1.Integrated management during the perinatal period for total anomalous pulmonary venous connection.
Yi SUN ; Si-Lin PAN ; Zhi-Xian JI ; Gang LUO ; Hao WAN ; Tao-Tao CHEN ; Ai ZHANG ; Rui CHEN ; Quan-Sheng XING
Chinese Journal of Contemporary Pediatrics 2023;25(5):502-507
OBJECTIVES:
To evaluate the clinical effectiveness of integrated management during the perinatal period for fetuses diagnosed with total anomalous pulmonary venous connection (TAPVC) by prenatal echocardiography.
METHODS:
Clinical data of 64 cases of TAPVC fetuses diagnosed by prenatal echocardiography and managed with integrated perinatal care in Qingdao Women and Children's Hospital from January 2017 to December 2021 were retrospectively analyzed. Integrated perinatal care included multidisciplinary collaboration among obstetrics, fetal medicine, ultrasound, pediatric cardiology, pediatric anesthesia, and neonatology.
RESULTS:
Among the 64 TAPVC fetuses, there were 29 cases of supracardiac type, 27 cases of intracardiac type, 2 cases of infracardiac type, and 6 cases of mixed type. Chromosomal analysis was performed in 42 cases, and no obvious abnormalities were found. Among the 64 TAPVC fetuses, 37 were induced labor, and 27 were followed up until term birth. Among the 27 TAPVC cases, 2 cases accepted palliative care, 2 cases were referred to another hospital for treatment and lost to follow-up, while the remaining 23 cases underwent primary repair surgery. One case died within 6 months after the operation due to low cardiac output syndrome, while the other 22 cases were followed up for (2.1±0.3) years with good outcomes (2 cases underwent a second surgery within 1 year after the first operation due to anastomotic stenosis or pulmonary vein stenosis).
CONCLUSIONS
TAPVC fetuses can achieve good outcomes with integrated management during the perinatal period.
Female
;
Humans
;
Pregnancy
;
Echocardiography
;
Heart Defects, Congenital/surgery*
;
Pulmonary Veins/surgery*
;
Retrospective Studies
;
Scimitar Syndrome/surgery*
;
Infant, Newborn
2.Diagnosis and treatment of a child with alveolar capillary dysplasia with misalignment of pulmonary veins due to variant of FOXF1 gene.
Weifeng ZHANG ; Zhiyong LIU ; Weiru LIN ; Fengfeng ZHANG ; Jinglin XU ; Xiaoqing LI ; Ruiquan WANG ; Lianqiang WU ; Dongmei CHEN
Chinese Journal of Medical Genetics 2023;40(9):1171-1175
OBJECTIVE:
To explore the diagnosis, treatment and genetic characteristics of a neonate with severe pulmonary hypertension and respiratory failure.
METHODS:
Perinatal history, clinical manifestations, laboratory finding and diagnosis and treatment data of the child were collected. Whole exome sequencing was carried out for the child, and Sanger sequencing was used to verify the candidate variants.
RESULTS:
The female neonate has developed progressive respiratory failure and refractory pulmonary hypertension shortly after birth. Conventional treatment such as mechanical ventilation, vasoactive drugs, and inhaled nitric oxide were ineffective. She has developed sustained pulmonary hypertension after weaning from extracorporeal membrane oxygenation therapy, and had died after the treatment had ceased. Whole exome sequencing revealed that she has harbored a heterozygous de novo variant of c.682_683insGCGGCGGC (p.G234Rfs*148) of the FOXF1 gene, which was predicted as pathogenic based on guidelines from the American College of Medical Genetics and Genomics (ACMG), with evidence items of PVS1_Strong+PM2_Supporting+PS2. Based on her clinical manifestations and result of genetic testing, the child was diagnosed with alveolar capillary dysplasia with misalignment of the pulmonary veins (ACD/MPV).
CONCLUSION
Discovery of the c.682_683insGCGGCGGC (p.G234 Rfs*148) variant of the FOXF1 gene has expanded the mutational spectrum of the FOXF1 gene, which has facilitated implementation of specific treatment and provided a basis for clinical diagnosis and genetic counseling.
