1.Analysis of the effect of dosimeter wearing position on effective dose estimation among interventional radiology workers
Xuanrong ZHANG ; Wen GUO ; Xian XUE ; Pin GAO ; Kaiyi WANG ; Xuan ZHANG ; Yanqiu DING ; Xiao LUO ; Wenfang MENG ; Jun CHAO
Chinese Journal of Radiological Health 2025;34(5):687-694
Objective To evaluate the influence of the wearing position of dosimeters outside lead aprons on effective dose estimation for interventional radiology workers, analyze the differences between single and double dosimeter methods in effective dose estimation, and provide a reference for the personal dose monitoring of interventional radiology workers. Methods This study employed a combined approach of on-site monitoring and Monte Carlo simulation to evaluate the impact of the wearing position of dosimeters outside lead aprons on effective dose estimation, as well as the differences between effective doses measured using single and double dosimeters. Interventional radiology workers wore dosimeters at three positions: the neck outside the lead collar, the left chest outside the lead apron, and inside the lead apron. Effective doses were estimated using the single and double dosimeter methods specified in GBZ 128-2019 Specifications for individual monitoring of occupational external exposure, and the impact of different wearing positions on the estimation results was compared. Geant4 Monte Carlo simulations were used to model dose distributions at the neck outside the lead collar and at the left chest outside the lead apron for operators performing cardiovascular interventions under tube voltages of 70, 80, 90, and 100 kVp and exposure angles of posteroanterior (PA), anteroposterior (AP), and left anterior oblique 45° (LAO45°) positions. The study assessed the impact of dosimeter wearing position on effective dose estimation. Results Monte Carlo simulations demonstrated that neck doses consistently exceeded left chest doses across different tube voltages and exposure angles, with neck-to-chest dose ratios of 0.80-0.90. Under identical tube voltage conditions, AP showed the highest doses, followed by LAO45°, and PA demonstrated the lowest doses. The single and double dosimeter methods exhibited consistent patterns in effective dose estimation. Single dosimeter method generally yielded higher effective doses with relative deviations of 9.9% to 83%, though these deviations decreased under high tube voltages. Field monitoring data indicated that most interventional radiology workers maintained relative deviations between single and double dosimeter calculations below 6%, with neck-to-chest dose ratios of 0.95-1.1. The estimation patterns remained consistent across both methods, though single dosimeter method showed slightly higher results. Conclusion Under PA, AP, or LAO45°, the doses at the neck consistently exceeded those at the left chest. Therefore, when wearing lead protective equipment, the dosimeter should be properly positioned at the neck outside the lead collar to accurately reflect the radiation doses of surgeons. Some interventional radiology workers improperly positioned the dosimeter (intended at the neck outside the lead collar) at the left chest outside the lead apron, and this may result in an underestimation of the effective dose.
2.An Analysis of Clinical Trial Registration Characteristics for Traditional Chinese Medicine in the Treatment of Overweight/Obesity
Rumeng MEI ; Ningzi ZANG ; Chengjun GONG ; Tianshu GAO ; Xiao YANG ; Libin ZHAN ; Pin LI
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(10):2999-3009
Objective To systematically review and analyze the characteristics and current status of registered clinical trials on Traditional Chinese Medicine(TCM)for the prevention and treatment of overweight/obesity.Methods We conducted a comprehensive search of two primary clinical trial registration platforms,the Chinese Clinical Trial Registry and ClinicalTrials.gov,to extract registered information on TCM interventions for overweight/obesity.The search period spanned from the establishment of each registry to December 31,2024.Statistical analysis was performed on the extracted registration data.Results A total of 226 clinical studies were included,with a cumulative sample size of 25165 participants.The annual registration volume exhibited a significant upward trend.The majority of studies were interventional in design,with primary outcome measures focusing on anthropometric and metabolic indicators.Notably,only two trials fully met the international standards for clinical trial registration as outlined by the World Health Organization(WHO).Conclusion A quality assessment of the overall registration data revealed that the quality of trial registrations remains suboptimal.Issues such as inadequate standardization,transparency,and comprehensiveness were identified.Additionally,the geographical distribution of registered trials was uneven,and there is an urgent need to refine outcome measures related to TCM syndrome differentiation.
