1.Practice innovation in pharmaceutical management for infusion safety in hospitalized patients
Jie CHEN ; Man YOU ; Pengfei CAO ; Wenfeng TAI ; Lu MENG ; Hong ZHANG ; Guanghong HE
China Pharmacy 2025;36(10):1238-1242
OBJECTIVE To establish a pharmaceutical management model for infusion safety in hospitalized inpatients and ensure the safety of drug use. METHODS Our hospital established the standardized management process for infusion scheme, formulated rules for compatibility contraindications in drug combinations. In the form of embedded hospital official account, the infusion scheme and medication guidance WeChat developed by pharmacists are pushed to the mobile phone of inpatients, providing electronic medication guidance services for patients, and forming a pharmaceutical management model for infusion safety of inpatients. RESULTS Our hospital provided a total of 45 291 inpatients with pharmaceutical services including the formulation of individualized infusion scheme and WeChat push infusion scheme and medication guidance as of December 2023. After the implementation of the management model, the intervention rate of pharmacists on the compatibility contraindications in drug combination of long-term medical orders for inpatients increased from 18.25% before implementation to 90.58% (P<0.01), and the satisfaction rate of inpatients increased from 87.50% to 94.50% (P<0.05). CONCLUSIONS The pharmaceutical management model for infusion safety of hospitalized patients integrates pharmaceutical services throughout the entire process of intravenous medication treatment. Pharmacists can participate in the management of infusion usage while providing qualified finished infusion products, achieving closed-loop management of pharmaceutical services, improving the hospital’s pharmaceutical service capabilities and patient satisfaction, and providing guarantees for the safety and effectiveness of patient medication.
2.Etiological characteristics and molecular evolution of the first mpox case in Huai’an City of Jiangsu Province
Pengfei YANG ; Fang HE ; Qingli YAN ; Heyuan GENG ; Tong GAO ; Qiang GAO ; Chenglong XIONG ; Haiyan PENG
Chinese Journal of Schistosomiasis Control 2025;37(1):85-92
Objective To analyze the virus subtypes, molecular evolutional and molecular transmission network features of the first confirmed mpox case in Huai’an City, Jiangsu Province, so as to provide insights into understanding of the transmission and evolution dynamics of mpox virus and formulation of the mpox control strategy in the city. Methods Genomic DNA was extracted from swabs of the first confirmed mpox case’s skin lesions in Huai’an City, and the amplicon sequencing library was constructed using the hypersensitive mpox virus whole-genome capture kit. High-throughput sequencing was performed using the GridION X5 nanopore sequencer on the Nanopore sequencing platform, and single nucleotide polymorphism (SNP) analysis of mpox virus genome sequences was performed following sequence assembly. In addition, phylogenetic analysis, genetic genealogy and molecular traceability analysis were performed. Results The virus whole genome sequence of the first confirmed mpox case was successfully obtained by high-throughput sequencing, with a full length of 197 182 bp, and was named hMpxV/China/JS-HA01/2023, which belonged to the clade IIb (West African clade) lineage B.1.3. Compared with the mpox virus reference sequence MPXV-M5312_HM12_Rivers-001 (GenBank accession number: NC_063383), the genome sequence of the Huai’an virus isolate carried 86 SNPs, including 40 SNPs in the coding region as non-synonymous mutations and 73 SNPs as nucleotide mutations caused by APOBEC3 (APOBEC3). Of the 97 mpox virus gene sequences, 79 sequences were included in the molecular network (81.44%), and the threshold of the genetic distance accessed to the network was 0.35/105. There were two large molecular transmission clusters and one scattered cluster in the molecular transmission network of the mpox virus, andthehMpxV/China/JS-HA01/2023 sequence was located in the large cluster. The 97 gene sequences formed 92 haplotypes, including three shared haplotypes Hap_4, Hap_6 and Hap_38, and an exclusive haplotype Hap_1 of hMpxV/China/JS-HA01/2023 generated from mutation of the exclusive haplotype Hap_43, while the exclusive haplotype Hap_43 was generated from mutation of the shared haplotype Hap_38. Conclusions The whole genome sequence of the mpox virus isolated from the first confirmed mpox case in Huai’an City has been successfully obtained, and the molecular evolutionary and molecular transmission network characteristics of the virus have been preliminarily understood.
