1.Study of masking ability of laminate veneers for discolored teeth.
Sheng Hao XUE ; Yu Xuan WANG ; Tong Kai XU ; Ting JIANG
Journal of Peking University(Health Sciences) 2020;52(5):943-947
OBJECTIVE:
To select the most effective method among different masking treatments, such as different thickness and transparence, tissue surface's opaque coating, and opaque resin cement to restore discolored teeth esthetically by porcelain veneer.
METHODS:
Four extracted intact maxillary central incisors were prepared for porcelain veneer restoration and each three heat pressed porcelain veneers from three thicknesses (0.8 mm, 1.0 mm, 1.2 mm) and two transparency(high transparence, HT and low transparence, LT))in Vita shade A2 were fabricated for each tooth, in total of 72 pieces. The surfaces of three prepared teeth were then painted to mimic situations of severe dental fluorosis, severe tetracycline teeth, and necrotic teeth. Each of the veneers was temporarily cemented to the corresponding tooth surface using try-in cements with three different colors (transparent, opaque, and yellow), then used the shade guide (3D master) and electronic colorimeter (easy shade) to record the shade of each porcelain veneer through hue, lightness, and chroma reading. After that, high-transparence porcelain veneers in thickness of 0.8 mm was fused with a layer of opaque porcelain in tissue surface, and were shade matched again after cementation. Statistic treatments were performed to analyze the difference in each masking method.
RESULTS:
For each 0.2 mm increase in the veneer thickness of porcelain, the average lightness was reduced by 1 unit, while the chroma was not changed which was independent of the type of the resin cements. When the thickness of the porcelain veneer was decreased to 0.8 mm, the opacity effect was not remarkable even if a low-transparence porcelain veneer was used. Transparent and yellow resin cements had poor opaque performance, while opaque resin cement could reduce the lightness by 2 units and the chroma was also reduced. The opaque layer of the tissue surface could be applied uniformly, and the lightness and chroma could be reduced to Vita 2M1 to 2M1.5 levels regardless of the color of resin cements, which suggested a stable opacity effect for different discolored teeth in this study.
CONCLUSION
For porcelain veneer restoration of discolored teeth, thickened veneers are the most effective means to display a natural transmittance and color. Tissue surface's opacity coatings and opaque resin cements can also be used to reduce grayscale and increase lightness.
Color
;
Humans
;
Materials Testing
;
Prosthesis Coloring
;
Resin Cements
;
Tooth Discoloration/therapy*
2.Comparative study on the shade matching performance of dental students under D55 and D65 light sources conditions.
Xiong YIQING ; Li GANG ; Lin YUNHONG ; Cao ZHIYUN ; Wei YANAN ; Li WEI
West China Journal of Stomatology 2018;36(1):66-70
OBJECTIVE:
This study aimed to compare the effect of D55 and D65 light sources on the visual colorimetry performance of dental students by using a homemade light-source shelf.
METHODS:
Two Vitapan 3D-Master shade guides were randomly selected. One set was used as shade guides. Ten commonly used shade tabs of 2L2.5, 2M2, 2R2.5, 3M2, 3R2.5, 3L1.5, 3R1.5, 3L2.5, 4R1.5, and 4L1.5 were selected from the other set with covered value marks and numbered from 1 to 10. After the colorimetric training, 49 undergraduate dental students were randomly divided into two groups. Each student randomly selected two of the 10 shade tabs, and the colors were subsequently matched under D65 and D55 light sources from a distance of approximately 40 cm. The average color difference (ΔE) between the color selected by each participant and the actual color of shade tabs was calculated. Paired t test was used for statistical analysis.
RESULTS:
The ΔE values between the color selected by each participant and the actual color of the shade tabs under the D55 light source varied from 0 to 6.540. The average value was 2.501. The ΔE values between the color selected by each participant and the actual color of the shade tabs under the D65 light source varied from 0 to 6.610. The average value was 2.530. No statistically significant difference was observed between the results under the two light sources (P=0.921).
CONCLUSIONS
Both D55 and D65 daylight lamps can be used for daily dental colorimetry. These two different color temperatures showed no significant difference.
Color
;
Colorimetry
;
Dental Prosthesis Design
;
Humans
;
Prosthesis Coloring
;
Students, Dental
3.Comparison of the color difference between teeth underwent cold light whitening and two kinds of shade guides.
