1.Impact of elevated arterial blood pressure on bioprosthetic valve calcification and failure after transcatheter aortic valve replacement.
Wenjing SHENG ; Qifeng ZHU ; Hanyi DAI ; Dao ZHOU ; Xianbao LIU
Journal of Zhejiang University. Medical sciences 2025;54(2):154-160
Transcatheter aortic valve replacement (TAVR) has emerged as the standard treatment for severe aortic stenosis, demonstrating comparable efficacy to traditional surgery in low and intermediate-risk patients. However, the bioprosthetic valves utilized in TAVR have a limited lifespan, and bioprosthetic valve failure, including calcification, rupture or infection may develop, leading to poor clinical outcomes. Elevated blood pressure has been identified as a key factor in aortic valve calcification, and its role in bioprosthetic valve failure is gaining increasing attention. Hypertension may accelerate the calcification process and exacerbate valve failure due to increased mechanical stress on the valve, activation of the renin-angiotensin system, and enhanced thrombus formation. Furthermore, elevated blood pressure interacts with prosthesis mismatch and paravalvular leak, jointly affecting valve durability. This review explores the impact of elevated blood pressure on bioprosthetic valve calcification and failure after TAVR, and emphasizes the importance of blood pressure control, optimized preoperative assessment, and appropriate valve selection in reducing valve failures.
Humans
;
Transcatheter Aortic Valve Replacement/adverse effects*
;
Calcinosis/etiology*
;
Bioprosthesis
;
Heart Valve Prosthesis/adverse effects*
;
Prosthesis Failure
;
Aortic Valve Stenosis/surgery*
;
Aortic Valve/surgery*
;
Hypertension/physiopathology*
2.Research progress in Cup-cage reconstruction for patients with chronic pelvic discontinuity after total hip arthroplasty.
Xingxiao PU ; Qiuru WANG ; Qianhao LI ; Lijun CAI ; Guangtao HAN ; Pengde KANG
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(12):1530-1536
OBJECTIVE:
To summarize research progress on application of Cup-cage reconstruction in revision of chronic pelvic discontinuity (CPD) in patients undergoing total hip arthroplasty (THA).
METHODS:
Relevant literature at home and abroad in recent years was reviewed to summarize the principles of the Cup-cage reconstruction, preoperative patient assessment, intraoperative skills, clinical and radiological effectiveness, limitations, and postoperative complications.
RESULTS:
For the treatment of CPD, the Cup-cage reconstruction achieved long-term acetabular cup bone ingrowth, CPD healing, and biologic fixation of the prosthesis by restoring pelvic continuity. Preoperative evaluation of the surgical site and general condition is necessary. The main intraoperative objectives are to reconstruct pelvic continuity, restore the center of rotation of the hip, and avoid neurovascular injury. Current studies have demonstrated significant clinical and radiological effectiveness as well as acceptable prosthesis survival rates after operation. Nevertheless, there is a lack of evidence regarding the staging of CPD, the optimal surgical approach and internal fixation, and the factors influencing postoperative prosthesis survival remain undefined.
CONCLUSION
Cup-cage reconstruction can be an effective treatment for CPD after THA, but there is still a need to explore CPD staging, Cup-cage approach and internal fixation, and influencing factors on prosthesis survival.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Hip Prosthesis
;
Acetabulum/surgery*
;
Reoperation
;
Plastic Surgery Procedures/methods*
;
Prosthesis Failure
;
Postoperative Complications/etiology*
;
Hip Joint/surgery*
3.Comparison on the efficacy of Chinese-made novel-designed mechanical-locked and elastic self-locked transcatheter edge-to-edge repair system in the treatment of patients with functional mitral regurgitation.
