1.Trends in burden of pelvic fractures from 1990 to 2023 and long short-term memory-based insights into future projections.
Wenbin FAN ; Yueheng YIN ; Chuwei TIAN ; Jun ZHOU ; Tian XIE ; Liu SHI ; Guodong LIU ; Yunfeng RUI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1371-1380
OBJECTIVE:
To analyze the disease burden of pelvic fractures at the global, regional, and national levels from 1990 to 2023 using data from the 2023 Global Burden of Disease Study (GBD), and to predict the disease burden through 2050.
METHODS:
Leveraging data from the GBD 2023, this study investigated the disease burden of pelvic fractures across 204 countries and regions. Assessment indicators included incidence rate, prevalence rate, and years lived with disability (YLDs). The Joinpoint regression model was employed to analyze trends in pelvic fracture burden from 1990 to 2023, while the average annual percentage change (AAPC) was used to quantify this temporal trend. The relationship between the socio-demographic index and pelvic fracture burden was evaluated. Furthermore, the long short-term memory (LSTM) model was applied to predict trends in pelvic fracture burden through 2050.
RESULTS:
In 2023, the estimated number of new pelvic fracture cases globally was 7 479 884 [95% uncertainty interval ( UI): 5 293 401-10 611 876], representing a 42.74% increase from 1990. In the same year, the number of prevalent pelvic fracture cases and YLDs were 23 007 508 (95% UI: 21 021 518-25 327 165) and 3 909 228 person-years (95% UI: 2 725 498-5 194 385), respectively. Additionally, age-standardized rates exhibited an opposing downward trend. Significant disparities in the disease burden of pelvic fractures were identified across different age groups, genders, and social contexts. According to predictions from the LSTM model, the global age-standardized incidence rate (ASIR) of pelvic fractures will be approximately 88.44 per 100 000 persons by 2050, while the total number of incident cases will rise to 8 547 095.
CONCLUSION
Although the overall incidence rate, prevalence rate, and YLDs of pelvic fractures have exhibited an upward trend over the past three decades, the ASIR, age-standardized prevalence rate (ASPR), and age-standardized years of life lost rate (ASYR) have shown a downward trend. It is predicted that over the upcoming 26-year period, the age-standardized rate of disease burden due to pelvic fractures will further decrease, while the number of incident cases and prevalent cases will continue to exhibit an upward trend. Formulating more targeted disease prevention strategies is critical to addressing disparities across genders, regions, and other dimensions, and to mitigating the burden of pelvic fractures.
Humans
;
Fractures, Bone/epidemiology*
;
Pelvic Bones/injuries*
;
Male
;
Female
;
Middle Aged
;
Adult
;
Incidence
;
Prevalence
;
Aged
;
Global Burden of Disease/trends*
;
Global Health
;
Adolescent
;
Cost of Illness
;
Young Adult
;
Forecasting
;
Disability-Adjusted Life Years
;
Memory, Short-Term
2.Effectiveness evaluation of three-dimensional printed customized hemi-pelvic prosthesis for pelvic reconstruction after resection of massive pelvic tumor.
Yuhui SU ; Chao GAO ; Huajian WU ; Zhengwang SUN ; Wangjun YAN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1414-1420
OBJECTIVE:
To investigate the effectiveness of three-dimensional (3D) printed customized hemi-pelvic prosthesis for pelvic reconstruction after resection of massive pelvic tumors.
METHODS:
A retrospective analysis was conducted on 26 patients with massive pelvic tumors who met the selection criteria and were treated between November 2021 and May 2024. The cohort included 11 males and 15 females, with a mean age of 52.65 years (range, 17-73 years). Histopathological diagnoses were as follows: 9 cases of chondrosarcoma, 2 of undifferentiated pleomorphic sarcoma, 4 of spindle cell sarcoma, 2 of osteosarcoma, 1 of solitary fibrous tumor, 1 of myxoid chondroma, 1 of malignant peripheral nerve sheath tumor, 1 of chondromyxoid epithelioma, and 5 of metastatic malignant tumors. According to the Enneking classification, tumor involvement was distributed as 4 cases in zones Ⅰ+Ⅱ, 9 in zones Ⅱ+Ⅲ, 3 in zones Ⅰ+Ⅳ, 8 in zones Ⅰ+Ⅱ+Ⅲ, and 2 in zones Ⅰ+Ⅱ+Ⅳ. The disease duration ranged from 3 to 40 months, with a mean of 9.85 months. All patients underwent reconstruction with customized 3D-printed hemi-pelvic prostheses. The effectiveness was evaluated by Musculoskeletal Tumor Society (MSTS) score and Harris hip score before operation and at last follow-up, and pain levels were evaluated by visual analogue scale (VAS) score before operation, at 3 months after operation, and at last follow-up.
