1.Deploying artificial intelligence in the detection of adult appendicular and pelvic fractures in the Singapore emergency department after hours: efficacy, cost savings and non-monetary benefits.
John Jian Xian QUEK ; Oliver James NICKALLS ; Bak Siew Steven WONG ; Min On TAN
Singapore medical journal 2025;66(4):202-207
INTRODUCTION:
Radiology plays an integral role in fracture detection in the emergency department (ED). After hours, when there are fewer reporting radiologists, most radiographs are interpreted by ED physicians. A minority of these interpretations may miss diagnoses, which later require the callback of patients for further management. Artificial intelligence (AI) has been viewed as a potential solution to augment the shortage of radiologists after hours. We explored the efficacy of an AI solution in the detection of appendicular and pelvic fractures for adult radiographs performed after hours at a general hospital ED in Singapore, and estimated the potential monetary and non-monetary benefits.
METHODS:
One hundred and fifty anonymised abnormal radiographs were retrospectively collected and fed through an AI fracture detection solution. The radiographs were re-read by two radiologist reviewers and their consensus was established as the reference standard. Cases were stratified based on the concordance between the AI solution and the reviewers' findings. Discordant cases were further analysed based on the nature of the discrepancy into overcall and undercall subgroups. Statistical analysis was performed to evaluate the accuracy, sensitivity and inter-rater reliability of the AI solution.
RESULTS:
Ninety-two examinations were included in the final study radiograph set. The AI solution had a sensitivity of 98.9%, an accuracy of 85.9% and an almost perfect agreement with the reference standard.
CONCLUSION
An AI fracture detection solution has similar sensitivity to human radiologists in the detection of fractures on ED appendicular and pelvic radiographs. Its implementation offers significant potential measurable cost, manpower and time savings.
Humans
;
Singapore
;
Emergency Service, Hospital
;
Fractures, Bone/diagnostic imaging*
;
Artificial Intelligence
;
Retrospective Studies
;
Adult
;
Male
;
Female
;
Cost Savings
;
Middle Aged
;
Pelvic Bones/diagnostic imaging*
;
Reproducibility of Results
;
Aged
;
Sensitivity and Specificity
;
Radiography
2.Biomechanical study on wing shaped titanium plate fixation of acetabular anterior column and posterior hemi-transverse fracture under multiple working conditions.
Jianwu ZHANG ; WURIKAIXI AIYITI ; Gang LYU ; MAIMAIAILI YUSHAN ; Zhiqiang MA ; Chao MA
Journal of Biomedical Engineering 2025;42(2):351-358
This article aims to compare and analyze the biomechanical differences between wing-shaped titanium plates and traditional titanium plates in fixing acetabular anterior column and posterior hemi-transverse (ACPHT) fracture under multiple working conditions using the finite element method. Firstly, four sets of internal fixation models for acetabular ACPHT fractures were established, and the hip joint stress under standing, sitting, forward extension, and abduction conditions was calculated through analysis software. Then, the stress of screws and titanium plates, as well as the stress and displacement of the fracture end face, were analyzed. Research has found that when using wing-shaped titanium plates to fix acetabular ACPHT fractures, the peak stress of screws decreases under all working conditions, while the peak stress of wing-shaped titanium plates decreases under standing and sitting conditions and increases under forward and outward extension conditions. The relative displacement and mean stress of the fracture end face decrease under all working conditions, but the values are higher under forward and outward extension conditions. Wing-shaped titanium plates can reduce the probability of screw fatigue failure when fixing acetabular ACPHT fractures and can bear greater loads under forward and outward extension conditions, improving the mechanical stability of the pelvis. Moreover, the stress on the fracture end surface is more conducive to stimulating fracture healing and promoting bone tissue growth. However, premature forward and outward extension rehabilitation exercises should not be performed.
Titanium
;
Bone Plates
;
Humans
;
Acetabulum/surgery*
;
Fracture Fixation, Internal/methods*
;
Biomechanical Phenomena
;
Finite Element Analysis
;
Bone Screws
;
Fractures, Bone/surgery*
;
Stress, Mechanical
;
Working Conditions
3.Automatic measurement of acetabular cup anteversion angle using an accurate recognition technology based on improved Otsu algorithm and feature point.
