1.Tenecteplase versus alteplase in treatment of acute ST-segment elevation myocardial infarction: A randomized non-inferiority trial
Xingshan ZHAO ; Yidan ZHU ; Zheng ZHANG ; Guizhou TAO ; Haiyan XU ; Guanchang CHENG ; Wen GAO ; Liping MA ; Liping QI ; Xiaoyan YAN ; Haibo WANG ; Qingde XIA ; Yuwang YANG ; Wanke LI ; Juwen RONG ; Limei WANG ; Yutian DING ; Qiang GUO ; Wanjun DANG ; Chen YAO ; Qin YANG ; Runlin GAO ; Yangfeng WU ; Shubin QIAO
Chinese Medical Journal 2024;137(3):312-319
Background::A phase II trial on recombinant human tenecteplase tissue-type plasminogen activator (rhTNK-tPA) has previously shown its preliminary efficacy in ST elevation myocardial infarction (STEMI) patients. This study was designed as a pivotal postmarketing trial to compare its efficacy and safety with rrecombinant human tissue-type plasminogen activator alteplase (rt-PA) in Chinese patients with STEMI.Methods::In this multicenter, randomized, open-label, non-inferiority trial, patients with acute STEMI were randomly assigned (1:1) to receive an intravenous bolus of 16 mg rhTNK-tPA or an intravenous bolus of 8 mg rt-PA followed by an infusion of 42 mg in 90 min. The primary endpoint was recanalization defined by thrombolysis in myocardial infarction (TIMI) flow grade 2 or 3. The secondary endpoint was clinically justified recanalization. Other endpoints included 30-day major adverse cardiovascular and cerebrovascular events (MACCEs) and safety endpoints.Results::From July 2016 to September 2019, 767 eligible patients were randomly assigned to receive rhTNK-tPA ( n = 384) or rt-PA ( n = 383). Among them, 369 patients had coronary angiography data on TIMI flow, and 711 patients had data on clinically justified recanalization. Both used a –15% difference as the non-inferiority efficacy margin. In comparison to rt-PA, both the proportion of patients with TIMI grade 2 or 3 flow (78.3% [148/189] vs. 81.7% [147/180]; differences: –3.4%; 95% confidence interval [CI]: –11.5%, 4.8%) and clinically justified recanalization (85.4% [305/357] vs. 85.9% [304/354]; difference: –0.5%; 95% CI: –5.6%, 4.7%) in the rhTNK-tPA group were non-inferior. The occurrence of 30-day MACCEs (10.2% [39/384] vs. 11.0% [42/383]; hazard ratio: 0.96; 95% CI: 0.61, 1.50) did not differ significantly between groups. No safety outcomes significantly differed between groups. Conclusion::rhTNK-tPA was non-inferior to rt-PA in the effect of improving recanalization of the infarct-related artery, a validated surrogate of clinical outcomes, among Chinese patients with acute STEMI.Trial registration::www.ClinicalTrials.gov (No. NCT02835534).
2.National bloodstream infection bacterial resistance surveillance report(2022): Gram-positive bacteria
Chaoqun YING ; Yunbo CHEN ; Jinru JI ; Zhiying LIU ; Qing YANG ; Haishen KONG ; Haifeng MAO ; Hui DING ; Pengpeng TIAN ; Jiangqin SONG ; Yongyun LIU ; Jiliang WANG ; Yan JIN ; Yuanyuan DAI ; Yizheng ZHOU ; Yan GENG ; Fenghong CHEN ; Lu WANG ; Yanyan LI ; Dan LIU ; Peng ZHANG ; Junmin CAO ; Xiaoyan LI ; Dijing SONG ; Xinhua QIANG ; Yanhong LI ; Qiuying ZHANG ; Guolin LIAO ; Ying HUANG ; Baohua ZHANG ; Liang GUO ; Aiyun LI ; Haiquan KANG ; Donghong HUANG ; Sijin MAN ; Zhuo LI ; Youdong YIN ; Kunpeng LIANG ; Haixin DONG ; Donghua LIU ; Hongyun XU ; Yinqiao DONG ; Rong XU ; Lin ZHENG ; Shuyan HU ; Jian LI ; Qiang LIU ; Liang LUAN ; Jilu SHEN ; Lixia ZHANG ; Bo QUAN ; Xiaoping YAN ; Xiaoyan QI ; Dengyan QIAO ; Weiping LIU ; Xiusan XIA ; Ling MENG ; Jinhua LIANG ; Ping SHEN ; Yonghong XIAO