Da ZHU ; Shou Zheng WANG ; Zhi Ling LUO ; Jia Hua PAN ; Ke YANG ; Chun Mei XIE ; Yong Yan TANG ; Hong Bo YANG ; Mi Er MA ; Jian Bin GAO ; Xiang Bin PAN
Chinese Journal of Cardiology 2023;51(8):832-837
Objective: To evaluate and compare the short-term efficacy of domestic mechanical-locked (Clip2Edge) and elastic self-locked (ValveClip) transcranial mitral valve edge-to-edge interventional repair (TEER) devices in the treatment of functional mitral regurgitant valves. Methods: In this retrospective non-randomized comparative study, patients underwent TEER procedure in Fuwai Yunnan Cardiovascular Disease Hospital from May 2022 to April 2023 for heart failure combined with moderate to severe or severe functional mitral valve were divided into Clip2Edge and ValveClip groups based on the TEER system used. Baseline, perioperative, and postoperative 30 d follow-up data were collected and compared between the two groups. The primary outcome was the success rate on the 30 d post operation, while secondary outcomes included immediate postoperative technical success rate and the incidence of all-cause mortality on the 30 d post operation, readmission rate of acute heart failure, cerebral infarction, severe bleeding, and other serious adverse events rates. Results: A total of 60 patients were enrolled, 34 patients were in the Clip2Edge group and 26 in the ValveClip group, mean age was (63.8±9.3) years, and 24 patients (40%) were female. There were no significant differences in baseline data of age, cardiac function, comorbidities, mitral regurgitation 4+(19(73%) vs. 29(85%)), the end-diastolic volume of left ventricle ((220.8±91.2) ml vs. (210.8±71.7) ml) between the two groups (all P>0.05). The technical success rate immediately after the procedure was 100%. There were no readmission of acute heart failure, death, cerebral infarction, severe bleeding, and other serious adverse events up to the 30 d follow-up. Device success rate was similar between the ValveClip group (24 cases (100%)) and the Clip2Edge group (27 cases (96%)) (P>0.05). Conclusion: Both types of novel domestic TEER devices are safe and feasible in treating patients with functional mitral regurgitation.
Humans
;
Female
;
Middle Aged
;
Aged
;
Male
;
Mitral Valve Insufficiency/etiology*
;
Retrospective Studies
;
East Asian People
;
Heart Valve Prosthesis Implantation
;
Treatment Outcome
;
China
;
Heart Failure/etiology*
;
Cardiac Catheterization
4.Comparison on the efficacy of Chinese-made novel-designed mechanical-locked and elastic self-locked transcatheter edge-to-edge repair system in the treatment of patients with functional mitral regurgitation.
Da ZHU ; Shou Zheng WANG ; Zhi Ling LUO ; Jia Hua PAN ; Ke YANG ; Chun Mei XIE ; Yong Yan TANG ; Hong Bo YANG ; Mi Er MA ; Jian Bin GAO ; Xiang Bin PAN
Chinese Journal of Cardiology 2023;51(8):832-837
Objective: To evaluate and compare the short-term efficacy of domestic mechanical-locked (Clip2Edge) and elastic self-locked (ValveClip) transcranial mitral valve edge-to-edge interventional repair (TEER) devices in the treatment of functional mitral regurgitant valves. Methods: In this retrospective non-randomized comparative study, patients underwent TEER procedure in Fuwai Yunnan Cardiovascular Disease Hospital from May 2022 to April 2023 for heart failure combined with moderate to severe or severe functional mitral valve were divided into Clip2Edge and ValveClip groups based on the TEER system used. Baseline, perioperative, and postoperative 30 d follow-up data were collected and compared between the two groups. The primary outcome was the success rate on the 30 d post operation, while secondary outcomes included immediate postoperative technical success rate and the incidence of all-cause mortality on the 30 d post operation, readmission rate of acute heart failure, cerebral infarction, severe bleeding, and other serious adverse events rates. Results: A total of 60 patients were enrolled, 34 patients were in the Clip2Edge group and 26 in the ValveClip group, mean age was (63.8±9.3) years, and 24 patients (40%) were female. There were no significant differences in baseline data of age, cardiac function, comorbidities, mitral regurgitation 4+(19(73%) vs. 29(85%)), the end-diastolic volume of left ventricle ((220.8±91.2) ml vs. (210.8±71.7) ml) between the two groups (all P>0.05). The technical success rate immediately after the procedure was 100%. There were no readmission of acute heart failure, death, cerebral infarction, severe bleeding, and other serious adverse events up to the 30 d follow-up. Device success rate was similar between the ValveClip group (24 cases (100%)) and the Clip2Edge group (27 cases (96%)) (P>0.05). Conclusion: Both types of novel domestic TEER devices are safe and feasible in treating patients with functional mitral regurgitation.
