1.Biomechanical effects of medial and lateral translation deviations of femoral components in unicompartmental knee arthroplasty on tibial prosthesis fixation.
Jingting XU ; Jing ZHANG ; Bing ZHANG ; Wen CUI ; Weijie ZHANG ; Zhenxian CHEN
Journal of Biomedical Engineering 2025;42(1):105-112
Prosthesis loosening is the leading cause of postoperative revision in unicompartmental knee arthroplasty (UKA). The deviation of medial and lateral translational installation of the prosthesis during surgery is a common clinical phenomenon and an important factor in increasing the risk of prosthesis loosening. This study established a UKA finite element model and a bone-prosthesis fixation interface micromotion prediction model. The predicted medial contact force and joint motion of the knee joint from a patient-specific lower extremity musculoskeletal multibody dynamics model of UKA were used as boundary conditions. The effects of 9 femoral component medial and lateral translational installation deviations on the Von Mises stress of the proximal tibia, the contact stress, and the micro-motion of the bone prosthesis fixation interface were quantitatively studied. It was found that compared with the neutral position (a/A of 0.492), the lateral translational deviation of the femoral component significantly increased the tibial Von Mises stress and the bone-prosthesis fixation interface contact stress. The maximum Von Mises stress and the maximum contact stress of the fixation interface increased by 14.08% and 143.15%, respectively, when a/A was 0.361. The medial translational deviation of the femoral component significantly increased the bone-prosthesis fixation interface micro-motion. The maximum value of micromotion under the conditions of femoral neutral and medial translation deviation was in the range of 20-50 μm, which is suitable for osseointegration. Therefore, based on considerations such as the micromotion range suitable for osseointegration reported in the literature, the risk of reducing prosthesis loosening, and factors that may induce pain, it is recommended that clinicians control the mounting position of the femoral component during surgery within the safe range of 0-4 mm medial translation deviation.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Finite Element Analysis
;
Biomechanical Phenomena
;
Knee Prosthesis
;
Tibia/surgery*
;
Femur/surgery*
;
Stress, Mechanical
;
Prosthesis Failure
;
Knee Joint/surgery*
;
Prosthesis Design
2.Research on flow characteristics of dual-outlet centrifugal disk blood pumps.
Qilong LIAN ; Yuan XIAO ; Yiping XIAO ; Zhanshuo CAO ; Guomin CUI
Journal of Biomedical Engineering 2025;42(2):374-381
Tesla blood pumps demonstrate a reduced propensity for hemolysis and thrombosis compared with vane blood pumps. Considering the restricted driving force within the secondary flow channel of vane blood pumps, along with the low hydraulic efficiency of conventional Tesla blood pumps and their internal flow characteristics that significantly contribute to hemolysis and thrombosis, this study introduces a set of vanes atop the rotor of the Tesla blood pump. This forms a dual-fluid domain rotor, and an axial dual-outlet volute shell structure is adopted to realize the separation of the fluid domains. Through numerical simulations of the new structure, a comparative analysis was conducted in this study on the internal flow characteristics of double-outlet and single-outlet volute shells, and symmetric and asymmetric cross-sections of the same rotor. The results indicate that the flow field distribution is more uniform under the double-outlet volute shell structure, and overall energy dissipation is decreased. After implementing the double-outlet design, in the asymmetric cross-section, compared with the symmetric cross-section, the fluid velocity gradient and turbulent kinetic energy at the tongue of the septum are reduced, and the fluid velocity gradient at the convergence of the diffuser tube outlets are also decreased. The maximum scalar stress is lower, and the decline in head and efficiency is mitigated. Moreover, compared with the single-outlet volute shell, the hemolysis index in the asymmetric cross-section is reduced. In summary, this paper proposes a novel dual-outlet centrifugal disk blood pumps, which can provide a reference for the structural design and performance optimization of magnetically levitated centrifugal blood pumps.