Chinese Journal of Clinical Infectious Diseases 2024;17(2):99-112
Objective:To report the results of national surveillance on the distribution and antimicrobial resistance profile of clinical Gram-positive bacteria isolates from bloodstream infections in China in 2022.Methods:The clinical isolates of Gram-positive bacteria from blood cultures in member hospitals of National Bloodstream Infection Bacterial Resistant Investigation Collaborative System(BRICS)were collected during January 2022 to December 2022. Antibiotic susceptibility tests were conducted by agar dilution or broth dilution methods recommended by Clinical and Laboratory Standards Institute(CLSI). WHONET 5.6 and SPSS 25.0 software were used to analyze the data.Results:A total of 3 163 strains of Gram-positive pathogens were collected from 51 member units,and the top five bacteria were Staphylococcus aureus( n=1 147,36.3%),coagulase-negative Staphylococci( n=928,29.3%), Enterococcus faecalis( n=369,11.7%), Enterococcus faecium( n=296,9.4%)and alpha-hemolyticus Streptococci( n=192,6.1%). The detection rates of methicillin-resistant Staphylococcus aureus(MRSA)and methicillin-resistant coagulase-negative Staphylococci(MRCNS)were 26.4%(303/1 147)and 66.7%(619/928),respectively. No glycopeptide and daptomycin-resistant Staphylococci were detected. The sensitivity rates of Staphylococcus aureus to cefpirome,rifampin,compound sulfamethoxazole,linezolid,minocycline and tigecycline were all >95.0%. Enterococcus faecium was more prevalent than Enterococcus faecalis. The resistance rates of Enterococcus faecium to vancomycin and teicoplanin were both 0.5%(2/369),and no vancomycin-resistant Enterococcus faecium was detected. The detection rate of MRSA in southern China was significantly lower than that in other regions( χ2=14.578, P=0.002),while the detection rate of MRCNS in northern China was significantly higher than that in other regions( χ2=15.195, P=0.002). The detection rates of MRSA and MRCNS in provincial hospitals were higher than those in municipal hospitals( χ2=13.519 and 12.136, P<0.001). The detection rates of MRSA and MRCNS in economically more advanced regions(per capita GDP≥92 059 Yuan in 2022)were higher than those in economically less advanced regions(per capita GDP<92 059 Yuan)( χ2=9.969 and 7.606, P=0.002和0.006). Conclusions:Among the Gram-positive pathogens causing bloodstream infections in China, Staphylococci is the most common while the MRSA incidence decreases continuously with time;the detection rate of Enterococcus faecium exceeds that of Enterococcus faecalis. The overall prevalence of vancomycin-resistant Enterococci is still at a low level. The composition ratio of Gram-positive pathogens and resistant profiles varies slightly across regions of China,with the prevalence of MRSA and MRCNS being more pronounced in provincial hospitals and areas with a per capita GDP≥92 059 yuan.
