1.Rapid Discrimination of Processing Degree of Wine-processed Chuanxiong Rhizoma Based on Intelligent Sensory Technology and Multivariate Statistical Analysis
Xiaolong ZHANG ; Xiaoni MA ; Xinzhu WANG ; Po HU ; Yang PAN ; Tulin LU ; Guangming YANG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(3):174-182
ObjectiveTo explore the changes in color, odor and chemical components during wine-processing of Chuanxiong Rhizoma(CR), identify differential markers, and provide a basis for standardizing the process and establishing quality standards. MethodsFifteen batches of CR samples from 4 producing areas were collected. Colorimeter and electronic nose were used to detect the color changes and odor components of CR before and after wine-processing. Multivariate statistical methods including partial least squares-discriminant analysis(PLS-DA), principal component analysis(PCA), discriminant factor analysis(DFA) and Fisher discriminant analysis were applied to identify wine-processed CR at different processing stages and establish discriminant models, and differential components were screened out based on variable importance in the projection(VIP) value1. Then, high performance liquid chromatography(HPLC) was employed to detect the content changes of four components(ferulic acid, senkyunolide I, senkyunolide A and ligustilide) during the processing stages. ResultsThe differences of wine-processed CR at various stages were primarily reflected in color parameters L*(brightness value), a*(red-green value) and b*(yellow-blue value). Based on chromaticity differences, the color reference ranges were established for moderately processed CR, including L* of 46.75-48.24, a* of 5.37-6.07 and b* of 20.32-21.70. In odor analysis, DFA revealed significant differences among processing stages, and 11 odor markers were identified, with four differential markers(4-hydroxy-3-butylphthalide, isopropyl butyrate, L-limonene and 1-methoxyhexane) based on VIP values. HPLC results showed that there was no significant difference of the four components except for ligustilide in wine-processed CR at different stages. ConclusionThis study achieved rapid identification of wine-processed CR with different processing degrees by electronic sensory technology and differential component content detection, with discrimination accuracy rates of 92.4% and 93.272% for color and odor, respectively. This paper also established the reference ranges of main colorimetric parameters for wine-processed CR at different stages, and four differential components were screened out, providing a basis for standardizing the processing of wine-processed CR and establishing quality standards for this decoction pieces.
2.Rapid Discrimination of Processing Degree of Wine-processed Chuanxiong Rhizoma Based on Intelligent Sensory Technology and Multivariate Statistical Analysis
Xiaolong ZHANG ; Xiaoni MA ; Xinzhu WANG ; Po HU ; Yang PAN ; Tulin LU ; Guangming YANG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(3):174-182
ObjectiveTo explore the changes in color, odor and chemical components during wine-processing of Chuanxiong Rhizoma(CR), identify differential markers, and provide a basis for standardizing the process and establishing quality standards. MethodsFifteen batches of CR samples from 4 producing areas were collected. Colorimeter and electronic nose were used to detect the color changes and odor components of CR before and after wine-processing. Multivariate statistical methods including partial least squares-discriminant analysis(PLS-DA), principal component analysis(PCA), discriminant factor analysis(DFA) and Fisher discriminant analysis were applied to identify wine-processed CR at different processing stages and establish discriminant models, and differential components were screened out based on variable importance in the projection(VIP) value1. Then, high performance liquid chromatography(HPLC) was employed to detect the content changes of four components(ferulic acid, senkyunolide I, senkyunolide A and ligustilide) during the processing stages. ResultsThe differences of wine-processed CR at various stages were primarily reflected in color parameters L*(brightness value), a*(red-green value) and b*(yellow-blue value). Based on chromaticity differences, the color reference ranges were established for moderately processed CR, including L* of 46.75-48.24, a* of 5.37-6.07 and b* of 20.32-21.70. In odor analysis, DFA revealed significant differences among processing stages, and 11 odor markers were identified, with four differential markers(4-hydroxy-3-butylphthalide, isopropyl butyrate, L-limonene and 1-methoxyhexane) based on VIP values. HPLC results showed that there was no significant difference of the four components except for ligustilide in wine-processed CR at different stages. ConclusionThis study achieved rapid identification of wine-processed CR with different processing degrees by electronic sensory technology and differential component content detection, with discrimination accuracy rates of 92.4% and 93.272% for color and odor, respectively. This paper also established the reference ranges of main colorimetric parameters for wine-processed CR at different stages, and four differential components were screened out, providing a basis for standardizing the processing of wine-processed CR and establishing quality standards for this decoction pieces.
