1.Comparative study on effectiveness of different puncture methods of flexible bone cement delivery device in treatment of osteoporotic vertebral upper 1/3 compression fractures.
Tangbo LI ; Kun LIU ; Nan ZHANG ; Guobing HAO ; Zexing ZHU ; Lin QIAO ; Diyu SONG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):470-477
OBJECTIVE:
To compare the effectiveness of different puncture methods of the flexible bone cement delivery device in unilateral percutaneous curved vertebroplasty for osteoporotic vertebral upper 1/3 compression fractures.
METHODS:
A retrospective analysis was conducted on the clinical data of 67 patients with osteoporotic vertebral upper 1/3 compression fractures who were admitted and met the selection criteria between January 2023 and April 2024. The patients were divided into two groups based on the puncture method of the flexible bone cement delivery device: the oblique puncture group ( n=37) and the parallel puncture group ( n=30). There was no significant difference ( P>0.05) between the two groups in terms of gender, age, bone mineral density (T value), distribution of fractured vertebrae, time from injury to operation, and preoperative visual analogue scale (VAS) score for pain, Oswestry disability index (ODI), anterior vertebral height of the fractured vertebra, and Cobb angle of the fractured vertebra. The following parameters were compared between the two groups: operation time, incidence of secondary puncture, incidence of bone cement leakage, volume of injected bone cement, bone cement distribution score, as well as VAS score, ODI, anterior vertebral height of the fractured vertebra, and Cobb angle of the fractured vertebra at 1 day after operation and at last follow-up.
RESULTS:
Two cases in the oblique puncture group and 7 cases in the parallel puncture group underwent secondary puncture during operation, and the difference in the incidence of secondary puncture was significant ( P<0.05). No complications such as bone cement hypersensitivity, bone cement embolism, nerve injury, or epidural hematoma occurred in both groups. There was no significant difference in operation time, volume of injected bone cement, incidence of bone cement leakage, distribution score and rating of bone cement between the two groups ( P>0.05). All patients were followed up 6-18 months (mean, 12.0 months), and there was no significant difference in the follow-up time between the two groups ( P>0.05). No further fracture collapse or compression occurred in the fractured vertebra during follow-up. Both groups exhibited significant improvements in VAS score, ODI, anterior vertebral height, and Cobb angle of the fractured vertebra after operation compared to baseline ( P<0.05). There were also significant differences between the two time points after operation ( P<0.05). However, there was no significant difference in the above indicators between the two groups ( P>0.05).
CONCLUSION
For osteoporotic vertebral upper 1/3 compression fractures treated with unilateral percutaneous curved vertebroplasty, both oblique and parallel puncture methods of the flexible bone cement delivery device can effectively relieve pain, but the former is more conducive to reducing the incidence of secondary puncture.
Humans
;
Bone Cements/therapeutic use*
;
Fractures, Compression/surgery*
;
Retrospective Studies
;
Vertebroplasty/instrumentation*
;
Osteoporotic Fractures/surgery*
;
Spinal Fractures/surgery*
;
Female
;
Male
;
Aged
;
Middle Aged
;
Treatment Outcome
;
Punctures/methods*
;
Aged, 80 and over
2.Clinical application of bilateral targeted puncture based on vertebral osteodense zone in percutaneous vertebroplasty.
Bao-Xin JIA ; Jing JU ; Cheng-Zhou LIU ; Xiao-Qiang GAO ; Ting WANG
China Journal of Orthopaedics and Traumatology 2025;38(7):729-736
OBJECTIVE:
To investigate the clinical efficacy of bilateral targeted puncture in percutaneous vertebroplasty(PVP) based on the vertebral osteodense zone.