Humans
;
Female
;
Middle Aged
;
Aged
;
Male
;
Mitral Valve Insufficiency/etiology*
;
Retrospective Studies
;
East Asian People
;
Heart Valve Prosthesis Implantation
;
Treatment Outcome
;
China
;
Heart Failure/etiology*
;
Cardiac Catheterization
5.Technical complications rates and plaque control of fixed dental prostheses in patients treated for periodontal disease.
Yesi XIE ; Huanxin MENG ; Jie HAN ; Shaoxia PAN ; Li ZHANG ; Dong SHI
Chinese Journal of Stomatology 2016;51(2):69-75
OBJECTIVETo compare the incidence of technical complications of implant-supported fixed dental prostheses in Chinese patients with a history of moderate or severe periodontitis and periodontally healthy patients(PHP) and analyze the effects of interproximal papillae patterns on food impaction and efficacy of plaque control.
METHODSA total of 103 partially edentulous patients treated with implant-supported fixed dental prostheses between December 2009 and December 2012 for a minimum 1-year follow-up period were recruited from Department of Periodontology, Peking University, School and Hospital of Stomatology. Based on the initial periodontal examination, the participants were divided into three groups: 30 PHP, 36 moderate periodontally compromised patients(mPCP) and 37 severe periodontally compromised patients(sPCP). Implant survival/loss, technical complications, plaque index, papilla index, food impaction and degree of proximal contact tightness of each patient were assessed around the implants at follow-up. According to the implant papilla index, the implants were divided into two groups: the "filling" group with the mesial and distal aspects with papilla index=3 and the "no filling" group with at least one aspect with papilla index<3. Data on implant survival, technical complications were analyzed. Comparisons of the incidence of technical complications were performed between the patients with different periodontal conditions with chi-square or Fisher's exact test. The influences of the interproximal papillae loss on food impaction and efficacy of plaque control were estimated with chi-square and Mann-Whitney U tests.
RESULTSThe total implant survival rate was 100%(162/162) for all three groups. Technical complications were as following: veneer fractures(1.9%, 3/162), abutment screw loosening(1.9%, 3/162), prosthetic screw loosening(3.1%, 5/162) and decementation(3.1%, 5/162) in all subjects. No implant/screw fracture was noted. The incidence of technical complications in sPCP, mPCP and PHP did not yield statistically significant differences(P>0.05). The proportion of the implant with the mesial and distal papilla index=3 in the sPCP was less than that in the PHP and mPCP. The interproximal papillae loss did not appear to affect the food impaction and the plaque index in all three groups(P>0.05). However, for the PHP, the accumulation of plaque at buccal aspect was more in the "no filling" group compared with the "filling" group (implant plaque index[M(Q)]: 1[1] vs 0[0]), and for the sPCP, the accumulation of plaque at lingual aspect was more in the "filling" group compared with the "no filling" group(implant plaque index[M(Q)]: 1[1] vs 0[1], (P<0.05).
CONCLUSIONSThe patients with a history of severe periodontitis did not exhibit more technical problems compared with the periodontally healthy patients. The interproximal papillae loss did not show a negative impact on the plaque control and food impaction. However, for the sPCP, changing the morphology and the position of the interproximal contact point to reduce the interdental black triangle may lead to accumulation of plaque at lingual aspect. More attention should be placed on the morphology design of prosthesis, but not the papillae filling up the interproximal space.