3.Effect of Anti-reflux Mucosal Ablation on Esophageal Motility in Patients With Gastroesophageal Reflux Disease: A Study Based on High-resolution Impedance Manometry
Chien-Chuan CHEN ; Chu-Kuang CHOU ; Ming-Ching YUAN ; Kun-Feng TSAI ; Jia-Feng WU ; Wei-Chi LIAO ; Han-Mo CHIU ; Hsiu-Po WANG ; Ming-Shiang WU ; Ping-Huei TSENG
Journal of Neurogastroenterology and Motility 2025;31(1):75-85
Background/Aims:
Anti-reflux mucosal ablation (ARMA) is a promising endoscopic intervention for proton pump inhibitor (PPI)-dependent gastroesophageal reflux disease (GERD). However, the effect of ARMA on esophageal motility remains unclear.
Methods:
Twenty patients with PPI-dependent GERD receiving ARMA were prospectively enrolled. Comprehensive self-report symptom questionnaires, endoscopy, 24-hour impedance-pH monitoring, and high-resolution impedance manometry were performed and analyzed before and 3 months after ARMA.
Results:
All ARMA procedures were performed successfully. Symptom scores, including GerdQ (11.16 ± 2.67 to 9.11 ± 2.64, P = 0.026) and reflux symptom index (11.63 ± 5.62 to 6.11 ± 3.86, P = 0.001), improved significantly, while 13 patients (65%) reported discontinuation of PPI. Total acid exposure time (5.84 ± 4.63% to 2.83 ± 3.41%, P = 0.024) and number of reflux episodes (73.05 ± 19.34 to 37.55 ± 22.71, P < 0.001) decreased significantly after ARMA. Improved esophagogastric junction (EGJ) barrier function, including increased lower esophageal sphincter resting pressure (13.89 ± 10.78 mmHg to 21.68 ± 11.5 mmHg, P = 0.034), 4-second integrated relaxation pressure (5.75 ± 6.42 mmHg to 9.99 ± 5.89 mmHg, P = 0.020), and EGJ-contractile integral(16.42 ± 16.93 mmHg · cm to 31.95 ± 21.25 mmHg · cm, P = 0.016), were observed. Esophageal body contractility also increased significantly (distal contractile integral, 966.85 ± 845.84 mmHg · s · cm to 1198.8 ± 811.74 mmHg · s · cm, P = 0.023). Patients with symptom improvement had better pre-AMRA esophageal body contractility.
Conclusions
ARMA effectively improves symptoms and reflux burden, EGJ barrier function, and esophageal body contractility in patients with PPIdependent GERD during short-term evaluation. Longer follow-up to clarify the sustainability of ARMA is needed.
4.In-room cytologic evaluation by trained endosonographer for determination of procedure end in endoscopic ultrasound-guided fine needle biopsy of solid pancreatic lesions: a prospective study in Taiwan
Weng-Fai WONG ; Yu-Ting KUO ; Wern-Cherng CHENG ; Chia-Tung SHUN ; Ming-Lun HAN ; Chieh-Chang CHEN ; Hsiu-Po WANG
Clinical Endoscopy 2025;58(3):465-473
Background/Aims:
Endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) is an essential tool for tissue acquisition in solid pancreatic tumors. Rapid on-site evaluation (ROSE) by cytologists ensures diagnostic accuracy. However, the universal application of the ROSE is limited by its availability. Therefore, we aimed to investigate the feasibility of determining the end of the procedure based on the results of in-room cytological evaluation by trained endosonographers (IRCETE).
Methods:
A training course focusing on the cytological interpretation of common pancreatic tumors was provided to the three endosonographers. After training, the decision to terminate EUS-FNB was made based on IRCETE results. The diagnostic accuracy, concordance rate of diagnostic categories, and sample adequacy were compared with those determined by board-certified cytologists and macroscopic on-site evaluation (MOSE).
Results:
We enrolled 65 patients with solid pancreatic tumors, most of whom were malignant (86.2%). The diagnostic accuracy was 90.8% when the end of the procedure was determined based on IRCETE, compared to 87.7% and 98.5% when determined by MOSE and cytologists, respectively (p=0.060). Based on the cytologists’ results, the accuracy of IRCETE in diagnostic category interpretation was 97.3%.
Conclusions
In the absence of ROSE, IRCETE can serve as a supplementary alternative to MOSE in determining the end of tissue sampling with a high accuracy rate.