3.Dosimetric effect of calculation grid size on stereotactic body radiation therapy of lung cancer in helical tomotherapy planning system
Xia-Yu HANG ; Wan-Rong JIANG ; Yi-Kun LI ; Jun HU ; Yan ZHANG ; Ruo-Qi CAO ; Nan XU ; Lei WANG ; Jin-Da ZHOU ; Xiang-Dong SUN
Chinese Medical Equipment Journal 2024;45(2):52-57
Objective To investigate the dosimetric effects of different calculation grid size(CGS)in helical tomotherapy(HT)planning system on stereotactic body radiation therapy(SBRT)for non-small cell lung cancer(NSCLC).Methods Nine NSCLC patients receiving radiation therapy for the first time at some hospital from March 2019 to December 2022 were selected as the subjects.SBRT planning was carried out through the HT system with three different CGS plans(Fine,Normal,and Coarse)and the same pitch,modulation factor(MF)and optimization conditions,and the target area indexes of the three CGS plans were compared including conformity index(CI),homogeneity index(HI),dosimetric parameters of the organ at risk(OAR),point dose verification pass rate,treatment time,number of monitor units and Sinograms.SPSS 22.0 was used for statistical analysis.Results For target area HI,there weres significant differences between CGS Fine plan and Coarse plan and between CGS Normal plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan(P>0.05).For target area CI,there were significant differences between CGS Fine plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan and between CGS Normal plan and Coarse plan(P>0.05).For OAR dosimetric parameters,CGS Fine plan and Coarse plan had significant differences in heart Dmax and Dmean,esophageal Dmax and Dmean,V5,V20,V30 and Dmean of the whole lung and affected lung,V5 and Dmax of the affected lung and heart V10 and V30(P<0.05),CGS Normal plan and Coarse plan had obvious differences in esophageal Dmax(P<0.05),and the remained dosimetric parameters were not statistically significant(P>0.05).Fine,Normal and Coarse plans had the point dose verifica-tion pass rates being 0.96%,1.50%and 1.77%,respectively.In terms of treatment time and number of monitor units,there were significant differences between Fine plan and Coarse plan(P<0.05)while no statistical differences were found between Fine and Normal plans and between Normal and Coarse plans(P>0.05).Sinograms analyses showed Fine plan had evenly distributed segment color gradient,Coarse plan had areas of very dark and very light color gradients and Normal plan was somewhere in between.Conclusion Low CGS has to be used as much as possible to obtain accurate dose distribution during SBRT planning for NSCLC patients,which contributes to the execution of the radiation therapy plan and the prevention of ad-verse effects.[Chinese Medical Equipment Journal,2024,45(2):52-57]
4.Development of portable medical oxygen purity analyzer
Lin-Xia LI ; Jun-Bo GAO ; Rong FAN ; Ting WU ; Ya-Jiao XU ; Yan-Qi LIU ; Jin MA ; Yun-Ying WANG
Chinese Medical Equipment Journal 2024;45(3):36-40
Objective To develop a portable medical oxygen purity analyzer capable of real-time detection of multi-compo-nent gases in medical oxygen or aviation oxygen to ensure the safety of oxygen consumption.Methods The portable medical oxygen purity analyzer with STM3F103RC as the main controller involved in a management module,an oxygen detection module,a carbon monoxide/chlorine detection module,a flow/carbon dioxide detection module and a dew point detection module as its hardware components,which had its human-machine interface programmed with DGUS supervision,control and data acquisition(SCADA)software and system program developed with C language under Keil MDK environment.The performance verification of the analyzer developed was carried out in terms of oxygen detection error and stability and errors for measuring carbon monoxide,chlorine and carbon dioxide.Results The analyzer showed high precision when used to detect oxygen with high volume fraction,with long-term stability and the absolute error restrained within±0.1%;the erros for measuring carbon monoxide,chlorine and carbon dioxide were all limited within±5%FS to meet the desired requirements.Condusion The portable medical oxygen purity analyzer developed with high precision,stability and portability can be used for detection of medical oxygen and aviation oxygen.[Chinese Medical Equipment Journal,2024,45(3):36-40]
5.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
6.Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults (version 2024)
Qingde WANG ; Yuan HE ; Bohua CHEN ; Tongwei CHU ; Jinpeng DU ; Jian DONG ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Zhong GUAN ; Hua GUO ; Yong HAI ; Lijun HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Chunde LI ; Fang LI ; Feng LI ; Guohua LYU ; Li LI ; Qi LIAO ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Yong QIU ; Limin RONG ; Yong SHEN ; Huiyong SHEN ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Zhaoming YE ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Wei MEI ; Dingjun HAO ; Baorong HE
Chinese Journal of Trauma 2024;40(2):97-106
Ankylosing spondylitis (AS) combined with lower cervical fracture is often categorized into unstable fracture, with a high incidence of neurological injury and a high rate of disability and morbidity. As factors such as shoulder occlusion may affect the accuracy of X-ray imaging diagnosis, it is often easily misdiagnosed at the primary diagnosis. Non-operative treatment has complications such as bone nonunion and the possibility of secondary neurological damage, while the timing, access and choice of surgical treatment are still controversial. Currently, there are no clinical practice guidelines for the treatment of AS combined with lower cervical fracture with or without dislocation. To this end, the Spinal Trauma Group of Orthopedics Branch of Chinese Medical Doctor Association organized experts to formulate Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults ( version 2024) in accordance with the principles of evidence-based medicine, scientificity and practicality, in which 11 recommendations were put forward in terms of the diagnosis, imaging evaluation, typing and treatment, etc, to provide guidance for the diagnosis and treatment of AS combined with lower cervical fracture.