3.Advances in diffuse optical technology lenses for myopia control
Kun HE ; Bingxin PAN ; Suyun YANG ; Zhiyang HE ; Mengting ZHENG ; Meiling SHU ; Pengfei JIANG ; Shan XU ; Pengfei TIAN
International Eye Science 2025;25(9):1476-1483
Recent years have witnessed significant advancements in myopia control research through the application of diffuse optical technology(DOT)spectacle lenses. Myopia has emerged as a global public health challenge, affecting nearly half of the world's population, with childhood and adolescent myopia rates continuing to rise. DOT lenses represent an innovative myopia control intervention based on retinal contrast signal theory. These lenses incorporate micro-light scattering dots distributed across the lens surface to reduce retinal imaging contrast and modulate the influence of visual input on axial elongation, thereby slowing myopia progression. The core mechanism operates through refractive index differences between the lens substrate(1.53)and scattering dots(1.50), which generate optical scattering effects. This design maintains clear vision through a central 5 mm optical zone while effectively reducing contrast signal intensity in the peripheral retina. Large-scale randomized controlled trials, including the CYPRESS study, have demonstrated significant myopia control efficacy in children aged 6-10 years: 12-month follow-up data revealed a 74% reduction in myopia progression and a 50% reduction in axial elongation, with sustained safety and visual quality maintained over 4-year long-term follow-up. However, several aspects of DOT technology remain contentious and require further clinical validation, including its applicability across different age groups, optimal scattering dot density configurations, combined application effects with other myopia control methods, and long-term visual adaptation during extended use. This review systematically examines the theoretical foundations, design characteristics, clinical application progress, and future development directions of DOT technology, providing scientific evidence for clinical myopia prevention and control strategy formulation.
4.An economical and flexible chip using surface-enhanced infrared absorption spectroscopy for pharmaceutical detection: Combining qualitative analysis and quantitative detection.
Jikai WANG ; Pengfei ZENG ; Haitao XIE ; Suisui HE ; Xilin XIAO ; Cuiyun YU
Journal of Pharmaceutical Analysis 2025;15(2):101076-101076
Image 1.
5.Neuromechanical compensation mechanisms for plantar pressure imbalance in unilateral and bilateral pes cavus:a stability early warning model based on center of pressure trajectory classification
Zhiguo HE ; Liansheng SHAO ; Pengfei SUN ; Hongyi LI ; Guangming BIAN ; Wen MIN
Journal of Clinical Medicine in Practice 2025;29(19):73-78
Objective To investigate the biomechanical differences in plantar pressure,postural stability,and plantar Visual Analogue Scale(VAS)scores between normal feet and unilateral/bilat-eral pes cavus,reveal their unique neuromechanical compensation mechanisms,and construct a sta-bility early warning model based on the minimum center of pressure(COP)trajectory classification.Methods A total of 70 patients with pes cavus from December 2023 to October 2024 were selected as study subjects,including 33 patients in the unilateral pes cavus group and 37 patients in the bilat-eral pes cavus group.During the same period,32 normal feet were included as normal foot group.A flat-panel plantar pressure testing system was used to collect dynamic plantar pressure data and COP trajectories from three groups at a self-selected walking speed.There were no statistically significant differences in baseline data such as age,gender,and body mass index among the three groups(P>0.05).One-way analysis of variance and the Wilcoxon rank-sum test were used to compare the differences in maximum pressure,contact area,VAS scores,and the 95%confidence ellipse area of the COP among the three groups in 10 plantar regions.Results Patients with pes cavus exhibited lower peak pressure in the MF region compared to normal feet,while higher peak pressure in the M2,M3,and MH regions.Patients with bilateral pes cavus showed lower peak pressure in