RESULTS:
The operation time ranged from 186 to 528 minutes, with a mean of 334.58 minutes. The intraoperative blood loss ranged from 1 400 to 4 000 mL, with a mean of 2173.08 mL, and the transfusion volume ranged from 750 to 3 500 mL, with a mean of 1 659.62 mL. All 26 patients were followed up 10-42 months (mean, 18.5 months). Postoperative complications included prosthetic dislocation in 2 cases, which were attributed to improper positioning during home care and an accidental fall, respectively. One patient developed a vesicocutaneous fistula and poor wound healing due to pre-existing tumor invasion into the bladder. One patient experienced failure and loosening of the internal fixation at 8 months after operation caused by local tumor recurrence, and subsequently died at 14 months postoperatively due to progression of brain metastases. Postoperative complications such as poor healing of incisions, prosthetic dislocation, or failure of internal fixation was not observed in the remaining patients. At last follow-up, the walking ability of most patients recovered to varying degrees. The VAS scores at 3 months and at last follow-up significantly improved when compared with those before operation, and the scores at last follow-up further improved when compared with 3 months after operation, all showing significant differences ( P<0.05). The MSTS scores and Harris scores at last follow-up were significantly higher than those before operation ( P<0.05).
CONCLUSION
3D printed customized hemi-pelvic prosthesis is effective for reconstruction of massive pelvic tumors after resection, but there are still some limitations, and soft tissue reconstruction should be paid attention to.
Humans
;
Printing, Three-Dimensional
;
Female
;
Male
;
Adult
;
Plastic Surgery Procedures/methods*
;
Retrospective Studies
;
Middle Aged
;
Aged
;
Pelvic Bones/surgery*
;
Bone Neoplasms/surgery*
;
Adolescent
;
Pelvic Neoplasms/surgery*
;
Prosthesis Design
;
Young Adult
;
Treatment Outcome
;
Prostheses and Implants
3.TiRobot-assisted minimally invasive treatment of geriatric fragility fractures of the pelvis.
Canhui LI ; Yonghong DAI ; Weiqiong CAI ; Xiaopeng SITU ; Yanhui ZENG ; Xuelian DU ; Shi HONG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1421-1427
OBJECTIVE:
To investigate the effectiveness of TiRobot-assisted minimally invasive treatment for fragility fractures of the pelvis (FFP) in elderly patients.
METHODS:
A retrospective analysis was conducted on the clinical data of 176 patients with FFP who were admitted between July 2018 and July 2024 and met the selection criteria. Among them, 95 patients underwent TiRobot-assisted closed reduction and minimally invasive cannulated screw fixation (robot group), while 81 patients underwent traditional open reduction and plate screw fixation (control group). There was no significant difference in baseline data such as gender, age, fracture classification, disease duration, and preoperative visual analogue scale (VAS) pain scores between the two groups ( P>0.05). The following parameters were recorded and compared between the two groups, including operation time, intraoperative blood loss, intraoperative transfusion rate, volume of intraoperative blood transfusion, maximum incision length, hospital stay, maximum residual displacement, reduction quality, fracture healing time, incidence of complications, VAS scores, Majeed pelvic function scores, and functional grading.