Beijing ; Dental Abutments ; Dental Implants ; Dental Plaque ; diagnosis ; etiology ; prevention & control ; Dental Plaque Index ; Dental Prosthesis, Implant-Supported ; adverse effects ; classification ; statistics & numerical data ; Dental Restoration Failure ; statistics & numerical data ; Follow-Up Studies ; Food ; Gingiva ; Humans ; Jaw, Edentulous, Partially ; rehabilitation ; Periodontal Diseases ; classification ; therapy
6.Optic Fracture of the Preloaded Intraocular Lens during Insertion.
Korean Journal of Ophthalmology 2016;30(1):79-80
No abstract available.
Aged
;
Device Removal
;
Humans
;
*Intraoperative Complications
;
*Lens Implantation, Intraocular
;
*Lenses, Intraocular
;
Male
;
*Phacoemulsification
;
Prosthesis Failure/*etiology
;
Reoperation
7.The Result of Revision Total Hip Arthroplasty in Patients with Metallosis Following a Catastrophic Failure of a Polyethylene Liner.
Hong Suk KWAK ; Jeong Joon YOO ; Young Kyun LEE ; Kyung Hoi KOO ; Kang Sup YOON ; Hee Joong KIM
Clinics in Orthopedic Surgery 2015;7(1):46-53
BACKGROUND: Wear cannot be completely prevented after total hip arthroplasty. If severe polyethylene (PE) liner wear develops, the so-called catastrophic failure occurs and metallosis develops. We postulated that longevity of the new implant may be affected after revision surgery for metallosis following a catastrophic failure of a PE liner due to the substantial amount of PE wear particles and infiltration of the metal particles in this catastrophic condition. METHODS: Twenty-three hips of 23 patients were identified because they showed metallosis during revision total hip arthroplasties performed in Seoul National University Hospital between January 1996 and August 2004. They were followed for at least 6.5 years after the index revision total hip arthroplasty. The clinical and radiological results of revision total hip arthroplasties in these patients were evaluated. RESULTS: The median Harris hip score increased from 60 points before revision total hip arthroplasties to 90 points at the final follow-up. Osteolysis was detected at an average of 9.3 years after revision total hip arthroplasties in 13 hips and acetabular cup loosening at average 9.8 years after revision total hip arthroplasties in 9 hips. With radiographic evidence of osteolysis and loosening as the end points, the 15-year survival rates were 28.2% and 56.0%, respectively. CONCLUSIONS: The survival rate of revision total hip arthroplasty in patients with metallosis following a catastrophic failure of a PE liner was low.
Adolescent
;
Adult
;
*Arthroplasty, Replacement, Hip
;
Biocompatible Materials
;
Female
;
Hip Joint/radiography/surgery
;
Hip Prosthesis/*adverse effects
;
Humans
;
Joint Diseases/radiography/*surgery
;
Male
;
Metals/adverse effects
;
Metals, Heavy/*poisoning
;
Middle Aged
;
Osteolysis/etiology/surgery
;
Poisoning/etiology/*surgery
;
Polyethylene/adverse effects
;
Prosthesis Design
;
*Prosthesis Failure/etiology
;
Reoperation
;
Young Adult
8.Spontaneous Acetabular Periprosthetic Fracture in a Patient Continuously Having Zoledronic Acid.
Saran TANTAVISUT ; Aree TANAVALEE ; Voranuch THANAKIT ; Srihatach NGARMUKOS ; Vajara WILAIRATANA ; Yongsak WANGROONGSUB
Clinics in Orthopedic Surgery 2014;6(3):358-360
Zoledronic acid has been used for prevention of osteolytic and osteoblastic bone metastasis. This case report illustrates an undesirable consequence from prolonged usage of zoledronic acid in bone metastasis prevention. Periprosthetic acetabular fracture in a patient treated with zoledronic acid for 7 years was reported. The clinical presentation, radiographic and pathological results were described. This is a rare complication after total hip arthroplasty which should not be ignored especially in patients who received long term bisphosphonate.
