1.Super‑resolution deep learning image reconstruction: image quality and myocardial homogeneity in coronary computed tomography angiography
Chuluunbaatar OTGONBAATAR ; Hyunjung KIM ; Pil‑Hyun JEON ; Sang‑Hyun JEON ; Sung‑Jin CHA ; Jae‑Kyun RYU ; Won Beom JUNG ; Hackjoon SHIM ; Sung Min KO
Journal of Cardiovascular Imaging 2024;32(1):30-
Background:
The recently introduced super-resolution (SR) deep learning image reconstruction (DLR) is potentially effective in reducing noise level and enhancing the spatial resolution. We aimed to investigate whether SR-DLR has advantages in the overall image quality and intensity homogeneity on coronary computed tomography (CT) angiography with four different approaches: filtered-back projection (FBP), hybrid iterative reconstruction (IR), DLR, and SR-DLR.
Methods:
Sixty-three patients (mean age, 61 ± 11 years; range, 18–81 years; 40 men) who had undergone coronary CT angiography between June and October 2022 were retrospectively included. Image noise, signal to noise ratio, and contrast to noise ratio were quantified in both proximal and distal segments of the major coronary arteries. The left ventricle myocardium contrast homogeneity was analyzed. Two independent reviewers scored overall image quality, image noise, image sharpness, and myocardial homogeneity.
Results:
Image noise in Hounsfield units (HU) was significantly lower (P < 0.001) for the SR-DLR (11.2 ± 2.0 HU) compared to those associated with other image reconstruction methods including FBP (30.5 ± 10.5 HU), hybrid IR (20.0 ± 5.4 HU), and DLR (14.2 ± 2.5 HU) in both proximal and distal segments. SR-DLR significantly improved signal to noise ratio and contrast to noise ratio in both the proximal and distal segments of the major coronary arteries.No significant difference was observed in the myocardial CT attenuation with SR-DLR among different segments of the left ventricle myocardium (P = 0.345). Conversely, FBP and hybrid IR resulted in inhomogeneous myocardial CT attenuation (P < 0.001). Two reviewers graded subjective image quality with SR-DLR higher than other image recon‑ struction techniques (P < 0.001).
Conclusions
SR-DLR improved image quality, demonstrated clearer delineation of distal segments of coronary arter‑ ies, and was seemingly accurate for quantifying CT attenuation in the myocardium.
2.Super‑resolution deep learning image reconstruction: image quality and myocardial homogeneity in coronary computed tomography angiography
Chuluunbaatar OTGONBAATAR ; Hyunjung KIM ; Pil‑Hyun JEON ; Sang‑Hyun JEON ; Sung‑Jin CHA ; Jae‑Kyun RYU ; Won Beom JUNG ; Hackjoon SHIM ; Sung Min KO
Journal of Cardiovascular Imaging 2024;32(1):30-
Background:
The recently introduced super-resolution (SR) deep learning image reconstruction (DLR) is potentially effective in reducing noise level and enhancing the spatial resolution. We aimed to investigate whether SR-DLR has advantages in the overall image quality and intensity homogeneity on coronary computed tomography (CT) angiography with four different approaches: filtered-back projection (FBP), hybrid iterative reconstruction (IR), DLR, and SR-DLR.
Methods:
Sixty-three patients (mean age, 61 ± 11 years; range, 18–81 years; 40 men) who had undergone coronary CT angiography between June and October 2022 were retrospectively included. Image noise, signal to noise ratio, and contrast to noise ratio were quantified in both proximal and distal segments of the major coronary arteries. The left ventricle myocardium contrast homogeneity was analyzed. Two independent reviewers scored overall image quality, image noise, image sharpness, and myocardial homogeneity.
Results:
Image noise in Hounsfield units (HU) was significantly lower (P < 0.001) for the SR-DLR (11.2 ± 2.0 HU) compared to those associated with other image reconstruction methods including FBP (30.5 ± 10.5 HU), hybrid IR (20.0 ± 5.4 HU), and DLR (14.2 ± 2.5 HU) in both proximal and distal segments. SR-DLR significantly improved signal to noise ratio and contrast to noise ratio in both the proximal and distal segments of the major coronary arteries.No significant difference was observed in the myocardial CT attenuation with SR-DLR among different segments of the left ventricle myocardium (P = 0.345). Conversely, FBP and hybrid IR resulted in inhomogeneous myocardial CT attenuation (P < 0.001). Two reviewers graded subjective image quality with SR-DLR higher than other image recon‑ struction techniques (P < 0.001).