Journal of Peking University(Health Sciences) 2018;50(3):543-546
OBJECTIVE:
To investigate which shade guide, Vitapan Classical or Vita Bleachedguide 3DMaster, is better matched with the color of teeth in judging whitening effect, by comparing the color difference between shade tabs and corresponding teeth underwent cold light tooth whitening.
METHODS:
A total of 60 patients underwent Beyond cold light tooth whitening from May 2014 to April 2016. The patients were divided into two experimental groups according to the shade guide used. Vitapan Classical shade guide was used to judge whitening effect in one group, and Vita Bleachedguide 3DMaster shade guide was used in another. Shade matching was carried out before and after whitening in both the two groups, and the results were recorded by digital photographs. Shade matching procedures were carried out by two doctors independently. If they chose the same tab, it would be seen as the shade matching result; While if they chose different tabs, another doctor would be invited to make a decision. Photographs were taken in preset conditions: intraoral photos of the full dentition in the front, and the proportion of shooting was 1:3; aperture was F22; shutter speed was 1/200; intensity of flash was M/8; ISO value was 200. The photographs were analyzed by Photoshop software. Chromatic values were measured, and color difference values were calculated. Measuring of chromatic values was carried out by three doctors independently, and all the photos were measured twice by each doctor. Six measure results of each photo were recorded, and the maximum and the minimum were excluded, then the mean was seen as the final result. The color difference values were compared by independent-sample t test. Besides, changes of shade tabs after whitening in the two groups were recorded.
RESULTS:
Color difference value was 5.06±1.71 in Vitapan Classical group, and 3.39±1.36 in Vita Bleachedguide 3D-Master group. There was statistically significant difference between the two groups (t=4.68,P<0.001). Change of shade tabs was 3.63±1.75 in Vitapan Classical group, and 2.23±1.01 in Vita Bleachedguide 3DMaster group.
CONCLUSION
Vita Bleachedguide 3D-Master is better matched with the color of teeth, so it is preferred in judging the effect of cold light tooth whitening.
Color
;
Colorimetry
;
Dentition
;
Humans
;
Photography
;
Prosthesis Coloring
;
Tooth
;
Tooth Bleaching
4.Effect of the amount of thickness reduction on color and translucency of dental monolithic zirconia ceramics.
Hee Kyung KIM ; Sung Hun KIM ; Jai Bong LEE ; Jung Suk HAN ; In Sung YEO ; Seung Ryong HA
The Journal of Advanced Prosthodontics 2016;8(1):37-42
PURPOSE: This study investigated the effect of amount of thickness reduction on color and translucency of dental monolithic zirconia ceramics. MATERIALS AND METHODS: One-hundred sixty-five monolithic zirconia specimens (16.3 mm x 16.3 mm x 2.0 mm) were divided into 5 groups (Group I to V) according to the number of A2-coloring liquid applications. Each group was then divided into 11 subgroups by reducing the thickness up to 1.0 mm in 0.1-mm increments (Subgroup 0 to 10, n=3). Colors and spectral distributions were measured according to CIELAB on a reflection spectrophotometer. All measurements were performed on five different areas of each specimen. Color difference (DeltaE*(ab)) and translucency parameter (TP) were calculated. Data were analyzed using one-way ANOVA and multiple comparison Scheffe test (alpha=.05). RESULTS: There were significant differences in CIE L* between Subgroup 0 and other subgroups in all groups. CIE a* increased (0.52
Ceramics*
;
Prosthesis Coloring
5.Research on the designing method of a special shade guide for tooth whitening.
West China Journal of Stomatology 2015;33(5):478-483
OBJECTIVETo investigate a method of designing an accurate and scientific shade guide, especially used for judging the effect of tooth whitening, by analyzing the colorimetric values of discolored teeth statistically.
METHODSOne hundred thirty-six pictures of patients who had been receiving the Beyond cold light whitening treatment from February 2009 to July 2014 were analyzed, including 25 tetracycline teeth, 61 mottled-enamel teeth, and 50 yellow teeth. The colorimetric values of discolored teeth were measured. The L* values of shade tabs were calculated by hierarchical clustering of those of discolored teeth. The a* and b* values of shade tabs were the mean of those observed for discolored teeth. Accordingly, different shade guides were designed for each type of discolored teeth, and the effects were evaluated.
RESULTSA statistically significant difference in colorimetric values was found among the three types of discolored teeth. Compared with the Vitapan Classical shade guide, the shade guides designed through the present method were more scientific and accurate in judging the effect of tooth whitening. Moreover, the arrangement of shade tabs was more logical, and the color difference between shade tabs and discolored teeth was smaller.
