1.2024 American Academy of Orthopaedic Surgeons (AAOS) Clinical Practice Guideline: Management of Osteoarthritis of the Hip (summary) interpretation.
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(10):1325-1332
Hip osteoarthritis (OA) is a significant disease worldwide that causes functional impairment and reduced quality of life. With the aging of the population and the increasing prevalence of obesity, its disease burden is becoming increasingly heavy. In December 2023, the American Academy of Orthopaedic Surgeons (AAOS) released the updated Clinical Practice Guideline for the Management of Osteoarthritis of the Hip (summary). Based on evidence-based medicine, this guideline provides systematic recommendations for the diagnosis and treatment of hip OA. This article will comprehensively interpret the guideline, compare it with relevant domestic expert consensus in China, analyze the consistency and differences in disease management strategies between the two, and provide references for clinical practice.
Humans
;
Academies and Institutes
;
Arthroplasty, Replacement, Hip
;
China
;
Evidence-Based Medicine
;
Orthopedic Surgeons
;
Orthopedics
;
Osteoarthritis, Hip/surgery*
;
Quality of Life
;
United States
2.Perioperative management of direct-to-implant-based breast reconstruction in breast cancer patients and West China Hospital experiences.
Yu FENG ; Donglin ZHANG ; Faqing LIANG ; Guilin LUO ; Zhenggui DU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(10):1356-1362
OBJECTIVE:
To optimize the perioperative management experiences for breast cancer patients undergoing direct-to-implant-based breast reconstruction, and provide reference for clinical practice.
METHODS:
A comprehensive review of recent domestic and international literature was conducted to systematically summarize the key points of perioperative management for direct-to-implant-based breast reconstruction, including preoperative health education, intraoperative strategies, and postoperative management measures, along with an introduction to the clinical experiences of West China Hospital of Sichuan University.
RESULTS:
Standardized perioperative management can effectively reduce the incidence of complications and achieve excellent cosmetic outcomes and quality of life after operation. Preoperative management includes proactive health education to alleviate patients' anxiety and improve treatment compliance, as well as comprehensive assessment by surgeons of the patient's physical condition and reconstructive expectations to select the most appropriate implant. Intraoperative management consists of strict aseptic technique, minimizing implant exposure, preserving blood supply to the nipple-areola complex (e.g., by using minimally invasive techniques or indocyanine green angiography, etc), and meticulous hemostasis. Postoperative management encompasses multimodal analgesia, individualized drain management (such as early removal or retaining a small amount of fluid to optimize contour), infection prevention and control (including topical and systemic antibiotics, ultrasound-guided minimally invasive drainage), guidance on rehabilitation exercises (early activity restriction followed by gradual recovery), and regular follow-up to evaluate aesthetic results and monitor for complications.
CONCLUSION
Establishing a standardized, multidisciplinary perioperative management framework markedly enhances surgical safety and patient satisfaction, thereby providing a replicable benchmark for direct-to-implant-based breast reconstruction across diverse clinical settings.
Humans
;
Female
;
Breast Neoplasms/surgery*
;
China
;
Perioperative Care/methods*
;
Breast Implants
;
Mammaplasty/methods*
;
Breast Implantation/methods*
;
Postoperative Complications/prevention & control*
;
Quality of Life
;
Mastectomy
3.Identification of high-risk preoperative blood indicators and baseline characteristics for multiple postoperative complications in rheumatoid arthritis patients undergoing total knee arthroplasty: a multi-machine learning feature contribution analysis.
Kejia ZHU ; Zhiyang HUANG ; Biao WANG ; Hang LI ; Yuangang WU ; Bin SHEN ; Yong NIE
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1532-1542
OBJECTIVE:
To explore, identify, and develop novel blood-based indicators using machine learning algorithms for accurate preoperative assessment and effective prediction of postoperative complication risks in patients with rheumatoid arthritis (RA) undergoing total knee arthroplasty (TKA).
METHODS:
A retrospective cohort study was conducted including RA patients who underwent unilateral TKA between January 2019 and December 2024. Inpatient and 30-day postoperative outpatient follow-up data were collected. Six machine learning algorithms, including decision tree, random forest, logistic regression, support vector machine, extreme gradient boosting, and light gradient boosting machine, were used to construct predictive models. Model performance was evaluated using the area under the receiver operating characteristic curve (AUC), F1-score, accuracy, precision, and recall. SHapley Additive exPlanations (SHAP) values were employed to interpret and rank the importance of individual variables.