Female
;
Humans
;
Child
;
Infant, Newborn
;
Pregnancy
;
Persistent Fetal Circulation Syndrome/therapy*
;
Hypertension, Pulmonary
;
Pulmonary Veins
;
Forkhead Transcription Factors/genetics*
5.Progress in the Treatment of Tachyarrhythmia by Pulsed Electric Field Ablation Catheter Ablation.
Zhihong ZHAO ; Yonggang CHEN ; Zhongping NING ; Xinhua CHEN
Chinese Journal of Medical Instrumentation 2021;45(5):517-523
Pulsed electric field(PEF) provides high-energy instantaneous pulse and release energy to myocardial cell membrane, resulting in irreversible electroporation and causes myocardial cell contents leakage, destruction of intracellular homeostasis, cell death, and slight inflammatory response. PEF as non-thermal energy promotes the design and application of arrhythmia ablation catheter to enter a new stage. There are currently limited clinical studies that have proved the safety and effectieness of Farawave PEF catheter, PVAC GOLD PEF catheter, Lattice-tip Sphere-9 PEF and radiofrequency (RF) catheter used for atrial fibrillation ablation, but still need further discussion. The research of atrial fibrillation ablation with PEF is under study in China. In this paper, the design and application of PEF ablation for tachyarrhythmia are reviewed.
Atrial Fibrillation/surgery*
;
Catheter Ablation
;
Catheters
;
Humans
;
Pulmonary Veins/surgery*
;
Tachycardia
6.Impact factors of in-stent restenosis following successful stent implantation for acquired severe pulmonary vein stenosis post atrial fibrillation ablation.
Yan Jie LI ; Xin PAN ; Cheng WANG ; Lan MA ; Ben HE
Chinese Journal of Cardiology 2020;48(5):373-377
Objective: To investigate the influencing factors of in-stent restenosis (ISR) following successful stent implantation in patients with ablation-associated severe pulmonary vein stenosis (PVS) who undergo atrial fibrillation ablation. Methods: Data of patients who underwent pulmonary vein angiography to confirm PVS after radiofrequency ablation for atrial fibrillation (AF) and received pulmonary vein stenting at Shanghai Chest Hospital from March 2010 to December 2017 were retrospectively analysed. All patients were followed up for a long period of time (pulmonary vein contract-enhanced CT within 6 to 12 months after operation was performed, and pulmonary angiography was performed if CT indicated stenosis>50%). The incidence of ISR was recorded. According to angiography, the patients were divided into ISR group and non-ISR group. The clinical and intraoperative imaging characteristics and interventional data were compared between the two groups. Logistic regression was used to analyse the influencing factors of ISR. Results: A total of 47 patients ((47.1±12.2) years old) were enrolled in this study, including 28 males(59.6%). There were 19 cases in ISR group and 28 cases in non-ISR group. Compared with the non-ISR group, the ISR group received more pulmonary vein isolation ((2.8±0.9) vs. (1.8±1.3), P=0.02), and the interval between last ablation and stenting was longer ((19.4±9.6) vs. (13.0±12.4), P=0.03). The incidence of ISR in patients with stent diameter≤8 mm was significantly higher than those with stent diameter>8 mm (33.3%(20/60) vs. 8.1%(3/37), P<0.01). Logistic regression analysis found that the number of radiofrequency ablation>1 (OR=2.1, 95%CI 1.3-3.9, P=0.02), and the time from the last ablation to stent placement>12 months (OR=1.5, 95%CI 1.1-2.5, P=0.03), reference diameter of stenosed distal vessel (OR=0.7, 95%CI 0.5-0.9, P=0.04), post procedural minimal luminal diameter (OR=0.4, 95%CI 0.2-0.8, P=0.02) and stent diameter (OR=0.6, 95%CI 0.3-0.9, P=0.03) were independent factors of ISR. Conclusions: The greater number of radiofrequency ablations and the longer time from the last ablation to stent placement increase the risk of ISR. The larger reference diameter of the stenosed distal vessel, stent diameter and post procedural minimal luminal diameter are the protective factors of ISR.