Qian LIU ; Yunqing MA ; Bo WU ; Yao ZHANG ; Jingwen QI ; Yuqian MEI
Journal of Biomedical Engineering 2025;42(3):592-600
The orientation of the acetabular cup in hip joint anteroposterior radiograph is a key factor in evaluating the postoperative outcomes of total hip arthroplasty (THA). Currently, measurement of the acetabular cup anteversion angle primarily relies on manual drawing of auxiliary lines by orthopedic surgeons and calculations using scientific calculators. This study proposes an automated computer-aided measurement method for the acetabular cup anteversion angle based on hip joint anteroposterior radiograph. The proposed method segments hip prosthesis images using an improved Otsu algorithm, identifies feature points at the acetabular cup opening by combining circle-fitting theory and the cup's geometric characteristics, and fits an ellipse to the cup opening to calculate the anteversion angle. A total of 104 hip joint anteroposterior radiographs, including 71 right-sided and 81 left-sided prostheses, were analyzed. Two orthopedic surgeons independently measured the postoperative anteversion angles, and the results were compared with computer-generated measurements for correlation analysis. Spearman and Pearson correlation analyses demonstrated significant correlations between the proposed method and manual measurements for both the right group ( r = 0.795, P < 0.01) and the left group ( r = 0.859, P < 0.01). This method provides a reliable reference for orthopedic surgeons to assess postoperative prognosis.
Humans
;
Acetabulum/anatomy & histology*
;
Arthroplasty, Replacement, Hip/methods*
;
Algorithms
;
Hip Prosthesis
;
Hip Joint/diagnostic imaging*
;
Radiography
;
Image Processing, Computer-Assisted/methods*
4.Application of personalized three-dimensional printed customized prostheses in severe Paprosky type Ⅲ acetabular bone defects.
Shuailei LI ; Hao CHAI ; Yongqiang SUN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):13-19
OBJECTIVE:
To analyze the short-term effectiveness and safety of personalized three-dimensional (3D) printed customized prostheses in severe Paprosky type Ⅲ acetabular bone defects.
METHODS:
A retrospective analysis was conducted on 8 patients with severe Paprosky type Ⅲ acetabular bone defects and met the selection criteria between January 2023 and June 2024. There were 3 males and 5 females, with an average age of 64.6 years ranged from 56 to 73 years. All primary replacement prostheses were non-cemented, including 1 ceramic-ceramic interface, 1 ceramic-polyethylene interface, and 6 metal-polyethylene interfaces. The time from the primary replacement to the revision was 4 days to 18 years. The reasons for revision were aseptic loosening in 5 cases, revision after exclusion in 2 cases, and repeated dislocation in 1 case. The preoperative Harris score was 39.5±3.7 and the visual analogue scale (VAS) score was 7.1±0.8. The operation time, intraoperative blood loss, hospital stay, and complications were recorded. The hip function was evaluated by Harris score, and the degree of pain was evaluated by VAS score. The acetabular cup abduction angle, anteversion angle, rotational center height, greater trochanter height, and femoral offset were measured on X-ray film.
RESULTS:
The operation time was 95-223 minutes, with an average of 151.13 minutes. The intraoperative blood loss was 600-3 500 mL, with an average of 1 250.00 mL. The hospital stay was 13-20 days, with an average of 16.88 days. All 8 patients were followed up 2-12 months, with an average of 6.4 months. One patient had poor wound healing after operation, which healed well after active symptomatic treatment. One patient had lower limb intermuscular vein thrombosis, but no thrombosis was found at last follow-up. No serious complications such as aseptic loosening, infection, dislocation, and periprosthetic fracture occurred during the follow-up. At last follow-up, the Harris score was 72.0±6.2 and the VAS score was 1.8±0.7, which were significantly different from those before operation ( t=-12.011, P<0.001; t=16.595, P<0.001). On the second day after operation, the acetabular cup abduction angle ranged from 40° to 49°, with an average of 44.18°, and the acetabular cup anteversion angle ranged from 19° to 26°, with an average of 21.36°, which were within the "Lewinneck safety zone". There was no significant difference in the rotational center height, greater trochanter height, and femoral offset between the healthy side and the affected side ( P>0.05).