RESULTS:
All surgeries in both groups successfully completed. The robot group exhibited significantly shorter operation time, reduced intraoperative blood loss, lower intraoperative transfusion rate, smaller volume of intraoperative blood transfusion, shorter maximum incision length, and shorter hospital stay compared to the control group ( P<0.05). In the robot group, a total of 14 INFIX internal fixation frames and 280 cannulated screws were implanted, among which 250 screws were rated as excellent, 17 as good, and 13 as poor, resulting in a screw placement excellent and good rate of 95.36%. Radiological review revealed that the excellent and good rate of reduction quality was in 91.58% (87/95) in the robot group and 81.48% (66/81) in the control group, with no significant difference in postoperative maximum residual fracture displacement or reduction quality between the two groups (P>0.05). All patients in both groups were followed up 12-66 months, with an average of 28.9 months, and there was no significant difference in follow-up time between the two groups ( P>0.05). The fracture healing time in the robot group was significantly shorter than that in the control group ( P<0.05). At last follow-up, both groups showed significant improvement in VAS scores compared to preoperative values ( P<0.05); the change values of VAS scores, Majeed scores, and the excellent and good rate of Majeed pelvic function were significantly higher in the robot group than in the control group ( P<0.05). Regarding postoperative complications, there was no significant difference between the two groups in terms of gait changes, secondary surgeries, heterotopic ossification, incision infections, walking difficulties, internal fixation failure, or mortality rates ( P>0.05); however, the incidence of delayed wound healing was significantly lower in the robot group than in the control group ( P<0.05).
CONCLUSION
TiRobot-assisted minimally invasive treatment of elderly FFP is superior to traditional open reduction and internal fixation in terms of surgical trauma control, postoperative rehabilitation speed, and functional recovery.
Humans
;
Male
;
Retrospective Studies
;
Female
;
Minimally Invasive Surgical Procedures/instrumentation*
;
Fracture Fixation, Internal/instrumentation*
;
Pelvic Bones/surgery*
;
Aged
;
Bone Screws
;
Bone Plates
;
Robotic Surgical Procedures/methods*
;
Aged, 80 and over
;
Treatment Outcome
;
Osteoporotic Fractures/surgery*
;
Operative Time
;
Blood Loss, Surgical
;
Fracture Healing
;
Fractures, Bone/surgery*
4.Early follow-up study on three-dimensional-printed customized porous acetabular components for reconstructing extensive acetabular bone defects in primary total hip arthroplasty.
Shangkun TANG ; Zhuangzhuang LI ; Xin HU ; Linyun TAN ; Hao WANG ; Yitian WANG ; Minxun LU ; Fan TANG ; Yi LUO ; Yong ZHOU ; Chongqi TU ; Li MIN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1543-1550
OBJECTIVE:
To evaluate the feasibility and short-term effectiveness of three-dimensional (3D)-printed customized porous acetabular components for reconstruction of extensive acetabular bone defects during primary total hip arthroplasty (THA).
METHODS:
The clinical data of 8 patients with extensive acetabular bone defects, who were treated with 3D-printed individualized porous acetabular components between July 2018 and January 2022, were retrospectively analyzed. The cohort comprised 4 males and 4 females with an average age of 48 years ranging from 34 to 56 years. Acetabular bone defects were classified as Paprosky type ⅢA in 3 cases and type ⅢB in 5 cases. The causes of acetabular destruction were hip tuberculosis (5 cases), pigmented villonodular synovitis (2 cases), and syphilitic arthritis (1 case). Visual analogue scale (VAS) score and Harris hip score (HHS) were used to evaluate the pain relief and hip function before and after operation. Reconstruction outcomes were further assessed by imaging results [X-ray film and Tomosynthesis Shimadzumetal artefact reduction technology (T-SMART)], and the mechanical properties were evaluated by finite element analysis.
RESULTS:
The operation time ranged from 174 to 195 minutes (mean, 187 minutes), and intraoperative blood loss ranged from 390 to 530 mL (mean, 465 mL). All 8 patients were follow-up 26-74 months (mean, 44 months). Among the 5 patients with tuberculosis, none experienced postoperative recurrence. At last follow-up, the VAS score was 0.3±0.5 and the HHS score was 87.9±3.7, both significantly improved compared to preoperative values ( t=25.170, P<0.001; t=-28.322, P<0.001). X-ray films at 2 years after operation demonstrated satisfactory matching between the 3D-printed customized acetabular component and the acetabulum. The postoperative center of rotation of the operated hip was shifted by (2.1±0.5) mm horizontally and (2.0±0.7) mm vertically relative to the contralateral side, with both offsets showing significant differences compared to preoperative values ( t=24.700, P<0.001; t=55.230, P<0.001). T-SMART imaging showed satisfactory osseointegration at the implant-host bone interface. No complications such as aseptic loosening or screw breakage was observed during follow-up. Finite element analysis showed that the acetabular component had good mechanical properties.