RESULTS:
According to the inclusion criteria, a total of 1 548 patients were enrolled. Ultimately, 18 preoperative indicators were identified as effective predictive features, and 8 postoperative complications were defined as prediction labels for inclusion in the study. Within 30 days after surgery, 453 patients (29.2%) developed one or more complications. Considering overall accuracy, precision, recall, and F1-score, the random forest model [AUC=0.930, 95% CI (0.910, 0.950)] and the extreme gradient boosting model [AUC=0.909, 95% CI (0.880, 0.938)] demonstrated the best predictive performance. SHAP analysis revealed that anti-cyclic citrullinated peptide antibody, C-reactive protein, rheumatoid factor, interleukin-6, body mass index, age, and smoking status made significant contributions to the overall prediction of postoperative complications.
CONCLUSION
Machine learning-based models enable accurate prediction of postoperative complication risks among RA patients undergoing TKA. Inflammatory and immune-related blood biomarkers, such as anti-cyclic citrullinated peptide antibody, C-reactive protein, and rheumatoid factor, interleukin-6, play key predictive roles, highlighting their potential value in perioperative risk stratification and individualized management.
Humans
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Arthritis, Rheumatoid/blood*
;
Machine Learning
;
Postoperative Complications/blood*
;
Female
;
Male
;
Retrospective Studies
;
Middle Aged
;
Aged
;
Risk Factors
;
Preoperative Period
;
C-Reactive Protein/analysis*
;
Risk Assessment
4.Early follow-up study on three-dimensional-printed customized porous acetabular components for reconstructing extensive acetabular bone defects in primary total hip arthroplasty.
Shangkun TANG ; Zhuangzhuang LI ; Xin HU ; Linyun TAN ; Hao WANG ; Yitian WANG ; Minxun LU ; Fan TANG ; Yi LUO ; Yong ZHOU ; Chongqi TU ; Li MIN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1543-1550
OBJECTIVE:
To evaluate the feasibility and short-term effectiveness of three-dimensional (3D)-printed customized porous acetabular components for reconstruction of extensive acetabular bone defects during primary total hip arthroplasty (THA).
METHODS:
The clinical data of 8 patients with extensive acetabular bone defects, who were treated with 3D-printed individualized porous acetabular components between July 2018 and January 2022, were retrospectively analyzed. The cohort comprised 4 males and 4 females with an average age of 48 years ranging from 34 to 56 years. Acetabular bone defects were classified as Paprosky type ⅢA in 3 cases and type ⅢB in 5 cases. The causes of acetabular destruction were hip tuberculosis (5 cases), pigmented villonodular synovitis (2 cases), and syphilitic arthritis (1 case). Visual analogue scale (VAS) score and Harris hip score (HHS) were used to evaluate the pain relief and hip function before and after operation. Reconstruction outcomes were further assessed by imaging results [X-ray film and Tomosynthesis Shimadzumetal artefact reduction technology (T-SMART)], and the mechanical properties were evaluated by finite element analysis.
RESULTS:
The operation time ranged from 174 to 195 minutes (mean, 187 minutes), and intraoperative blood loss ranged from 390 to 530 mL (mean, 465 mL). All 8 patients were follow-up 26-74 months (mean, 44 months). Among the 5 patients with tuberculosis, none experienced postoperative recurrence. At last follow-up, the VAS score was 0.3±0.5 and the HHS score was 87.9±3.7, both significantly improved compared to preoperative values ( t=25.170, P<0.001; t=-28.322, P<0.001). X-ray films at 2 years after operation demonstrated satisfactory matching between the 3D-printed customized acetabular component and the acetabulum. The postoperative center of rotation of the operated hip was shifted by (2.1±0.5) mm horizontally and (2.0±0.7) mm vertically relative to the contralateral side, with both offsets showing significant differences compared to preoperative values ( t=24.700, P<0.001; t=55.230, P<0.001). T-SMART imaging showed satisfactory osseointegration at the implant-host bone interface. No complications such as aseptic loosening or screw breakage was observed during follow-up. Finite element analysis showed that the acetabular component had good mechanical properties.
CONCLUSION
The application of 3D-printed individualized porous acetabular components in the reconstruction of extensive acetabular bone defects demonstrated precise anatomical reconstruction, stable mechanical support, and good functional performance in short-term follow-up, offering a potential alternative for acetabular defect reconstruction in primary THA.