3.Research Progress and Evaluation of Animal Models for the Study of Obesity and Its Associated Complications
Ziyuan SONG ; Libin ZHAN ; Ningzi ZANG ; Tianshu GAO ; Chengjun GONG ; Rumeng MEI ; Xuelian LI ; Pin LI
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(9):2687-2698
With the development of society,the incidence of obesity has increased year by year in recent years,which has seriously jeopardized public health and safety,and has been a hot spot in the field of endocrine research.At the same time,obesity is also an important cause of a variety of metabolic diseases,such as metabolic syndrome,pre-diabetes,hypertension and polycystic ovary syndrome and other diseases,but the etiology and mechanism of obesity have not been completely clear,and basic research on obesity of traditional Chinese and western medicine still needs to be widely carried out.In this paper,animal models of obesity and its complications will be comprehensively summarized,and the model principles will be elaborated in combination with TCM syndromes and western medicine mechanisms,and evaluate their merits and demerits,so as to provide references for the selection of reasonable animal models for relevant experimental studies of obesity.
4.Analysis of results of radiation detection capability intercomparison between disease control and prevention institutions at provincial, municpal and county levels in China from 2022 to 2024
Peize TANG ; Xiaorui WANG ; Zhu YAO ; Hua ZHAO ; Pin GAO ; Tianjiao JIA ; Kaiyi WANG ; Xuesong QI
Chinese Journal of Radiological Medicine and Protection 2025;45(8):724-730
Objective:To analyze the intercomparision result of personal dose monitoring and gross alpha/beta detection capability between the disease control and prevention institutions at provincial, municpal and county levels during 2022-2024, in order to provide a reference for radiation detection capability and policy making of these institutions in China.Methods:Data on personal dose monitoring and gross alpha/beta detection, obtanied from the 2022-2024 radiation detection capability intercomparison between the disease control and prevention institutions at different levels, were recorded. Both the qualification rates (including excellence) and excellence rates of all the institutions at all evels from 2022 to 2024 were analyzed using SPSS 22.0.Results:From 2022 to 2024, the number of participating institutions at all levels showed an overall upward trend, increasing from 262 to 430, with particularly notable growth at the municipal level. In the 2024 gross α/β detection capability intercomparison, the non-qualification rate in municipal-level institutions was significantly higher than in county-level institutions ( χ2=10.53, P < 0.05). The qualification rate (including excellence) of the municipal-level gross alpha/beta detection in 2022 and 2024 were lower than in 2023( χ2=29.93, P < 0.01). Among all regions, the 2024 personal dose monitoring intercomparison result showed that the qualification rate (including excellence) in East China was higher than in Southwest and Northwest China ( χ2=15.62, P <0.01). East China also outperformed Northwest China ( χ2=16.21, P <0.01). In the 2022 gross alpha/beta detection capability intercomparison, the qualification rate (including excellent performance) in East China and South China was higher than in Northwest China ( χ2=23.76, 11.22, P<0.01). Overall, East China showed relatively higher qualification rate in intercomparison result of both personal dose monitoring and radiation detection (including excellence), while Northwest China showed lower qualification rates (including excellence). Conclusions:Although the radiation detection capability of disease control and prevention institutions at all levels has improved in recent years, there are still insufficience of detection capabilities at some municipal- and county-level laboratories and even unbalance between different regionas. Policy support should prioritize underdeveloped areas, such as municipal- and county-level institutions and the Northwest, and enhance the technical proficiency and quality management of laboratory personnel.
