1.Biocompatibility of 3D printed biodegradable WE43 magnesium alloy scaffolds and treatment of bone defects.
Journal of Peking University(Health Sciences) 2025;57(2):309-316
OBJECTIVE:
To investigate the biocompatibility of porous WE43 magnesium alloy scaffolds manufactured by 3D printing technology and to observe its effect in treating femoral defects in New Zealand white rabbits.
METHODS:
In vitro cytotoxicity test was performed using bone marrow mesenchymal stem cells from Sprague Dawley (S-D) rats. According to the different culture media, the cells were divided into 100% extract group, 50% extract group, 10% extract group and control group. After culturing for 1, 3 and 7 days, the cell activity of each group was determined by cell counting kit-8 (CCK-8). In the in vivo experiment, 3.0-3.5 kg New Zealand white rabbits were randomly divided into three groups: Experimental group, bone cement group and blank group, with 9 rabbits in each group. Each rabbit underwent surgery on the left lateral femoral condyle, and a bone defect with a diameter of 5 mm and a depth of 6 mm was created using a bone drill. The experimental group was implanted with WE43 magnesium alloy scaffolds, the bone cement group was implanted with calcium sulfate bone cement, and the blank group was not implanted. Then 4, 8 and 12 weeks after surgery, 3 rabbits in each group were euthanized by carbon dioxide anesthesia, and the femur and important internal organs were sampled. Micro-computed tomography (Micro-CT) scanning was performed on the left lateral femoral condyle. Sections of important internal organs were prepared and stained with hematoxylin-eosin (HE). Hard tissue sections were made from the left lateral femoral condyle and stained with methylene blue acid fuchsin and observed under a microscope.
RESULTS:
In the cytotoxicity test, the cell survival rate in the 100% extract group was higher than that in the control group (140.56% vs. 100.00%, P < 0.05) on 1 day of culture; there was no statistically significant difference (P>0.05) in cell survival rate among the groups on 3 days of culture; the cell survival rate in the 100% extract group was lower than that in the control group (68.64% vs. 100.00%, P < 0.05) on 7 days of culture. Micro-CT scanning in the in vivo experiment found that most of the scaffolds in the experimental group had been degraded in 4 weeks, with very few high-density scaffolds remaining. In 12 weeks, there was no obvious stent outline. In 4 weeks, a certain amount of gas was generated around the WE43 magnesium alloy scaffold, and the gas was significantly reduced from 8 to 12 weeks. Hard tissue sections showed that a certain amount of extracellular matrix and osteoid were generated around the scaffolds in the experimental group in 4 weeks. In the bone cement group, most of the calcium sulfate bone cement had been degraded. In 8 weeks, the osteoid around the scaffold and its degradation products in the experimental group increased significantly. In 12 weeks, new bone was in contact with the scaffold around the scaffold in the experimental group. There was less new bone in the bone cement group and the blank group.
CONCLUSION
The porous WE43 magnesium alloy scaffold fabricated by 3D printing process has good biocompatibility and good osteogenic properties, and has the potential to become a new material for repairing bone defects.
Animals
;
Rabbits
;
Printing, Three-Dimensional
;
Alloys/chemistry*
;
Tissue Scaffolds/chemistry*
;
Magnesium/chemistry*
;
Rats, Sprague-Dawley
;
Biocompatible Materials
;
Mesenchymal Stem Cells/cytology*
;
Femur/surgery*
;
Rats
;
Absorbable Implants
;
Male
;
Bone Regeneration
;
Tissue Engineering/methods*
;
Cells, Cultured
2.In vitro study of using single cone obturation technique in artificial canals with an isthmus.
Journal of Peking University(Health Sciences) 2025;57(2):369-375
OBJECTIVE:
To evaluate the filling quality of single cone obturation in root canal model with irregular structure (Hus&Kim Ⅴ, Yin Ⅱ-type isthmus) which established by 3D printing technology using slices and radiographic methods, in order to provide reference for clinical practice.
METHODS:
(1) Extracted fresh premolars with Hus&Kim Ⅴ and Yin-type Ⅱ isthmus were collected and scanned by cone-beam computed tomography (CBCT), then standard root canal models were designed and printed. Rhodamine B staining and bias fitting were used to verify the availability of the models. (2) 30 root canal models were randomly divided into 3 groups according to different filling methods (n=10).