Humans
;
Middle Aged
;
Male
;
Female
;
Printing, Three-Dimensional
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Acetabulum/diagnostic imaging*
;
Adult
;
Follow-Up Studies
;
Retrospective Studies
;
Hip Prosthesis
;
Prosthesis Design
;
Porosity
;
Treatment Outcome
;
Plastic Surgery Procedures/methods*
5.Preoperative diagnostic efficacy of novel blood markers white blood cell ratio and fibrinogen levels in periprosthetic joint infection.
Geng-Yao ZHU ; Chao MA ; Guang-Wang LIU ; Jia-Zheng MAN
China Journal of Orthopaedics and Traumatology 2025;38(1):55-60
OBJECTIVE:
To investigate the clinical utility of novel of new hematological markers in the preoperative diagnosis of periprosthetic joint infection (PJI).
METHODS:
A retrospective analysis was conducted on a total of 149 patients who underwent revision of total hip arthroplasty (THA) or total knee arthroplasty (TKA) at a single center between January 2016 and June 2022, including 63 males and 86 females, aged from 47 to 93 years old with an average of (69.5±11.8) years old. Of them, 46 were diagnosed as PJI(PJI group), including 22 males and 24 females. The mean age was (71.3±12.5) years old. The body mass index (BMI) was (26.4±3.1) kg·m-2. And 103 patients were diagnosed as aseptic prosthesis loosening (aseptic group), including 41 males and 62 females. The mean age was (68.7±11.4) years old. The BMI was (25.8±3.5) kg·m-2. Preoperatively analyzed clinical parameters included C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), albumin, globulin, albumin-to-globulin ratio (AGR), plasma D-dimer, and plasma fibrinogen. The receiver operating characteristic curve (ROC), sensitivity, and specificity analysis were employed to compare the diagnostic value of each blood marker in preoperative PJI diagnosis.
RESULTS:
In the PJI group, the levels of CRP were 16.6 (7.6, 4.5) mg·L-1, ESR was 17.0 (12.8, 35.5) mm·h-1, plasma D-dimer was 1.0 (0.5, 3.1) μg·L-1, and plasma fibrinogen was 4.2 (3.2, 3.1) mg·L-1;all of which were higher compared to the aseptic group with CRP at 4.2 (2.6, 7.8) mg·L-1, ESR at 12.0(8.0, 20.0 )mm·h-l, D-dimer at 0.4(0.2, 0.7)μg·L-1, and fibrinogen at 2.8(2.4, 3.3 ) g·L-1(P<0.05). However, the albumin level of 35.3 (32.3, 37.5) g·L-1 and the WBC ratio of 1.0(0.9, 1.1) in the PJI group were significantly lower compared to the aseptic group with levels of 39.8 (36.1, 41.8) g·L-1 and 1.4 (1.3, 1.5), respectively (P<0.05). Only the area under the curve (AUC) of AGR and plasma fibrinogen were greater than 0.8. The optimal predictive cut-1off, AUC, sensitivity and specificity were 3.4 g·L-1, 0.820, 69.57% and 84.47% for plasma fibrinogen; 1.18, 0.813, 82.61% and 78.64% for AGR, respectively.
CONCLUSION
AGR and plasma fibrinogen are promising blood markers for improving the diagnosis of PJI.
Humans
;
Female
;
Fibrinogen/metabolism*
;
Male
;
Middle Aged
;
Aged
;
Prosthesis-Related Infections/blood*
;
Retrospective Studies
;
Biomarkers/blood*
;
Aged, 80 and over
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Leukocyte Count
6.Early clinical outcomes of 3D-printed individualised customised prostheses in hip revision combined severe bone defect.
Hong-Ping WANG ; Ming-You WANG ; Xiao-Qin YANG ; Zhuo-Dong TANG ; Xun-Zhou SONG ; Yu-Ping LAN
China Journal of Orthopaedics and Traumatology 2025;38(2):163-169
OBJECTIVE:
To explore the early clinical outcomes of 3D printed individualised customised prostheses for in hip revision in patients with combined severe bone defects.
METHODS:
Twenty-two patients from January 2021 to May 2023 underwent hip revision using 3D printed personalised customised prostheses were retrospective analyzed, including 10 males and 12 females, age 28 to 78 with a mean of (58.9±12.8) years old. All of patients were combined with severe bone defects (Parprosky type Ⅲ). Among of them, 9 patients had periprosthetic infections and 13 patients had aseptic prosthesis loosening. All patients were treated with a 3D printed personalised prosthesis protocol, patients with the periprosthetic infection received a second stage revision after infection control. The operation time, preoperative waiting time, intraoperative and postoperative complications were recorded, and the clinical efficacy were evaluated at the final follow-up using the visual analogue scale (VAS) for pain, the Harris hip score.