CONCLUSION
The application of 3D-printed individualized porous acetabular components in the reconstruction of extensive acetabular bone defects demonstrated precise anatomical reconstruction, stable mechanical support, and good functional performance in short-term follow-up, offering a potential alternative for acetabular defect reconstruction in primary THA.
Humans
;
Middle Aged
;
Male
;
Female
;
Printing, Three-Dimensional
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Acetabulum/diagnostic imaging*
;
Adult
;
Follow-Up Studies
;
Retrospective Studies
;
Hip Prosthesis
;
Prosthesis Design
;
Porosity
;
Treatment Outcome
;
Plastic Surgery Procedures/methods*
5.Effectiveness of arthroscopic treatment for femoroacetabular impingement syndrome combined with ligamentum teres injury.
Siyu HAN ; Song LI ; Di JIA ; Yanlin LI ; Guofeng CAI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1551-1555
OBJECTIVE:
To investigate the effectiveness of hip arthroscopy in the treatment of patients with femoroacetabular impingement (FAI) syndrome combined with ligamentum teres injury.
METHODS:
A retrospective analysis was conducted on 23 patients (23 hips) with Cam-type FAI syndrome combined with ligamentum teres injury who met the selection criteria between April 2022 and May 2024. The cohort included 12 males and 11 females, with a mean age of 29.16 years (range, 16-57 years). According to Tönnis classification, there were 5 cases of grade 0, 10 cases of grade Ⅰ, and 8 cases of grade Ⅱ in hip osteoarthritis. The disease duration ranged from 6 to 24 months, with an average of 12 months. Under hip arthroscopy, hypertrophic synovium and the damaged ligamentum teres were debrided, while the torn labrum and cartilage were repaired, and femoral head-neck osteoplasty was performed to eliminate impingement, restore the normal morphology of the acetabulum and femoral head-neck, and suture the joint capsule. Acetabular lateral center-edge angle (LCEA) and α angle (reflecting the degree of non-sphericity at the femoral head-neck junction) were measured before and after operation, and the modified Harris hip score (mHHS), the International Hip Outcome Tool-12 (IHOT-12), and the visual analogue scale (VAS) score for pain were evaluated.
RESULTS:
The operation was successfully completed in all patients. The incisions healed by first intention after operation, and there was no perioperative complications such as iatrogenic cartilage injury, fracture, infection, neurovascular traction injury, or lower extremity venous thrombosis. All the 23 patients were followed up 12-24 months, with an average of 14.6 months. The pain of hip joint significantly relieved, and the function of hip joint improved; no complication such as joint stiffness, joint instability, and osteonecrosis of the femoral head occurred. The α angle, VAS score, mHHS score, and IHOT-12 score at last follow-up were significantly better than those before operation ( P<0.05); there was no significant difference in LCEA compared to preoperative value ( P>0.05).
CONCLUSION
Hip arthroscopy is a safe and effective treatment for patients with FAI syndrome combined with ligamentum teres injury, which can achieve satisfactory effectiveness.
Humans
;
Femoracetabular Impingement/complications*
;
Arthroscopy/methods*
;
Adult
;
Male
;
Female
;
Retrospective Studies
;
Middle Aged
;
Adolescent
;
Treatment Outcome
;
Young Adult
;
Hip Joint/surgery*
;
Acetabulum/surgery*
;
Round Ligaments/surgery*
;
Range of Motion, Articular
6.Clinical application of three-dimensional printing technology combined with customized bone plate in the treatment of acetabulum fracture.
