1.Phase changes and quantity-quality transfer of raw material, calcined decoction pieces, and standard decoction of Ostreae Concha (Ostrea rivularis).
Hong-Yi ZHANG ; Jing-Wei ZHOU ; Jia-Wen LIU ; Wen-Bo FEI ; Shi-Ru HUANG ; Yu-Mei CHEN ; Chong-Yang LI ; Fei-Fei LI ; Qiao-Ling MA ; Fu WANG ; Yuan HU ; You-Ping LIU ; Shi-Lin CHEN ; Lin CHEN ; Hong-Ping CHEN
China Journal of Chinese Materia Medica 2025;50(5):1209-1223
The phase changes and quantity-quality transfer of 17 batches of Ostreae Concha(Ostrea rivularis) during the raw material-calcined decoction pieces-standard decoction process were analyzed. The content of calcium carbonate(CaCO_3), the main component, was determined by chemical titration, and the extract yield and transfer rate were calculated. The CaCO_3 content in the raw material, calcined decoction pieces, and standard decoction was 94.39%-98.80%, 95.03%-99.22%, and 84.58%-90.47%, respectively. The process of raw material to calcined decoction pieces showed the yield range of 96.85% to 98.55% and the CaCO_3 transfer rate range of 96.92% to 99.27%. The process of calcined decoction pieces to standard decoction showed the extract yield range of 2.86% to 5.48% and the CaCO_3 transfer rate range of 2.59% to 5.13%. The results of X-ray fluorescence(XRF) assay showed that the raw material, calcined decoction pieces, and standard decoction mainly contained Ca, Na, Mg, Si, Br, Cl, Al, Fe, Cr, Mn, and K. The chemometric results showed an increase in the relative content of Cr, Fe, and Si from raw material to calcined decoction pieces and an increase in the relative content of Mg, Al, Br, K, Cl, and Na from calcined decoction pieces to standard decoction. X-ray diffraction(XRD) was employed to establish XRD characteristic patterns of the raw material, calcined decoction pieces, and standard decoction. The XRD results showed that the main phase of all three was calcite, and no transformation of crystalline form or generation of new phase was observed. Fourier transform infrared spectroscopy(FTIR) was employed to establish the FTIR characteristic spectra of the raw material, calcined decoction pieces, and standard decoction. The FTIR results showed that the raw material had internal vibrations of O-H, C-H, C=O, C-O, and CO■ groups. Due to the loss of organic matter components after calcination, no information about the vibrations of C-H, C=O, and C-O groups was observed in the spectra of calcined decoction pieces and standard decoction. In summary, this study elucidated the quantity-quality transfer and phase changes in the raw material-calcined decoction pieces-standard decoction process by determining the CaCO_3 content, calculating the extract yield and transfer rate, and comparing the element changes, FTIR characteristic spectra, and XRD characteristic pattern. The results were reasonable and reliable, laying a foundation for the subsequent process research and quality control of the formula granules of calcined Ostreae Concha(O. rivularis Gould), and providing ideas and methods for the quality control of the whole process of raw material-decoction pieces-standard decoction-formula granules of Ostreae Concha and other testacean traditional Chinese medicine.
Drugs, Chinese Herbal/isolation & purification*
;
Calcium Carbonate/analysis*
;
Quality Control
2.Processing technology of calcined Magnetitum based on concept of QbD and its XRD characteristic spectra.