RESULTS:
One patient was lost to follow-up and the remaining 21 patients were followed up for 10 to 15 with a mean of (12.91±1.44) months after surgery. All patients completed surgery as planned, with an operative time of 135 to 390 with a mean of (165.4±39.3) minutes and a preoperative waiting time of 7 to 16 with a mean of (10.5±3.3) days. Regarding patient complications:one patient had a severe intraoperative periprosthetic femoral fracture due to the combination of severe osteoporosis; one patient had an intraoperative greater trochanteric femur fracture. At the latest follow-up, all patients had good position of the custom-made prosthesis and no loosening of the prosthesis;all patients had good wound healing and no local redness or swelling. The total Harris score at the final follow-up (85.86±7.04) was significantly improved compared to the preoperative (44.86±2.36), P<0.001. The VAS at the last follow-up (2.19±0.87) was significantly improved compared with preoperative (7.41±0.96), P<0.001.
CONCLUSION
The clinical efficacy of 3D-printed personalised customised prosthesis in combined severe bone defect hip revision is satisfactory, but due to the increased preoperative waiting time of the patients and certain risks, certain indications should be mastered when applying in the clinic.
Humans
;
Male
;
Female
;
Printing, Three-Dimensional
;
Middle Aged
;
Aged
;
Adult
;
Retrospective Studies
;
Hip Prosthesis
;
Arthroplasty, Replacement, Hip
;
Reoperation
;
Prosthesis Design
;
Treatment Outcome
7.Clinical features and surgical treatment strategies of hip arthroplasty for unhealed old femoral intertrochanteric fractures.
Qing XIA ; Chuan-Wen LIU ; Yu-Cheng XIA ; Hui-Yang WANG ; Jin-Quan GUO
China Journal of Orthopaedics and Traumatology 2025;38(2):188-194
OBJECTIVE:
To explore the surgical method and clinical efficacy of hip arthroplasty in the treatment of old non-union femoral intertrochanteric fractures.
METHODS:
Fifteen unoperated patients suffering from old non-union femoral intertrochanteric fractures from Feburary 2013 to Feburary 2023 were treated with hip arthroplasty including 9 males and 6 females, aged 71 to 82 years old. Eleven cases detected deep venous thrombosis(DVT), 9 cases received lower vena cava filter implantation. The operation time, intraoperative blood loss, intraoperative and postoperative blood transfusion, postoperative hemoglobin content, procedure-related complications, and the range of motion of hip flexion, abduction motion were recorded. The degree of hip pain was evaluated using a visual analogue scale(VAS). The hip Harris scores were used to evaluated the clinical efficacy.
RESULTS:
All patients were followed up for 3 to 12 months. The intraoperative blood loss was 200 to 400 ml, intraoperative blood transfusion was 0 to 400 ml, and the operation time was 40 to 90 min. All 15 patients had different degrees of anemia after surgery, the 3 days postoperative hemoglobin was 72 to 97 g·L-1, and the postoperative transfusion volume was 0 to 400 ml. All patients had no periprosthetic infection, poor incision healing, lower limb deep vein thrombosis, and cerebral infarction. One case occurred in the early postoperative period, which disappeared from 4 to 5 days after operation, and there was no further revision at the last follow-up. The VAS was 6 to 7 points before operation and 2 to 4 points at latest follow-up;the hip Harris score was 2 to 13 points before operation and 73 to 84 points at latest follow-up.
CONCLUSION
The unoperated patients of old non-union femoral intertrochanteric fractures had significant clinical and imaging characteristics. Hip arthroplasty combined with or without femoral calcar reconstruction in the treatment of old non-union femoral intertrochanteric fractures had the advantages of relatively simple manipulation, rigid fixation, relatively safe operation, and relatively exact efficacy.
Humans
;
Male
;
Female
;
Aged
;
Hip Fractures/physiopathology*
;
Aged, 80 and over
;
Arthroplasty, Replacement, Hip/methods*
8.Reverse shoulder replacement for the treatment of 18 patients with unrepairable rotator cuff injury.
Liang WANG ; Ru-Qing YE ; Meng WANG ; Min-Jian ZHANG ; Xu TANG
China Journal of Orthopaedics and Traumatology 2025;38(3):258-264
OBJECTIVE:
To explore clinical effect of reverse shoulder replacement in treating giant irreparable rotator cuff tear complicated with glenohumeral arthritis.
