2.Progress in Development of Dose Verification System Software KylinRay-Dose4D.
Huaqing ZHENG ; Guangyao SUN ; Yun ZHAO ; Bo XIAO ; Jing JIA ; Tao HE ; Pengcheng LONG ; Liqin HU
Chinese Journal of Medical Instrumentation 2023;47(4):360-364
Advanced radiotherapy technology enables the dose to more accurately conform to the tumor target area of the patient, providing accurate treatment for the patient, but the gradient of the patient's radiation dose at the tumor edge is getting larger, which putting forward higher requirements for radiotherapy dose verification. The dose verification system software KylinRay-Dose4D can verify the patient's pre-treatment plan and the in vivo/on-line dose during the patient's treatment, providing important reference for the physicist to modify the radiotherapy plan and ensuring that the patient receives accurate treatment. This study introduces the overall design and key technologies of KylinRay-Dose4D, and tests the pre-treatment plan dose checking calculation and 2D/3D dose verification through clinical cases. The test results showed that the 2D/3D gamma pass rate (3 mm/3%) of KylinRay-Dose4D reconstructed dose compared with TPS plan dose and measured dose is larger than 95%, which indicating that the reconstructed dose of KylinRay-Dose4D meets the requirement of clinical application.
Humans
;
Radiotherapy Dosage
;
Radiotherapy Planning, Computer-Assisted/methods*
;
Radiotherapy, Intensity-Modulated/methods*
;
Software
;
Neoplasms
;
Phantoms, Imaging
;
Radiometry/methods*
3.Evaluation of PET Mainstream Scattering Correction Methods.
Zhipeng SUN ; Ming LI ; Jian MA ; Jinjin MA ; Guodong LIANG
Chinese Journal of Medical Instrumentation 2023;47(1):47-53
OBJECTIVE:
Current mainstream PET scattering correction methods are introduced and evaluated horizontally, and finally, the existing problems and development direction of scattering correction are discussed.
METHODS:
Based on NeuWise Pro PET/CT products of Neusoft Medical System Co. Ltd. , the simulation experiment is carried out to evaluate the influence of radionuclide distribution out of FOV (field of view) on the scattering estimation accuracy of each method.
RESULTS:
The scattering events produced by radionuclide out of FOV have an obvious impact on the spatial distribution of scattering, which should be considered in the model. The scattering estimation accuracy of Monte Carlo method is higher than single scatter simulation (SSS).
CONCLUSIONS
Clinically, if the activity of the adjacent parts out of the FOV is high, such as brain, liver, kidney and bladder, it is likely to lead to the deviation of scattering estimation. Considering the Monte Carlo scattering estimation of the distribution of radionuclide out of FOV, it's helpful to improve the accuracy of scattering distribution estimation.
Positron Emission Tomography Computed Tomography
;
Scattering, Radiation
;
Computer Simulation
;
Brain
;
Monte Carlo Method
;
Phantoms, Imaging
;
Image Processing, Computer-Assisted
4.Radiation Exposure for Patients and Staff during Different Interventional Procedures Using Anthropomorphic Phantoms: A Complete Evaluation of Different Body Regions.
Zhi Xin ZHAO ; Pei Yi QIAN ; Hai Hua WANG ; Qian QIAN ; Yong YANG ; Li Yan JING ; Lu Ting YANG ; Lei YANG ; Qiang WANG
Biomedical and Environmental Sciences 2023;36(12):1189-1193
5.Model construction and software design of computed tomography radiation system based on visualization.
Ying LIU ; Ting MENG ; Haowei ZHANG ; Heqing LU
Journal of Biomedical Engineering 2023;40(5):989-995
The Monte Carlo N-Particle (MCNP) is often used to calculate the radiation dose during computed tomography (CT) scans. However, the physical calculation process of the model is complicated, the input file structure of the program is complex, and the three-dimensional (3D) display of the geometric model is not supported, so that the researchers cannot establish an accurate CT radiation system model, which affects the accuracy of the dose calculation results. Aiming at these two problems, this study designed a software that visualized CT modeling and automatically generated input files. In terms of model calculation, the theoretical basis was based on the integration of CT modeling improvement schemes of major researchers. For 3D model visualization, LabVIEW was used as the new development platform, constructive solid geometry (CSG) was used as the algorithm principle, and the introduction of editing of MCNP input files was used to visualize CT geometry modeling. Compared with a CT model established by a recent study, the root mean square error between the results simulated by this visual CT modeling software and the actual measurement was smaller. In conclusion, the proposed CT visualization modeling software can not only help researchers to obtain an accurate CT radiation system model, but also provide a new research idea for the geometric modeling visualization method of MCNP.