De-Wen ZENG ; Jing-Wei ZHOU ; Tian-Xing HE ; Yu-Mei CHEN ; Huan-Huan XU ; Jian FENG ; Yue YANG ; Xin CHEN ; Jia-Liang ZOU ; Lin CHEN ; Hong-Ping CHEN ; Shi-Lin CHEN ; Yuan HU ; You-Ping LIU
China Journal of Chinese Materia Medica 2025;50(9):2391-2403
Guided by the concept of quality by design(QbD), this study optimizes the calcination and quenching process of calcined Magnetitum and establishes the XRD characteristic spectra of calcined Magnetitum, providing a scientific basis for the formulation of quality standards. Based on the processing methods and quality requirements of Magnetitum in the Chinese Pharmacopoeia, the critical process parameters(CPPs) identified were calcination temperature, calcination time, particle size, laying thickness, and the number of vinegar quenching cycles. The critical quality attributes(CQAs) included Fe mass fraction, Fe~(2+) dissolution, and surface color. The weight coefficients were determined by combining Analytic Hierarchy Process(AHP) and the criteria importance though intercrieria correlation(CRITIC) method, and the calcination process was optimized using orthogonal experimentation. Surface color was selected as a CQA, and based on the principle of color value, the surface color of calcined Magnetitum was objectively quantified. The vinegar quenching process was then optimized to determine the best processing conditions. X-ray diffraction(XRD) was used to establish the characteristic spectra of calcined Magnetitum, and methods such as similarity evaluation, cluster analysis, and orthogonal partial least squares-discriminant analysis(OPLS-DA) were used to evaluate the quality of the spectra. The optimized calcined Magnetitum preparation process was found to be calcination at 750 ℃ for 1 h, with a laying thickness of 4 cm, a particle size of 0.4-0.8 cm, and one vinegar quenching cycle(Magnetitum-vinegar ratio 10∶3), which was stable and feasible. The XRD characteristic spectra analysis method, featuring 9 common peaks as fingerprint information, was established. The average correlation coefficient ranged from 0.839 5-0.988 1, and the average angle cosine ranged from 0.914 4 to 0.995 6, indicating good similarity. Cluster analysis results showed that Magnetitum and calcined Magnetitum could be grouped together, with similar compositions. OPLS-DA discriminant analysis identified three key characteristic peaks, with Fe_2O_3 being the distinguishing component between the two. The final optimized processing method is stable and feasible, and the XRD characteristic spectra of calcined Magnetitum was initially established, providing a reference for subsequent quality control and the formulation of quality standards for calcined Magnetitum.
X-Ray Diffraction/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Quality Control
;
Particle Size
3.Early clinical outcomes of 3D-printed individualised customised prostheses in hip revision combined severe bone defect.
Hong-Ping WANG ; Ming-You WANG ; Xiao-Qin YANG ; Zhuo-Dong TANG ; Xun-Zhou SONG ; Yu-Ping LAN
China Journal of Orthopaedics and Traumatology 2025;38(2):163-169
OBJECTIVE:
To explore the early clinical outcomes of 3D printed individualised customised prostheses for in hip revision in patients with combined severe bone defects.
METHODS:
Twenty-two patients from January 2021 to May 2023 underwent hip revision using 3D printed personalised customised prostheses were retrospective analyzed, including 10 males and 12 females, age 28 to 78 with a mean of (58.9±12.8) years old. All of patients were combined with severe bone defects (Parprosky type Ⅲ). Among of them, 9 patients had periprosthetic infections and 13 patients had aseptic prosthesis loosening. All patients were treated with a 3D printed personalised prosthesis protocol, patients with the periprosthetic infection received a second stage revision after infection control. The operation time, preoperative waiting time, intraoperative and postoperative complications were recorded, and the clinical efficacy were evaluated at the final follow-up using the visual analogue scale (VAS) for pain, the Harris hip score.
RESULTS:
One patient was lost to follow-up and the remaining 21 patients were followed up for 10 to 15 with a mean of (12.91±1.44) months after surgery. All patients completed surgery as planned, with an operative time of 135 to 390 with a mean of (165.4±39.3) minutes and a preoperative waiting time of 7 to 16 with a mean of (10.5±3.3) days. Regarding patient complications:one patient had a severe intraoperative periprosthetic femoral fracture due to the combination of severe osteoporosis; one patient had an intraoperative greater trochanteric femur fracture. At the latest follow-up, all patients had good position of the custom-made prosthesis and no loosening of the prosthesis;all patients had good wound healing and no local redness or swelling. The total Harris score at the final follow-up (85.86±7.04) was significantly improved compared to the preoperative (44.86±2.36), P<0.001. The VAS at the last follow-up (2.19±0.87) was significantly improved compared with preoperative (7.41±0.96), P<0.001.