Adult
;
Atrial Fibrillation
;
Catheter Ablation
;
China
;
Constriction, Pathologic
;
Coronary Restenosis
;
Female
;
Humans
;
Male
;
Middle Aged
;
Pulmonary Veins
;
Retrospective Studies
;
Stenosis, Pulmonary Vein
;
Stents
;
Treatment Outcome
8.Risk factors for atrial fibrillation recurrence after catheter ablation.
Cong WU ; Qian XU ; Ruizheng SHI ; Guogang ZHANG
Journal of Central South University(Medical Sciences) 2019;44(10):1196-1202
The advent of catheter ablation technology has changed the treatment strategy for atrial fibrillation, and the efficacy of catheter ablation is accurate with small surgical trauma. Catheter ablation treatment of atrial fibrillation is significantly better than pharmacologic therapy of anti-arrhythmia and rate control. However, the clinic data of catheter ablation of atrial fibrillation show that the recurrence rate is high. The risk factors for recurrence after catheter ablation include age, sex, body mass index, related primary disease, left atrial volume, pulmonary vein volume, gene, atrial fibrillation types, surgery and so on. Regulation of the above factors is crucial in improving the clinical efficacy and prognosis of catheter ablation of atrial fibrillation.
Anti-Arrhythmia Agents
;
Atrial Fibrillation
;
Catheter Ablation
;
Humans
;
Pulmonary Veins
;
Recurrence
;
Risk Factors
;
Treatment Outcome
9.Comparison of cryoballoon ablation for atrial fibrillation guided by real-time three-dimensional transesophageal echocardiography vs. contrast agent injection.
Yuan-Jun SUN ; Xiao-Meng YIN ; Tao CONG ; Lian-Jun GAO ; Dong CHANG ; Xian-Jie XIAO ; Qiao-Bing SUN ; Rong-Feng ZHANG ; Xiao-Hong YU ; Ying-Xue DONG ; Yan-Zong YANG ; Yun-Long XIA
Chinese Medical Journal 2019;132(3):285-293
BACKGROUND:
Pulmonary vein (PV) occlusion generally depends on repetitive contrast agent injection when cryoballoon ablation for atrial fibrillation (AF). The present study was to compare the effect of cryoballoon ablation for AF guided by transesophageal echocardiography (TEE) vs. contrast agent injection.
METHODS:
Eighty patients with paroxysmal AF (PAF) were enrolled in the study. About 40 patients underwent cryoballoon ablation without TEE (non-TEE group) and the other 40 underwent cryoballoon ablation with TEE for PV occlusion (TEE group). In the TEE group during the procedure, PVs were displayed in 3-dimensional images to guide the balloon to achieve PV occlusion. The patients were followed up at regularly scheduled visits every 2 months.
RESULTS:
No differences were identified between the groups in regard to the procedure time and cryoablation time for each PV. The fluoroscopy time (6.7 ± 4.2 min vs. 17.9 ± 5.9 min, P < 0.05) and the amount of contrast agent (3.0 ± 5.1 mL vs.18.1 ± 3.4 mL, P < 0.05) in the TEE group were both less than the non-TEE group. At a mean of 13.0 ± 3.3 mon follow-up, success rates were similar between the TEE group and non-TEE group (77.5% vs. 80.0%, P = 0.88).
CONCLUSIONS
Cryoballoon ablation with TEE for occlusion of the PV is both safe and effective. Less fluoroscopy time and a lower contrast agent load can be achieved with the help of TEE for PV occlusion during procedure.
Aged
;
Atrial Fibrillation
;
diagnostic imaging
;
surgery
;
Contrast Media
;
Cryosurgery
;
methods
;
Echocardiography, Three-Dimensional
;
methods
;
Echocardiography, Transesophageal
;
methods
;
Female
;
Humans
;
Male
;
Middle Aged
;
Pulmonary Veins
;
diagnostic imaging
;
surgery
;
Treatment Outcome

Result Analysis
Print
Save
E-mail