5.An Analysis of Clinical Trial Registration Characteristics for Traditional Chinese Medicine in the Treatment of Overweight/Obesity
Rumeng MEI ; Ningzi ZANG ; Chengjun GONG ; Tianshu GAO ; Xiao YANG ; Libin ZHAN ; Pin LI
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(10):2999-3009
Objective To systematically review and analyze the characteristics and current status of registered clinical trials on Traditional Chinese Medicine(TCM)for the prevention and treatment of overweight/obesity.Methods We conducted a comprehensive search of two primary clinical trial registration platforms,the Chinese Clinical Trial Registry and ClinicalTrials.gov,to extract registered information on TCM interventions for overweight/obesity.The search period spanned from the establishment of each registry to December 31,2024.Statistical analysis was performed on the extracted registration data.Results A total of 226 clinical studies were included,with a cumulative sample size of 25165 participants.The annual registration volume exhibited a significant upward trend.The majority of studies were interventional in design,with primary outcome measures focusing on anthropometric and metabolic indicators.Notably,only two trials fully met the international standards for clinical trial registration as outlined by the World Health Organization(WHO).Conclusion A quality assessment of the overall registration data revealed that the quality of trial registrations remains suboptimal.Issues such as inadequate standardization,transparency,and comprehensiveness were identified.Additionally,the geographical distribution of registered trials was uneven,and there is an urgent need to refine outcome measures related to TCM syndrome differentiation.
6.Construction and validation of prediction models for delayed encephalopathy after acute carbon monoxide poisoning based on machine learning
Yanwu YU ; Yan ZHANG ; Ding YUAN ; Huihui HAO ; Fang YANG ; Hongyi YAN ; Pin JIANG ; Mengnan GUO ; Zhigao XU ; Changhua SUN ; Gaiqin YAN ; Lu CHE ; Jianjun GUO ; Jihong CHEN ; Yan LI ; Yanxia GAO
Chinese Journal of Emergency Medicine 2025;34(10):1403-1409
Objective:s To investigate the risk factors for delayed encephalopathy after acute carbon monoxide poisoning (DEACMP) in patients with acute carbon monoxide poisoning (ACOP) and to develop predictive models based on machine learning algorithms.Methods:Patients with ACOP hospitalized at the First Affiliated Hospital of Zhengzhou University from August 2019 to October 2024 were included, with the occurrence of DEACMP as the outcome measure. The dataset was randomly divided into training and validation sets at a ratio of 7:3. Lasso regression was used to select features influencing the outcome in training sets. Nine machine learning models—including Random Forest (RF), Extreme Gradient Boosting (XGBoost), and Support Vector Machine (SVM)—were constructed. Receiver operating characteristic (ROC) curves were plotted and the area under the curve (AUC) calculated for each model. Calibration curves were used to assess accuracy, and decision curve analysis (DCA) was applied to evaluate clinical utility. The SHapley Additive exPlanations (SHAP) method was employed to visualize and interpret the best-performing model.Results:A total of 264 ACOP patients were included, of whom 54 (20.5%) developed DEACMP. Lasso regression identified eight key feature variables. Based on these factors, predictive models were constructed, showing good AUC stability across the nine machine learning models in both training (0.92–0.99) and validation sets (0.85–0.91). The RF model performed best, with an AUC of 0.99 in the training set and 0.90 in the validation set; its calibration curve and DCA curve also demonstrated excellent performance. SHAP analysis of the RF model revealed the importance ranking of factors from highest to lowest as follows: Glasgow Coma Scale (GCS) score, duration of coma, age, history of coronary heart disease, CK-MB level, monocyte count, diastolic blood pressure (DBP), and drinking history.Conclusions:The RF model exhibited the highest predictive performance for DEACMP occurrence in ACOP patients. The influencing factors, ranked in order of importance from highest to lowest, are as follows: GCS score, duration of coma, age, history of coronary heart disease, CK-MB level, monocyte count, DBP, and drinking history.
7.Traditional Chinese medicine understanding and treatment strategies for hypertension com plicated by chronic low back pain from perspective of kidney deficiency syndrome.