Radiation Dosage
;
Software Design
;
Tomography, X-Ray Computed/methods*
;
Software
;
Algorithms
;
Phantoms, Imaging
;
Monte Carlo Method
6.A comprehensive review on photon-counting computed tomography: Principles, technical hurdles and analysis of clinical applications.
Haowei ZHANG ; Shuhan LI ; Ying LIU ; Heqing LU
Journal of Biomedical Engineering 2023;40(5):1012-1018
In recent years, photon-counting computed tomography (PCD-CT) based on photon-counting detectors (PCDs) has become increasingly utilized in clinical practice. Compared with conventional CT, PCD-CT has the potential to achieve micron-level spatial resolution, lower radiation dose, negligible electronic noise, multi-energy imaging, and material identification, etc. This advancement facilitates the promotion of ultra-low dose scans in clinical scenarios, potentially detecting minimal and hidden lesions, thus significantly improving image quality. However, the current state of the art is limited and issues such as charge sharing, pulse pileup, K-escape and count rate drift remain unresolved. These issues could lead to a decrease in image resolution and energy resolution, while an increasing in image noise and ring artifact and so on. This article systematically reviewed the physical principles of PCD-CT, and outlined the structural differences between PCDs and energy integration detectors (EIDs), and the current challenges in the development of PCD-CT. In addition, the advantages and disadvantages of three detector materials were analysed. Then, the clinical benefits of PCD-CT were presented through the clinical application of PCD-CT in the three diseases with the highest mortality rate in China (cardiovascular disease, tumour and respiratory disease). The overall aim of the article is to comprehensively assist medical professionals in understanding the technological innovations and current technical limitations of PCD-CT, while highlighting the urgent problems that PCD-CT needs to address in the coming years.
Tomography, X-Ray Computed/methods*
;
Photons
;
Noise
;
China
;
Phantoms, Imaging
7.Comprehensive evaluation method of real-time non-reference ultrasound image involving soft tissue deformation.
Yan LI ; Zeyang XIA ; Xiaojun WU ; Jing XIONG
Journal of Biomedical Engineering 2022;39(3):480-487
Ultrasound guided percutaneous interventional therapy has been widely used in clinic. Aiming at the problem of soft tissue deformation caused by probe contact force in robot-assisted ultrasound-guided therapy, a real-time non-reference ultrasound image evaluation method considering soft tissue deformation is proposed. On the basis of ultrasound image brightness and sharpness, a multi-dimensional ultrasound image evaluation index was designed, which incorporated the aggregation characteristics of the organization. In order to verify the effectiveness of the proposed method, ultrasound images of four different models were collected for experiments, including prostate phantom, phantom with cyst, pig liver tissue, and pig liver tissue with cyst. In addition, the correlation between subjective and objective evaluations was analyzed based on Spearman's rank correlation coefficient. Experimental results showed that the average evaluation time of a single image was 68.8 milliseconds. The evaluation time could satisfy real-time applications. The proposed method realizes the effective evaluation of real-time ultrasound image quality in robot-assisted therapy, and has good consistency with the evaluation of supervisors.
Animals
;
Cysts
;
Male
;
Phantoms, Imaging
;
Swine
;
Ultrasonography/methods*
8.An adaptive CT metal artifact reduction algorithm that combines projection interpolation and physical correction.
Qi Sen ZHU ; Yong Bo WANG ; Man Man ZHU ; Xi TAO ; Zhao Ying BIAN ; Jian Hua MA
Journal of Southern Medical University 2022;42(6):832-839
OBJECTIVE:
To propose an adaptive weighted CT metal artifact reduce algorithm that combines projection interpolation and physical correction.
METHODS:
A normalized metal projection interpolation algorithm was used to obtain the initial corrected projection data. A metal physical correction model was then introduced to obtain the physically corrected projection data. To verify the effectiveness of the method, we conducted experiments using simulation data and clinical data. For the simulation data, the quantitative indicators PSNR and SSIM were used for evaluation, while for the clinical data, the resultant images were evaluated by imaging experts to compare the artifact-reducing performance of different methods.