the T1 region compared to normal feet,and patients with unilateral pes cavus had lower peak pressure in the LH region compared to the normal group(P<0.05).The plantar contact area in patients with pes cavus was reduced in the T1,M2,M3,M4,MF,and MH regions compared to normal feet(P<0.05).The 95%confidence ellipse area of the COP was larger in both the bilateral and uni-lateral pes cavus groups compared to the normal foot group(P<0.001).Unilateral pes cavus pres-ented a specific lateral COP drift(amplitude of 3 to 4 cm),which is a biomechanical manifestation of compensatory eversion of the unaffected foot.Patients with bilateral pes cavus exhibited a"bimod-al oscillation"trajectory(amplitude of 6 to 8 cm),suggesting possible vestibular-spinal regulatory dysfunction and the poorest postural stability.In the pes cavus group,there was a significant in-crease in pressure in the M2,M3,and MH regions,with peak pressures exceeding 190 kPa in pa-tients with bilateral pes cavus,which was highly correlated with plantar pain and could serve as a pain early warning threshold.Conclusion Unilateral and bilateral pes cavus exhibit significantly different neuromechanical compensation patterns.The classification based on the"lateral drift"and"bimodal oscillation"characteristics of the COP trajectory can serve as a stability early warning indi-cator for assessing fall risk.Decompression interventions targeting the key pressure regions of M2,M3,and MH(such as customized orthotic insoles)are the core strategies for alleviating pain and optimizing dynamic gait stability.
6.Updates and amendments of standards for Chinese medicinal materials and decoction pieces characteristics in the Chinese Pharmacopoeia
LI Zhengguo ; ZHANG Hongwei ; WANG Haibo ; HE Yi ; TU Pengfei
Drug Standards of China 2024;25(1):041-047
According to the relevant requirements of the Chinese Pharmacopoeia and relevant reports, this article briefly introduces the basic principles, research ideas, and precautions for the revision of the “characteristics” standards of Chinese medicinal materials and decoction pieces. In recent years, enterprises and social media reported that the characteristics of Chinese medicinal materials in the market did not fully comply with the characteristics specified in the Chinese Pharmacopoeia. Therefore, this article explored the variation in the characteristics of Chinese medicinal materials and decoction pieces and its main reasons, scientific and reasonable revision of the “characteristics” of Chinese medicinal materials and decoction pieces, the new methods for identifying properties, as well as the issues that need to be noted in revising the characteristics of Chinese medicinal materials and decoction pieces, which provided reference for the revision of the “characteristics” standards of Chinese medicinal materials and decoction pieces.
7.Research advance of clinical application of X-ray Flash-RT equipment
Ruo TANG ; Xiaozhong HE ; Pengfei ZHU ; Zhuo ZHANG ; Ziping HUANG ; Shuqing LIAO ; Tao WEI ; Liu YANG ; Jinshui SHI
China Medical Equipment 2024;21(1):24-28
The protection effect of flash-radiotherapy(Flash-RT)with super-high dose on normal tissue has obtained wide attention in therapeutic radiology since it was found in 2014 year.The increasing research demand of Flash-RT with super-high dose-rate proposed new challenge for the existing radiotherapy equipment.Based on the demands of FLASH-RT research and clinical application,this review analyzed the proposed new requirement of Flash-RT for equipment,and introduce current scientific facilities with the experimental ability of X-ray FLASH-RT,as well as the situation of the specialized FLASH-RT equipment which were developing.The research of Flash-RT mechanism need the existing equipment with high-energy X-ray source develop toward high power,while the clinical application of Flash-RT demand these transient high-power devices should possess a series of radiotherapy techniques such as multi angle irradiation,conformal radiotherapy and others.Currently,China's X-ray FLASH-RT research is at the forefront of the world,which is expected to achieve the first breakthrough of high-end medical equipment in the X-ray Flash RT field.
