1.Comparison of displacement of polyvinyl chloride and silicone left-sided double-lumen tubes during lateral positioning
Nyeong Keon KWON ; Sung Mee JUNG ; Sang Jin PARK ; Yonghee HAN
Korean Journal of Anesthesiology 2019;72(1):32-38
BACKGROUND: Compared to an equivalent sized polyvinyl chloride (PVC) double-lumen tube (DLT), a silicone DLT has a shorter endobronchial segment. The aim of this study was to compare the incidence of clinically significant displacement of left-sided PVC and silicone DLTs after a positional change to a lateral position from a supine position and determine its effect on the need for DLT repositioning for successful lung separation in patients undergoing thoracic surgery. METHODS: One hundred eight adult patients requiring one-lung ventilation were randomly divided into group P (PVC DLT, n = 54) and group S (Silicone DLT, n = 54). The position of the DLT was observed before and after lateral positioning to assess the effect of the position change. The incidence of clinically significant displacement (>10 mm) of DLT was compared between the groups. RESULTS: DLTs were clinically significantly displaced in group P (17/48, 35.4%) and group S (18/52, 34.6%) after lateral positioning (p = 0.933). A proximal displacement (31.3% [group P] and 25.0% [group S]) was more common than distal displacement (4.2% [group P] and 9.6% [group S]), with no significant intergroup difference (p = 0.494). After lateral positioning, critical malposition of DLT with bronchial herniation to the right main bronchus was 8.3% (group P) and 7.9% (group S, p = 0.906). CONCLUSION: Left-sided PVC and silicone DLTs produced comparable incidences of clinically significant displacement and, consequently, required similar rates of repositioning for successful lung separation after lateral positioning.
Adult
;
Bronchi
;
Bronchoscopy
;
Humans
;
Incidence
;
Intubation, Intratracheal
;
Lung
;
One-Lung Ventilation
;
Polyvinyl Chloride
;
Polyvinyls
;
Posture
;
Silicon
;
Silicones
;
Supine Position
;
Thoracic Surgery
;
Thoracic Surgical Procedures
2.Experimental Study on Migration Parameters of DEHP in PVC Infusion.
Jun WANG ; Yan WU ; Shiyong BAO ; Hongqiang JIANG ; Guoli SHEN ; Ningqing CHEN
Chinese Journal of Medical Instrumentation 2019;43(2):132-135
The work explored the DEHP migration parameters in PVC infusion in clinic,based on the previous research on the test model of DEHP migrated from PVC infusion,to assess the safety of PVC infusion.The leaching solution samples in different conditions were evaluated by analysis of the DEHP in leaching solution using GC-MS under simulated clinical transfusion way.The release behavior of DEHP was significantly affected by the storage time,storage temperature,surrounding temperature,dripping speed,sterilization process,volume of the leaching solution,and the property of the leaching solution.
Diethylhexyl Phthalate
;
pharmacokinetics
;
Gas Chromatography-Mass Spectrometry
;
Plasticizers
;
pharmacokinetics
;
Polyvinyl Chloride
;
pharmacokinetics
;
Temperature
3.Application and Safety Evaluation of DEHP in PVC Medical Devices.
Yue WANG ; Xin XIE ; Hongqiang JIANG ; Jun WANG
Chinese Journal of Medical Instrumentation 2018;42(4):293-295
DEHP is largely used in soft PVC products as the plasticizer, which is also widely applied in medical devices. Due to its potential and widespread toxicity and medical devices' specific use, the safety of DEHP's application in medical devices has received extensive attention. In this paper, a comprehensive review of the application and potential toxicity of DEHP in PVC medical devices is made on the basis of the research results all over the world. Besides, the safety evaluation in medical devices is discussed and some possible coping strategies are explored.
Diethylhexyl Phthalate
;
adverse effects
;
Equipment Safety
;
Equipment and Supplies
;
adverse effects
;
Plasticizers
;
adverse effects
;
Polyvinyl Chloride
4.Research on Experimental Model of Security Assessment of DEHP Migration from PVC-Tubes Medical Devices.
Yue WANG ; Shiyong BAO ; Guoli SHEN ; Jun WANG ; Hongqiang JIANG
Chinese Journal of Medical Instrumentation 2018;42(3):222-224
As we all know, DEHP is seriously harmful to human health and consequently has been acquired critical attention. DEHP is able to migrate from PVC medical devices for the non-chemically bound to PVC, thus contact with user and patient. The DEHP migration is influenced by various parameters. In order to assess the security of PVC-tubes medical devices scientifically of DEHP migration, we develop an experimental model by analyzing the parameters comprehensively and systematically, taking into account the clinical practices. For example, assessing the security of DEHP migration from infusion sets by utilizing this model.
