dots-mesoporous silica nanocomposite(CD-MSNs)fluorescent probes was constructed for high-performance detection of inflammatory marker interleukin-6(IL-6).Green fluorescent carbon dots(CDs)were prepared by hydrothermal method with 3,9-perylenic acid and 3-aminopropyltriethoxysilane(APTES)as raw materials,and highly fluorescent CD-MSNs composites were then constructed by encapsulating the prepared CDs in mesoporous silica nanoparticles(MSNs).Fluorescent probes were prepared by covalent coupling of CD-MSNs with IL-6 antibody.Fluorescent immunochromatographic test strips were constructed by spraying IL-6 capture antibody and goat anti-mouse IgG on nitrocellulose membrane as detection line(T-line)and quality control line(C-line),respectively.The fluorescence immunoassay analyzer was used to quantitatively detect the fluorescence intensity of T-line,and the experimental results showed that the LFIA platform based on this probe had a good linear relationship in IL-6 concentration range of 102-106 pg/mL,and the detection limit was 64 pg/mL,which was two orders of magnitude more sensitive than that of the traditional colloidal gold test strips.This method effectively solved the issue of insufficient sensitivity of traditional LFIA technique,and provided a rapid and highly sensitive detection method for early diagnosis of inflammatory diseases.
3.Associations of Exposure to Typical Environmental Organic Pollutants with Cardiopulmonary Health and the Mediating Role of Oxidative Stress: A Randomized Crossover Study.
Ning GAO ; Bin WANG ; Ran ZHAO ; Han ZHANG ; Xiao Qian JIA ; Tian Xiang WU ; Meng Yuan REN ; Lu ZHAO ; Jia Zhang SHI ; Jing HUANG ; Shao Wei WU ; Guo Feng SHEN ; Bo PAN ; Ming Liang FANG
Biomedical and Environmental Sciences 2025;38(11):1388-1403
OBJECTIVE:
The study aim was to investigate the effects of exposure to multiple environmental organic pollutants on cardiopulmonary health with a focus on the potential mediating role of oxidative stress.
METHODS:
A repeated-measures randomized crossover study involving healthy college students in Beijing was conducted. Biological samples, including morning urine and venous blood, were collected to measure concentrations of 29 typical organic pollutants, including hydroxy polycyclic aromatic hydrocarbons (OH-PAHs), bisphenol A and its substitutes, phthalates and their metabolites, parabens, and five biomarkers of oxidative stress. Health assessments included blood pressure measurements and lung function indicators.
RESULTS:
Urinary concentrations of 2-hydroxyphenanthrene (2-OH-PHE) ( β = 4.35% [95% confidence interval ( CI): 0.85%, 7.97%]), 3-hydroxyphenanthrene ( β = 3.44% [95% CI: 0.19%, 6.79%]), and 4-hydroxyphenanthrene (4-OH-PHE) ( β = 5.78% [95% CI: 1.27%, 10.5%]) were significantly and positively associated with systolic blood pressure. Exposures to 1-hydroxypyrene (1-OH-PYR) ( β = 3.05% [95% CI: -4.66%, -1.41%]), 2-OH-PHE ( β = 2.68% [95% CI: -4%, -1.34%]), and 4-OH-PHE ( β = 3% [95% CI: -4.68%, -1.29%]) were negatively associated with the ratio of forced expiratory volume in the first second to forced vital capacity. These findings highlight the adverse effects of exposure to multiple pollutants on cardiopulmonary health. Biomarkers of oxidative stress, including 8-hydroxy-2'-deoxyguanosine and extracellular superoxide dismutase, mediated the effects of multiple OH-PAHs on blood pressure and lung function.
CONCLUSION
Exposure to multiple organic pollutants can adversely affect cardiopulmonary health. Oxidative stress is a key mediator of the effects of OH-PAHs on blood pressure and lung function.