METHODS:
A retrospective analysis was performed on 18 patients (18 shoulders) with glenohumeral arthritis combined with large irreparable rotator cuff tear admitted from April 2020 to April 2022, including 10 males and 8 females, aged from 60 to 78 years old;7 patients on the left side, 11 patients on the right side;the course of disease ranged from 6 to 21 months;7 patients with grade 3 and 11 patients with grade 4 according to Goutallier grading;8 patients with grade 4b and 10 patients with grade 5 according to Hamada grading. Shoulder joint motion, visual analogue scale (VAS), University of California at Los Angeles (UCLA) score and Constant-Murley shoulder joint function score and complications were compared at the latest follow-up.
RESULTS:
Eighteen patients were followed up for 24 to 48 months. At the latest follow-up, shoulder joint flexion ranged from 120° to 145°, abduction ranged from 100° to 130°, and rotation ranged from 45° to 60°. VAS ranged from 1 to 3;Constant-Murley score ranged from 80 to 95;and UCLA scores ranged from 27 to 35, and 6 patients obtained excellent result, 11 good and 1 average. Dislocation of shoulder joint occurred in 1 patient at 3 months after operation, but no dislocation occurred after manual reduction. The incision surface infection occurred in 1 patient at 1 week after operation, and the incision healed after anti-infection and cleaning. The other patients did not have complications such as dislocation, infection, prosthesis loosening and peripheral fracture.
CONCLUSION
Reverse shoulder replacement for the treatment of huge irreparable rotator cuff injury combined with glenohumeral arthritis disease, the clinical effect is good, could significantly improve shoulder joint function and improve quality of life, but still need to strengthen the prevention and treatment of postoperative complications such as dislocation and infection.
Humans
;
Male
;
Female
;
Middle Aged
;
Rotator Cuff Injuries/physiopathology*
;
Aged
;
Retrospective Studies
;
Arthroplasty, Replacement, Shoulder/methods*
;
Range of Motion, Articular
;
Shoulder Joint/physiopathology*
9.Clinical study on the efficacy of unicompartmental knee arthroplasty in elderly patients with medial osteoarthritis and anterior cruciate ligament deficiency.
Hai-Song LIANG ; Dong SHENG ; Xiao-Su HUI ; Xin-Wen BAI ; Yu DENG ; Cong-Ke SHU ; Fa-Song XIANG
China Journal of Orthopaedics and Traumatology 2025;38(4):336-342
OBJECTIVE:
To investigate the short-and med-term clinical efficacy of unicompartmental knee arthroplasty(UKA)for the treatment of medial knee osteoarthritis (OA) in elderly patients with anterior cruciate ligament deficiency(ACLD).
METHODS:
A retrospective analysis was conducted on 31 patients aged over 75 years old with primary medial knee OA and ACLD who underwent UKA between January 2018 and December 2022. The cohort included 12 males and 19 females, aged from 75 to 91 years with an average age of (79.56±4.54) years, with 13 left knee, 16 right knee, and 2 bilateral knees. Clinical outcomes were assessed preoperatively and at final follow-up using the visual analogue scale (VAS), Hospital for Special Surgery(HSS) score, range of motion (ROM), hip-knee-ankle angle (HKA), and tibial component posterior slope angle (TCPSA). Complications such as infection, prosthesis wear, prosthesis loosening, and dislocation were also recorded.
RESULTS:
All 31 patients were followed up from 12 to 63 months with an average of (28.34±10.56) months. The average postoperative TCPSA was (4.83±1.31)° ranged from 2.5° to 6.8°. At the final follow-up, there was significant improvement in VAS (3.24±0.53) vs. (6.59±0.69), HSS score (85.19±4.45) vs. (64.38±5.94), ROM (118.83±5.38)° vs. (98.85±4.08)°, and HKA (176.83±5.16)° vs. (169.57±6.28)° compared to preoperative values (P<0.05). No cases of infection, prosthesis loosening, or dislocation were reported.
CONCLUSION
UKA provides favorable short-and mid-term outcomes for elderly patients with medial knee OA and ACLD . However, long-term clinical efficacy needs further investigation through extended follow-up.
Humans
;
Male
;
Female
;
Arthroplasty, Replacement, Knee/methods*
;
Aged
;
Osteoarthritis, Knee/physiopathology*
;
Retrospective Studies
;
Aged, 80 and over
;
Range of Motion, Articular
;
Anterior Cruciate Ligament Injuries/surgery*
10.Early impact of robot-assisted total knee arthroplasty on the treatment of varus knee arthritis.