5.In-room cytologic evaluation by trained endosonographer for determination of procedure end in endoscopic ultrasound-guided fine needle biopsy of solid pancreatic lesions: a prospective study in Taiwan
Weng-Fai WONG ; Yu-Ting KUO ; Wern-Cherng CHENG ; Chia-Tung SHUN ; Ming-Lun HAN ; Chieh-Chang CHEN ; Hsiu-Po WANG
Clinical Endoscopy 2025;58(3):465-473
Background/Aims:
Endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) is an essential tool for tissue acquisition in solid pancreatic tumors. Rapid on-site evaluation (ROSE) by cytologists ensures diagnostic accuracy. However, the universal application of the ROSE is limited by its availability. Therefore, we aimed to investigate the feasibility of determining the end of the procedure based on the results of in-room cytological evaluation by trained endosonographers (IRCETE).
Methods:
A training course focusing on the cytological interpretation of common pancreatic tumors was provided to the three endosonographers. After training, the decision to terminate EUS-FNB was made based on IRCETE results. The diagnostic accuracy, concordance rate of diagnostic categories, and sample adequacy were compared with those determined by board-certified cytologists and macroscopic on-site evaluation (MOSE).
Results:
We enrolled 65 patients with solid pancreatic tumors, most of whom were malignant (86.2%). The diagnostic accuracy was 90.8% when the end of the procedure was determined based on IRCETE, compared to 87.7% and 98.5% when determined by MOSE and cytologists, respectively (p=0.060). Based on the cytologists’ results, the accuracy of IRCETE in diagnostic category interpretation was 97.3%.
Conclusions
In the absence of ROSE, IRCETE can serve as a supplementary alternative to MOSE in determining the end of tissue sampling with a high accuracy rate.
6.Role of miR-130b-3p/USP47/NLRP3 inflammasome in airway remodeling in asthma
Chang-lin QUAN ; Zhi-guang WANG ; Qiao-yun BAI ; Ning-po DING ; Yi-lan SONG ; Guang-hai YAN
Chinese Pharmacological Bulletin 2025;41(8):1500-1508
Aim To investigate the role of miR-130b-3p in regulating the USP47/NLRP3 inflammasome in airway remodeling associated with asthma and to explore its potential therapeutic value in asthma treat-ment.Methods An OVA-induced asthma mouse mod-el was established,and intervention with miR-130b-3p agomir was performed.Histological staining,quantita-tive real-time PCR,Western blot,immunofluorescence and flow cytometry were used to analyze the effects of miR-130b-3p on the expression of USP47,NLRP3,and related inflammatory factors,as well as the inflamma-some activity.Results miR-130b-3p was significantly downregulated in asthmatic mice,and its intervention significantly inhibited airway epithelial damage,inflam-matory cell infiltration,and collagen deposition.Addi-tionally,miR-130b-3p targeted USP47 and indirectly suppressed NLRP3 expression,leading to reduced in-flammasome activity and alleviated asthma-related in-flammatory responses.Conclusion miR-130b-3p re-duces asthma-related inflammatory responses by down-regulating USP47 expression and indirectly inhibiting NLRP3 inflammasome activity.
7.Effect of Anti-reflux Mucosal Ablation on Esophageal Motility in Patients With Gastroesophageal Reflux Disease: A Study Based on High-resolution Impedance Manometry
Chien-Chuan CHEN ; Chu-Kuang CHOU ; Ming-Ching YUAN ; Kun-Feng TSAI ; Jia-Feng WU ; Wei-Chi LIAO ; Han-Mo CHIU ; Hsiu-Po WANG ; Ming-Shiang WU ; Ping-Huei TSENG
Journal of Neurogastroenterology and Motility 2025;31(1):75-85
Background/Aims:
Anti-reflux mucosal ablation (ARMA) is a promising endoscopic intervention for proton pump inhibitor (PPI)-dependent gastroesophageal reflux disease (GERD). However, the effect of ARMA on esophageal motility remains unclear.
Methods:
Twenty patients with PPI-dependent GERD receiving ARMA were prospectively enrolled. Comprehensive self-report symptom questionnaires, endoscopy, 24-hour impedance-pH monitoring, and high-resolution impedance manometry were performed and analyzed before and 3 months after ARMA.