CONCLUSION
The use of personalized 3D printed customized prostheses for the reconstruction of severe Paprosky type Ⅲ acetabular bone defects can alleviate pain and enhances hip joint function, and have good postoperative prosthesis position, without serious complications and have good safety.
Humans
;
Printing, Three-Dimensional
;
Male
;
Female
;
Middle Aged
;
Acetabulum/surgery*
;
Aged
;
Retrospective Studies
;
Hip Prosthesis
;
Prosthesis Design
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Reoperation
;
Treatment Outcome
5.Posterior minimally invasive approach for treatment of posterior wall acetabular fractures.
Wenbo LI ; Lihong LIU ; Peisheng SHI ; Yun XUE ; Wei WANG ; Jie SHI ; Chuangbing LI ; Xianqing SHI ; Xiaowen DENG ; Qiuming GAO
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):134-139
OBJECTIVE:
To investigate the effectiveness of posterior minimally invasive approach in the treatment of posterior wall acetabular fractures.
METHODS:
The clinical data of 17 patients with posterior wall acetabular fractures treated with posterior minimally invasive approach between March 2019 and June 2023 were retrospectively analyzed. There were 14 males and 3 females with an average age of 41 years ranging from 28 to 57 years. The causes of injury were traffic accident in 12 cases and falling from height in 5 cases. There were 3 cases complicated with posterior hip dislocation and 2 cases complicated with sciatic nerve injury. According to AO/Orthopaedic Trauma Association (AO/OTA) classification, there were 11 cases of type A1.1 and 6 cases of type A1.2. The time from injury to operation was 5-8 days, with an average of 6.2 days. The incision length, intraoperative blood loss, and operation time were recorded. The quality of posterior wall fracture reduction were evaluated by Matta criteria, and hip function were evaluated by modified Merle d'Aubign-Postel score criteria at 6 months after operation and last follow-up.
RESULTS:
The operation was successfully completed in 17 cases. The length of incision ranged from 7 to 9 cm, with an average of 8.3 cm, and all incisions healed by first intention. The intraoperative blood loss ranged from 200 to 350 mL, with an average of 281 mL. The operation time ranged from 45 to 70 minutes, with an average of 57 minutes. Two patients had sciatic nerve injury before operation, and the sciatic nerve function recovered completely at 3 months after operation; the other 15 patients had no symptoms of sciatic nerve injury after operation. All the 17 patients were followed up 14-27 months, with an average of 19.5 months. At 1 week after operation, according to the Matta criteria, anatomical reduction was achieved in 12 cases and satisfactory reduction in 5 cases, with a satisfaction rate of 100%. According to the modified Merle d'Aubign-Postel scoring system, the hip function score was 13-18 (mean, 16.1) at 6 months after operation. Among them, 5 cases were excellent, 9 were good, and 3 were fair, with an excellent and good rate of 82.4%. At last follow-up, the hip function score was 7-18 (mean, 13.7), of which 3 cases were excellent, 9 were good, 3 were fair, and 2 were poor, with an excellent and good rate of 70.6%. During the follow-up, there was no infection, failure of internal fixation, and femoral head necrosis, and heterotopic ossification occurred in 2 cases.
CONCLUSION
The posterior minimally invasive approach has the advantages of less trauma, shorter operation time, less blood loss, without cutting off the external rotator muscle. Exposure through the gluteus medius-piriformis space and piriformis-supercilium space can provide sufficient safe exposure for the posterior wall acetabulum fracture, which is a reliable alternative approach for the posterior acetabular fracture.