RESULTS:
For the simulation data, the proposed method improved the PSNR value by at least 0.2 dB and resulted in the highest SSIM value among the methods for comparison. The experiment with the clinical data showed that the imaging experts gave the highest scores of 3.616±0.338 (in a 5-point scale) to the images processed using the proposed method, which had significant better artifact-reducing performance than the other methods (P < 0.001).
CONCLUSION
The metal artifact reduction algorithm proposed herein can effectively reduce metal artifacts while preserving the tissue structure information and reducing the generation of new artifacts.
Algorithms
;
Artifacts
;
Image Processing, Computer-Assisted/methods*
;
Metals
;
Phantoms, Imaging
;
Tomography, X-Ray Computed/methods*
9.Sparse-view Cone-beam Breast CT Reconstruction via cGAN Constrained by Image Edges.
Yunhuan YANG ; Chengyijue FANG ; Lei ZHU
Chinese Journal of Medical Instrumentation 2022;46(2):119-125
Clinical applications of cone-beam breast CT(CBBCT) are hindered by relatively higher radiation dose and longer scan time. This study proposes sparse-view CBBCT, i.e. with a small number of projections, to overcome the above bottlenecks. A deep learning method - conditional generative adversarial network constrained by image edges (ECGAN) - is proposed to suppress artifacts on sparse-view CBBCT images reconstructed by filtered backprojection (FBP). The discriminator of the ECGAN is the combination of patchGAN and LSGAN for preserving high frequency information, with a modified U-net as the generator. To further preserve subtle structures and micro calcifications which are particularly important for breast cancer screening and diagnosis, edge images of CBBCT are added to both the generator and the discriminator to guide the learning. The proposed algorithm has been evaluated on 20 clinical raw datasets of CBBCT. ECGAN substantially improves the image qualities of sparse-view CBBCT, with a performance superior to those of total variation (TV) based iterative reconstruction and FBPConvNet based post-processing. On one CBBCT case with the projection number reduced from 300 to 100, ECGAN enhances peak-signal-to-noise ratio (PSNR) and structural similarity (SSIM) on FBP reconstruction from 24.26 and 0.812 to 37.78 and 0.963, respectively. These results indicate that ECGAN successfully reduces radiation dose and scan time of CBBCT by 1/3 with only small image degradations.
Algorithms
;
Breast
;
Cone-Beam Computed Tomography
;
Humans
;
Image Processing, Computer-Assisted
;
Phantoms, Imaging
;
Tomography, X-Ray Computed
10.An optical parameter imaging system with profile information fusion.
Tongxin LI ; Yeqing DONG ; Ming LIU ; Jing ZHAO ; Minghui LI ; Yanzhe LI
Journal of Biomedical Engineering 2022;39(2):370-379
There is a shared problem in current optical imaging technologies of how to obtain the optical parameters of biological tissues with complex profiles. In this work, an imaging system for obtaining the optical parameters of biological tissues with complex profile was presented. Firstly, Fourier transformation profilometry was used for obtaining the profile information of biological tissues, and then the difference of incident light intensity at different positions on biological tissue surface was corrected with the laws of illumination, and lastly the optical parameters of biological tissues were achieved with the spatial frequency domain imaging technique. Experimental results indicated the proposed imaging system could obtain the profile information and the optical parameters of biological tissues accurately and quickly. For the slab phantoms with height variation less than 30 mm and angle variation less than 40º, the maximum relative errors of the profile uncorrected optical parameters were 46.27% and 72.18%, while the maximum relative errors of the profile corrected optical parameters were 6.89% and 10.26%. Imaging experiments of a face-like phantom and a human's prefrontal lobe were performed respectively, which demonstrated the proposed imaging system possesses clinical application value for the achievement of the optical parameters of biological tissues with complex profiles. Besides, the proposed profile corrected method can be used to combine with the current optical imaging technologies to reduce the influence of the profile information of biological tissues on imaging quality.
Diagnostic Imaging
;
Humans
;
Light
;
Optical Imaging
;
Phantoms, Imaging

Result Analysis