Zheng-Rong LUO ; Yin-Qiu GAO ; Xing-Jiang XIONG ; Pin LYU ; Xiao-Chen YANG
China Journal of Chinese Materia Medica 2025;50(4):1121-1131
In China, the number of chronic pain patients has exceeded 300 million, making chronic pain the third major health problem after tumors and cardiovascular diseases. Particularly concerning is the gradual emergence of hypertension and chronic low back pain as public health problems that threaten public health and increase the global economic burden. Modern research shows that the incidence of coexisting hypertension is higher among patients with chronic low back pain. Additionally, evidence indicates that the use of NSAIDs for pain relief can have adverse effects on blood pressure, and some antihypertensive medications may trigger symptoms of low back pain. Thus, addressing chronic pain in hypertensive patients while stabilizing blood pressure is one of the important research questions in the modern treatment of hypertension among middle-aged and elderly individuals. From ancient to modern traditional Chinese medicine(TCM) theory, kidney deficiency has been regarded as the core pathogenesis of low back pain. Recent clinical practices and literature indicate that kidney deficiency plays a crucial role in the modern pathogenesis of hypertension. Both hypertension and chronic low back pain are closely associated with kidney deficiency in TCM theory, revealing a potential mechanism linking the two conditions. Combining the theories of " kidney-essence-marrow" and " nourishing water to moisten wood", a therapeutic strategy centered on tobifying kidney was proposed, including selecting single drugs with kidney-tonifying effects as well as compound formulations and elaborating modern research evidence. The aim is to achieve stable blood pressure control in hypertension patients with chronic low back pain while providing a new treatment perspective for chronic low back pain. This article systematically elaborates on the understanding of hypertension combined with chronic low back pain from both TCM and modern medicine, as well as the therapeutic strategy involving kidney-tonifying drugs, to offer useful references for clinical practice.
Humans
;
Hypertension/complications*
;
Low Back Pain/complications*
;
Drugs, Chinese Herbal/therapeutic use*
;
Kidney/drug effects*
;
Medicine, Chinese Traditional
;
Chronic Pain/drug therapy*
8.Preliminary design and performance analysis of a wide-energy-spectrum CR-39 individual neutron dosimeter
Jian XU ; Yanqiu DING ; Wen GUO ; Yunyun WU ; Pin GAO ; Kaiyi WANG
Chinese Journal of Radiological Health 2025;34(6):830-836
Objective To preliminarily design a wide-energy-spectrum CR-39 solid-state nuclear track individual neutron dosimeter with different energy sections. Methods The thickness of the converter was optimized using the Monte Carlo SRIM program to broaden the energy range of the dosimeter. The self-made wide-energy-spectrum CR-39 individual neutron dosimeter was calibrated using 241Am-Be, 252Cf, and thermal neutron sources to evaluate its dosimetric performance, including linearity, energy response, and neutron energy resolution. Results The linear correlation coefficient of the measurement system exceeded 0.98. The relative deviations of the energy response were 35.0% for blank section and 42.0% for polyethylene section, falling within the range of −50% to + 100% and meeting the monitoring requirements. The detection sensitivity for thermal neutron dose was 67 137.2 tr·cm−2·mSv−1, and the detection sensitivity for thermal neutron fluence was 0.98 × 10−3 tr·n−1, demonstrating good thermal neutron detection capability. Conclusion The self-made wide-energy-spectrum CR-39 individual neutron dosimeter fundamentally meets the requirements for individual neutron dose monitoring and is suitable for individual neutron dose monitoring in the energy range of thermal neutrons (up to approximately 15 MeV).