Humans
;
Acetabulum/surgery*
;
Male
;
Female
;
Adult
;
Middle Aged
;
Minimally Invasive Surgical Procedures/methods*
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Fractures, Bone/diagnostic imaging*
;
Treatment Outcome
;
Operative Time
6.Study on assessment methods for acetabular cup size in total hip arthroplasty.
Jinzi WANG ; Wenju CHANG ; Pei ZHANG ; Xiang LI ; Yong ZHANG ; Shuoshuo ZHANG ; Hai DING
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):163-167
OBJECTIVE:
To evaluate precise assessment methods for predicting the optimal acetabular cup size in total hip arthroplasty (THA).
METHODS:
A clinical data of 73 patients (80 hips) who underwent primary THA between December 2022 and July 2024 and met the inclusion criteria was analyzed. There were 39 males and 34 females with an average age of 66.3 years (range, 56-78 years). Among them, 66 cases were unilateral THA and 7 were bilateral THAs. There were 29 patients (34 hips) of osteoarthritis, 35 patients (35 hips) of femoral neck fractures, and 9 patients (11 hips) of osteonecrosis of the femoral head. Based on anteroposterior pelvic X-ray films, three methods were employed to predict acetabular cup size, including preoperative template planning, radiographic femoral head diameter (FHD) measurement, and intraoperative FHD measurement. The predicted acetabular cup sizes from these methods were compared with the actual implanted sizes.
RESULTS:
The predicted acetabular cup sizes using the preoperative template planning, radiographic FHD measurement, and intraoperative FHD measurement were (51.25±2.81), (49.72±3.11), and (49.90±2.74) mm, respectively, compared to the actual implanted cup size of (50.57±2.74) mm, with no significant difference ( P>0.05). Regarding agreement with the actual implanted cup size, the preoperative template planning achieved exact matches in 35 hips (43.75%), one-size deviation in 41 hips (51.25%), and two-size deviations in 4 hips (5%); the radiographic FHD measurement achieved exact matches in 12 hips (15%), one-size deviation in 57 hips (71.25%), and two-size deviations in 11 hips (13.75%); and the intraoperative FHD measurement achieved exact matches in 26 hips (32.5%), one-size deviation in 52 hips (65%), and two-size deviations in 2 hips (2.5%). There were significant differences in agreement distributions between the three methods and the actual implanted cup sizes ( H=18.579, P<0.001).
CONCLUSION
The intraoperative FHD measurement, as a simple, cost-effective, and accurate method, effectively guides acetabular cup selection, reduces the risk of prosthesis wear, enhances postoperative joint stability.
Humans
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Male
;
Female
;
Middle Aged
;
Acetabulum/diagnostic imaging*
;
Aged
;
Hip Prosthesis
;
Prosthesis Design
;
Femur Head/surgery*
;
Osteoarthritis, Hip/surgery*
;
Radiography
;
Femoral Neck Fractures/surgery*
;
Femur Head Necrosis/surgery*
7.Short-term effectiveness of anterior and middle columns repair and reconstruction with whole autogenous spinous process-laminar bone through posterior approach in thoracolumbar tuberculosis.
Hongwei CHEN ; Tao LI ; Hua CHEN ; Peng XIU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):201-208
OBJECTIVE:
To investigate the short-term effectiveness of the anterior and middle columns in thoracolumbar tuberculosis reconstructed with whole autogenous spinous process-laminar bone through posterior approach.
METHODS:
The retrospective study included 78 patients with thoracolumbar tuberculosis who underwent posterior approach surgery and anterior and middle column bone graft reconstruction between January 2012 and May 2023. Based on the type of autogenous bone graft used, patients were divided into group A (whole autogenous spinous process-laminar bone graft, 38 cases) and group B (autogenous structural iliac bone graft, 40 cases). There was no significant difference of baseline data, such as age, gender, disease duration, involved segment of spinal tuberculosis, and preoperative erythrocyte sedimentation rate (ESR), C reactive protein (CRP), Oswestry disability index (ODI), visual analogue scale (VAS) score, the American Spinal Injury Association (ASIA) grade, segmental kyphotic angle, and intervertebral height between the two groups ( P>0.05). The operation time, intraoperative blood loss, postoperative drainage, hospital stays, ESR, CRP, VAS score, ODI, bone fusion time, ASIA grade for neurological status valuation, postoperative complications, change of segmental kyphotic angle, change of intervertebral height were recorded and compared between the two groups.