Humans
;
Oxidative Stress/drug effects*
;
Male
;
Cross-Over Studies
;
Female
;
Young Adult
;
Environmental Pollutants/toxicity*
;
Environmental Exposure/adverse effects*
;
Biomarkers/blood*
;
Adult
;
Blood Pressure/drug effects*
;
Polycyclic Aromatic Hydrocarbons/urine*
;
Beijing
4.Construction and effectiveness evaluation of a closed-loop management system for dispensed oral drugs in the inpatient pharmacy based on SWOT analysis
Jia WANG ; Weihong GE ; Ruijuan XU ; Shanshan QIAN ; Xuemin SONG ; Xiangling SHENG ; Bin WU ; Li LI
China Pharmacy 2025;36(4):401-406
OBJECTIVE To improve the efficiency and quality of dispensed oral drug management in the inpatient pharmacy,and ensure the safety of drug use in patients.METHODS SWOT(strength,weakness,opportunity,threat)analysis method was used to analyze the internal strengths and weaknesses,as well as the external opportunities and threats in the construction of a closed-loop management system for dispensed oral drugs in the inpatient pharmacy of our hospital,and propose improvement strategies.RESULTS&CONCLUSIONS A refined,full-process,closed-loop traceability management system for dispensed oral drugs in the inpatient pharmacies was successfully established,which is traceable in origin,trackable in destination,and accountable in responsibility.After the application of this system,the registration rate of dispensed drug information and the correctness rate of registration content both reached 100%.The proportion of overdue drug varieties in the same period of 2024 decreased by 77.78%compared to March 2020,the inventory volume decreased by 29.50%compared to the first quarter of 2020,the per-bed medication volume decreased by 32.14%compared to the first quarter of 2020;the average workload per post in the same period of 2023 increased by 49.09%compared to 2019,the dispensing accuracy rate reached 100%,and the improvement rate of quality control problem increased by 25.25%compared to 2021.This system effectively improves the safety and accuracy of dispensed oral drug management in the inpatient pharmacy.
5.Standardized scheme for deploying and withdrawing surgical module of new-type tent hospital system
Zeng-biao SU ; Bin-hong PEI ; Er-xiang XU ; Hai-ying CHEN ; Jia-na CHEN ; Jin-shen PAN ; Yi-feng HUANG ; Qian XU
Chinese Medical Equipment Journal 2025;46(2):74-79
Objective To explore the scheme for the deployment and withdrawal of the surgical module of the new-type tent hospital system.Methods A set of standardized scheme for deploying and withdrawing the surgical module of the new-type tent hosital system was proposed and implemented in terms of labor division,operation precedure,operation technique and precaution.The operating time,number of operational errors and number of equipment damages were recorded for each of the five deployment and withdrawal operations before and after the program was executed,and the team members'immediate heart rate,percentage of maximum heart rate(MHR)and rating of perceived exercise(RPE)at the end of the operation were recorded after the program was implemented.SPSS 26.0 software was used for statistical analysis.Results The standardized scheme had the deployment time shortened from(85.15±11.430)min to(58.23±8.513)min,withdrawal time decreased from(65.36±9.369)min to(48.92±7.129)min,with the differences being statistically significant(P<0.05);the numbers of operatio-nal errors and equipment damages were both reduced when compared with those before the implementation of the schemce;the immediate heart rate of the team members at the end of the operation ranged from 43 to 157 beats/min,with an average value of 151.1 beats/min,the individual MHR percentages were from 75%to 87%,with an average value of 81.1%,and the RPE scores were from 14 to 17,with an average value of 15.3,which all could be categorized as moderate-operation intensity.Condusion The standardized deployment and withdrawal scheme for the surgical module meets the needs of actual combat and training assessment,and thus is worthy promoting in medical institutions equipped with the surgical module of the new-type tent hosital system.[Chinese Medical Equipment Journal,2025,46(2):74-79]