CONCLUSION
The clinical efficacy of 3D-printed personalised customised prosthesis in combined severe bone defect hip revision is satisfactory, but due to the increased preoperative waiting time of the patients and certain risks, certain indications should be mastered when applying in the clinic.
Humans
;
Male
;
Female
;
Printing, Three-Dimensional
;
Middle Aged
;
Aged
;
Adult
;
Retrospective Studies
;
Hip Prosthesis
;
Arthroplasty, Replacement, Hip
;
Reoperation
;
Prosthesis Design
;
Treatment Outcome
4.Comparison of application and efficacy of domestic HURWA and imported Smith & Nephew Cori robots in total knee arthroplasty.
Ming-You WANG ; Zhuo-Dong TANG ; Yu-Ping LAN ; Heng XIAO ; Ming-Li WANG ; Xun-Zhou SONG ; Hong-Ping WANG
China Journal of Orthopaedics and Traumatology 2025;38(10):1027-1036
OBJECTIVE:
Investigation on the clinical application of HURWA robot and Smith & Nephew Cori robot in total knee arthroplasty(TKA).
METHODS:
A retrospective analysis was performed on 84 patients with knee osteoarthritis who underwent robotic-assisted TKA (RATKA) between June 2023 and March 2025. According to the different robotic systems used, the patients were divided into the domestic HUARUN robotic-assisted total knee arthroplasty group (HRATKA group) and the Smith & Nephew Cori robotic-assisted total knee arthroplasty group (CRATKA group). There were 42 patients in the HRATKA group, including 16 males and 26 females; the age ranged from 56 to 73 years old, with an average of (64.70±8.30) years old;the body mass index (BMI) was (25.10±2.30) kg·m-2;21 cases were on the right side and 21 cases on the left side;in terms of Kellgren-Lawrence(K-L) classification, there were 15 cases of Grade Ⅲ and 27 cases of Grade Ⅳ;the disease duration ranged from 3 to 25 years, with an average of (15.5±7.5) years. The CRATKA group also included 42 patients, with 14 males and 28 females;the age ranged from 58 to 74 years old, with an average of (65.60±7.50) years old;the BMI was (24.50±2.70) kg·m-2; 20 cases were on the right side and 22 cases on the left side;regarding K-L classification, there were 11 cases of Grade Ⅲ and 31 cases of Grade Ⅳ;the disease duration ranged from 2 to 26 years, with an average of (16.5±8.8) years. Collect general data of all patients, including age, gender, height, weight, surgical site, K-L classification, incision length, and operation time. To evaluate prosthesis position, compare the frontal tibia component (FTC) angle, lateral femoral component (LFC) angle, lateral tibia component (LTC) angle, and frontal femoral component angle between the two groups of patients after surgery. Measure the deviation of the hip-knee-ankle (HKA) angle to assess lower limb alignment. Additionally, compare the following indicators between the two groups:Knee Society Score (KSS), Visual Analogue Scale (VAS) for pain, knee range of motion (ROM), hemoglobin (HB) level, hematocrit (HCT) level, complication rate, and in-hospital satisfaction.