RESULTS:
The operation time in group A was significantly shorter than that in group B ( P<0.05); there was no significant difference in intraoperative blood loss, postoperative drainage, and hospital stays between the two groups ( P>0.05). All patients in the two groups were followed up 14-110 months (mean, 64.1 months); there was no significant difference in the follow-up time between the two groups ( P>0.05). The ESR, CRP, ODI, and VAS score at each time point after operation in both groups significantly improved when compared with those before operation, and further improved with the extension of time, the differences were significant ( P<0.05). There was no significant difference between the two groups ( P>0.05) except that the VAS score of group A was significantly better than that of group B at 3 days after operation ( P<0.05). There was no significant difference in fusion time between the two groups ( P>0.05). The neurological function of most patients improved after operation, and there was no significant difference in ASIA grade between the two groups at last follow-up ( P>0.05). There was no significant difference in segmental kyphosis angle and intervertebral height between the two groups at each time point ( P>0.05), and no significant difference in segmental kyphosis angle, intervertebral height correction and loss were found between the two groups ( P>0.05). In group A, there was 1 case of incision fat liquefaction and 1 case of incision infection; in group B, there was 1 case of deep venous thrombosis, 2 cases of pleural effusion, and 10 cases of pain in bone harvesting area; in both groups, there were 2 cases of gout caused by hyperuricemia. There was a significant difference in the incidence of pain in bone harvesting area between the two groups ( P<0.05), and there was no significant difference in the incidence of other complications between the two groups ( P>0.05).
CONCLUSION
Whole autogenous spinous process-laminar bone grafting is equivalent to structural iliac bone graft in reconstruction of the anterior and middle columns in thoracolumbar tuberculosis through posterior approach, effectively supporting the stability of the anterior and middle columns of the spine, while resulting in shorter operation time and less postoperative pain in bone harvesting area.
Humans
;
Tuberculosis, Spinal/surgery*
;
Thoracic Vertebrae/surgery*
;
Lumbar Vertebrae/surgery*
;
Bone Transplantation/methods*
;
Retrospective Studies
;
Male
;
Female
;
Treatment Outcome
;
Plastic Surgery Procedures/methods*
;
Adult
;
Middle Aged
;
Transplantation, Autologous
;
Operative Time
;
Ilium/transplantation*
8.Effectiveness analysis of 5G remote robotic surgery in pelvic fracture treatment.
Yonghong DAI ; Kuangyang YANG ; Yanhui ZENG ; Wei HAN ; Junqiang WANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):391-398
OBJECTIVE:
To investigate the effectiveness of 5G remote robotic surgery in the treatment of pelvic fractures.
METHODS:
A retrospective analysis was conducted on the clinical data of 160 patients with pelvic fractures admitted between July 2023 and June 2024 who met the selection criteria. Among these patients, 80 underwent internal fixation surgery with the assistance of 5G remote robotic surgery (5G group), while 80 received local robotic surgical assistance (control group). Baseline characteristics, including gender, age, body mass index, disease duration, cause of injury, and fracture classification, were compared between the two groups, and no significant difference was found ( P>0.05). The incision length, operation time, intraoperative blood loss, hospital stay, accuracy of screw placement, maximum residual displacement postoperatively, quality of fracture reduction, incidence of complications, Majeed pelvic function score and classification at last follow-up were recorded and compared between the two groups.