Results:
All ARMA procedures were performed successfully. Symptom scores, including GerdQ (11.16 ± 2.67 to 9.11 ± 2.64, P = 0.026) and reflux symptom index (11.63 ± 5.62 to 6.11 ± 3.86, P = 0.001), improved significantly, while 13 patients (65%) reported discontinuation of PPI. Total acid exposure time (5.84 ± 4.63% to 2.83 ± 3.41%, P = 0.024) and number of reflux episodes (73.05 ± 19.34 to 37.55 ± 22.71, P < 0.001) decreased significantly after ARMA. Improved esophagogastric junction (EGJ) barrier function, including increased lower esophageal sphincter resting pressure (13.89 ± 10.78 mmHg to 21.68 ± 11.5 mmHg, P = 0.034), 4-second integrated relaxation pressure (5.75 ± 6.42 mmHg to 9.99 ± 5.89 mmHg, P = 0.020), and EGJ-contractile integral(16.42 ± 16.93 mmHg · cm to 31.95 ± 21.25 mmHg · cm, P = 0.016), were observed. Esophageal body contractility also increased significantly (distal contractile integral, 966.85 ± 845.84 mmHg · s · cm to 1198.8 ± 811.74 mmHg · s · cm, P = 0.023). Patients with symptom improvement had better pre-AMRA esophageal body contractility.
Conclusions
ARMA effectively improves symptoms and reflux burden, EGJ barrier function, and esophageal body contractility in patients with PPIdependent GERD during short-term evaluation. Longer follow-up to clarify the sustainability of ARMA is needed.
8.Effect of Anti-reflux Mucosal Ablation on Esophageal Motility in Patients With Gastroesophageal Reflux Disease: A Study Based on High-resolution Impedance Manometry
Chien-Chuan CHEN ; Chu-Kuang CHOU ; Ming-Ching YUAN ; Kun-Feng TSAI ; Jia-Feng WU ; Wei-Chi LIAO ; Han-Mo CHIU ; Hsiu-Po WANG ; Ming-Shiang WU ; Ping-Huei TSENG
Journal of Neurogastroenterology and Motility 2025;31(1):75-85
Background/Aims:
Anti-reflux mucosal ablation (ARMA) is a promising endoscopic intervention for proton pump inhibitor (PPI)-dependent gastroesophageal reflux disease (GERD). However, the effect of ARMA on esophageal motility remains unclear.
Methods:
Twenty patients with PPI-dependent GERD receiving ARMA were prospectively enrolled. Comprehensive self-report symptom questionnaires, endoscopy, 24-hour impedance-pH monitoring, and high-resolution impedance manometry were performed and analyzed before and 3 months after ARMA.
Results:
All ARMA procedures were performed successfully. Symptom scores, including GerdQ (11.16 ± 2.67 to 9.11 ± 2.64, P = 0.026) and reflux symptom index (11.63 ± 5.62 to 6.11 ± 3.86, P = 0.001), improved significantly, while 13 patients (65%) reported discontinuation of PPI. Total acid exposure time (5.84 ± 4.63% to 2.83 ± 3.41%, P = 0.024) and number of reflux episodes (73.05 ± 19.34 to 37.55 ± 22.71, P < 0.001) decreased significantly after ARMA. Improved esophagogastric junction (EGJ) barrier function, including increased lower esophageal sphincter resting pressure (13.89 ± 10.78 mmHg to 21.68 ± 11.5 mmHg, P = 0.034), 4-second integrated relaxation pressure (5.75 ± 6.42 mmHg to 9.99 ± 5.89 mmHg, P = 0.020), and EGJ-contractile integral(16.42 ± 16.93 mmHg · cm to 31.95 ± 21.25 mmHg · cm, P = 0.016), were observed. Esophageal body contractility also increased significantly (distal contractile integral, 966.85 ± 845.84 mmHg · s · cm to 1198.8 ± 811.74 mmHg · s · cm, P = 0.023). Patients with symptom improvement had better pre-AMRA esophageal body contractility.
Conclusions
ARMA effectively improves symptoms and reflux burden, EGJ barrier function, and esophageal body contractility in patients with PPIdependent GERD during short-term evaluation. Longer follow-up to clarify the sustainability of ARMA is needed.
9.In-room cytologic evaluation by trained endosonographer for determination of procedure end in endoscopic ultrasound-guided fine needle biopsy of solid pancreatic lesions: a prospective study in Taiwan
Weng-Fai WONG ; Yu-Ting KUO ; Wern-Cherng CHENG ; Chia-Tung SHUN ; Ming-Lun HAN ; Chieh-Chang CHEN ; Hsiu-Po WANG
Clinical Endoscopy 2025;58(3):465-473
Background/Aims:
Endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) is an essential tool for tissue acquisition in solid pancreatic tumors. Rapid on-site evaluation (ROSE) by cytologists ensures diagnostic accuracy. However, the universal application of the ROSE is limited by its availability. Therefore, we aimed to investigate the feasibility of determining the end of the procedure based on the results of in-room cytological evaluation by trained endosonographers (IRCETE).