CONTROL GROUP:
vertical compaction obturation; Experimental group 1: single cone obturation with 0.06-taper cone (30#); Experimental group 2: single cone obturation with 0.04-taper cone (35#), GuttaFlow 2 as canal sealers. Slices were taken at 2, 4, 6, and 8 mm from the root apex in the direction perpendicular to the long axis of the root and observed under a stereomicroscope to calculate the percentage of filling area (PAV), percentage of gutta-percha-filled area (PGFA), percentage of sealer filled area (PSFA). (3) On the basis of the above results, two groups (n=4) were selected to further analyze the filling quality by micro-computed tomography (Micro-CT), the filling volume of main root canal and the isthmus were obtained, and the percentage of filling volume (PFV) was calculated. Two-way ANOVA was used to evaluate the differences between the groups, and Tukey' s multiple comparison was used to compare the data between the groups and within the groups.
RESULTS:
(1) Rhodamine B staining solution could overflow the apical foramen, and the main root canal system and the isthmus area were stained, showed no remnants of support material. The 3D standard deviation of the printed model data was 0.03 mm, and the average fitting distance was 0.02 mm. (2) The PFA of the two experimental groups were both significantly lower than that of the control group (F=45.04, P < 0.01). There was no statistical difference of the PFA at apical 2 and 4 mm between the two experimental groups (P>0.01), but at the middle and coronal portions of the root canal (6, 8 mm), the PFA of the experimental group 1 was higher than that of the experimental group 2 (P < 0.01). PFA in the apical 2, 4 mm of the two experimental groups were both lower than that in the middle and coronal portions 6, 8 mm of the canal (P < 0.01). There was no difference in the PGFA and PSFA between the two experimental groups at the apical 2, 4 mm (F=2.383, P>0.01). (3) The results of Micro-CT showed that the PFV of the experimental group 1 was statistically different with the control group (F=47.33, P < 0.01). The PFV of the experimental group 1 was 54.33%±4.35% in the isthmus and 78.31%±4.21% in the main root canal, which were both lower than the PFV of the control group of 76.48%±4.89% (isthmus) and 86.90%±3.29% (main root canal, P < 0.01). The PFV of the main root canal in the experimental group 1 was higher than that in the isthmus (P < 0.01), while there was no difference between the isthmus and the main root canal in the control group (P>0.01).
CONCLUSION
In the irregular root canal structure with isthmus, using large-taper gutta-percha can improve the filling quality of the middle and upper part of the canal, but the percentage of filling volume in the isthmus is lower than that of the main canal, and more technical improvements are needed.
Humans
;
Root Canal Obturation/methods*
;
Cone-Beam Computed Tomography
;
Root Canal Filling Materials
;
Dental Pulp Cavity/diagnostic imaging*
;
Printing, Three-Dimensional
;
In Vitro Techniques
;
Gutta-Percha
;
Bicuspid
3.Advances in 3D Printing Technology for Bolus in Radiation Therapy.
Yu CHENG ; Haiyan PENG ; Fu JIN ; Xu MA
Chinese Journal of Medical Instrumentation 2025;49(2):154-160
3D printing technology, with a layer-by-layer construction method, enables the fabrication of intricately shaped and customizable bolus. In contrast to traditional preparation methods, 3D printing technology addresses challenges such as poor bolus fit and cumbersome production processes, offering a novel approach to efficient and personalized bolus fabrication. This article discusses the research progress of 3D printing technology in radiotherapy bolus from aspects such as the preparation process, clinical application, and research advancements, combined with the actual printing experience of Department of Radiation Oncology in Chongqing University Cancer Hospital.
Printing, Three-Dimensional
;
Humans
;
Radiotherapy/methods*
4.Progress of 3D Printing Technology in Resection and Reconstruction of Oral and Maxillofacial Tumors.
Chinese Journal of Medical Instrumentation 2025;49(5):514-519
Oral and maxillofacial tumors, due to their complex anatomical structures and vital physiological functions, pose significant risks, not only affecting patients' appearance and function but also potentially endangering their lives. Traditional tumor resection and reconstruction surgeries face challenges such as inadequate precision, long surgical durations, and unsatisfactory postoperative outcomes. In the treatment of oral and maxillofacial tumors, 3D printing technology can be used for preoperative planning, surgical guide plate production, and the design and manufacture of personalized prosthetics, providing new solutions for functional reconstruction after tumor resection. This article reviews the progress of 3D printing technology in the medical field and explores its potential value in the resection and reconstruction of oral and maxillofacial tumors, aiming to provide references for clinical practice and promote the further application and development of this technology in oral and maxillofacial surgery.