RESULTS:
All patients successfully completed the surgery as scheduled, and all were followed up after the operation. The follow-up period ranged from 5 to 17 months with an average of (11.2±6.1) months. There were 4 cases of venous thrombosis in the HRATKA group and 3 cases in the CRATKA group;each group had 2 cases of wound exudation. No mechanical-related complications, pulmonary embolism, or other severe complications occurred. Comparison of the incision length and hospital stay between the HRATKA group and the CRATKA group showed no statistically significant difference (P>0.05). The operation time in the HRATKA group was (96.80±7.10) minutes, which was longer than that in the CRATKA group (90.10±8.80) minutes, and the difference was statistically significant (P<0.05). In the HRATKA group, the HKA angle was (178.93±1.11) degree, the FFC angle was (89.00±0.91)°, and the LFC angle was (7.31±2.17) degree;the corresponding values in the CRATKA group were (178.05±1.34)°, (87.88±1.74)°, and (10.60±2.84) degree respectively. The differences in these three indicators between the two groups were all statistically significant (P<0.05). However, there were no statistically significant differences in the FTC angle or LTC angle between the two groups (P>0.05). There was also no statistically significant difference in the total perioperative blood loss between the two groups (P>0.05). At 3 days after surgery, the VAS score for movement in the HRATKA group (5.95±1.45) points was higher than that in the CRATKA group (4.50±0.97) points, with a statistically significant difference (P<0.05);at 90 days after surgery, there was no statistically significant difference in the movement VAS score between the two groups (P>0.05). Additionally, no statistically significant differences were observed between the two groups in the KSS, ROM at 3 and 90 days after surgery, or satisfaction degree during hospitalization (all P>0.05).
CONCLUSION
The domestic HURWA robot demonstrates excellent performance in osteotomy efficiency and lower limb alignment recovery. The Smith & Nephew Cori robot has a significant advantage in soft tissue assessment and joint stability optimization. Both robotic systems offer high-quality surgical treatments that significantly improve short-term knee function.
Humans
;
Male
;
Female
;
Arthroplasty, Replacement, Knee/instrumentation*
;
Aged
;
Middle Aged
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Osteoarthritis, Knee/surgery*
5.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
6.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
7.Establishment of quantitative models for effective components in Yishen Xiezhuo Mixture
Zi-fang FENG ; Min-min HU ; Xiao-wei CHEN ; Wen-ming ZHANG ; Li-hong GU ; Ping QIN ; Yi PENG ; Zhen-hua BIAN ; Qing-you YANG ; Tu-lin LU
Chinese Traditional Patent Medicine 2025;47(10):3177-3184
AIM To establish the quantitative models for gallic acid,mononucleoside,loganin,resveratrol,and rhein in Yishen Xiezhuo Mixture.METHODS HPLC was adopted in the content determination of various effective components,after which the near-infrared spectroscopy(NIRS)data were collected in 128 batches of samples and pretreatment was conducted,competitive adaptive reweighting sampling(CARS)algorithm was used for screening wavelength,partial least square method(PLS)regression analysis was performed.RESULTS There were no significant differences between the predicted values obtained by PLS models and measured values obtained by HPLC for various effective components(P>0.05).CONCLUSION The quantitative models established by NIRS combined with chemometrics display good predictive performance,which can be used for the rapid determination of effective components in Yishen Xiezhuo Mixture,and provide a reference for the rapid monitoring of other traditional Chinese medicine preparations in production processes.
8.Establishment of quantitative models for effective components in Yishen Xiezhuo Mixture
Zi-fang FENG ; Min-min HU ; Xiao-wei CHEN ; Wen-ming ZHANG ; Li-hong GU ; Ping QIN ; Yi PENG ; Zhen-hua BIAN ; Qing-you YANG ; Tu-lin LU
Chinese Traditional Patent Medicine 2025;47(10):3177-3184
AIM To establish the quantitative models for gallic acid,mononucleoside,loganin,resveratrol,and rhein in Yishen Xiezhuo Mixture.METHODS HPLC was adopted in the content determination of various effective components,after which the near-infrared spectroscopy(NIRS)data were collected in 128 batches of samples and pretreatment was conducted,competitive adaptive reweighting sampling(CARS)algorithm was used for screening wavelength,partial least square method(PLS)regression analysis was performed.RESULTS There were no significant differences between the predicted values obtained by PLS models and measured values obtained by HPLC for various effective components(P>0.05).CONCLUSION The quantitative models established by NIRS combined with chemometrics display good predictive performance,which can be used for the rapid determination of effective components in Yishen Xiezhuo Mixture,and provide a reference for the rapid monitoring of other traditional Chinese medicine preparations in production processes.