METHODS:
A retrospective analysis was conducted on 76 patients with fresh symptomatic osteoporotic vertebral compression fractures, characterized by the presence of a dense zone, who underwent percutaneous vertebroplasty (PVP) between January 2021 and December 2021. All patients involved single-level vertebral fractures. There were 19 males and 57 females, aged from 62 to 88 years old, with an average of (68.5±12.5) years old. All patients underwent bilateral transpedicular puncture procedures. Preoperative CT or MRI was utilized to ascertain the relative position of the bone osteodense zone within the vertebral body (specifically, whether this zone is situated in the upper one-third or one-quarter of the left or right sagittal plane). Considering the head and tail regions of the dense zone as puncture targets, the puncture points and paths were meticulously planned, and the working channel was subsequently established. Under continuous monitoring by a C-arm X-ray machine, bone cement was carefully and gradually injected. The operation time, bone cement injection volume, and bone cement leakage were recorded. The visual analogue scale (VAS) and Oswestry disablity index (ODI) were used to evaluate the effectiveness of the operation. ODI and anterior height (AH) of the vertebral body were used to evaluate the efficacy.
RESULTS:
All patients successfully completed the surgery and were followed up for (8.0±1.0) months. The operation time was (36.57±11.25) min, the volume of bone cement injection was(6.07±1.19) ml, and 21 patients of bone cement leakage. There were 3 patients with the VAS exceeded 4 points two days postoperatively, indicating suboptimal pain management. At the three time points of pre-operation, 2 days post-operation and 6 months post-operation, the VAS scores were(7.82±1.29), (2.11±0.44), and (2.04±0.67) respectively;the ODI percentages were(75.65±7.23)%, (29.45±4.16)%, and(28.68±5.62)%;and the AH values were (11.02±1.30), (12.87±3.91), and (12.91±3.86) cm. The differences were all statistically significant(P<0.05). The aforementioned three indices demonstrated significant improvement at both 2 days and 6 months post-operation (all P<0.05). There were no statistically significant differences in these indices between the 2-day and 6-month post-operative periods(P>0.05). The postoperative outcome was satisfactory and durable, with no evidence of vertebral height reduction.
CONCLUSION
Bilateral targeted puncture based on the osteodense dense zone within the vertebral body can achieve bilateral symmetrical and upright full vertebral bone cement reinforcement without increasing bone cement leakage, achieving good early efficacy and preventing late vertebral collapse. This has positive significance for further improving the efficacy of percutaneous vertebroplasty.
Humans
;
Male
;
Female
;
Vertebroplasty/methods*
;
Aged
;
Middle Aged
;
Aged, 80 and over
;
Retrospective Studies
;
Spinal Fractures/surgery*
;
Fractures, Compression/surgery*
;
Punctures
;
Bone Cements
;
Osteoporotic Fractures/surgery*
3.Clinical application of angle-settable linear laser auxiliary instrument in vertebral puncture.
Li-Qi RUAN ; Ling WANG ; Jin-Tao HU ; Pi-Sheng QU
China Journal of Orthopaedics and Traumatology 2025;38(11):1139-1144
OBJECTIVE:
To compare the effects of bilateral vertebral puncture guided by an angle-adjustable linear laser auxiliary device versus free-hand bilateral vertebral puncture.
METHODS:
A retrospective analysis was conducted on the clinical data of 47 patients who underwent thoracolumbar percutaneous kyphoplasty(PKP) from July 2022 to July 2023. All patients received bilateral percutaneous kyphoplasty, among whom 27 cases underwent conventional free-hand puncture (conventional puncture group) and 20 cases underwent puncture guided by a laser auxiliary device (auxiliary puncture group). In the conventional puncture group, there were 11 males and 16 females, with an average age of (69.6±5.1) years and a disease duration of (6.5±3.8) days;the fractured vertebrae were T11-T12 in 13 cases and L1-L2 in 14 cases. In the auxiliary puncture group, there were 7 males and 13 females, with an average age of (70.8±5.6) years and a disease duration of (6.4±3.8) days;the fractured vertebrae were T11-T12 in 7 cases and L1-L2 in 13 cases. The operation time, total blood loss, intraoperative fluoroscopy times, fluoroscopy duration, radiation dose, puncture success rate, and surgical complications were compared between the two groups. The visual analogue scale (VAS) was used to evaluate low back pain before surgery, 2 days after surgery, and 1 year after surgery.