Yan-Chao ZANG ; Quan-Yong ZHAO ; Li YANG ; Jin-Zeng ZUO ; Wei QI ; Wei-Dong LIANG ; Jie XING
China Journal of Orthopaedics and Traumatology 2025;38(2):203-207
OBJECTIVE:
To explore the application value and clinical effect of 3D printing combined with customized bone plate in the treatment of acetabular fracture.
METHODS:
From June 2020 to June 2022, 11 patients with acetabular fractures underwent preoperative planning using 3D printing technology and were treated with customized bone plates including 8 males and 3 females, aged 25 to 66 years old. The fractures were classified according to Letournel-Judet:4 posterior wall fractures, 2 T-type fractures, 2 transverse posterior wall fractures, 2 double column fractures, and 1 anterior column with posterior semi-transverse fractures. The operative time, intraoperative blood loss, intraoperative fluoroscopy times, postoperative drainage volume, postoperative fracture healing time, and hip function score were recorded and analyzed.
RESULTS:
The operation time of 11 patients was 80 to 150 min, intraoperative blood volume was 150 to 700 ml, fluoroscopy frequency was 2 to 6, postoperative drainage flow was 60 to 195 ml, and the fracture healing time was 2.5 to 6.0 months. Fracture reduction was evaluated according to Matta score:anatomical reduction in 3 cases and satisfactory reduction in 8 cases. Eleven patients were followed up for 7 to 18 months. The hip Merle d'Aubigne function scores were excellent in 6 cases, good in 3 cases, fair in 1 case and poor in 1 case. Incision fat liquefaction occurred in 1 case and obturator nerve traction in 1 case.
CONCLUSION
The application of 3D printing technology combined with customized bone plates in the treatment of acetabular fracture is effective. In addition, the printed model can provide the operator with the results of the three-dimensional shape of the fracture, which is convenient for surgical reduction and effectively improves the efficiency of surgery.
Humans
;
Female
;
Male
;
Middle Aged
;
Acetabulum/surgery*
;
Printing, Three-Dimensional
;
Adult
;
Aged
;
Bone Plates
;
Fractures, Bone/surgery*
;
Fracture Fixation, Internal/methods*
7.Arthroscopic high strength suture fixation of iliac bone mass for the treatment of shoulder joint forward instability with high risk of dislocation.
China Journal of Orthopaedics and Traumatology 2025;38(3):252-257
OBJECTIVE:
To explore clinical effect of iliac bone graft fixed with high strength suture arthroscopy in treating shoulder joint forward instability with high risk of dislocation.
METHODS:
The clinical data of 22 patients with shoulder forward instability with high risk of dislocation treated with iliac bone graft fixed with high-strength suture arthroscopy from January 2021 to January 2023 were retrospectively analyzed, including 14 males and 8 females, aged from 17 to 46 years old with an average of (26.50±8.26) years old;the times of dislocation ranged from 4 to 22 (11.08±5.82) times;7 patients on the left side and 15 patients on the right side. American Shoulder and Elbow Surgeons (ASES) score, University of California at Los Angeles (UCLA) score and Constant-Murley score were to evaluate the improvement of shoulder joint function before operation and 12 months after operation. Three-dimensional CT reconstruction was performed to evaluate the repair of glenoid bone defect, bone remodeling and bone healing before operation, immediately after and 12 months after operation.
RESULTS:
All patients were followed up for 12 to 24 months with an average of (18.68±3.92) months. No further dislocation or subluxation occurred in all patients. Scores of ASES, UCLA and Constant-Murley were improved from (69.50±2.26), (23.86±2.27), (75.64±3.58) before operation to (91.09±1.57), (32.27±2.03), (91.95±3.00) at 12 months after operation (P<0.05). The defect of glenoid bone was (12.41±7.55) %, (-37.23±3.75) %, (-22.41±3.58) % before opertaion, immediately and 12 months after operation, respectively, and the difference was statistically significant (P<0.05). Bone healing of iliac bone graft was achieved at 12 months after operation.
CONCLUSION
High strength suture arthroscopy to fix iliac bone graft for the treatment of shoulder forward instability with high dislocation risk is a safe and effective method, which could effectively restore shoulder stability and reduce surgical injury.