Printing, Three-Dimensional
;
Humans
;
Plastic Surgery Procedures/methods*
;
Mouth Neoplasms/surgery*
5.Three-dimensional (3D) printing-assisted freeze-casting of processed pyritum-doped β-tricalcium phosphate biomimetic scaffold with angiogenesis and bone regeneration capability.
Chenxu WEI ; Zongan LI ; Xiaoyun LIANG ; Yuwei ZHAO ; Xingyu ZHU ; Haibing HUA ; Guobao CHEN ; Kunming QIN ; Zhipeng CHEN ; Changcan SHI ; Feng ZHANG ; Weidong LI
Journal of Zhejiang University. Science. B 2025;26(9):863-880
Bone repair remains an important target in tissue engineering, making the development of bioactive scaffolds for effective bone defect repair a critical objective. In this study, β-tricalcium phosphate (β-TCP) scaffolds incorporated with processed pyritum decoction (PPD) were fabricated using three-dimensional (3D) printing-assisted freeze-casting. The produced composite scaffolds were evaluated for their mechanical strength, physicochemical properties, biocompatibility, in vitro pro-angiogenic activity, and in vivo efficacy in repairing rabbit femoral defects. They not only demonstrated excellent physicochemical properties, enhanced mechanical strength, and good biosafety but also significantly promoted the proliferation, migration, and aggregation of pro-angiogenic human umbilical vein endothelial cells (HUVECs). In vivo studies revealed that all scaffold groups facilitated osteogenesis at the bone defect site, with the β-TCP scaffolds loaded with PPD markedly enhancing the expression of neurogenic locus Notch homolog protein 1 (Notch1), vascular endothelial growth factor (VEGF), bone morphogenetic protein-2 (BMP-2), and osteopontin (OPN). Overall, the scaffolds developed in this study exhibited strong angiogenic and osteogenic capabilities both in vitro and in vivo. The incorporation of PPD notably promoted the angiogenic-osteogenic coupling, thereby accelerating bone repair, which suggests that PPD is a promising material for bone repair and that the PPD/β-TCP scaffolds hold great potential as a bone graft alternative.
Calcium Phosphates/chemistry*
;
Animals
;
Bone Regeneration
;
Rabbits
;
Tissue Scaffolds
;
Printing, Three-Dimensional
;
Humans
;
Human Umbilical Vein Endothelial Cells
;
Neovascularization, Physiologic
;
Osteogenesis
;
Tissue Engineering/methods*
;
Biomimetic Materials
;
Cell Proliferation
;
Angiogenesis
6.Expert consensus on digital restoration of complete dentures.
Yue FENG ; Zhihong FENG ; Jing LI ; Jihua CHEN ; Haiyang YU ; Xinquan JIANG ; Yongsheng ZHOU ; Yumei ZHANG ; Cui HUANG ; Baiping FU ; Yan WANG ; Hui CHENG ; Jianfeng MA ; Qingsong JIANG ; Hongbing LIAO ; Chufan MA ; Weicai LIU ; Guofeng WU ; Sheng YANG ; Zhe WU ; Shizhu BAI ; Ming FANG ; Yan DONG ; Jiang WU ; Lin NIU ; Ling ZHANG ; Fu WANG ; Lina NIU
International Journal of Oral Science 2025;17(1):58-58
Digital technologies have become an integral part of complete denture restoration. With advancement in computer-aided design and computer-aided manufacturing (CAD/CAM), tools such as intraoral scanning, facial scanning, 3D printing, and numerical control machining are reshaping the workflow of complete denture restoration. Unlike conventional methods that rely heavily on clinical experience and manual techniques, digital technologies offer greater precision, predictability, and efficacy. They also streamline the process by reducing the number of patient visits and improving overall comfort. Despite these improvements, the clinical application of digital complete denture restoration still faces challenges that require further standardization. The major issues include appropriate case selection, establishing consistent digital workflows, and evaluating long-term outcomes. To address these challenges and provide clinical guidance for practitioners, this expert consensus outlines the principles, advantages, and limitations of digital complete denture technology. The aim of this review was to offer practical recommendations on indications, clinical procedures and precautions, evaluation metrics, and outcome assessment to support digital restoration of complete denture in clinical practice.
Humans
;
Denture, Complete
;
Computer-Aided Design
;
Denture Design/methods*
;
Consensus
;
Printing, Three-Dimensional
7.Effect of slurry proportion on the microstructure and properties of dental lithium disilicate ceramics manufactured through 3D printing.