9.Comparison of anterior lateral ligament reconstruction and anterior lateral complex repair in the treatment of anterior cruciate ligament combined with anterior lateral ligament injury with high-grade pivot shift.
Xue-Feng JIA ; Qing-Hua WU ; Tong-Bo DENG ; Xiao-Zhen SHEN ; Jian-Ping YE ; He FANG ; Rong-Chang ZHOU ; Yang CAO ; You-Fen CHEN ; Qi-Ning YANG ; Guo-Hong XU
China Journal of Orthopaedics and Traumatology 2024;37(11):1101-1106
OBJECTIVE:
To retrospectively analyze the clinical efficacy of anterior cruciate ligament (ACL) reconstruction combined with anterolateral complex repair and ACL reconstruction combined with ALL reconstruction in the treatment of anterior cruciate ligament injuries with high-grade pivot shift.
METHODS:
From January 2018 to June 2022, 49 patients combined ACL and ALL injuries with high-grade pivot shift were retrospectively studied from three hospitals, 29 of them underwent ACL reconstruction with anterolateral complex repair (repair group), including 23 males and 6 females with an average age of (27.5±4.8) years old, ranged from 20 to 37 years old;the injured sides were 13 on the left and 16 on the right, and 11 patients were suffered with meniscus injury. The other 20 patients underwent ACL and ALL reconstruction (reconstruction group) including 17 males and 3 females with the mean age of (27.1±4.5) years old, ranged from 20 to 38 years old;the injured sides were 8 on the left and 12 on the right, and 6 patients were suffered with meniscus injury. Knee stability (pivot shift test, KT-2000), range of motion, knee function (Lysholm scoring scale, Cincinnati sports activity scale (CSAS) scoring scale, and Tegner activity level score between two groups were compared.
RESULTS:
A total of 49 patients were followed up, the repair group receiving 13 to 20(15.3±1.8) months and the reconstruction group receiving 12 to 21(16.0±2.2) months. There was no statistically significant difference in the preoperative pivot shift test grading distribution between two groups (P>0.05). At the last postoperative follow-up, there were 24 patients with grade 0 and 5 patients with grade 1 in the repair group, and there were 18 patients with grade 0 and 2 patients with grade 1 in the reconstruction group, there is no significant difference in the distribution of axial shift test grading between two groups(P>0.05). The preoperative KT-2000 tibial displacement of two groups were (9.39±0.77) mm (repair group) and (9.14±0.78) mm (reconstruction group) respectively, with no statistically significant difference (P>0.05). At the final postoperative follow-up, there were 24 patients with KT-2000 tibial displacement <3 mm and 5 patients with 3 to 5 mm in the repair group, while 18 patients with <3 mm and 2 patients with 3 to 5 mm in the reconstruction group, KT-2000 tibial displacement distribution of two groups was no significant difference (P>0.05), but the KT-2000 tibial displacement in the reconstruction group (1.30±0.86) mm was significantly smaller than that in the repair group (1.99±1.11) mm (P<0.05). The final postoperative follow-up range of motion of the contralateral side knee between two groups was no significant difference (P>0.05). The range of motion of the suffering knee in the repair group was less than that in the reconstruction group (P<0.05). There was no significant difference in preoperative Lysholm and CSAS scores between two groups (P>0.05). At the final postoperative follow-up, both groups showed significant improvement in Lysholm and CSAS scores, while the Lysholm and CSAS scores of the reconstruction group were better than those of the repair group, and the difference was statistically significant (P<0.05). Significant differences was found in Tegner scores between two groups, which 16 patients in the repair group returned to their pre-injury activity level, and 17 patients in the reconstruction group returned to their pre-injury level (P<0.05).
CONCLUSION
Compared to anterolateral complex repair, combined ACL and ALL reconstruction in the treatment of ACL injuries with high-grade pivot shift results in better knee joint function and stability. This is advantageous in reducing the risk of ACL reconstruction failure.