Diethylhexyl Phthalate
;
adverse effects
;
Equipment and Supplies
;
Humans
;
Models, Theoretical
;
Plasticizers
;
adverse effects
;
Polyvinyl Chloride
5.Comparison of Intubation Efficiency by Suction Device in a Hemorrhagic Airway Manikin Model: Yankauer Suction Tip vs. Polyvinyl Chloride Catheter Suction Tip
Hyo Bin LEE ; Yoon Sun JUNG ; Gil Joon SUH ; Woon Yong KWON
Journal of the Korean Society of Emergency Medicine 2018;29(1):44-50
PURPOSE: Tracheal intubation in a hemorrhagic airway is a difficult procedure because the visibility can be obscured by blood or vomitus. Several devices and methods have been developed to overcome such obstacles, but they are not available at all practical sites. Therefore, this study was conducted to assess the time and success rate of tracheal intubation according to the type of suction tip used in a hemorrhagic airway manikin model. METHODS: This study was a randomized crossover manikin simulation study. We recruited 18 emergency physicians to perform intubation with suction using a Yankauer suction tip and a polyvinyl chloride (PVC) catheter suction tip in a hemorrhagic airway manikin model. We then measured the time and success rate of intubation for each suction tip. RESULTS: The mean intubation time using the Yankauer suction tip was 42.3 seconds, and the mean intubation time using the PVC catheter suction tip was 91.1 seconds (p < 0.001). Two cases of esophageal intubation occurred when the PVC catheter suction tip was used (success rate, 88.9%). In contrast, there was no esophageal intubation when the Yankauer suction tip was used (success rate, 100%) (p=0.217). CONCLUSION: Intubation of a hemorrhagic airway manikin model can be performed in a shorter time when a Yankauer suction tip is used than when a PVC catheter suction tip is used.
Catheters
;
Emergencies
;
Hemorrhage
;
Intubation
;
Manikins
;
Polyvinyl Chloride
;
Polyvinyls
;
Suction
6.Prediction of air inflow during central venous catheter insertion: experimental study.
Hyo Jae JUNG ; Yang Weon KIM ; Chang Min PARK ; Chul Ho PARK ; Ji Hun KANG ; Yoo Sang YOON
Journal of the Korean Society of Emergency Medicine 2018;29(6):641-648
OBJECTIVE: This study examined the incidence and amount of air inflow during central venous catheter (CVC) insertion. METHODS: This study was an experimental study aimed at designing an apparatus to implement blood vessel and blood flow in the human body. A 1.5-m long core tube with a Teflon tube, suction rubber tube, and polyvinyl chloride tube were made. This core tube was assumed to be the blood vessel of the human body. Blood was replaced with a saline solution. The saline solution was placed higher than the core tube and flowed into the inside of the tube by gravity. The CVC was injected 15-cm deep into the core tube. The air was collected through a 3-way valve into the upper tube. The experiments were carried out by differentiating the pressure in the tube, CVC insertion step, and diameter of the end of the catheter. The experiment was repeated 10 times under the same conditions. RESULTS: The amount of air decreased with increasing pressure applied to the tube. Air was not generated when the syringe needle was injected, and the amount of air increased with increasing size of the distal end catheter. CONCLUSION: To minimize the possibility of air embolism, it is necessary to close the distal end catheter at the earliest point as soon as possible.
Blood Vessels
;
Catheters
;
Central Venous Catheters*
;
Embolism, Air
;
Gravitation
;
Human Body
;
Incidence
;
Jugular Veins
;
Needles
;
Polytetrafluoroethylene
;
Polyvinyl Chloride
;
Rubber
;
Sodium Chloride
;
Suction
;
Syringes
7.Case Report of Occupational Asthma Induced by Polyvinyl Chloride and Nickel.
Ga Won SONG ; Ga Young BAN ; Young Hee NAM ; Hae Sim PARK ; Young Min YE
Journal of Korean Medical Science 2013;28(10):1540-1542
Polyvinyl chloride (PVC) is a widely used chemical for production of plastics. However occupational asthma (OA) caused by PVC has been reported only rarely. We report a 34-yr-old male wallpaper factory worker with OA due to PVC and nickel (Ni) whose job was mixing PVC with plasticizers. He visited the emergency room due to an asthma attack with moderate airflow obstruction and markedly increased sputum eosinophil numbers. A methacholine challenge test was positive (PC20 2.5 mg/mL). Bronchoprovocation tests with both PVC and Ni showed early and late asthmatic responses, respectively. Moreover, the fractional concentration of exhaled nitric oxide (FeNO) was increased after challenge with PVC. To our knowledge, this is the first case of OA in Korea induced by exposure to both PVC and Ni. We suggest that eosinophilic inflammation may be involved in the pathogenesis of PVC-induced OA and that FeNO monitoring can be used for its diagnosis.