6.Study on performance evaluation method for lubricating coatings of intravascular catheters
Hong-jian CHEN ; Chong-chong AI ; Yuan-yu LI ; Li-ping HUANG ; Jia-qi NIE ; Chang-bin WANG ; Qian YANG ; Yu-xin BI ; Wen-bo LU
Chinese Medical Equipment Journal 2025;46(1):66-72
Three evaluation methods were recommended for the key properties of the intravascular catheter lubricating coating such as stability,lubricity and integrity,including insoluble particle test method,friction test procedure and appearance detection method.Fifteen batches of microcatheters produced by different manufacturers were selected for testing to clarify the three methods in test principle,step,result,characteristic.References were provided for the design,production,evaluation and regulation of intravascular catheters with lubricant coatings.[Chinese Medical Equipment Journal,2025,46(1):66-72]
7.Standardized scheme for deploying and withdrawing surgical module of new-type tent hospital system
Zeng-biao SU ; Bin-hong PEI ; Er-xiang XU ; Hai-ying CHEN ; Jia-na CHEN ; Jin-shen PAN ; Yi-feng HUANG ; Qian XU
Chinese Medical Equipment Journal 2025;46(2):74-79
Objective To explore the scheme for the deployment and withdrawal of the surgical module of the new-type tent hospital system.Methods A set of standardized scheme for deploying and withdrawing the surgical module of the new-type tent hosital system was proposed and implemented in terms of labor division,operation precedure,operation technique and precaution.The operating time,number of operational errors and number of equipment damages were recorded for each of the five deployment and withdrawal operations before and after the program was executed,and the team members'immediate heart rate,percentage of maximum heart rate(MHR)and rating of perceived exercise(RPE)at the end of the operation were recorded after the program was implemented.SPSS 26.0 software was used for statistical analysis.Results The standardized scheme had the deployment time shortened from(85.15±11.430)min to(58.23±8.513)min,withdrawal time decreased from(65.36±9.369)min to(48.92±7.129)min,with the differences being statistically significant(P<0.05);the numbers of operatio-nal errors and equipment damages were both reduced when compared with those before the implementation of the schemce;the immediate heart rate of the team members at the end of the operation ranged from 43 to 157 beats/min,with an average value of 151.1 beats/min,the individual MHR percentages were from 75%to 87%,with an average value of 81.1%,and the RPE scores were from 14 to 17,with an average value of 15.3,which all could be categorized as moderate-operation intensity.Condusion The standardized deployment and withdrawal scheme for the surgical module meets the needs of actual combat and training assessment,and thus is worthy promoting in medical institutions equipped with the surgical module of the new-type tent hosital system.[Chinese Medical Equipment Journal,2025,46(2):74-79]
8.Study on performance evaluation method for lubricating coatings of intravascular catheters
Hong-jian CHEN ; Chong-chong AI ; Yuan-yu LI ; Li-ping HUANG ; Jia-qi NIE ; Chang-bin WANG ; Qian YANG ; Yu-xin BI ; Wen-bo LU
Chinese Medical Equipment Journal 2025;46(1):66-72
Three evaluation methods were recommended for the key properties of the intravascular catheter lubricating coating such as stability,lubricity and integrity,including insoluble particle test method,friction test procedure and appearance detection method.Fifteen batches of microcatheters produced by different manufacturers were selected for testing to clarify the three methods in test principle,step,result,characteristic.References were provided for the design,production,evaluation and regulation of intravascular catheters with lubricant coatings.[Chinese Medical Equipment Journal,2025,46(1):66-72]