Conclusions
SR-DLR improved image quality, demonstrated clearer delineation of distal segments of coronary arter‑ ies, and was seemingly accurate for quantifying CT attenuation in the myocardium.
3.Super‑resolution deep learning image reconstruction: image quality and myocardial homogeneity in coronary computed tomography angiography
Chuluunbaatar OTGONBAATAR ; Hyunjung KIM ; Pil‑Hyun JEON ; Sang‑Hyun JEON ; Sung‑Jin CHA ; Jae‑Kyun RYU ; Won Beom JUNG ; Hackjoon SHIM ; Sung Min KO
Journal of Cardiovascular Imaging 2024;32(1):30-
Background:
The recently introduced super-resolution (SR) deep learning image reconstruction (DLR) is potentially effective in reducing noise level and enhancing the spatial resolution. We aimed to investigate whether SR-DLR has advantages in the overall image quality and intensity homogeneity on coronary computed tomography (CT) angiography with four different approaches: filtered-back projection (FBP), hybrid iterative reconstruction (IR), DLR, and SR-DLR.
Methods:
Sixty-three patients (mean age, 61 ± 11 years; range, 18–81 years; 40 men) who had undergone coronary CT angiography between June and October 2022 were retrospectively included. Image noise, signal to noise ratio, and contrast to noise ratio were quantified in both proximal and distal segments of the major coronary arteries. The left ventricle myocardium contrast homogeneity was analyzed. Two independent reviewers scored overall image quality, image noise, image sharpness, and myocardial homogeneity.
Results:
Image noise in Hounsfield units (HU) was significantly lower (P < 0.001) for the SR-DLR (11.2 ± 2.0 HU) compared to those associated with other image reconstruction methods including FBP (30.5 ± 10.5 HU), hybrid IR (20.0 ± 5.4 HU), and DLR (14.2 ± 2.5 HU) in both proximal and distal segments. SR-DLR significantly improved signal to noise ratio and contrast to noise ratio in both the proximal and distal segments of the major coronary arteries.No significant difference was observed in the myocardial CT attenuation with SR-DLR among different segments of the left ventricle myocardium (P = 0.345). Conversely, FBP and hybrid IR resulted in inhomogeneous myocardial CT attenuation (P < 0.001). Two reviewers graded subjective image quality with SR-DLR higher than other image recon‑ struction techniques (P < 0.001).
Conclusions
SR-DLR improved image quality, demonstrated clearer delineation of distal segments of coronary arter‑ ies, and was seemingly accurate for quantifying CT attenuation in the myocardium.
4.The use of the bicipital groove as an intraoperative landmark for proximal humeral rotation during fracture fixation
Hyun-Joo LEE ; Sanghyun JOUNG ; Erica KHOLINNE ; Suk-Joong LEE ; Jong Pil YOON ; Jun TAN ; In-Ho JEON
The Ewha Medical Journal 2024;47(2):e25-
Objectives:
This study aimed to quantify the relationship between proximal humeral rotation and the lateral border of the bicipital groove on fluoroscopic imaging.
Methods:
A composite normal humerus with a marker placed on the lateral border of the bicipital groove was affixed to a custom rotation device at the proximal cut segment. Consecutive fluoroscopic images were captured from −60° to 60° in 5° increments and from −15° to 15° in 1° increments. The index value was calculated by taking the ratio of the distance from the medial boundary of the proximal humerus to the lateral border of the bicipital groove to the distance between the medial and lateral boundaries of the proximal humerus. The correlation between the humeral rotation and the index value was determined.
Results:
The index value showed a strong positive linear correlation position during internal rotation of the humerus across the entire range (r=0.998, P<0.001), as well as when the humerus was externally rotated, ranging from 15° of internal rotation to 15° of external rotation (r=0.991, P<0.001).
Conclusion
The lateral border of the bicipital groove may serve as a useful intraoperative landmark for assessing proximal humeral rotation. This could potentially enhance the outcomes of humeral fracture repair and upper arm arthroplasty.