CONCLUSIONThe proposed designing method is theoretically feasible, although its clinical effect has yet to be proven.
Color ; Colorimetry ; Dental Enamel ; Fluorosis, Dental ; Humans ; Incisor ; Light ; Prosthesis Coloring ; Research ; Tooth Bleaching ; methods ; standards ; Tooth Discoloration
6.Effect of colouring green stage zirconia on the adhesion of veneering ceramics with different thermal expansion coefficients.
Guliz AKTAS ; Erdal SAHIN ; Pekka VALLITTU ; Mutlu OZCAN ; Lippo LASSILA
International Journal of Oral Science 2013;5(4):236-241
This study evaluated the adhesion of zirconia core ceramics with their corresponding veneering ceramics, having different thermal expansion coefficients (TECs), when zirconia ceramics were coloured at green stage. Zirconia blocks (N=240; 6 mm×7 mm×7 mm) were manufactured from two materials namely, ICE Zirconia (Group 1) and Prettau Zirconia (Group 2). In their green stage, they were randomly divided into two groups. Half of the specimens were coloured with colouring liquid (shade A2). Three different veneering ceramics with different TEC (ICE Ceramic, GC Initial Zr and IPS e.max Ceram) were fired on both coloured and non-coloured zirconia cores. Specimens of high noble alloys (Esteticor Plus) veneered with ceramic (VM 13) (n=16) acted as the control group. Core-veneer interface of the specimens were subjected to shear force in the Universal Testing Machine (0.5 mm⋅min(-1)). Neither the zirconia core material (P=0.318) nor colouring (P=0.188) significantly affected the results (three-way analysis of variance, Tukey's test). But the results were significantly affected by the veneering ceramic (P=0.000). Control group exhibited significantly higher mean bond strength values (45.7±8) MPa than all other tested groups ((27.1±4.1)-(39.7±4.7) and (27.4±5.6)-(35.9±4.7) MPa with and without colouring, respectively) (P<0.001). While in zirconia-veneer test groups, predominantly mixed type of failures were observed with the veneering ceramic covering <1/3 of the substrate surface, in the metal-ceramic group, veneering ceramic was left adhered >1/3 of the metal surface. Colouring zirconia did not impair adhesion of veneering ceramic, but veneering ceramic had a significant influence on the core-veneer adhesion. Metal-ceramic adhesion was more reliable than all zirconia-veneer ceramics tested.
Adhesiveness
;
Ceramics
;
chemistry
;
Color
;
Dental Bonding
;
Dental Materials
;
chemistry
;
Dental Porcelain
;
chemistry
;
Dental Stress Analysis
;
instrumentation
;
Dental Veneers
;
Gold Alloys
;
chemistry
;
Humans
;
Materials Testing
;
Metal Ceramic Alloys
;
chemistry
;
Prosthesis Coloring
;
Stress, Mechanical
;
Surface Properties
;
Thermodynamics
;
Yttrium
;
chemistry
;
Zirconium
;
chemistry
7.Evaluation of color matching ability according to the color temperature and the experience of practitioner.
Ji Hyun KIM ; Sun Jai KIM ; Keun Woo LEE ; June Sung SHIM ; Joonho YOON
The Journal of Korean Academy of Prosthodontics 2012;50(4):299-304
PURPOSE: The aim of this study is to investigate the effect of different experience level and different light source on shade selection ability comparing prosthodontist group and dental student group under 4,000 K and 5,500 K light. MATERIALS AND METHODS: After color difference of Vitapan 3D-master shade guides was measured, 3 sets of 5 shade tabs were selected with similar value but have different chroma (set a, b, c). Also 3 sets of 5 shade tabs were selected with similar chroma but have different values (set d, e, f). Under 4,000 K and 5,500 K light sources, ten prosthodontists and ten dental students were allowed to match in one set of 5 tabs the same shade tab with the tab which was originally selected in the other set of 5 tabs. Color differences of original tab and matched tab were measured by spectrophotometer and the shade selection ability was evaluated with those data. Evaluation of color difference value was performed in regard to different light conditions and different level of experience, followed by t-test with 95% confidence interval. RESULTS: Color difference values under 4,000 K and 5,500 K light source were 1.62 +/- 2.0, and 1.33 +/- 1.7 respectively. In addition, color difference values of prosthodontist group and dental student group were 1.34 +/- 1.7, and 1.61 +/- 2.0 respectively. Difference of shade selection ability was not found under either different light sources (P=.398), or different experience level (P=.221). CONCLUSION: Level of experience did not affect on the shade selection ability when prosthodontists and dental students matched the shades with the same shade tab under the same light source.