Humans
;
Male
;
Female
;
Adult
;
Anterior Cruciate Ligament Reconstruction/methods*
;
Anterior Cruciate Ligament Injuries/surgery*
;
Young Adult
;
Retrospective Studies
;
Anterior Cruciate Ligament/surgery*
;
Range of Motion, Articular
10.Characteristics and treatment measures of cages displacement after oblique lateral interbody fusion.
Zhong-You ZENG ; Xing ZHAO ; Deng-Wei HE ; Yu ZHANG ; Ping-Quan CHEN ; Hong-Fei WU ; Wei YU ; Yong-Xing SONG ; Shun-Wu FAN ; Fei PEI ; Shi-Yang FAN ; Guo-Hao SONG ; Hai-Feng WANG
China Journal of Orthopaedics and Traumatology 2024;37(12):1164-1172
OBJECTIVE:
To explore characteristics, management strategies and preventive measures of fusion device displacement after oblique lateral interbody fusion (OLIF) in treating lumbar lesions.
METHODS:
The clinical data of 12 patients with fusion device displacement after OLIF for lumbar lesions in 4 medical centers from October 2014 to December 2018 were retrospectively analyzed, including 4 males and 8 females, aged from 53 to 81 years old;2 patients with lumbar disc degeneration, 4 patients with lumbar spinal stenosis, 3 patients with lumbar degenerative spondylolisthesis and 3 patients with lumbar degenerative kyphosis;preoperative dual-energy X-ray bone mineral density (BMD) was detected in 1 patient with T-value > -1 SD, 5 patients with T-value >-1~-2.5 SD, and 6 patients with T-value <-2.5 SD;9 patients with single-segment fusion, 1 patient with 2-segment fusion, and 2 patients with 3-segment fusion;standalone OLIF was performed in 9 patients and OLIF combined with posterior pedicle screws in 3 patients. Visual analogue scale (VAS) and Oswestry disability index (ODI) were used to evaluate low back pain and lumbar function recovery at the time of fusion graft displacement and at the latest follow-up, respectively. In addition, according to imaging results during follow-up, the fusion device subsidence or redisplacement, loosening or fracture of internal fixation, and interbody fusion were observed, and the changes in the height of interbody space on the segment with fusion device displacement were measured and compared.
RESULTS:
There were no necrosis or infection in skin incision of 10 patients after reoperation, and 12 patients were followed up for 12 to 48 months. VAS for low back pain decreased from 3 to 8 points at the time of fusion device displacement to 0 to 2 points at the latest follow-up. ODI recovered from 31% to 51% at the time of fusion transfer to 5% to 13% at the latest follow-up. There was no loosening or fracture of the pedicle screw system during follow-up. All 11 patients with bone grafting with fusion apparatus had fusion apparatus subsidence and no further displacement of fusion apparatus. The vertebral space height recovered from 9.0 to 12.7 mm at the time of fusion graft displacement to 8.0 to 11.8 mm at the latest follow-up. Interbody fusion was obtained in all patients except 1 with no imaging results at the latest follow-up.
CONCLUSION
OLIF could be used for fusion of lumbar lesions, and there is a risk of fusion organ displacement after operation, especially in cases of bone loss or osteoporosis before surgery, end-plate injury during surgery, and Stand-alone mode, and most of them occur within 3 months after operation. Surgery is required for the transposition of the fusion apparatus in the Stand-alone OLIF mode during the primary operation. Although good clinical results could be obtained by timely detection and accurate treatment, it is still necessary to emphasize the precise selection of cases before operation, the appropriate application of OLIF, and precise operation during operation to prevent displacement of fusion device.
Humans
;
Spinal Fusion/instrumentation*
;
Female
;
Male
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Lumbar Vertebrae/surgery*
;
Retrospective Studies
;
Pedicle Screws

Result Analysis
Print
Save
E-mail