5.Preventive effect of biodegradable stents on biliary stricture and fibrosis after biliary anastomosis in a porcine model
Chang-Il KWON ; Sung Hoon CHOI ; Kyu Seok KIM ; Jong Pil MOON ; Sehwan PARK ; Jinkyung JEON ; Gwangil KIM ; Jae Young JANG ; Min Je SUNG ; Kwang Hyun KO ; Jun Sik SON
Annals of Surgical Treatment and Research 2022;102(2):90-99
Purpose:
The current drain tubes for preventing surgically biliary anastomotic stricture are not naturally and easily removed. If a drain tube using biodegradable material is easily available and the degradation time of the tube is well controlled, surgical anastomotic stricture and fibrosis could be prevented. The aim of this animal study was to evaluate the preventive effect of novel biodegradable stents (BS) on biliary stricture and fibrosis after duct-to-duct (DD) biliary anastomosis.
Methods:
Ten mini-pigs were allocated to the control group (n = 5) and or the stent group (n = 5). The common bile duct was exposed through surgical laparotomy and then resected transversely. In the stent group, a 4-mm or 6-mm polydioxanone/ magnesium sheath-core BS was inserted according to the width of the bile duct, followed by DD biliary anastomosis. In the control group, DD biliary anastomosis was performed without BS insertion.
Results:
In the stent group, stents were observed without deformity for up to 4 weeks in all animals. Eight weeks later, histopathologic examination revealed that the common bile duct of the anastomosis site was relatively narrower in circumference in the control group compared to the stent group. The degree of fibrosis in the control group was more marked than in the stent group (3.84 mm vs. 0.68 mm, respectively; P < 0.05).
Conclusion
Our study showed that novel BS maintained their original shape and radial force for an adequate time and then disappeared without adverse events. The BS could prevent postoperative complications and strictures after DD biliary anastomosis.
6.Enteroscopy in Crohn’s Disease: Are There Any Changes in Role or Outcomes Over Time? A KASID Multicenter Study
Seong Ran JEON ; Jin-Oh KIM ; Jeong-Sik BYEON ; Dong-Hoon YANG ; Bong Min KO ; Hyeon Jeong GOONG ; Hyun Joo JANG ; Soo Jung PARK ; Eun Ran KIM ; Sung Noh HONG ; Jong Pil IM ; Seong-Eun KIM ; Ja Seol KOO ; Chang Soo EUN ; Dong Kyung CHANG ;
Gut and Liver 2021;15(3):375-382
Background/Aims:
Although balloon-assisted enteroscopy (BAE) enables endoscopic visualization of small bowel (SB) involvement in Crohn’s disease (CD), there is no data on the changes in outcomes over time. We therefore investigated the changes in BAE use on CD patients over different time periods in terms of its role and clinical outcomes.
Methods:
We used a multicenter enteroscopy database to identify CD patients with SB involvement who underwent BAE (131 procedures, 116 patients). We compared BAE-related factors and outcomes between the first period (70 procedures, 60 patients) and the second period (61procedures, 56 patients). The specific cutoff point for dividing the two periods was 2007, when BAE guidelines were introduced.
Results:
Initial diagnosis of SB involvement in CD was the most common indication for BAE during each period (50.0% vs 31.1%, p=0.034). The largest change was in the number of BAE uses for stricture evaluation and/or treatment, which increased significantly in the latter period (2.9% vs 21.3%, p=0.002). The diagnostic yield in patients with suspected CD was 90.7% in the first period and 95.0% in the second (p=0.695). More endoscopic interventions were performed in the second period than in the first (5.1% vs 17.6%, p=0.041). Enteroscopic success rates were high throughout (100% in the first period vs 80.0% in the second period, p>0.999). In the first and second periods, therapeutic plans were adjusted in 62.7% and 61.4% of patients, respectively.
Conclusions
The overall clinical indications, outcomes, and effectiveness of BAE were constant over time in CD patients with SB involvement, with the exception that the frequency of enteroscopic intervention increased remarkably.
7.Enteroscopy in Crohn’s Disease: Are There Any Changes in Role or Outcomes Over Time? A KASID Multicenter Study
Seong Ran JEON ; Jin-Oh KIM ; Jeong-Sik BYEON ; Dong-Hoon YANG ; Bong Min KO ; Hyeon Jeong GOONG ; Hyun Joo JANG ; Soo Jung PARK ; Eun Ran KIM ; Sung Noh HONG ; Jong Pil IM ; Seong-Eun KIM ; Ja Seol KOO ; Chang Soo EUN ; Dong Kyung CHANG ;
Gut and Liver 2021;15(3):375-382
Background/Aims:
Although balloon-assisted enteroscopy (BAE) enables endoscopic visualization of small bowel (SB) involvement in Crohn’s disease (CD), there is no data on the changes in outcomes over time. We therefore investigated the changes in BAE use on CD patients over different time periods in terms of its role and clinical outcomes.