Ceramics
;
Dental Porcelain
;
Humans
;
Light
;
Prosthesis Coloring
;
Spectrophotometry
;
Students, Dental
8.Application of digital photography in color matching in dentistry.
Xiao-ting SHEN ; Yi FAN ; Li LIU ; Yan-zhen ZHANG
Journal of Zhejiang University. Medical sciences 2011;40(4):432-435
OBJECTIVETo develop a new color matching method in dentistry by application of digital photography.
METHODSDigital photographs were obtained of Vitapan 3D-Master shade guide and natural teeth under the same condition, the L*a*b* values of each digital photography were assessed and analyzed by Photoshop CS4.
RESULTSThe Vitapan 3D-Master shade guide was divided into 5 groups, the L* values were similar in each group, but decreased from group 1 to 5. The a* values of L1.5 and L2.5 were minimum, R1.5 and R2.5 were maximum and M1-M3 were intermediate. Compared with Vitapan 3D-Master shade guide, the L*a*b* values of natural teeth were higher.
CONCLUSIONDigital photography can basically reflect the color of Vitapan 3D-Master shade guide, and provides a reference for color matching in dentistry.
Adult ; Color ; Colorimetry ; methods ; Humans ; Photography, Dental ; methods ; Prosthesis Coloring
9.Infinite optical thickness of dentine porcelain of IPS E.max A color series.
Ting SUN ; Long-quan SHAO ; Yuan-fu YI ; Bin DENG ; Ning WEN ; Wei-wei ZHANG
Journal of Southern Medical University 2011;31(2):259-261
OBJECTIVETo determine the infinite optical thickness of dentine porcelain of IPS E.max A color series.
METHODSCylindrical dentine porcelain specimens of the IPS E.max A color series were prepared with a diameter of 13 mm and thickness of 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, and 5.0 mm. The chromatic value of all the specimens was determined with CM-5 spectrometer against standard black and white background. The chromatic aberration (deltaE) was calculated by regression equation.
RESULTSThe infinite optical thickness of dentine porcelain of the IPS E.max A color series ranged from 2.341 to 3.333 mm for a deltaE of 1.0, and from 2.064 to 2.904 mm for a deltaE of 1.5. As the chromaticity or thickness increased, the influence by the background color decreased, and the color of specimens became gradually close to the intrinsic color.
CONCLUSIONThe thickness of the background dentine porcelain specimens must exceed its infinite optical thickness to represent the intrinsic color and avoid the influence by the extrinsic color.
Coated Materials, Biocompatible ; chemistry ; Crowns ; Dental Porcelain ; chemistry ; Dental Prosthesis Design ; Humans ; Prosthesis Coloring ; Tooth Preparation, Prosthodontic ; methods
10.Influence of SiO2 films on color reproduction of Ni-Cr alloy porcelain crowns.
West China Journal of Stomatology 2011;29(4):358-364
OBJECTIVETo study whether SiO2 films will influence the color of Ni-Cr metal ceramic restorations.
METHODSFor the film plating experimental group, Sol-gel method was employed to apply SiO2 films to the surface of the Ni-Cr copings, while no coating was applied for the non-film-plating control group. Veneering porcelains were then applied subsequently, and a total of 12 B2-colored maxillary incisor metal ceramic crowns were fabricated with 6 crowns in each group. A ShadeEye Ncc computer-aided colorimeter was employed to measure the shade of the samples, as well as 6 B2(Vitapan classical vita color tabs) shade standards. The color was expressed as C1E-1976-Lab coordinates.
RESULTSThere was a statistically significant color difference between all metal ceramic crowns and the B2 shade standards (delta E>1.5). The L*, a*, b* values of all crowns were higher than those of the B2 shade standards, and the crowns were typically yellower or redder. While neither significant color difference nor difference in shade values was observed between the film plating experimental group and non-film-plating control group (delta E<1.5).
CONCLUSIONSiO2 films applied to the Ni-Cr copings by means of Sol-gel technique do not impact the final color of the metal ceramic restorations.
Alloys ; Color ; Colorimetry ; Crowns ; Dental Porcelain ; Incisor ; Metal Ceramic Alloys ; Prosthesis Coloring ; Silicon Dioxide

Result Analysis
Print
Save
E-mail