Humans
;
Male
;
Female
;
Adult
;
Arthroscopy/methods*
;
Middle Aged
;
Ilium/transplantation*
;
Adolescent
;
Joint Instability/physiopathology*
;
Shoulder Dislocation/surgery*
;
Shoulder Joint/physiopathology*
;
Young Adult
;
Retrospective Studies
;
Bone Transplantation
;
Sutures
8.Digital study of IdebergⅡregional pelvic fracture anatomical plate based on 3D metal printing technology.
Yi ZHANG ; Jia-Kai ZHANG ; Jun-Long WU ; Yi ZHENG
China Journal of Orthopaedics and Traumatology 2025;38(3):293-297
OBJECTIVE:
To establish digital model of Ideberg typeⅡregional glenoid fracture anatomical plate with 3D metal printing technology.
METHODS:
The scapular imaging data of a 34-year-old healthy male volunteer were retrospectively selected. Mimics 15.01, NX 12.0 and other software were used to design Ideberg typeⅡ regional scapular fracture guide plate system. STL data were input into a metal 3D printer to print 1∶1 scapular model and anatomical plate of scapular pelvis with guide sleeve. The fit of the plate was tested in vitro and the accuracy of the screw position was evaluated by imaging. The printing time of scapular model, design of the nail path and making time of the anatomic guided plate were recorded.
RESULTS:
3D metal-printed Ideberg typeⅡ guide plate for scapular fracture fitted well to 3D printed scapular model, the locking screw was oriented accurately, and X-ray and CT showed good screw position. The printing time of scapula model, time of nail path design and special-shaped anatomical guide plate production were 52.0, 15.0 and 320 min, respectively.
CONCLUSION
Anatomical plates based on 3D metal printing technology could achieve good adhesion of Ideberg typeⅡ regional fractures and precise screw placement, providing a new and accurate surgical method for the treatment of Ideberg typeⅡ glenoid fractures.
Humans
;
Printing, Three-Dimensional
;
Male
;
Adult
;
Bone Plates
;
Fractures, Bone/diagnostic imaging*
;
Fracture Fixation, Internal/methods*
;
Pelvic Bones/surgery*
;
Metals
;
Scapula/surgery*
;
Models, Anatomic
9.Comparison of two transforaminal endoscopic techniques for recurrent L5S1 lumbar disc herniation with high iliac crest.
Yue-Hong GUAN ; Jian WU ; Li-Jun WANG ; Bin XU ; Jian TANG ; Ying ZHANG ; Ying-Qi HE
China Journal of Orthopaedics and Traumatology 2025;38(11):1100-1105
OBJECTIVE:
To explore the clinical efficacy of conventional transforaminal endoscopic technique and I See transforaminal endoscopic technique in the treatment of recurrent L5S1 lumbar disc herniation with high iliac crest.
METHODS:
A total of 36 patients with recurrent L5S1 lumbar disc herniation with high iliac crest after posterior small-incision discectomy, admitted from May 2016 to May 2023, were selected. They were divided into the conventional transforaminal endoscopy group and the I See transforaminal endoscopy group according to the different transforaminal endoscopic techniques adopted, and all patients in both groups underwent lateral transforaminal spinal canal decompression and discectomy. There were 18 patients in the conventional transforaminal endoscopy group, including 11 males and 7 females, with an age of (52.24±6.68) years;the I See transforaminal endoscopy group also had 18 patients, including 12 males and 6 females, with an age of (50.75±7.79) years. The perioperative indicators (operation time, number of intraoperative radiographs, and length of hospital stay) were compared between two groups. The clinical efficacy was evaluated using the visual analogue scale(VAS) for pain, the Japanese Orthopaedic Association(JOA) low back pain score, and the modified MacNab criteria before and after surgery.