Baoxin LIN ; Xiaoxuan CHEN ; Ruyi LI ; Qianbing WAN ; Xibo PEI
West China Journal of Stomatology 2025;43(2):175-182
OBJECTIVES:
This study aims to use 3D prin-ting technology based on the principle of stereo lithography apparatus (SLA) to shape dental lithium disilicate ceramics and study the effects of different slurry proportions on the microstructure and properties of heat-treated samples.
METHODS:
The experimental group comprised lithium disilicate ceramics manufactured through SLA 3D printing, and the control group comprised lithium disilicate ceramics (IPS e.max CAD) fabricated through commercial milling. An array of different particle sizes of lithium disilicate ceramic powder materials (nano and micron) was selected for mixing with photocurable acrylate resin. The proportion of experimental raw materials was adjusted to prepare five groups of ceramic slurries for 3D printing (Groups S1-S5) on the basis of rheological properties, stability, and other factors. Printing, debonding, and sintering were conducted on the experimental group with the optimal ratio, followed by measurements of microstructure, crystallographic information, shrinkage, and mechanical properties.
RESULTS:
Five groups of lithium disilicate ceramic slurries were prepared, of which two groups with high solid content (75%) (Groups S2 and S3) were selected for 3D printing. X-ray diffraction and scanning electron microscopy results showed that lithium disilicate was the main crystalline phase in Groups S2 and S3, and its microstructure was slender, uniform, and compact. The average grain sizes of Groups S2 and S3 were (559.79±84.58) nm and (388.26±61.49) nm, respectively (P<0.05). Energy spectroscopy revealed that the samples in the two groups contained a high proportion of Si and O elements. After heat treatment, the shrinkage rate of the two groups of ceramic samples was 18.00%-20.71%. Test results revealed no statistical difference in all mechanical properties between Groups S2 and S3 (P>0.05). The flexural strengths of Groups S2 and S3 were (231.79±21.71) MPa and (214.86±46.64) MPa, respectively, which were lower than that of the IPS e.max CAD group (P<0.05). The elasticity modulus of Groups S2 and S3 were (87.40±12.99) GPa and (92.87±19.76) GPa, respectively, which did not significantly differ from that of the IPS e.max CAD group (P>0.05). The Vickers hardness values of Groups S2 and S3 were (6.53±0.19) GPa and (6.25±0.12) GPa, respectively, which were higher than that of the IPS e.max CAD group (P<0.05). The fracture toughness values of Groups S2 and S3 were (1.57±0.28) MPa·m0.5 and (1.38±0.17) MPa·m0.5, respectively, which did not significantly differ from that of the IPS e.max CAD group (P>0.05).
CONCLUSIONS
The combination of lithium disilicate ceramic powders with different particle sizes can yield a slurry with high solid content (75%) and suitable viscosity and stability. The dental lithium disilicate ceramic material is successfully prepared by using 3D printing technology. The 3D-printed samples show a small shrinkage rate after heat treatment. Their microstructure conforms to the crystal phase of lithium disilicate ceramics, and their mechanical properties are close to those of milled lithium disilicate ceramics.
Printing, Three-Dimensional
;
Dental Porcelain/chemistry*
;
Ceramics/chemistry*
;
Materials Testing
;
Particle Size
8.Clinical and histological evaluation of three-dimensional printing individualized titanium mesh for alveolar bone defect repair.
Pengyu ZHAO ; Gang CHEN ; Yi CHENG ; Chao WANG ; Dan CHEN ; Haitao HUANG
West China Journal of Stomatology 2025;43(4):592-602
OBJECTIVES:
To evaluate the osteogenic efficacy of three-dimensional printing individualized titanium mesh (3D-PITM) as a scaffold material in guided bone regeneration (GBR).
METHODS:
1) Patients undergoing GBR for alveolar bone defects were enrolled as study subjects, and postoperative healing complications were recorded. 2) Postoperative cone beam computed tomography (CBCT) scans acquired at least 6 months post-surgery were used to calculate the percentage of actual bone formation volume. 3) Alveolar bone specimens were collected during the first-stage implant surgery for histomorphometric analysis. This analysis quantitatively measured the proportions of newly formed bone and newly formed unmineralized bone within the specimens. Specimens were categorized into three groups based on healing complications (good healing group, wound dehiscence group, 3D-PITM exposure group) to compare differences in the proportions of newly formed bone and newly formed unmineralized bone.