9.Experimental Study on the Mechanism of ACSL4 Inhibition of Sevoflurane-induced Neuronal Iron Death through the AMPK/mTOR Pathway
Cheng LIU ; Juan ZHAO ; Qian JIA ; Shengchun XIE ; Bin LUO ; Guanfeng WEI
Journal of Modern Laboratory Medicine 2024;39(6):67-72
Objective To investigate the role and mechanism of acyl-CoA syntbetase long chain family member 4(ACSL4)in Sevoflurane(Sev)induced neuronal cell damage.Methods Human neuroblastoma SH-SY5Y cells were used as the research object,and control group(dimethyl sulfoxide,10 μmol/L),Sev group and Sev+iron death inhibitor Ferrostatin-1(Fer-1,10 μmol/L)group were set up.CCK-8 method was used to detect cell activity in each group.4.1%Sev exposed postoperative cognitive dysfunction model was constructed in vitro and divided into Ctrol group,Sev group,Sev+si-NC group,Sev+si-ACSL4 group,and Sev+si-ACSL4+compound C group according to the transfection category.The contents of Malonaldehyde(MDA),4-hydroxynonenal(4-HNE),Glutathione(GSH)and Fe2+in each group were detected by colorimetry.The level of reactive oxygen species was detected using a 2',7'-dichlorofluorescein diacetate(DCFH-DA)fluorescent probe.Real time fluorescence quantitative PCR(qRT-PCR)was used to detect the mRNA expression of ACSL4,glutathione peroxidase 4(GPX4),and solute carrier family 7 member 11(SLC7A11).Protein immunoblotting was used to detect the expression of ACSL4,GPX4,adenosine 5'-monophosphate activated protein kinase(AMPK),phosphorylated(p)-AMPK,mammalian target of rapamycin(mTOR)and p-mTOR proteins.Results CCK-8 results showed that the cell viability of Sev group(0.41±0.11)was significantly lower than that of control group(0.98±0.07),and the cell viability of Sev+Fer-1 group(0.83±0.09)was significantly higher than that of Sev group(0.41±0.11),and the differences were statistically significant(t=7.572,5.118,all P<0.01).The levels of Fe2+,MDA,4-HNE,ROS and p-AMPK/AMPK ratios,as well as the mRNA and protein expression of ACSL4 in the Sev group cells,were higher than those in the Ctrol group(t=5.900,7.421,4.795,13.517,10.825,9.945,11.334),the GSH conten,p-mTOR/mTOR ratio,and mRNA and protein expression of SLC7A11 and GPX4 were lower than those in the Ctrol group(t=20.438,3.551,11.460,12.211,6.845,8.287),and the differences were statistically significant(all P<0.05)repectively.The levels of Fe2+,MDA,4-HNE,ROS,and p-AMPK/AMPK ratios,as well as the mRNA and protein expression of ACSL4 in the Sev+si-ACSL4 group,were lower than those in the Sev+si-NC group(t=3.818,3.164,3.054,4.465,13.088,7.918,9.737),the cell viability,GSH content,p-mTOR/mTOR ratio,and protein expression of SLC7A11 and GPX4 were higher than those in the Sev+si-NC group(t=2.912,7.248,7.574,20.092,5.915),and the differences were statistically significant(all P<0.05),respectively.The cell viability,GSH content,SLC7A11,and GPX4 protein expression in the Sev+si-ACSL4+compound C group were lower than those in the Sev+si-ACSL4 group(t=4.435,8.521,4.522,8.767),while the levels of Fe2+,MDA,4-HNE,and ROS were higher than those in the Sev+si-ACSL4 group(t=10.046,4.004,2.957,3.752),and the differences were statistically significant(all P<0.05).Conclusion Inhibiting ACSL4 expression attenuates Sev-induced iron death in SH-SY5Y cells by activating the AMPK/mTOR signaling pathway.
10.Antimicrobial resistance profile of clinical isolates in hospitals across China:report from the CHINET Antimicrobial Resistance Surveillance Program,2023