RESULTS:
All patients achieved gradeⅠincision healing, with no infection cases. The operation time of the I See group was (64.25±16.67) minutes, which was significantly shorter than that of the conventional transforaminal endoscopy group (89.11±17.24) minutes, and the difference was statistically significant(P<0.05). The number of intraoperative radiographs in the I See group was (5.20±2.29) times, which was significantly less than that in the conventional transforaminal endoscopy group(19.16±3.68) times, and the difference was statistically significant(P<0.05). The VAS and total JOA scores of both groups at the 3rd day, the 3rd month after surgery, and the last follow-up were significantly lower than those before surgery, with statistically significant differences(P<0.05);however, there were no statistically significant differences in VAS and total JOA scores between two groups at the 3rd day, the 3rd month after surgery, and the last follow-up (P>0.05). According to the modified MacNab criteria for efficacy evaluation:in the conventional transforaminal endoscopy group, 14 cases were excellent and 4 cases were good;in the I See transforaminal endoscopy group, 15 cases were excellent and 3 cases were good;there was no statistically significant difference in efficacy between two groups(Z=0.177, P=0.674).
CONCLUSION
Both transforaminal endoscopic techniques have good clinical effects in the treatment of recurrent L5S1 lumbar disc herniation with high iliac crest, resulting in significant improvement of postoperative symptoms, and they are safe, reliable, and minimally invasive surgical methods. Compared with the conventional transforaminal endoscopy, the I See transforaminal endoscopic technique has shorter operation time and fewer intraoperative radiographs, so it is generally the first choice.
Humans
;
Male
;
Female
;
Intervertebral Disc Displacement/surgery*
;
Endoscopy/methods*
;
Middle Aged
;
Lumbar Vertebrae/surgery*
;
Ilium/surgery*
;
Adult
;
Diskectomy/methods*
10.Comparison of curettage vs. trephination technique for harvesting anterior iliac crest bone graft: A cadaveric study.
Albert CAKAR ; Omer Faruk EGERCI ; Fırat DOGRUOZ ; Ersin TASATAN ; Serra OZTURK ; Muzaffer SINDEL ; Ozkan KOSE
Chinese Journal of Traumatology 2025;28(2):151-156
PURPOSE:
The purpose of this cadaveric study was to compare the volume and weight of bone graft harvested using the curettage vs. the trephination technique from the anterior iliac crest.
METHODS:
Embalmed cadavers were studied in this experimental research. The right hemipelvis of each cadaver was used for the trephine bone harvesting technique, whereas the left hemipelvis was used for the conventional curettage technique. The weight and the volume of the harvested bone were measured and statistically compared between the 2 sides. The Wilcoxon Signed-Rank test was employed to compare the graft volume and weight obtained from the right and left sides of the hemipelvis.
RESULTS:
Ten embalmed adult cadavers were used in this study. All subjects were Caucasian males with a mean age of 59.8 years (range 44 - 73 years) at the time of death. A total of 81 cylindrical bone grafts were harvested from the right iliac crest. In 9 out of 81 (11.1%), the cortex of the ilium was penetrated by the chisel. The mean weight of the bone graft harvested with the trephine technique (26.97 ± 2.32) g was heavier than that harvested with the curettage technique (23.74 ± 2.09) g (p = 0.007). Similarly, the volume of the bone graft was higher in the trephine technique (8.40 ± 0.84) cm3 compared to the curettage technique (6.60 ± 1.26) cm3 (p = 0.011). The trephination technique lasted a mean of (12.76 ± 1.87) min (range 10.30-16.10 min), while the curettage technique lasted a mean of (14.53 ± 0.89) min (range 13.50-16.00 min) (p = 0.028).
CONCLUSION:
Harvesting anterior iliac crest bone graft with the trephine technique provides a higher bone volume and weight than the conventional curettage technique. The trephine technique might be advocated over the curettage technique, especially when a large amount of autologous bone graft is required. However, a meticulous harvesting technique should be followed to prevent complications. In particular, the three-dimensional anatomy should be kept in mind, and the depth of trephination should be well-controlled.
CLINICAL TRIAL REGISTRATION
Institutional Review Board registration: 2022/499.
Humans
;
Ilium/surgery*
;
Male
;
Middle Aged
;
Aged
;
Cadaver
;
Curettage/methods*
;
Tissue and Organ Harvesting/methods*
;
Bone Transplantation/methods*
;
Adult
;
Trephining/methods*

Result Analysis
Print
Save
E-mail