Methods:
We used a multicenter enteroscopy database to identify CD patients with SB involvement who underwent BAE (131 procedures, 116 patients). We compared BAE-related factors and outcomes between the first period (70 procedures, 60 patients) and the second period (61procedures, 56 patients). The specific cutoff point for dividing the two periods was 2007, when BAE guidelines were introduced.
Results:
Initial diagnosis of SB involvement in CD was the most common indication for BAE during each period (50.0% vs 31.1%, p=0.034). The largest change was in the number of BAE uses for stricture evaluation and/or treatment, which increased significantly in the latter period (2.9% vs 21.3%, p=0.002). The diagnostic yield in patients with suspected CD was 90.7% in the first period and 95.0% in the second (p=0.695). More endoscopic interventions were performed in the second period than in the first (5.1% vs 17.6%, p=0.041). Enteroscopic success rates were high throughout (100% in the first period vs 80.0% in the second period, p>0.999). In the first and second periods, therapeutic plans were adjusted in 62.7% and 61.4% of patients, respectively.
Conclusions
The overall clinical indications, outcomes, and effectiveness of BAE were constant over time in CD patients with SB involvement, with the exception that the frequency of enteroscopic intervention increased remarkably.
8.Risk Factors for Postoperative Recurrence in Korean Patients with Crohn’s Disease
Sung Bae KIM ; Jae Hee CHEON ; Jae Jun PARK ; Eun Soo KIM ; Seong Woo JEON ; Sung-Ae JUNG ; Dong Il PARK ; Chang Kyun LEE ; Jong Pil IM ; You Sun KIM ; Hyun Soo KIM ; Jun LEE ; Chang Soo EUN ; Jeong Mi LEE ; Byung Ik JANG ; Geom Seog SEO
Gut and Liver 2020;14(3):331-337
Background/Aims:
A considerable number of patients with Crohn’s disease still need intestinal resection surgery. Postoperative recurrence is an important issue in Crohn’s disease management, including the selection of high-risk patients. Eastern Asian patients showed several differences from Caucasian patients. Therefore, we investigated the postoperative surgical recurrence outcome and identified risk factors in Korean patients.
Methods:
Clinical data of 372 patients with Crohn’s disease who underwent first intestinal resection between January 2004 and August 2014 at 14 hospitals in Korea were retrospectively reviewed.
Results:
Over the follow-up period, 50 patients (17.1%) showed surgical recurrence. The cumulative surgical recurrence rate was 6.5% at 1 year and 15.4% at 7 years. Age under 16 (p=0.011; hazard ratio [HR], 5.136; 95% confidence interval [CI], 1.576 to 16.731), colonic involvement (p=0.023; HR , 2.011; 95% CI, 1.102 to 3.670), and the presence of perianal disease at surgery (p=0.008; HR, 2.239; 95% CI, 1.236 to 4.059) were independent risk factors associated with surgical recurrence. Postoperative thiopurine treatment (p=0.002; HR, 0.393; 95% CI, 0.218 to 0.710) was a protective factor for surgical recurrence.
Conclusions
Among the disease characteristics at surgery, younger age, colonic location, and perianal lesions were independent risk factors for surgical recurrence. Postoperative thiopurine treatment significantly reduced the incidence of surgical recurrence.