RESULTS:
In the 5G group, 180 screws were implanted during surgery, while 213 screws were implanted in the control group. The 5G group demonstrated significantly reduced intraoperative blood loss and shorter incision length compared to the control group ( P<0.05). No significant difference was observed between the two groups in terms of operation time or hospital stay ( P>0.05). Radiographic evaluation revealed excellent and good reduction rates of 98.8% (79/80) in the 5G group and 97.5% (78/80) in the control group, while excellent and good screw placement accuracy rates were 98.3% (177/180) in the 5G group and 95.8% (204/213) in the control group. No significant difference was found between the two groups in maximum residual displacement, reduction quality, or screw placement accuracy ( P>0.05). All patients were followed up 7-16 months (mean, 11.3 months), with no significant difference in follow-up duration between the groups ( P>0.05). No perioperative or follow-up complication, such as wound infection, iatrogenic fractures, iatrogenic neurovascular injury, screw loosening or breakage, or nonunion, were observed in either group. The control group exhibited a worse degree of gait alteration compared to the 5G group ( P<0.05), while no significant difference was found in incidences of squatting limitation or persistent pain ( P>0.05). At last follow-up, no significant difference was observed between the groups in Majeed pelvic function scores or grading ( P>0.05).
CONCLUSION
Compared with the local surgery group, 5G remote robotic surgery supported by remote expert technical guidance demonstrated smaller incision lengths, less intraoperative blood loss, and fewer postoperative complications, and was shown to be a precise, minimally invasive, safe, and reliable surgical method.
Humans
;
Robotic Surgical Procedures/instrumentation*
;
Pelvic Bones/surgery*
;
Male
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Female
;
Fractures, Bone/surgery*
;
Middle Aged
;
Bone Screws
;
Adult
;
Operative Time
;
Treatment Outcome
;
Blood Loss, Surgical
;
Length of Stay
;
Postoperative Complications/epidemiology*
;
Aged
;
Young Adult
9.Feasibility study on measuring anteversion angle of acetabular prosthesis after total hip arthroplasty using arbitrary point method.
Bowen LI ; Longyuan LI ; Heng ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):420-424
OBJECTIVE:
To explore the reliability and accuracy of the arbitrary point method for measuring the anteversion angle of acetabular prosthesis after total hip arthroplasty (THA) based on pelvic X-ray films.
METHODS:
The clinical data of 23 patients (25 hips) who underwent THA between December 2018 and September 2023 and met the selection criteria were retrospectively analyzed. Among them, there were 16 males and 7 females, with an average age of 57.6 years (range, 34-81 years); 13 hips had THA on the left side and 12 on the right side. There were 19 cases (21 hips) of osteonecrosis of the femoral head, 2 cases (2 hips) of femoral neck fractures, 1 case (1 hip) of developmental dysplasia of the hip, and 1 case (1 hip) of osteoarthritis. After THA, all patients underwent X-ray examination and CT scan. Three physicians measured the anteversion angle of acetabular prosthesis using the arbitrary point method and the CT measurement method respectively, and repeated the measurements three times. The results of the two measurement methods were compared, and the intraclass correlation coefficient (ICC) was employed to assess the reproducibility of the methods.
RESULTS:
The anteversion angles of acetabular prosthesis were (15.87±7.73)° measured by the arbitrary point method, and (15.31±7.89)° measured by CT measurement method. There was no significant difference between the two methods ( t=1.515, P=0.143). The ICC of the measurement results by the arbitrary point method for the three physicians were 0.97 ( P<0.001), 0.96 ( P<0.001), and 0.96 ( P<0.001), respectively; and the ICC of the measurement results by CT method were 0.93 ( P<0.001), 0.93 ( P<0.001), and 0.94 ( P<0.001), respectively.
CONCLUSION
The arbitrary point method for measuring the anteversion angle of acetabular prosthesis after THA based on pelvic X-ray film is easy to operate, accurate, and has high reproducibility.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Male
;
Female
;
Aged
;
Middle Aged
;
Hip Prosthesis
;
Acetabulum/surgery*
;
Aged, 80 and over
;
Retrospective Studies
;
Adult
;
Reproducibility of Results
;
Feasibility Studies
;
Tomography, X-Ray Computed
10.Clinical and therapeutic analysis of 22 patients with traumatic spinopelvic dissociation.