Adult
;
Asthma, Occupational/*chemically induced/*diagnosis
;
Breath Tests
;
Bronchial Provocation Tests
;
Environmental Exposure
;
Eosinophilia/*diagnosis
;
Exhalation
;
Humans
;
Leukocyte Count
;
Male
;
Nickel
;
Nitric Oxide/metabolism
;
Occupational Exposure
;
Plasticizers
;
Polyvinyl Chloride
8.Retrograde Intubation in Patients with Severe Cervical Ankylosing Spondylitis: A Laryngeal Mask Airway (LMA) Combined Technique.
Jae Woo KIM ; Duck Ho JUN ; Ho Jung KIM
Journal of the Korean Society of Emergency Medicine 2012;23(3):427-429
Occurrence of cervical spineankylosis is rare, and intubation of patients with this condition can be difficult, particularly when fiberoptic laryngoscopy is not available. We performed successful endotracheal intubation in a 64-year-old male patient using a 7-mm cuffed polyvinyl chloride (PVC) tube with the help of a laryngeal mask airway (LMA). The LMA was initially used for rapid ventilation of the patient, and the guide wire was passed into the airway from the site of puncture of the cricothyroid membrane. This wire was easily observed in the LMA tube, and the use of long forceps was not required.
Ankylosis
;
Humans
;
Intubation
;
Intubation, Intratracheal
;
Laryngeal Masks
;
Laryngoscopy
;
Male
;
Membranes
;
Middle Aged
;
Polyvinyl Chloride
;
Punctures
;
Surgical Instruments
;
Ventilation
9.Safety assessment of DEHP from PVC medical devices.
Chinese Journal of Medical Instrumentation 2012;36(2):118-120
OBJECTIVETo Investigate necessity of safety evaluation, research ideas, evaluation methods of DEHP in PVC medical devices.
METHODSThe ideas of The United States, Japan and the European Union on safety evaluation of DEHP in PVC medical devices was reviewed and sorted, regarding to currently requirements for PVC medical devices in our country, the research ideas and methods of DEHP in PVC medical devices was explored.
RESULTSDEHP released from High-risk PVC medical devices may exceed human tolerance intake values and thus potentially be harmful to human health. So it is necessary for production enterprise to assess safety of DEHP in PVC medical device. The assessment can be done by material control and detecting release of DEHP from PVC medical devices.
CONCLUSIONIn order to assess safety of DEHP in PVC medical device, production enterprise can firstly assess materials according to national standard. Secondly, production enterprise can detect release of DEHP from PVC medical devices simulating clinical application. By comparing release of DEHP from PVC medical devices and TI, safety of DEHP in PVC medical device can be evaluated.
Diethylhexyl Phthalate ; adverse effects ; Equipment Safety ; Plasticizers ; adverse effects ; Polyvinyl Chloride ; adverse effects
10.Preparation and antithrombogenicity of oxidated low molecular weight heparin-antithrombin complex coated-polyvinyl chloride tubing.
Peng LUO ; Weiyong LIU ; Chun YANG ; Hua ZHOU ; Ruijun CAO ; Jian YANG
Journal of Biomedical Engineering 2011;28(1):90-94
Based on non-enzymatic protein glycated reaction, the sodium periodate-oxidated low molecular weight heparin-antithrombin covalent complex (SPLMWATH) was produced. By using polyethyleneimine-glutaraldehyde bonding technique, polyvinyl chloride (PVC) tubings were coated with SPLMWATH, heparin and low molecular weight heparin (LMWH). Spectrophotometry and dynamic clotting time experiment were used to determine the synthetic ratio of SPLMWATH, graft density, coating leaching ratio and to evaluate the antithrombogenicity of different coating on the PVC tubings. The results showed that the synthetic ratio of SPLMWATH was approximately 55%, and compared with heparin coating and LMWH coating, the graft density of SPLMWATH coating on the PVC tubing was smaller, but its coating stability and antithrombogenicity were significantly better than that of heparin coating and LMWH coating on the PVC tubings.
Anticoagulants
;
chemical synthesis
;
pharmacology
;
Coated Materials, Biocompatible
;
chemical synthesis
;
pharmacology
;
Extracorporeal Circulation
;
instrumentation
;
Heparin, Low-Molecular-Weight
;
chemistry
;
pharmacology
;
Humans
;
Polyvinyl Chloride
;
chemistry
;
Surface Properties

Result Analysis
Print
Save
E-mail