Heart-Assist Devices
;
Humans
;
Equipment Design
;
Hemolysis
;
Computer Simulation
3.Automatic measurement of acetabular cup anteversion angle using an accurate recognition technology based on improved Otsu algorithm and feature point.
Qian LIU ; Yunqing MA ; Bo WU ; Yao ZHANG ; Jingwen QI ; Yuqian MEI
Journal of Biomedical Engineering 2025;42(3):592-600
The orientation of the acetabular cup in hip joint anteroposterior radiograph is a key factor in evaluating the postoperative outcomes of total hip arthroplasty (THA). Currently, measurement of the acetabular cup anteversion angle primarily relies on manual drawing of auxiliary lines by orthopedic surgeons and calculations using scientific calculators. This study proposes an automated computer-aided measurement method for the acetabular cup anteversion angle based on hip joint anteroposterior radiograph. The proposed method segments hip prosthesis images using an improved Otsu algorithm, identifies feature points at the acetabular cup opening by combining circle-fitting theory and the cup's geometric characteristics, and fits an ellipse to the cup opening to calculate the anteversion angle. A total of 104 hip joint anteroposterior radiographs, including 71 right-sided and 81 left-sided prostheses, were analyzed. Two orthopedic surgeons independently measured the postoperative anteversion angles, and the results were compared with computer-generated measurements for correlation analysis. Spearman and Pearson correlation analyses demonstrated significant correlations between the proposed method and manual measurements for both the right group ( r = 0.795, P < 0.01) and the left group ( r = 0.859, P < 0.01). This method provides a reliable reference for orthopedic surgeons to assess postoperative prognosis.
Humans
;
Acetabulum/anatomy & histology*
;
Arthroplasty, Replacement, Hip/methods*
;
Algorithms
;
Hip Prosthesis
;
Hip Joint/diagnostic imaging*
;
Radiography
;
Image Processing, Computer-Assisted/methods*
4.Effects of elastic modulus of the metal block on the condylar-constrained knee prosthesis tibial fixation stability.
Yuhan ZHANG ; Jing ZHANG ; Tianqi DONG ; Xuan ZHANG ; Weijie ZHANG ; Lei GUO ; Zhenxian CHEN
Journal of Biomedical Engineering 2025;42(4):782-789
Although metal blocks have been widely used for reconstructing uncontained tibial bone defects, the influence of their elastic modulus on the stability of tibial prosthesis fixation remains unclear. Based on this, a finite element model incorporating constrained condylar knee (CCK) prosthesis, tibia, and metal block was established. Considering the influence of the post-restraint structure of the prosthesis, the effects of variations in the elastic modulus of the block on the von Mises stress distribution in the tibia and the block, as well as on the micromotion at the bone-prosthesis fixation interface, were investigated. Results demonstrated that collision between the insert post and femoral prosthesis during tibial internal rotation increased tibial von Mises stress, significantly influencing the prediction of block elastic modulus variation. A decrease in the elastic modulus of the metal block resulted in increased von Mises stress in the proximal tibia, significantly reduced von Mises stress in the distal tibia, decreased von Mises stress of the block, and increased micromotion at the bone-prosthesis fixation interface. When the elastic modulus of the metal block fell below that of bone cement, inadequate block support substantially increased the risk of stress shielding in the distal tibia and fixation interface loosening. Therefore, this study recommends that biomechanical investigations of CCK prostheses must consider the post-constraint effect, and the elastic modulus of metal blocks for bone reconstruction should not be lower than 3 600 MPa.
Knee Prosthesis
;
Humans
;
Finite Element Analysis
;
Tibia/surgery*
;
Elastic Modulus
;
Arthroplasty, Replacement, Knee/methods*
;
Stress, Mechanical
;
Metals
;
Prosthesis Design
;
Knee Joint/surgery*
;
Biomechanical Phenomena
5.Structural design and mechanical analysis of a "drum-shaped" balloon-expandable valve stent in expanded configuration.