Methods:
A training course focusing on the cytological interpretation of common pancreatic tumors was provided to the three endosonographers. After training, the decision to terminate EUS-FNB was made based on IRCETE results. The diagnostic accuracy, concordance rate of diagnostic categories, and sample adequacy were compared with those determined by board-certified cytologists and macroscopic on-site evaluation (MOSE).
Results:
We enrolled 65 patients with solid pancreatic tumors, most of whom were malignant (86.2%). The diagnostic accuracy was 90.8% when the end of the procedure was determined based on IRCETE, compared to 87.7% and 98.5% when determined by MOSE and cytologists, respectively (p=0.060). Based on the cytologists’ results, the accuracy of IRCETE in diagnostic category interpretation was 97.3%.
Conclusions
In the absence of ROSE, IRCETE can serve as a supplementary alternative to MOSE in determining the end of tissue sampling with a high accuracy rate.
10.Glucocorticoid Discontinuation in Patients with Rheumatoid Arthritis under Background of Chinese Medicine: Challenges and Potentials Coexist.
Chuan-Hui YAO ; Chi ZHANG ; Meng-Ge SONG ; Cong-Min XIA ; Tian CHANG ; Xie-Li MA ; Wei-Xiang LIU ; Zi-Xia LIU ; Jia-Meng LIU ; Xiao-Po TANG ; Ying LIU ; Jian LIU ; Jiang-Yun PENG ; Dong-Yi HE ; Qing-Chun HUANG ; Ming-Li GAO ; Jian-Ping YU ; Wei LIU ; Jian-Yong ZHANG ; Yue-Lan ZHU ; Xiu-Juan HOU ; Hai-Dong WANG ; Yong-Fei FANG ; Yue WANG ; Yin SU ; Xin-Ping TIAN ; Ai-Ping LYU ; Xun GONG ; Quan JIANG
Chinese journal of integrative medicine 2025;31(7):581-589
OBJECTIVE:
To evaluate the dynamic changes of glucocorticoid (GC) dose and the feasibility of GC discontinuation in rheumatoid arthritis (RA) patients under the background of Chinese medicine (CM).
METHODS:
This multicenter retrospective cohort study included 1,196 RA patients enrolled in the China Rheumatoid Arthritis Registry of Patients with Chinese Medicine (CERTAIN) from September 1, 2019 to December 4, 2023, who initiated GC therapy. Participants were divided into the Western medicine (WM) and integrative medicine (IM, combination of CM and WM) groups based on medication regimen. Follow-up was performed at least every 3 months to assess dynamic changes in GC dose. Changes in GC dose were analyzed by generalized estimator equation, the probability of GC discontinuation was assessed using Kaplan-Meier curve, and predictors of GC discontinuation were analyzed by Cox regression. Patients with <12 months of follow-up were excluded for the sensitivity analysis.
RESULTS:
Among 1,196 patients (85.4% female; median age 56.4 years), 880 (73.6%) received IM. Over a median 12-month follow-up, 34.3% (410 cases) discontinued GC, with significantly higher rates in the IM group (40.8% vs. 16.1% in WM; P<0.05). GC dose declined progressively, with IM patients demonstrating faster reductions (median 3.75 mg vs. 5.00 mg in WM at 12 months; P<0.05). Multivariate Cox analysis identified age <60 years [P<0.001, hazard ratios (HR)=2.142, 95% confidence interval (CI): 1.523-3.012], IM therapy (P=0.001, HR=2.175, 95% CI: 1.369-3.456), baseline GC dose ⩽7.5 mg (P=0.003, HR=1.637, 95% CI: 1.177-2.275), and absence of non-steroidal anti-inflammatory drugs use (P=0.001, HR=2.546, 95% CI: 1.432-4.527) as significant predictors of GC discontinuation. Sensitivity analysis (545 cases) confirmed these findings.
CONCLUSIONS
RA patients receiving CM face difficulties in following guideline-recommended GC discontinuation protocols. IM can promote GC discontinuation and is a promising strategy to reduce GC dependency in RA management. (Trial registration: ClinicalTrials.gov, No. NCT05219214).
Adult
;
Aged
;
Female
;
Humans
;
Male
;
Middle Aged
;
Arthritis, Rheumatoid/drug therapy*
;
Glucocorticoids/therapeutic use*
;
Medicine, Chinese Traditional
;
Retrospective Studies

Result Analysis
Print
Save
E-mail