7.National bloodstream infection bacterial resistance surveillance report (2022) : Gram-negative bacteria
Zhiying LIU ; Yunbo CHEN ; Jinru JI ; Chaoqun YING ; Qing YANG ; Haishen KONG ; Haifeng MAO ; Hui DING ; Pengpeng TIAN ; Jiangqin SONG ; Yongyun LIU ; Jiliang WANG ; Yan JIN ; Yuanyuan DAI ; Yizheng ZHOU ; Yan GENG ; Fenghong CHEN ; Lu WANG ; Yanyan LI ; Dan LIU ; Peng ZHANG ; Junmin CAO ; Xiaoyan LI ; Dijing SONG ; Xinhua QIANG ; Yanhong LI ; Qiuying ZHANG ; Guolin LIAO ; Ying HUANG ; Baohua ZHANG ; Liang GUO ; Aiyun LI ; Haiquan KANG ; Donghong HUANG ; Sijin MAN ; Zhuo LI ; Youdong YIN ; Kunpeng LIANG ; Haixin DONG ; Donghua LIU ; Hongyun XU ; Yinqiao DONG ; Rong XU ; Lin ZHENG ; Shuyan HU ; Jian LI ; Qiang LIU ; Liang LUAN ; Jilu SHEN ; Lixia ZHANG ; Bo QUAN ; Xiaoping YAN ; Xiaoyan QI ; Dengyan QIAO ; Weiping LIU ; Xiusan XIA ; Ling MENG ; Jinhua LIANG ; Ping SHEN ; Yonghong XIAO
Chinese Journal of Clinical Infectious Diseases 2024;17(1):42-57
Objective:To report the results of national surveillance on the distribution and antimicrobial resistance profile of clinical Gram-negative bacteria isolates from bloodstream infections in China in 2022.Methods:The clinical isolates of Gram-negative bacteria from blood cultures in member hospitals of national bloodstream infection Bacterial Resistant Investigation Collaborative System(BRICS)were collected during January 2022 to December 2022. Antibiotic susceptibility tests were conducted by agar dilution or broth dilution methods recommended by Clinical and Laboratory Standards Institute(CLSI). WHONET 5.6 and SPSS 25.0 software were used to analyze the data.Results:During the study period,9 035 strains of Gram-negative bacteria were collected from 51 hospitals,of which 7 895(87.4%)were Enterobacteriaceae and 1 140(12.6%)were non-fermenting bacteria. The top 5 bacterial species were Escherichia coli( n=4 510,49.9%), Klebsiella pneumoniae( n=2 340,25.9%), Pseudomonas aeruginosa( n=534,5.9%), Acinetobacter baumannii complex( n=405,4.5%)and Enterobacter cloacae( n=327,3.6%). The ESBLs-producing rates in Escherichia coli, Klebsiella pneumoniae and Proteus spp. were 47.1%(2 095/4 452),21.0%(427/2 033)and 41.1%(58/141),respectively. The prevalence of carbapenem-resistant Escherichia coli(CREC)and carbapenem-resistant Klebsiella pneumoniae(CRKP)were 1.3%(58/4 510)and 13.1%(307/2 340);62.1%(36/58)and 9.8%(30/307)of CREC and CRKP were resistant to ceftazidime/avibactam combination,respectively. The prevalence of carbapenem-resistant Acinetobacter baumannii(CRAB)complex was 59.5%(241/405),while less than 5% of Acinetobacter baumannii complex was resistant to tigecycline and polymyxin B. The prevalence of carbapenem-resistant Pseudomonas aeruginosa(CRPA)was 18.4%(98/534). There were differences in the composition ratio of Gram-negative bacteria in bloodstream infections and the prevalence of main Gram-negative bacteria resistance among different regions,with statistically significant differences in the prevalence of CRKP and CRPA( χ2=20.489 and 20.252, P<0.001). The prevalence of CREC,CRKP,CRPA,CRAB,ESBLs-producing Escherichia coli and Klebsiella pneumoniae were higher in provinicial hospitals than those in municipal hospitals( χ2=11.953,81.183,10.404,5.915,12.415 and 6.459, P<0.01 or <0.05),while the prevalence of CRPA was higher in economically developed regions(per capita GDP ≥ 92 059 Yuan)than that in economically less-developed regions(per capita GDP <92 059 Yuan)( χ2=6.240, P=0.012). Conclusions:The proportion of Gram-negative bacteria in bloodstream infections shows an increasing trend,and Escherichia coli is ranked in the top,while the trend of CRKP decreases continuously with time. Decreasing trends are noted in ESBLs-producing Escherichia coli and Klebsiella pneumoniae. Low prevalence of carbapenem resistance in Escherichia coli and high prevalence in CRAB complex have been observed. The composition ratio and antibacterial spectrum of bloodstream infections in different regions of China are slightly different,and the proportion of main drug resistant bacteria in provincial hospitals is higher than those in municipal hospitals.