Youzhi ZHAO ; Qianwen HOU ; Jianye ZHOU ; Shiliang CHEN ; Hanbing ZHANG ; Aike QIAO
Journal of Biomedical Engineering 2025;42(5):945-953
Stent migration is one of the common complications following transcatheter valve implantation. This study aims to design a "drum-shaped" balloon-expandable aortic valve stent to address this issue and conduct a mechanical analysis. The implantation process of the stent was evaluated using a method that combines numerical simulation and in vitro experiments. Furthermore, the fatigue process of the stent under pulsatile cyclic loading was simulated, and its fatigue performance was assessed using a Goodman diagram. The process of the stent migrating toward the left ventricular side was simulated, and the force-displacement curve of the stent was extracted to evaluate its anti- migration performance. The results showed that all five stent models could be crimped into a 14F sheath and enabled uniform expansion of the native valve leaflets. The stress in each stent was below the ultimate stress, so no fatigue fracture occurred. As the cell height ratio decreased, the contact area fraction between the stent and the aortic root gradually decreased. However, the mean contact force and the maximum anti-migration force first decreased and then increased. Specifically, model S5 had the smallest contact area fraction but the largest mean contact force and maximum anti-migration force, reaching approximately 0.16 MPa and 10.73 N, respectively. The designed stent achieves a "drum-shaped" change after expansion and has good anti-migration performance.
Stents
;
Prosthesis Design
;
Heart Valve Prosthesis
;
Humans
;
Aortic Valve/surgery*
;
Stress, Mechanical
;
Transcatheter Aortic Valve Replacement/instrumentation*
6.Guidelines for computer-aided design/computer-aided manufacturing custom fiber post-and-core.
Chinese Journal of Stomatology 2025;60(1):3-7
The post-and-core is a widely accepted method to restore endodontically treated teeth with compromised tooth structure. Currently, cast metal post-and-core systems and prefabricated fiber posts combined with composite resin cores are the most frequently options in dental clinical practice, but both also come with advantages and limitations. The development of computer-aided design/computer-aided manufacturing (CAD/CAM) custom fiber post-and-core represents one of the significant trends in the advancement of dentistry. Society of Digital Dental Industry, National Association of Health Industry and Enterprise Management organized experts to formulate Guidelines for CAD/CAM custom fiber post-and-core, standardizing the clinical operation procedures of this technology, enhancing the success rate of CAD/CAM custom fiber post-and-core, and promoting its application and development.
Computer-Aided Design
;
Humans
;
Post and Core Technique
;
Composite Resins
;
Dental Prosthesis Design
7.Application of personalized three-dimensional printed customized prostheses in severe Paprosky type Ⅲ acetabular bone defects.
Shuailei LI ; Hao CHAI ; Yongqiang SUN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):13-19
OBJECTIVE:
To analyze the short-term effectiveness and safety of personalized three-dimensional (3D) printed customized prostheses in severe Paprosky type Ⅲ acetabular bone defects.
METHODS:
A retrospective analysis was conducted on 8 patients with severe Paprosky type Ⅲ acetabular bone defects and met the selection criteria between January 2023 and June 2024. There were 3 males and 5 females, with an average age of 64.6 years ranged from 56 to 73 years. All primary replacement prostheses were non-cemented, including 1 ceramic-ceramic interface, 1 ceramic-polyethylene interface, and 6 metal-polyethylene interfaces. The time from the primary replacement to the revision was 4 days to 18 years. The reasons for revision were aseptic loosening in 5 cases, revision after exclusion in 2 cases, and repeated dislocation in 1 case. The preoperative Harris score was 39.5±3.7 and the visual analogue scale (VAS) score was 7.1±0.8. The operation time, intraoperative blood loss, hospital stay, and complications were recorded. The hip function was evaluated by Harris score, and the degree of pain was evaluated by VAS score. The acetabular cup abduction angle, anteversion angle, rotational center height, greater trochanter height, and femoral offset were measured on X-ray film.