RESULTS:
All patients achieved successful puncture, with good postoperative wound healing and no complications. The operation time of the auxiliary puncture group was (12.1±2.6) minutes, which was shorter than that of the conventional puncture group (14.1±2.8) minutes. The total blood loss of the auxiliary puncture group was (228.5±35.8) ml, less than that of the conventional puncture group (257.0±48.3) ml. The fluoroscopy times, fluoroscopy duration, and radiation dose of the auxiliary puncture group were (5.4±1.3) times, (15.9±3.3) seconds, and (159.4±37.4) μSv, respectively, all lower than those of the conventional puncture group (6.4±1.6) times, (18.8±4.6) seconds, (192.2±48.5) μSv, with statistically significant differences(P<0.05). There were no statistically significant differences in low back VAS scores between the two groups before surgery, 2 days after surgery, or 1 year after surgery(P>0.05).
CONCLUSION
Both laser auxiliary device-guided vertebral puncture and free-hand vertebral puncture have high success rates and similar postoperative curative effects. However, the laser auxiliary device-guided puncture has shorter operation time, less blood loss, and lower radiation hazard.
Humans
;
Male
;
Female
;
Aged
;
Retrospective Studies
;
Middle Aged
;
Punctures/methods*
;
Kyphoplasty/instrumentation*
;
Spinal Fractures/surgery*
;
Lasers
;
Thoracic Vertebrae/injuries*
;
Lumbar Vertebrae/injuries*
4.Preliminary experience of ultrasound-guided puncture combined with endoscopic cauterization in the treatment of neonatal pyriform sinus fistula.
Yang ZHANG ; Jing BI ; Bo YU ; Yong FU
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(2):152-157
Objective:To explore the diagnosis and minimal invasive treatment of neonatal pyriform sinus fistula. Methods:A retrospective analysis was conducted on the clinical data of newborns diagnosed with pyriform sinus fistula in the Children's Hospital, Zhejiang University School of Medicine from January 2016 to December 2023, including the diagnostic process and treatment methods. Results:There were 8 children, 2 males and 6 females, with 7 cases on the left side and 1 case on the right side. Six cases revealed a lump in the fetal neck during prenatal examination, and two cases were found to have a neck mass after birth. All cases presented with varying degrees of respiratory disorders. After admission, all patients underwent neck ultrasound and contrast-enhanced CT examination. Neck ultrasound showed cystic masses, with 3 of the cysts accompanied by septa, and an air-fluid level was observed in the cysts in 6 cases from contrast-enhanced CT. All patients underwent ultrasound-guided neck mass puncture and/or tube placement combined with endoscopic electrocauterization. The cystic fluid was found to be yellow and thin, with no signs of infection. The surgical operations were uneventful, and the follow-up time ranged from 12 to 72 months postoperatively. There were no complications such as hoarseness, and no recurrence cases were reported. Conclusion:Neonatal pyriform sinus fistula is often characterized by a large cystic mass in the neck combined with respiratory depression. The presence of an air-fluid level in the cyst from contrast-enhanced CT can be considered an important basis for early diagnosis of pyriform sinus fistula. Ultrasound-guided puncture combined with endoscopic electrocauterization is minimally invasive and safe, making it a suitable minimal invasive treatment for neonatal pyriform sinus fistula.
Humans
;
Female
;
Male
;
Pyriform Sinus/surgery*
;
Retrospective Studies
;
Infant, Newborn
;
Cautery/methods*
;
Endoscopy
;
Fistula/surgery*
;
Punctures
;
Tomography, X-Ray Computed
5.Updated techniques of guidance in prostatic biopsy puncture.