8.Preparation of a Fluorescent Nanosensor Based on NaYF4∶Yb3+,Er3+@SiO2 for Detection of Hydrogen Peroxide in Milk
Kong-Hao PENG ; Wei PENG ; An-Qi BAI ; Ling-Nan WANG ; Wei-Xin ZHAO ; Yue WU ; Wen GUO ; Shu-Rong LI ; Li-Xia LUO ; Pei-Jun MENG
Chinese Journal of Analytical Chemistry 2024;52(5):685-694
The rare-earth-elements-doped upconversion nanoparticles NaYF4:Yb3+,Er3+were synthesized by solvothermal method,and NaYF4:Yb3+,Er3+@SiO2 were prepared by coating SiO2 on the surface of NaYF4:Yb3+,Er3+by inverse microemulsion method in this work.Based on the fluorescence quenching principle between NaYF4∶Yb3+,Er3+@SiO2 and SQA-Fe3+,a NaYF4∶Yb3+,Er3+@SiO2-SQA-Fe3+fluorescence nanosensor was constructed for detection of trace hydrogen peroxide(H2O2).Under optimal conditions,the linear range of this method for detecting H2O2 was 1.8?84.0 μmol/L,with detection limit(3σ)of 0.47 μmol/L.The recoveries of H2O2 spiked in milk were 98.4%?99.7%.This method could be used for detection of H2O2 residue in milk samples,with advantages such as low detection limit,good stability and strong anti-interference ability.
9.Determination of Organophosphate Esters and Metabolites in Serum and Urine by Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry
Wen-Qi WU ; Xiao-Xia WANG ; Wen-Bin LIU ; Li-Rong GAO ; Yang YU ; Tian-Qi JIA ; Zhe-Yuan SHI ; Yun-Chen HE ; Jing-Lin DENG ; Chun-Ci CHEN
Chinese Journal of Analytical Chemistry 2024;52(9):1346-1354,中插29-中插35
A new method was developed for simultaneous detection of total 19 kinds of organophosphate esters(OPEs)and their diester metabolites(di-OPEs)in human serum(1.0 mL)and urine(1.5 mL)with low volume of samples.The target compounds were determined using ultra-high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS)after acetonitrile liquid-liquid extraction combined with purification using an ENVI-18 solid-phase extraction(SPE)column.OPEs and di-OPEs were separated using a Shim-pack GIST C18 column(100 mm×2.1 mm,2 μm)with a Shim-pack GIST-HP(G)C18 guard column.An electrospray ionization source(ESI)was employed in mass spectrometry analysis,with positive/negative ion mode using the multiple reaction monitoring(MRM).All target compounds were separated within 15 min,and exhibited good linear relationships in the concentration range of 2-100 ng/mL,with correlation coefficients(R2)above 0.994.The method detection limits(MDL)in serum ranged from 0.001 to 0.178 ng/mL and the MDL in urine ranged from 0.001 to 0.119 ng/mL.The recoveries of the analytes spiked in serum and urine matrices at two concentration levels were 30.5%-126.8%,with the relative standard deviations(RSDs)ranged from 1%to 23%.In addition,paired serum and urine samples from 11 patients were analyzed.For all samples tested,the internal standards of OPEs exhibited recoveries between 61%and 114%,whereas the internal standards for di-OPEs had recoveries ranging from 43%to 103%.OPEs and di-OPEs exhibited high detection frequencies in 22 serum and urine samples.Triethyl phosphate(TEP),tributyl phosphate(TBP),tris(2-ethylhexyl)phosphate(TEHP),tris(2-butoxyethyl)phosphate(TBEP),tris(1-chloro-2-propyl)phosphate(TCIPP),triphenyl phosphate(TPHP),tri-m-tolyl-phosphate(TMTP)and 2-ethylhexyl diphenyl phosphate(EHDPP)were universally detected in all serum samples.TCIPP was identified at the highest concentrations(median 0.548 ng/mL)in serum samples.In urine samples,the detection frequency for 12 kinds of target compounds reached 100%.Notably,TBP emerged as the predominant OPE in