Min WU ; Jianzhong GUAN ; Xiaotian CHEN ; Xiaopan WANG ; Peishuai ZHAO ; Yongsheng WANG ; Jiaqiang CHEN ; Leyu LIU ; Renjie LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):692-700
OBJECTIVE:
To review the clinical characteristics of patients with traumatic spinopelvic dissociation (SPD) and explore the diagnostic and therapeutic methods.
METHODS:
A clinical data of 22 patients with SPD who underwent surgical treatment between March 2019 and August 2024 was retrospectively analyzed. There were 13 males and 9 females, with an average age of 35.5 years (range, 14-61 years). The causes of injury included falling from height in 16 cases, traffic accidents in 5 cases, and compression injury in 1 case. Sacral fractures were classified based on morphology into "U" type (9 cases), "H" type (7 cases), "T" type (4 cases), and "λ" type (2 cases). According to the Roy-Camille classification, there were 4 cases of type Ⅰ, 12 cases of type Ⅱ, 2 cases of type Ⅲ, and 4 cases of type Ⅳ. The Cobb angle was (35.7± 22.0)°. Sixteen patients were accompanied by lumbosacral trunk and cauda equina nerve injury, which was classified as grade Ⅱ in 5 cases, grade Ⅲ in 5 cases, and grade Ⅳ in 6 cases according to the Gibbons grading. The time from injury to operation was 2-17 days (mean, 5.7 days). Based on the type of sacral fracture and sacral nerve injury, 6 cases were treated with closed reduction and minimally invasive percutaneous sacroiliac screw fixation, 16 cases were treated with open reduction and lumbar iliac fixation (8 cases)/triangular fixation (8 cases). Among them, 11 patients with severe fracture displacement and kyphotic deformity leading to sacral canal stenosis or bony impingement within the sacral foramen underwent laminectomy and sacral nerve decompression. X-ray films and CT were reviewed during followed-up. The Matta score was used to evaluate the quality of fracture reduction. At last follow-up, the Majeed score was used to assess the functional recovery, and the Gibbons grading was used to evaluate the nerve function.
RESULTS:
All operations were successfully completed. All patients were followed up 8-64 months (mean, 20.4 months). Two patients developed deep vein thrombosis of the lower limbs, 2 had incision infections, and 1 developed a sacral pressure ulcer; no other complications occurred. Radiological examination showed that the Cobb angle was (12.0±6.8)°, which was significantly different from the preoperative one ( t=6.000, P<0.001). The Cobb angle in 16 patients who underwent open reduction was (14.9±5.5)°, which was significantly different from the preoperative one [(46.8±13.9)° ] ( t=8.684, P<0.001). According to the Matta scoring criteria, the quality of fracture reduction was rated as excellent in 8 cases, good in 7 cases, fair in 5 cases, and poor in 2 cases, with an excellent and good rate of 68.2%. Bone callus formation was observed at the fracture site in all patients at 12 weeks after operation, and bony union achieved in all cases at last follow-up, with a healing time ranging from 12 to 36 weeks (mean, 17.6 weeks). At last follow-up, the Majeed score was rated as excellent in 7 cases, good in 10 cases, fair in 4 cases, and poor in 1 case, with an excellent and good rate of 77.3%. One patient experienced a unilateral iliac screw breakage at 12 months after operation, but the fracture had already healed, and there was no loss of reduction. Among the 16 patients with preoperative sacral nerve injury, 11 cases showed improvement in nerve function (6 cases) or recovery (5 cases).
CONCLUSION
SPD with low incidence, multiple associated injuries, and high incidence of sacral nerve injury, requires timely decompression of the sacral canal for symptomatic sacral nerve compression, fractures reduction, deformities correction, and stable fixation.
Humans
;
Adult
;
Female
;
Male
;
Retrospective Studies
;
Middle Aged
;
Spinal Fractures/diagnostic imaging*
;
Adolescent
;
Sacrum/diagnostic imaging*
;
Fracture Fixation, Internal/methods*
;
Young Adult
;
Pelvic Bones/surgery*
;
Treatment Outcome
;
Bone Screws

Result Analysis
Print
Save
E-mail