RESULTS:
1) Twelve patients were included. Guided bone regeneration failed in one patient, and 3D-PITM exposure occurred in three patients (exposure rate: 25%). 2) The mean percentage of actual bone formation volume in the 11 successful guided bone regeneration cases was 95.23%±28.85%. 3) Histomorphometric analysis revealed that newly formed bone constituted 40.35% of the alveolar bone specimens, with newly formed unmineralized bone accounting for 13.84% of the newly formed bone. Intergroup comparisons showed no statistically significant differences (P>0.05) in the proportions of newly formed bone or newly formed unmineralized bone between the good healing group and the wound dehiscence group or the 3D-PITM exposure group.
CONCLUSIONS
3D-PITM enables effective bone augmentation. Radiographic assessment demonstrated favorable bone formation volume, while histological analysis confirmed substantial formation of newly formed mineralized bone within the surgical site.
Humans
;
Printing, Three-Dimensional
;
Titanium
;
Cone-Beam Computed Tomography
;
Bone Regeneration
;
Osteogenesis
;
Surgical Mesh
;
Tissue Scaffolds
;
Alveolar Process/surgery*
;
Adult
;
Male
;
Middle Aged
;
Female
;
Wound Healing
;
Guided Tissue Regeneration, Periodontal/methods*
;
Alveolar Bone Loss/surgery*
9.Digital design and manufacturing method of double constrained split guide for orthodontic miniscrew implantation.
Xin DU ; Aonan WEN ; Zixiang GAO ; Zhihua LI ; Sheng ZHANG ; Yong WANG ; Yijiao ZHAO
West China Journal of Stomatology 2025;43(4):603-612
This study explored a novel digital design and fabrication method for a double constrained split orthodontic miniscrew guide to improve the accuracy and safety of clinical miniscrew implantation and reduce related complications. A patient requiring miniscrew implantation was selected, and data were acquired using cone beam computed tomography (CBCT) and intraoral optical scanning. For the construction of a double constrained split guide including a screw-hole guide and an insertion rod guide, different types of software such as Mimics 24.0, Geomagic wrap 2021, and Materialise magics 21.0 were utilized for 3D reconstruction, model integration, and guide design. The guide was then fabricated via laser metal 3D printing. Model and intraoral try-in results demonstrated that the guide fitted well and was stable. Postoperative CBCT verified that the final miniscrew implantation site was consistent with the preoperative design, and no related complications occurred. This double constrained split orthodontic miniscrew guide provides a precise and safe digital solution for clinical miniscrew implantation.
Humans
;
Bone Screws
;
Cone-Beam Computed Tomography
;
Printing, Three-Dimensional
;
Orthodontic Anchorage Procedures/instrumentation*
;
Imaging, Three-Dimensional
;
Computer-Aided Design
10.Preliminary study on the influence of the dimensional stability of 3D printed resin master model on the replication accuracy of implant replicas.
Xin LI ; Yuzong LU ; Yongtao YANG ; Aonan WEN ; Yong WANG ; Yijiao ZHAO
West China Journal of Stomatology 2025;43(5):689-695
OBJECTIVES:
This study aimed to investigate the influence of the dimensional stability of 3D printed resin master model on the replication accuracy of implant replicas.
METHODS:
Ten digital impressions of patients undergoing continuous crowns or fixed bridge restoration supported by two implants were obtained, and resin models with implant replicas were 3D printed. Scanning rods were fixed on the replicas 3, 7, and 14 days after printing. The 3D, linear, and angular deviations of the scanning rods at different times were analyzed through Geomagic Wrap 2021 software.
RESULTS:
The position of the replicas shifted mesiolingually, in the same direction as the shrinkage of the model. From day 7 onward, the 3D, distance linear, and angular deviations of the replicas (scanning rod) significantly increased compared with those on the 3rd day (P<0.05). On the 14th day, the changes were even more pronounced, with the above deviations showing statistical significance (P<0.05) compared with those for the 3-day and 7-day groups. No statistical difference in height linear deviation was observed among the groups.
CONCLUSIONS
The insufficient dimensional stability of 3D printed resin models can lead to changes in the relative position and angle of the replicas, thereby affecting the accuracy of the replicas in recreating the implant's position. Complete manufacturing of prosthesis is recommended within 7 days after the model is printed.
Printing, Three-Dimensional
;
Humans
;
Dental Implants
;
Models, Dental
;
Dental Impression Technique
;
Crowns

Result Analysis