National Journal of Andrology 2024;30(12):1141-1146
Pathological results are a gold standard for the diagnosis of prostate cancer (PCa), one of the ways to obtain the pathological tissue is prostate biopsy. With the advances in detection technology, biochemical examination and medical imaging have greatly improved the detection rate of PCa. However, the final therapeutic option depends on pathological results, and therefore the precision of prostate biopsy and puncturing technique is highly required. Specific requirements include pinpoint positioning of the lesion and exact sampling of the positive tissue to reduce pain caused by unnecessary invalid punctures, accurate navigation for deep lesions to avoid damage to the urethra and bladder and reduce bleeding and other complications. Current development of medical imaging and artificial intelligence has significantly promoted biopsy puncture techniques. This review updates the application of image fusion and robotics in prostate biopsy.
Humans
;
Male
;
Prostatic Neoplasms/pathology*
;
Prostate/pathology*
;
Image-Guided Biopsy/methods*
;
Punctures/methods*
;
Biopsy, Needle/methods*
;
Robotics
6.Application of different puncture techniques to inject bone cement in osteoporotic vertebral compression fractures.
China Journal of Orthopaedics and Traumatology 2023;36(1):86-91
OBJECTIVE:
To study the application of different puncture techniques to inject bone cement in osteoporotic vertebral compression fractures (OVCFs).
METHODS:
The clinical data of 282 patients with OVCFs treated from January 2017 to December 2019 were collected for a retrospective study. According to the surgical plan the patients were divided into group A and B, with 141 cases in each group. In group A, extreme lateral puncture was used to inject bone cement through unilateral puncture and bilateral puncture. In group B, bone cement was injected through unilateral pedicle puncture through pedicle approach. The operation status(operation time, radiation exposure time, bone cement injection volume, hospital stay) and complications were observed between two groups. Before operation and 6, 12 months after operation, the pain mediators such as serotonin 5-hydroxytryptamine (5-HT), prostaglandin E2(PGE2), substance P(SP) were compared, bone mineral density, anatomical parameters of the injured vertebrae (height of the anterior edge of the vertebral body, height of the posterior edge of the vertebral body, Cobb angle), visual analogue scale (VAS) and Oswestry disability index (ODI) were evaluated between two groups.
RESULTS:
There were no significant difference in operation time, radiation exposure time, hospital stay between two groups (P>0.05). The amount of bone cement injected in group A was greater than that in group B (P<0.05). The serum 5-HT, SP and PGE2 levels of group A were lower than those of group B at 12 months after operation (P<0.05). The height of anterior edge and height of the posterior edge of vertebral body in group A were greater than those of group B at 12 months after operation, Cobb angle of group A was smaller than that of group B, VAS and ODI were lower than those of group B(P<0.05). There was no significant difference in bone mineral density between two groups at 6 and 12 months postoperatively(P<0.05). There was no significant difference between two groups in postoperative complications (P>0.05).
CONCLUSION
Compared with unilateral puncture of the pedicle approach, unilateral puncture and bilateral cement injection technique is more conducive to the recovery of the injured vertebral anatomy and function, and do not prolong operation time, radiation exposure time, hospital stay, nor do increase the risk of nerve damage and bone cement leakage, and postoperative bone metabolism and bone mineral density are improved well, which is a safe and reliable surgical method for the treatment of OVCFs.
Humans
;
Spinal Fractures/surgery*
;
Fractures, Compression/surgery*
;
Bone Cements
;
Vertebroplasty/methods*
;
Retrospective Studies
;
Dinoprostone
;
Serotonin
;
Treatment Outcome
;
Osteoporotic Fractures/surgery*
;
Kyphoplasty
;
Punctures
7.Design and application of a B-ultrasound-guided deep vein puncture precise positioning device.