9.Safety and Efficacy of Biodegradable Polymer-biolimus-eluting Stents (BP-BES) Compared with Durable Polymer-everolimus-eluting Stents (DP-EES) in Patients Undergoing Complex Percutaneous Coronary Intervention
Pil Sang SONG ; Kyu Tae PARK ; Min Jeong KIM ; Ki Hyun JEON ; Jin Sik PARK ; Rak Kyeong CHOI ; Young Bin SONG ; Seung Hyuk CHOI ; Jin Ho CHOI ; Sang Hoon LEE ; Hyeon Cheol GWON ; Jin Ok JEONG ; Eul Soon IM ; Sang Wook KIM ; Woo Jung CHUN ; Ju Hyeon OH ; Joo Yong HAHN
Korean Circulation Journal 2019;49(1):69-80
BACKGROUND AND OBJECTIVES: There are no data comparing clinical outcomes of complex percutaneous coronary intervention (PCI) between biodegradable polymer-biolimus-eluting stents (BP-BES) and durable polymer-everolimus-eluting stents (DP-EES). We sought to evaluate the safety and efficacy of BP-BES compared with DP-EES in patients undergoing complex PCI. METHODS: Patients enrolled in the SMART-DESK registry were stratified into 2 categories based on the complexity of PCI. Complex PCI was defined as having at least one of the following features: unprotected left main lesion, ≥2 lesions treated, total stent length >40 mm, minimal stent diameter ≤2.5 mm, or bifurcation as target lesion. The primary outcome was target lesion failure (TLF), defined as a composite of cardiac death, target vessel-related myocardial infarction (TV-MI), or target lesion revascularization (TLR) at 2 years of follow-up. RESULTS: Of 1,999 patients, 1,145 (57.3%) underwent complex PCI: 521 patients were treated with BP-BES and 624 with DP-EES. In propensity-score matching analysis (481 pairs), the risks of TLF (3.8% vs. 5.2%, adjusted hazard ratio [HR], 0.578; 95% confidence interval [CI], 0.246–1.359; p=0.209), cardiac death (2.5% vs. 2.5%, adjusted HR, 0.787; 95% CI, 0.244–2.539; p=0.689), TV-MI (0.5% vs. 0.4%, adjusted HR, 1.128; 95% CI, 0.157–8.093; p=0.905), and TLR (1.1% vs. 2.9%, adjusted HR, 0.390; 95% CI, 0.139–1.095; p=0.074) did not differ between 2 stent groups after complex PCI. CONCLUSIONS: Clinical outcomes of BP-BES were comparable to those of DP-EES at 2 years after complex PCI. Our data suggest that use of BP-BES is acceptable, even for complex PCI.
Coronary Artery Disease
;
Death
;
Drug-Eluting Stents
;
Follow-Up Studies
;
Humans
;
Myocardial Infarction
;
Percutaneous Coronary Intervention
;
Stents
10.Safety and Efficacy of Biodegradable Polymer-biolimus-eluting Stents (BP-BES) Compared with Durable Polymer-everolimus-eluting Stents (DP-EES) in Patients Undergoing Complex Percutaneous Coronary Intervention
Pil Sang SONG ; Kyu Tae PARK ; Min Jeong KIM ; Ki Hyun JEON ; Jin Sik PARK ; Rak Kyeong CHOI ; Young Bin SONG ; Seung Hyuk CHOI ; Jin Ho CHOI ; Sang Hoon LEE ; Hyeon Cheol GWON ; Jin Ok JEONG ; Eul Soon IM ; Sang Wook KIM ; Woo Jung CHUN ; Ju Hyeon OH ; Joo Yong HAHN
Korean Circulation Journal 2019;49(1):69-80
BACKGROUND AND OBJECTIVES:
There are no data comparing clinical outcomes of complex percutaneous coronary intervention (PCI) between biodegradable polymer-biolimus-eluting stents (BP-BES) and durable polymer-everolimus-eluting stents (DP-EES). We sought to evaluate the safety and efficacy of BP-BES compared with DP-EES in patients undergoing complex PCI.
METHODS:
Patients enrolled in the SMART-DESK registry were stratified into 2 categories based on the complexity of PCI. Complex PCI was defined as having at least one of the following features: unprotected left main lesion, ≥2 lesions treated, total stent length >40 mm, minimal stent diameter ≤2.5 mm, or bifurcation as target lesion. The primary outcome was target lesion failure (TLF), defined as a composite of cardiac death, target vessel-related myocardial infarction (TV-MI), or target lesion revascularization (TLR) at 2 years of follow-up.
RESULTS:
Of 1,999 patients, 1,145 (57.3%) underwent complex PCI: 521 patients were treated with BP-BES and 624 with DP-EES. In propensity-score matching analysis (481 pairs), the risks of TLF (3.8% vs. 5.2%, adjusted hazard ratio [HR], 0.578; 95% confidence interval [CI], 0.246–1.359; p=0.209), cardiac death (2.5% vs. 2.5%, adjusted HR, 0.787; 95% CI, 0.244–2.539; p=0.689), TV-MI (0.5% vs. 0.4%, adjusted HR, 1.128; 95% CI, 0.157–8.093; p=0.905), and TLR (1.1% vs. 2.9%, adjusted HR, 0.390; 95% CI, 0.139–1.095; p=0.074) did not differ between 2 stent groups after complex PCI.
CONCLUSIONS
Clinical outcomes of BP-BES were comparable to those of DP-EES at 2 years after complex PCI. Our data suggest that use of BP-BES is acceptable, even for complex PCI.

Result Analysis
Print
Save
E-mail