RESULTS:
The operation time was 95-223 minutes, with an average of 151.13 minutes. The intraoperative blood loss was 600-3 500 mL, with an average of 1 250.00 mL. The hospital stay was 13-20 days, with an average of 16.88 days. All 8 patients were followed up 2-12 months, with an average of 6.4 months. One patient had poor wound healing after operation, which healed well after active symptomatic treatment. One patient had lower limb intermuscular vein thrombosis, but no thrombosis was found at last follow-up. No serious complications such as aseptic loosening, infection, dislocation, and periprosthetic fracture occurred during the follow-up. At last follow-up, the Harris score was 72.0±6.2 and the VAS score was 1.8±0.7, which were significantly different from those before operation ( t=-12.011, P<0.001; t=16.595, P<0.001). On the second day after operation, the acetabular cup abduction angle ranged from 40° to 49°, with an average of 44.18°, and the acetabular cup anteversion angle ranged from 19° to 26°, with an average of 21.36°, which were within the "Lewinneck safety zone". There was no significant difference in the rotational center height, greater trochanter height, and femoral offset between the healthy side and the affected side ( P>0.05).
CONCLUSION
The use of personalized 3D printed customized prostheses for the reconstruction of severe Paprosky type Ⅲ acetabular bone defects can alleviate pain and enhances hip joint function, and have good postoperative prosthesis position, without serious complications and have good safety.
Humans
;
Printing, Three-Dimensional
;
Male
;
Female
;
Middle Aged
;
Acetabulum/surgery*
;
Aged
;
Retrospective Studies
;
Hip Prosthesis
;
Prosthesis Design
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Reoperation
;
Treatment Outcome
8.Evolution of temporomandibular joint reconstruction: from autologous tissue transplantation to alloplastic joint replacement.
Hanghang LIU ; Liwei HUANG ; Shibo LIU ; Linyi LIU ; Bolun LI ; Zizhuo ZHENG ; Yao LIU ; Xian LIU ; En LUO
International Journal of Oral Science 2025;17(1):17-17
The reconstruction of the temporomandibular joint presents a multifaceted clinical challenge in the realm of head and neck surgery, underscored by its relatively infrequent occurrence and the lack of comprehensive clinical guidelines. This review aims to elucidate the available approaches for TMJ reconstruction, with a particular emphasis on recent groundbreaking advancements. The current spectrum of TMJ reconstruction integrates diverse surgical techniques, such as costochondral grafting, coronoid process grafting, revascularized fibula transfer, transport distraction osteogenesis, and alloplastic TMJ replacement. Despite the available options, a singular, universally accepted 'gold standard' for reconstructive techniques or materials remains elusive in this field. Our review comprehensively summarizes the current available methods of TMJ reconstruction, focusing on both autologous and alloplastic prostheses. It delves into the differences of each surgical technique and outlines the implications of recent technological advances, such as 3D printing, which hold the promise of enhancing surgical precision and patient outcomes. This evolutionary progress aims not only to improve the immediate results of reconstruction but also to ensure the long-term health and functionality of the TMJ, thereby improving the quality of life for patients with end-stage TMJ disorders.
Humans
;
Temporomandibular Joint/surgery*
;
Temporomandibular Joint Disorders/surgery*
;
Transplantation, Autologous
;
Arthroplasty, Replacement/methods*
;
Joint Prosthesis
;
Plastic Surgery Procedures/methods*
9.Practice and challenge of age-friendly functional restoration of stomatognathic system based on the strategy of functional tooth loss.