Xin YANG ; Qing-Hao CHENG ; Fu-Qiang ZHANG ; Hua FAN ; Fu-Kang ZHANG ; Zhuang-Zhuang ZHANG ; Yong-Ze YANG ; An-Ren ZHANG ; Hong-Zhang GUO
China Journal of Orthopaedics and Traumatology 2025;38(4):343-351
OBJECTIVE:
To investigate the clinical efficacy and advantages of robot-assisted total knee arthroplasty (TKA) in patients with varus knee osteoarthritis.
METHODS:
Between October 2022 and June 2023, a total of 59 patients with severe knee osteoarthritis resulting in varus were treated with total knee arthroplasty, aged from 59 to 81 years with an average (70.90±4.63) years, including 19 mals and 40 females. The patients were divided into two groups based on the surgical method used:28 patients in the robot group and 31 patients in the traditional group. The robot group consisted of 8 males and 20 femalse patients, with an average age of (70.54±4.80) years and an average disease duration of (14.89±8.72) months. The traditional group consisted of 11 males and 20 females patients, with an average age of (71.39±4.5) years and an average disease duration of (12.32±6.73) months. The operative duration, amount of bleeding during the operation, postoperative activity time after the operation, hip-knee-ankle angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and complications were compared between the two groups before and after the operation. Lateral tibia component (LTC), frontal tibia component (FTC), frontal femoral component (FFC) and lateral femoral component (LFC) were measured 6 months after operation Additionally, the degree of knee joint motility, American Knee Society score (KSS), and visual analogue scale(VAS) were compared before and after the operation.
RESULTS:
All patients had gradeⅠwound healing without any complications, and all patients were followed up for 6 to 8 months, with an average of (6.5±1.5) months. There were no significant differences preoperative imaging evaluation indexes (including HKA, LDFA, and MPTA), preoperative knee mobility, preoperative VAS, and preoperative KSS between the two groups (P>0.05). Comparing the operation time (109.11±7.16) min vs. (83.90±7.85) min, length of the incision (16.60±2.33) cm vs. (14.47±1.41) cm, intraoperative bleeding (106.93±6.15) ml vs. (147.97±7.62) ml, postoperative activity time (17.86±1.84) h vs. (21.77±2.68) h, between the two groups showed statistically significant differences (P<0.05). There were significant differences in FFC (88.96±0.84)° vs. (87.93±1.09)° and LFC (88.57±1.10)° vs. (87.16±1.2)° between the two groups at 6 months after operation (P<0.05). The robotic group 1, 3, 6 months after KSS (75.96±3.96), (81.53±3.78), (84.50±3.29) scores, VAS (3.68±0.67), (2.43±0.79), (0.54±0.64), knee joint mobility (113.32±4.72) °, (123.93±3.99) °, (135.36±2.34) °;Traditional group KSS (73.77±4.18), (76.48±3.60), (80.19±3.28) scores, VAS (4.16±1.04), (3.03±0.75), (1.42±0.76) scores, knee joint mobility (109.19±6.95) °, (119.94±6.08) °, (134.48±2.14) °. Compared to before surgery, both groups showed significant improvement in KSS, VAS and knee mobility during the three follow-up visits (P<0.001). Additionally, postoperative HKA (180.39±1.95)° vs. (178.52±2.23)°, LDFA (89.67±0.63) ° vs. (89.63±0.63)°, and MPTA (89.44±0.55)° vs. (89.29±0.60)° were significantly improved in both groups compared to before surgery (P<0.001). The robotic group had higher KSS than the traditional group at 1, 3, and 6 months after surgery (P<0.05). The robotic group also had lower VAS than the traditional group at 1, 3, and 6 months after surgery (P<0.05). Furthermore, knee mobility was higher in the robotic group than those in the traditional group at 1 and 6 months after surgery (P<0.05), but there was no significant difference between the two groups at 6 months after surgery.
CONCLUSION
Robot-assisted total knee arthroplasty is a safe and effective method for total knee replacement. The use of robotics can improve the limb axis and prosthesis alignment for patients with preoperative varus deformity, resulting in better clinical and imaging outcomes compared to the conventional group.
Humans
;
Female
;
Male
;
Arthroplasty, Replacement, Knee/methods*
;
Aged
;
Middle Aged
;
Osteoarthritis, Knee/physiopathology*
;
Aged, 80 and over
;
Robotic Surgical Procedures/methods*

Result Analysis
Print
Save
E-mail