9.Investigation and verification of a radiation worker with monitored personal doses exceeding the investigation level
Pin GAO ; Kaiyi WANG ; Yanqiu DING ; Xiaorui WANG ; Peize TANG ; Jingyu LI ; Wen GUO
Chinese Journal of Radiological Health 2025;34(6):841-845
Objective To identify the reasons why the monitored personal doses of radiation worker A in an institution exceeded the investigation level in 2023 and 2024, and remind workers to wear personal dosimeters in a standardized manner in scenarios such as work and business trips to ensure the authenticity and reliability of the monitoring data. Methods A thermoluminescence measurement system was used to read the personal dosimeters worn by radiation workers. Investigations were carried out on personnel whose doses exceeded the investigation level described in the “Specifications for individual monitoring of occupational external exposure” (GBZ 128—2019). The reasons for doses exceeding the investigation level were analyzed using additional dosimeters and conducting on-site experiments. Results In 2023 and 2024, radiation worker A recorded a total of 5 personal dose equivalents exceeding the investigation level (1.23 mSv) over a total of 8 monitoring cycles (each lasting 90 days). Following one cycle where the dose exceeded the investigation level, two additional dosimeters (each for a 30-day cycle) were issued to worker A, revealing readings below the investigation level for the 30-day monitoring cycle (0.41 mSv). The reading for the dosimeter was 2-3 μSv per time when passing through an X-ray security scanner, and approximately 2.10 mSv per time when passing through a computed tomography security scanner. Conclusion Within a 90-day monitoring cycle, a single exposure of a personal dosimeter to a computed tomography security scanner can result in a dose exceeding the investigation level. Radiation workers should avoid placing dosimeters in backpacks or suitcases that pass through computed tomography security scanners during business trips, so as to reduce the impact of security scanner irradiation on personal dose monitoring.
10.Analysis of results of radiation detection capability intercomparison between disease control and prevention institutions at provincial, municpal and county levels in China from 2022 to 2024
Peize TANG ; Xiaorui WANG ; Zhu YAO ; Hua ZHAO ; Pin GAO ; Tianjiao JIA ; Kaiyi WANG ; Xuesong QI
Chinese Journal of Radiological Medicine and Protection 2025;45(8):724-730
Objective:To analyze the intercomparision result of personal dose monitoring and gross alpha/beta detection capability between the disease control and prevention institutions at provincial, municpal and county levels during 2022-2024, in order to provide a reference for radiation detection capability and policy making of these institutions in China.Methods:Data on personal dose monitoring and gross alpha/beta detection, obtanied from the 2022-2024 radiation detection capability intercomparison between the disease control and prevention institutions at different levels, were recorded. Both the qualification rates (including excellence) and excellence rates of all the institutions at all evels from 2022 to 2024 were analyzed using SPSS 22.0.Results:From 2022 to 2024, the number of participating institutions at all levels showed an overall upward trend, increasing from 262 to 430, with particularly notable growth at the municipal level. In the 2024 gross α/β detection capability intercomparison, the non-qualification rate in municipal-level institutions was significantly higher than in county-level institutions ( χ2=10.53, P < 0.05). The qualification rate (including excellence) of the municipal-level gross alpha/beta detection in 2022 and 2024 were lower than in 2023( χ2=29.93, P < 0.01). Among all regions, the 2024 personal dose monitoring intercomparison result showed that the qualification rate (including excellence) in East China was higher than in Southwest and Northwest China ( χ2=15.62, P <0.01). East China also outperformed Northwest China ( χ2=16.21, P <0.01). In the 2022 gross alpha/beta detection capability intercomparison, the qualification rate (including excellent performance) in East China and South China was higher than in Northwest China ( χ2=23.76, 11.22, P<0.01). Overall, East China showed relatively higher qualification rate in intercomparison result of both personal dose monitoring and radiation detection (including excellence), while Northwest China showed lower qualification rates (including excellence). Conclusions:Although the radiation detection capability of disease control and prevention institutions at all levels has improved in recent years, there are still insufficience of detection capabilities at some municipal- and county-level laboratories and even unbalance between different regionas. Policy support should prioritize underdeveloped areas, such as municipal- and county-level institutions and the Northwest, and enhance the technical proficiency and quality management of laboratory personnel.

Result Analysis
Print
Save
E-mail