Qiaoqiao PENG ; Xiangying YANG ; Yuan LI ; Weiying DAI ; Jianrong WANG
Chinese Critical Care Medicine 2023;35(10):1099-1100
Deep venipuncture catheterization is a routine and basic operation in the treatment of critically ill patients, and it is the most effective way to quickly correct the shock. Clinical B-ultrasound guided deep vein catheters can improve the success rate of puncture, but in the process of operation, the short axis needs to be replaced by the long axis. In the replacement process, the stability of the novice is insufficient, the positioning is difficult, and the operation time is too long. If only short axis puncture is used, it is impossible to know whether the current position of the puncture needle, and the puncture may be too deep and stray into the artery. The accuracy of the 45 degree angle of the injection point requires a very experienced operator. In view of the above shortcomings, doctors in the department of critical care medicine of Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine designed a B-ultrasound puncture equipment, which has obtained the National Invention Patent of China (ZL 2016 1 0571557.X). The device is composed of B-ultrasound probe fixing frame, sliding scale plate, simulation slide rule, puncture needle, sliding device. By sliding device the angle of the pinhole channel, it is conducive to the accurate positioning of the puncture target, optimizing the operation procedure, improving the puncture speed and accuracy, effectively reducing the occurrence of puncture complications, ensuring patient safety, reducing unnecessary waste of human and material resources. It can reduce the workload of medical staff and is worthy of clinical practice.
Humans
;
Catheterization, Central Venous/methods*
;
Ultrasonography, Interventional/methods*
;
Ultrasonography
;
Punctures/methods*
;
Needles
8.Comparison of Surgical Tracheostomy and Percutaneous Dilatational Tracheostomy in Intensive Care Unit Patients
Hyun Il SHIN ; Kyung Il JANG ; Kyung Min KIM ; Inn Chul NAM
Korean Journal of Otolaryngology - Head and Neck Surgery 2019;62(5):288-293
BACKGROUND AND OBJECTIVES: Percutaneous dilatational tracheostomy (PDT) has become an increasingly popular method of establishing an airway for patients in need of chronic ventilator assistance. The aim of this study is to assess and compare two main strategies for doing tracheostomy: traditional open surgical tracheostomy (ST) and PDT. MATERIALS AND METHOD: We retrospectively reviewed medical records of 43 patients who underwent tracheostomy between the years 2016 and 2017. All patients were under intensive care unit (ICU) care and referred to the department of otolaryngology for tracheostomy. All tracheostomies were performed at the bedside using either percutaneous dilatational technique or open surgical technique by a single surgeon. In cases of PDT, either blind puncture technique without any guidance or laryngoscopy-guided puncture technique was used. Demographic and procedural variables and complications were compared between the two groups. RESULTS: PDT was performed in 29 patients and ST in 14 patients. Of those who underwent PDT, 15 patients received the blind puncture technique and 14 patients laryngoscopy-guided puncture technique. The cricosternal distance was longer and the amount of blood loss and duration of the procedure was lesser in the PDT group. In the PDT group, there was no difference in blood loss nor in the duration of the procedure according to the puncture technique, whereas critical complications occurred more frequently when the blind technique was used. Subjective difficulty of the procedure is predictive of complications. CONCLUSION: The study show that PDT is a useful and safe procedure for ICU patients. Also, guidance on using the flexible laryngoscopy during PDT can prevent severe complications.