Yan GUO ; Fupin HU ; Demei ZHU ; Fu WANG ; Xiaofei JIANG ; Yingchun XU ; Xiaojiang ZHANG ; Fengbo ZHANG ; Ping JI ; Yi XIE ; Yuling XIAO ; Chuanqing WANG ; Pan FU ; Yuanhong XU ; Ying HUANG ; Ziyong SUN ; Zhongju CHEN ; Jingyong SUN ; Qing CHEN ; Yunzhuo CHU ; Sufei TIAN ; Zhidong HU ; Jin LI ; Yunsong YU ; Jie LIN ; Bin SHAN ; Yunmin XU ; Sufang GUO ; Yanyan WANG ; Lianhua WEI ; Keke LI ; Hong ZHANG ; Fen PAN ; Yunjian HU ; Xiaoman AI ; Chao ZHUO ; Danhong SU ; Dawen GUO ; Jinying ZHAO ; Hua YU ; Xiangning HUANG ; Wen'en LIU ; Yanming LI ; Yan JIN ; Chunhong SHAO ; Xuesong XU ; Wei LI ; Shanmei WANG ; Yafei CHU ; Lixia ZHANG ; Juan MA ; Shuping ZHOU ; Yan ZHOU ; Lei ZHU ; Jinhua MENG ; Fang DONG ; Zhiyong LÜ ; Fangfang HU ; Han SHEN ; Wanqing ZHOU ; Wei JIA ; Gang LI ; Jinsong WU ; Yuemei LU ; Jihong LI ; Qian SUN ; Jinju DUAN ; Jianbang KANG ; Xiaobo MA ; Yanqing ZHENG ; Ruyi GUO ; Yan ZHU ; Yunsheng CHEN ; Qing MENG ; Shifu WANG ; Xuefei HU ; Hua FANG ; Penghui ZHANG ; Bixia YU ; Ping GONG ; Haixia SHI ; Kaizhen WEN ; Yirong ZHANG ; Xiuli YANG ; Yiqin ZHAO ; Longfeng LIAO ; Jinhua WU ; Hongqin GU ; Lin JIANG ; Meifang HU ; Wen HE ; Jiao FENG ; Lingling YOU ; Dongmei WANG ; Dong'e WANG ; Yanyan LIU ; Yong AN ; Wenhui HUANG ; Juan LI ; Quangui SHI ; Juan YANG ; Abulimiti REZIWAGULI ; Lili HUANG ; Xuejun SHAO ; Xiaoyan REN ; Dong LI ; Qun ZHANG ; Xue CHEN ; Rihai LI ; Jieli XU ; Kaijie GAO ; Lu XU ; Lin LIN ; Zhuo ZHANG ; Jianlong LIU ; Min FU ; Yinghui GUO ; Wenchao ZHANG ; Zengguo WANG ; Kai JIA ; Yun XIA ; Shan SUN ; Huimin YANG ; Yan MIAO ; Jianping WANG ; Mingming ZHOU ; Shihai ZHANG ; Hongjuan LIU ; Nan CHEN ; Chan LI ; Cunshan KOU ; Shunhong XUE ; Jilu SHEN ; Wanqi MEN ; Peng WANG ; Xiaowei ZHANG ; Xiaoyan ZENG ; Wen LI ; Yan GENG ; Zeshi LIU
Chinese Journal of Infection and Chemotherapy 2024;24(6):627-637
Objective To monitor the susceptibility of clinical isolates to antimicrobial agents in healthcare facilities in major regions of China in 2023.Methods Clinical isolates collected from 73 hospitals across China were tested for antimicrobial susceptibility using a unified protocol based on disc diffusion method or automated testing systems.Results were interpreted using the 2023 Clinical & Laboratory Standards Institute (CLSI) breakpoints.Results A total of 445199 clinical isolates were collected in 2023,of which 29.0% were gram-positive and 71.0% were gram-negative.The prevalence of methicillin-resistant strains in Staphylococcus aureus,Staphylococcus epidermidis and other coagulase-negative Staphylococcus species (excluding Staphylococcus pseudintermedius and Staphylococcus schleiferi) (MRSA,MRSE and MRCNS) was 29.6%,81.9% and 78.5%,respectively.Methicillin-resistant strains showed significantly higher resistance rates to most antimicrobial agents than methicillin-susceptible strains (MSSA,MSSE and MSCNS).Overall,92.9% of MRSA strains were susceptible to trimethoprim-sulfamethoxazole and 91.4% of MRSE strains were susceptible to rifampicin.No vancomycin-resistant strains were found.Enterococcus faecalis had significantly lower resistance rates to most antimicrobial agents tested than Enterococcus faecium.A few vancomycin-resistant strains were identified in both E.faecalis and E.faecium.The prevalence of penicillin-susceptible Streptococcus pneumoniae was 93.1% in the isolates from children and and 95.9% in the isolates from adults.The resistance rate to carbapenems was lower than 15.0% for most Enterobacterales species except for Klebsiella,22.5% and 23.6% of which were resistant to imipenem and meropenem,respectively .Most Enterobacterales isolates were highly susceptible to tigecycline,colistin and polymyxin B,with resistance rates ranging from 0.6% to 10.0%.The resistance rate to imipenem and meropenem was 21.9% and 17.4% for Pseudomonas aeruginosa,respectively,and 67.5% and 68.1% for Acinetobacter baumannii,respectively.Conclusions Increasing resistance to the commonly used antimicrobial agents is still observed in clinical bacterial isolates.However,the prevalence of important crabapenem-resistant organisms such as crabapenem-resistant K.pneumoniae,P.aeruginosa,and A.baumannii showed a slightly decreasing trend.This finding suggests that strengthening bacterial resistance surveillance and multidisciplinary linkage are important for preventing the occurrence and development of bacterial resistance.

Result Analysis
Print
Save
E-mail