Yiting CHENG ; Yi MAN ; Yang LIU ; He CAI ; Ran CHENG ; Li CHENG ; Fanglong WU ; Hongkun WU ; Fanyuan YU ; Xueyang LIAO ; Yimin SUN ; Jing WANG ; Xue YANG ; Jinyi ZHU ; Xingqun CHENG ; Zumu YI ; Ling YE ; Tao HU
West China Journal of Stomatology 2025;43(1):15-27
Geriatric oral health care encounters significant challenges with the increase in the proportion of older individuals. Age-related changes in the dentition, muscles, and joints result in a decline in objective masticatory function, subjective restoration requirements, and acceptability among the elderly population, with individual variations influenced by systemic health. Considering functional requirements, the adaptability of stomatognathic and systemic health conditions, health economics and other factors, the authors believe that it should not be limited to the conventional "one-to-one" strategy for replacing missing teeth in geriatric prosthodontics. There is an urgent need for a precise and adaptable restoration strategy that is more suitable for older individuals. The proposal of a new concept of functional tooth loss updates the minimal restoration standards for elderly patients and establishes the theory of age-friendly functional restoration. Based on the restoration strategy of functional tooth loss, this paper proposes a new concept termed "age-friendly functional restoration of the stomatognathic system", which integrates treatment considerations including endodontics, periodontology, mucosa, muscles, temporomandibular joint, and systemic health. Efforts should be made in four areas as follows. Firstly, the "assessment of accessible function" should be enhanced by considering the interrelationship between stomatognathic and systemic health. Secondly, the "evaluation of appropriate function" is supposed to be optimised in view of subjective needs and objective evaluation of the stomatognathic system. Moreover, the "formulation of treatment plans" needs to be accomplished with the aid of assistive technologies, such as artificial intelligence, to accurately exert appropriate functional restoration. Lastly, the "management and maintenance of health" is likely to be strengthened through follow-ups, propaganda and education, and preventive healthcare, so as to improve quality of life and ultimately achieve healthy ageing among older individuals.
Humans
;
Tooth Loss/therapy*
;
Aged
;
Stomatognathic System
;
Oral Health
;
Dental Care for Aged
;
Dental Restoration, Permanent/methods*
10.Geometric position relationship between gingival, preparation, restoration margins and the cementation (adhesive) layer in the marginal area: new classification and scheme for margin position.
West China Journal of Stomatology 2025;43(2):163-174
The current low quality of fixed restoration margins is highly correlated with the high incidence of margin-related complications. It is also related to the unclear spatiotemporal geometric position relationship among the consensus definitions of the gingival margin (G), preparation margin (P), and restoration margin (R). This paper discusses the existing problem of the existing term "gingival margin" as a surface anatomical landmark; proposes the term "free gingival margin line" that conforms to geometry and measurement and has importance as a surface anatomical landmark; and clarifies the participants that exist in the marginal area. These participants include the P, R, and G; cementation (adhesive) layer; and gingival sulcus. Moreover, this paper discusses the various iatrogenic damages induced by entering the gingival sulcus via the P, R, and cementing (adhesive) layer. Through the discussion of the design deficiencies of the subgingival and biologically oriented preparation technique, the physiological and clinical importance of the concept of gingival sulcus/gingival sulcus fluid + supercrestal tissue attachment (biological width) = first periodontal protective barrier was analyzed. The value of preserving the physiological role of the gingival sulcus is emphasized. Furthermore, the newly defined RPG distance represents the distance between the successive P or R line and free G line and can be measured in the clinical procedure of tooth preparation. The optimal solution is 0-200 µm, that is, RPG200: the P and R are located on the free G line and the distance between these margins is less than 200 µm. This distance not only has the aesthetic effect of invisibility to the naked eye, it also has a minimal effect on the G and gingival sulcus and is convenient for doctors and patients to clean. Furthermore, in accordance with the positional relationship between the three margins and cementation (adhesive) layer, a new classification of marginal positions is proposed. This classification overcomes the problems of incomplete inclusion objects and uncontrolled risk factors in the previous classification. It also has the advantages of strong practicability, good efficiency of main control geometric quantity, and clear risk control points. The new design scheme and classification of the margi-nal position of RPG200 proposed in this paper provide a new understanding for margin design and complication prevention in the future.
Humans
;
Gingiva/anatomy & histology*
;
Cementation
;
Dental Restoration, Permanent/methods*

Result Analysis