Critical Care
;
Humans
;
Intensive Care Units
;
Laryngoscopy
;
Medical Records
;
Methods
;
Otolaryngology
;
Punctures
;
Retrospective Studies
;
Tracheostomy
;
Ventilators, Mechanical
9.Coil-Protected Technique for Liquid Embolization in Neurovascular Malformations
Keun Young PARK ; Jin Woo KIM ; Byung Moon KIM ; Dong Joon KIM ; Joonho CHUNG ; Chang Ki JANG ; Jun Hwee KIM
Korean Journal of Radiology 2019;20(8):1285-1292
OBJECTIVE: To evaluate the safety and efficacy of the coil-protected technique for liquid embolization in neurovascular malformations. MATERIALS AND METHODS: Twenty-two patients who underwent coil-protected liquid embolization for symptomatic cranial (n = 13) and spinal (n = 9) arteriovenous fistula (AVF) or arteriovenous malformations (AVMs) were identified. A total of 36 target feeder vessels were embolized with N-butyl cyanoacrylate and/or Onyx (Medtronic). This technique was used to promote delivery of a sufficient amount of liquid embolic agent into the target shunt or nidus in cases where tortuous feeding arteries preclude a microcatheter wedging techniqu and/or to prevent reflux of the liquid embolic agent in cases with a short safety margin. The procedure was considered technically successful if the target lesion was sufficiently filled with liquid embolic agent without unintentional reflux. Angiographic and clinical outcomes were retrospectively evaluated. RESULTS: Technical success was achieved for all 36 target feeders. Post-embolization angiographies revealed complete occlusion in 16 patients and near-complete and partial occlusion in three patients each. There were no treatment-related complications. Of the six patients who showed near-complete or partial occlusion, five received additional treatments: two received stereotactic radiosurgery for cerebral AVM, two underwent surgical removal of cerebral AVM, and one underwent additional embolization by direct puncture for a mandibular AVM. Finally, all patients showed complete (n = 19) or near-complete (n = 3) occlusion of the target AVF or AVM on follow-up angiographies. The presenting neurological symptoms improved completely in 15 patients (68.2%) and partially in seven patients (31.8%). CONCLUSION: The coil-protected technique is a safe and effective method for liquid embolization, especially in patients with various neurovascular shunts or malformations who could not be successfully treated with conventional techniques.
Angiography
;
Arteries
;
Arteriovenous Fistula
;
Arteriovenous Malformations
;
Cyanoacrylates
;
Follow-Up Studies
;
Humans
;
Methods
;
Punctures
;
Radiosurgery
;
Retrospective Studies
10.Various Treatment Modalities in Hepatic Hydrothorax: What Is Safe and Effective?
Jae Hyun YOON ; Hee Joon KIM ; Chung Hwan JUN ; Sung Bum CHO ; Yochun JUNG ; Sung Kyu CHOI
Yonsei Medical Journal 2019;60(10):944-951
PURPOSE: Hepatic hydrothorax is a complication of decompensated liver cirrhosis that is difficult and complex to manage. Data concerning the optimal treatment method, other than liver transplantation, are limited. This study aimed to compare the clinical features and outcomes of patients treated with various modalities, while focusing on surgical management and pigtail drainage. MATERIALS AND METHODS: Forty-one patients diagnosed with refractory hepatic hydrothorax between January 2013 and December 2017 were enrolled. RESULTS: The mean Child-Turcotte-Pugh and model for end stage liver disease scores of the enrolled patients were 10.1 and 19.7, respectively. The patients underwent four modalities: serial thoracentesis (n=11, 26.8%), pigtail drainage (n=16, 39.0%), surgery (n=10, 24.4%), and liver transplantation (n=4, 9.8%); 12-month mortality rate/median survival duration was 18.2%/868 days, 87.5%/79 days, 70%/179 days, and 0%/601.5 days, respectively. Regarding the management of refractory hepatic hydrothorax, surgery group required less frequent needle puncture (23.5 times in pigtail group vs. 9.3 times in surgery group), had a lower occurrence of hepatorenal syndrome (50% vs. 30%), and had a non-inferior cumulative overall survival (402.1 days vs. 221.7 days) compared to pigtail group. On multivariate analysis for poor survival, body mass index <19 kg/m², refractory hepatic hydrothorax not managed with liver transplantation, Child-Turcotte-Pugh score >10, and history of severe encephalopathy (grade >2) were associated with poor survival. CONCLUSION: Serial thoracentesis may be recommended for management of hepatic hydrothorax and surgical management can be a useful option in patients with refractory hepatic hydrothorax, alternative to pigtail drainage.
Body Mass Index
;
Brain Diseases
;
Drainage
;
End Stage Liver Disease
;
Fibrosis
;
Hepatorenal Syndrome
;
Humans
;
Hydrothorax
;
Liver Cirrhosis
;
Liver Transplantation
;
Methods
;
Mortality
;
Multivariate Analysis
;
Needles
;
Punctures
;
Thoracentesis

Result Analysis
Print
Save
E-mail