Acetabulum/*injuries/pathology/surgery
;
Aged
;
Arthroplasty, Replacement, Hip/*adverse effects
;
Bone Density Conservation Agents/*adverse effects/pharmacology
;
Bone Neoplasms/prevention & control/secondary
;
Bone Remodeling/drug effects
;
Breast Neoplasms/pathology
;
Diphosphonates/*adverse effects/pharmacology
;
Female
;
Fractures, Spontaneous/chemically induced/etiology
;
Hip Prosthesis
;
Humans
;
Imidazoles/*adverse effects/pharmacology
;
Osteoarthritis, Hip/*surgery
;
Periprosthetic Fractures/*chemically induced/etiology
;
Prosthesis Failure
;
Reoperation
9.Results of Revision Surgery and Causes of Unstable Total Knee Arthroplasty.
In Soo SONG ; Doo Hoon SUN ; Jae Gyun CHON ; Sung Won JANG ; Dong Hyuk SUN
Clinics in Orthopedic Surgery 2014;6(2):165-172
BACKGROUND: The aim of this study was to evaluate causes of unstable total knee arthroplasty and results of revision surgery. METHODS: We retrospectively reviewed 24 knees that underwent a revision arthroplasty for unstable total knee arthroplasty. The average follow-up period was 33.8 months. We classified the instability and analyzed the treatment results according to its cause. Stress radiographs, postoperative component position, and joint level were measured. Clinical outcomes were assessed using the Hospital for Special Surgery (HSS) score and range of motion. RESULTS: Causes of instability included coronal instability with posteromedial polyethylene wear and lateral laxity in 13 knees, coronal instability with posteromedial polyethylene wear in 6 knees and coronal and sagittal instability in 3 knees including post breakage in 1 knee, global instability in 1 knee and flexion instability in 1 knee. Mean preoperative/postoperative varus and valgus angles were 5.8degrees/3.2degrees (p = 0.713) and 22.5degrees/5.6degrees (p = 0.032). Mean postoperative alpha, beta, gamma, delta angle were 5.34degrees, 89.65degrees, 2.74degrees, 6.77degrees. Mean changes of joint levels were from 14.1 mm to 13.6 mm from fibular head (p = 0.82). The mean HSS score improved from 53.4 to 89.2 (p = 0.04). The average range of motion was changed from 123degrees to 122degrees (p = 0.82). CONCLUSIONS: Revision total knee arthroplasty with or without a more constrained prosthesis will be a definite solution for an unstable total knee arthroplasty. The solution according to cause is very important and seems to be helpful to avoid unnecessary over-constrained implant selection in revision surgery for total knee instability.
Aged
;
Aged, 80 and over
;
Arthroplasty, Replacement, Knee/*adverse effects
;
Female
;
Humans
;
Joint Instability/*etiology
;
Knee Joint/*surgery
;
Knee Prosthesis
;
Male
;
Middle Aged
;
*Prosthesis Failure
;
Reoperation
;
Retrospective Studies
10.Progress on the relationship between wear debris-induced apoptosis and aseptic loosening of prosthesis.
Guo-Yin LIU ; Jian-Ning ZHAO ; Rui WANG
China Journal of Orthopaedics and Traumatology 2013;26(9):791-796
Aseptic looseningis is one of the most frequent long-term complications after joint replacement, which limits the service lire of prosthesis. A lot of studies have been focused on macrophage, osteoblast, osteoclast and fibroblast in interface membranes around prostheses recently. Aseptic loosening of orthopedic implants used in joint replacement results from bone loss that occurs through the resorptive activity of inflammatory cells activated by the presence of wear particles. Apoptosis has been observed in the periprosthetic site and it has been interpreted as a sign of resolution of inflammation suggesting that apoptosis-related events are indeed associated with periprosthetic osteolysis,targeting the Apoptosis pathway may lead to novel therapeutic approaches for the treatment of aseptic prosthesis loosening. In this thesis,the relationship between wear debris-induced apoptosis and aseptic loosening of prostheses are expounded in detail.
Apoptosis
;
Humans
;
Joint Prosthesis
;
adverse effects
;
Osteolysis
;
Prosthesis Failure
;
etiology

Result Analysis
Print
Save