urine,demonstrating a median concentration of 0.506 ng/mL.Regarding di-OPEs,bis(2-chloroethyl)phosphate(BCEP)and bis(2-butoxyethyl)hydrogen phosphate(BBOEP)were the most abundant in urine,with median concentrations of 6.404 and 2.136 ng/mL,respectively.The total concentrations of OPEs and di-OPEs in serum and urine were 1.580-3.843 ng/mL and 5.149-17.537 ng/mL,respectively.These results not only confirmed the effectiveness of the method in detection of OPEs and di-OPEs in biological matrices,but also revealed the widespread presence of OPE compounds in human body and pointed to potential exposure risks.
10.Improvement Effect and Its Mechanism of Marmesin on Cognitive Impairment in Mice with Alzheimer's Disease
Zhuang-Zhuang LIU ; Shi-Jie SU ; Hong-Ying YANG ; Hai-Xia DING ; Ya-Ru PAN ; Han CAI ; Lei-Jie LIN ; Wei-Rong LI ; Qi WANG
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(10):2758-2768
Objective To investigate the improvement effect and mechanism of marmesin on cognitive impairment in Alzheimer's disease(AD)mice.Methods Fifty mice were randomly divided into five groups:blank group,model group,low-and high-dose marmesin groups and donepezil(positive drug)group,with 10 mice in each group.After 21 days of continuous administration,except for the blank group,the mice in other groups were given intraperitoneal injection of scopolamine to establish the AD model.Network pharmacology was used to construct the protein-protein interaction(PPI)network of common targets of marmesin in the treatment of AD,and gene ontology(GO)and Kyoto Encyclopedia of Genes and Genomes(KEGG)enrichment analysis were performed to provide further research direction.The cognitive function of AD model mice was evaluated by Morris water maze,open field test and new object recognition test.Nissl staining was used to observe the damage of hippocampal neurons.The levels of acetylcholine(Ach),acetylcholine transferase(ChAT),acetylcholinesterase(AChE),reactive oxygen species(ROS),malondialdehyde(MDA)and catalase(CAT)in hippocampus of mice were detected by kit.The protein expression levels of interleukin 6(IL-6),interleukin 1β(IL-1 β),tumor necrosis factor α(TNF-α),nuclear factor E2-related factor 2(NRF2),silent information regulator homologous protein 3(SIRT3),Kelch-like ECH-associated protein 1(KEAP1),quinone oxidoreductase 1(NQO1)and heme oxygenase 1(HO-1)in hippocampus were detected by Western Blot.Results Compared with the model group,the latency of Morris water maze test was significantly shortened in the high-dose marmesin group,the time of entering the target area in the open field new object test and the movement distance in the central area of the open field were prolonged,the number of neurons in the hippocampal CA1 and CA3 regions was significantly increased,the levels of ChAT and Ach in the hippocampus were significantly increased,AChE level was significantly decreased,CAT level was significantly increased,ROS and MDA levels were significantly decreased,TNF-α expression level was decreased,SIRT3 and HO-1 expression levels were increased,and KE AP1 protein expression level was decreased,the differences being statistically significant(P<0.05 or P<0.01 or P<0.001).Conclusion Marmesin can effectively improve the learning and memory impairment of AD mice,and its mechanism may be related to the activation of NRF2/SIRT3 signaling pathway,thereby alleviating oxidative stress level and neuroinflammation,and repairing cholinergic neuron function.

Result Analysis
Print
Save
E-mail