8.Study of synovial mesenchymal stem cells combined with PRP in cartilage repair
Xunan XU ; Tongguang XU ; Pengfei CAO ; Yongfeng HUANG ; Qiang WANG ; Yi HE ; Yong LIU
China Medical Equipment 2024;21(3):148-153,158
Objective:To compare the repair effects of three kinds of treatment methods included synovial mesenchymal stem cells(SMSCs),platelet rich plasma(PRP)and the combination of them with knee joint cavity injection on cartilage injury of rabbit.Methods:A total of 24 New Zealand rabbits were selected to establish a cartilage injury model of knee joint by using surgery in knee joint of them.The rabbits with cartilage injury model were divided into four groups using a random number table method,which included blank group,single SMSCs with joint cavity injection group(SMSCs group),PRP with joint cavity injection group(PRP group)and the combination of SMSCs and PRP with joint cavity injection group(SMSCs+PRP group),with 6 rabbits in each group.The synovium of four groups of rabbits were scraped off their joints to conduct in vitro culture of SMSCs,as well as the morphological observation and identification of SMSCs.The venous bloods of rabbits were extracted to prepare PRP by centrifugation.The contents of PRP,platelet and growth factor in blood were compared.The SMSCs and PRP were injected into the knee joint cavity of three groups of rabbits with model.After 2,4 and 6 weeks of injection treatment,the repair statuses of cartilages at defection area of different groups were evaluated according to cartilage repair scoring table of International Association for Cartilage Repair(ICRS).Results:The primary synovial cells of rabbit knee joint synovium were initially round in shape after isolation,but almost all of them were spindle shaped after passage.The positive detection rates of SMSCs surface antigen CD73,CD90 and CD105 of 4 group were respectively 100%,99.22%and 99.99%.The CD45 detection was 0.5%,which indicated that they possessed the property of stem cell.The platelet count of 4 groups showed that the platelet concentration in PRP was approximate 6 times of that in whole blood.The concentrations of platelet derived growth factor(PDGF),transforming growth factor-β(TGF-β)and vascular endothelial growth factor(VEGF)were respectively(569.15±57.48)ng/mL,(633.56±63.90)ng/mL and(1 243.55±106.04)ng/mL in PRP,which were approximately 5 times,6 times and 7 times of that in whole blood,respectively.After 2 weeks of injection treatment for joint cavity,there was no significant statistical difference in the scores of cartilage repair among 4 groups(P>0.05).At 4 and 6 weeks of injection treatment,the morphological and histological score of cartilage repair of the SMSCs+PRP group were significantly higher than those of the blank group,and the differences were significant(t4 week=6.35,9.15,t6 week=8.16,8.60,P<0.05),respectively.Conclusion:The repair effect of SMSCs combined with PRP on cartilage injury of rabbit is significantly better than that of single PRP and single SMSCs,respectively,and all of them are better than those without treatment.SMSCs combined with PRP can significantly improve the effect of self-repair of cartilage injury.
9.Early outcomes of anterior segment parameters in patients with high myopia after implantable collamer lens V4c implantation
Bingxin PAN ; Jie WU ; Pengfei JIANG ; Shan XU ; Kun HE
International Eye Science 2024;24(3):491-494
AIM: To study the early outcomes of anterior segment parameters after implantation of an implantable collamer lens with a central hole(ICL V4c)in patients with high myopia.METHODS:A total of 82 cases(160 eyes)with high myopia, including 42 males(82 eyes)and 40 females(78 eyes), aged 26.0±4.6(21 to 37)years, who underwent ICL V4c implantation at our institution from February 2019 to September 2022 and were followed up for 1 a, were included. The general characteristics of the anterior segment of the eye were measured preoperatively: spherical equivalent, mean horizontal corneal curvature, white-to-white(WTW), and axial length(AL); intraocular pressure(IOP), endothelial cell density(ECD), central anterior chamber depth(CACD), anterior chamber volume(ACV)and anterior chamber angle(ACA)were measured preoperatively and at 1 d, 1 wk, 1, 3 and 6 mo postoperatively. Furthermore, the distance from the centre of the posterior surface of the ICL V4c optical zone to the anterior surface of the lens(vault)was measured at 1 d, 1 wk, 1, 6 mo, and 1 a after surgery.RESULTS: The mean preoperative spherical equivalent of the patients was -7.56±2.55 D, mean horizontal corneal curvature was 42.89±1.47 D, WTW was 11.64±0.37 mm, and AL was 26.64±0.93 mm. The baseline IOP was 15.97±2.13 mmHg, and the differences in IOP at each time point after ICL V4c implantation compared to preoperative were not statistically significant(F=0.875, P=0.504); ECD was 2 989.30±140.78 cells/mm2 at baseline, and ECD at 6 mo after ICL V4c implantation was not statistically significant compared with preoperative ECD(t=1.475, P=0.142); CACD was 3.19±0.21 mm at baseline, and ACV was 210.30±27.7 mm3, and CACD and ACV were significantly lower than preoperative at all postoperative time points(F=111.10, 288.38, all P<0.001). The baseline ACA was 35.44°±11.27°, and the ACA at each time point after ICL V4c implantation was significantly lower than preoperatively(F=21.23, P<0.001). The vault was 665.32±184.03 μm at 1 d postoperatively, and continued to be significantly reduced at 1 wk, 1, 6 mo, and 1 a postoperatively compared with 1 d(F=52.10, P<0.001). However, it remained stable at 6 mo and 1 a postoperatively, and the difference was not statistically significant compared with vault at 1 mo postoperatively(P>0.05).CONCLUSION: ICL V4c has certain safety and efficiency in 1 a postoperative follow-up, and the parameters of the anterior segment of the eye stabilized in the early period.
10.Penile protection with a self-developed flexible sleeve penile protection device after circumcision: a prospective randomized controlled trial
Pengfei TUO ; Kewei CHEN ; Xinchen LIU ; Guodong ZHU ; Huixing HE ; Tao CAI ; Yuxuan LI ; Xun ZHAO ; Liyuan GE ; Shudong ZHANG ; Lulin MA ; Wei GUO ; Zhuo LIU
Journal of Modern Urology 2024;29(4):363-367
【Objective】 To investigate the protective effects of aflexible sleeve penile protection device on reducing postoperative pain and wound edema in patients after circumcision. 【Methods】 A total of 54 patients who underwent circumcision at Yan’an Branch of Peking University Third Hospital during Feb.1 and May 31, 2023 were enrolled.The patients were randomly divided into the experimental group and control group, with 27 patients in either groups.Patients in the experimental group were treated with a flexible sleeve penis protection device after surgery, and patients in the control group were treated with traditional gauze bandage after surgery.Postoperative pain, wound edema and complications were compared between the two groups. 【Results】 In terms of pain, the visual analogue scale of the experimental group was significantly lower at 6 hours [(1.7±0.9) vs.(3.3±1.9), P<0.001] and 2 days [(2.0±1.3) vs.(3.3±1.3), P<0.001] after surgery than that of the control group, but there were no statistically significant differences between the two groups on the 4th and 7th postoperative days (P>0.05).In terms of edema, the edema score of the experimental group was significantly lower than that of the control group on the 2nd postoperative day [(2.0±1.0) vs.(4.0±0.8), P<0.001] , the 4th postoperative day [(1.5±1.2) vs.(2.6±0.9), P<0.001] , and the 7th postoperative day [(0.9±1.3) vs.(2.3±1.5), P<0.001] .There was no statistically significant difference in the incidence of complications between the two groups (P>0.05). 【Conclusion】 The flexible sleeve penile protection device has significant effects of reducing early postoperative pain and reducing edema in patients undergoing circumcision.

Result Analysis
Print
Save
E-mail