1.Fabrication and research of gelatin-based tissue mimicking material phantom with wall-less blood vessels for ultrasound applications
Hongwei LI ; Peikai WU ; Zixu XU ; Xinye NI
Chinese Journal of Medical Physics 2025;42(11):1507-1513
Objective To fabricate wall-less vascular tissue mimicking materials(TMM)with different tube diameters that match the hemodynamic parameters of human carotid arteries,and to investigate their hemodynamic characteristics.Methods TMM with different diameters and blood mimicking fluids containing scattering particles were fabricated.The variation laws of hemodynamic parameters under different flow velocities and TMM phantom diameters were verified.Key hemodynamic parameters including peak systolic velocity(PSV),end-diastolic velocity(EDV),and resistance index were measured using Doppler ultrasound,and their clinical application value in carotid artery diseases was evaluated.Results The fabricated samples exhibited a sound velocity of(1506.2±0.1)m/s and an attenuation of(0.76±0.01)dB/cm,and the vascular diameters were 4.0 and 6.0 mm,which corresponded to the normal clinical range of the external and internal carotid arteries,respectively.For the 4.0 mm TMM,both PSV and EDV were linearly correlated with flow velocity(R2=0.77,P<0.001;R2=0.74,P=0.001),and Pearson correlation analysis confirmed strong positive correlations(r=0.89,95%CI:0.82-0.93;r=0.94,95%CI:0.90-0.97,all P<0.001).For the 6.0 mm TMM,PSV and EDV also demonstrated significant linear correlations with flow velocity(R2=0.70,P=0.001;R2=0.61,P=0.005),with Pearson correlation analysis revealing strong positive correlations(r=0.86,95%CI:0.78-0.91;r=0.79,95%CI:0.68-0.87).All the data were consistent with hemodynamic parameters and followed the variation law of hemodynamic parameters.Conclusion The fabricated TMM and blood mimicking fluids meet the requirements for clinical ultrasound research on hemodynamics,and their material ratios can be used as a reference for the subsequent researches with diverse objectives.
2.Fabrication and research of gelatin-based tissue mimicking material phantom with wall-less blood vessels for ultrasound applications
Hongwei LI ; Peikai WU ; Zixu XU ; Xinye NI
Chinese Journal of Medical Physics 2025;42(11):1507-1513
Objective To fabricate wall-less vascular tissue mimicking materials(TMM)with different tube diameters that match the hemodynamic parameters of human carotid arteries,and to investigate their hemodynamic characteristics.Methods TMM with different diameters and blood mimicking fluids containing scattering particles were fabricated.The variation laws of hemodynamic parameters under different flow velocities and TMM phantom diameters were verified.Key hemodynamic parameters including peak systolic velocity(PSV),end-diastolic velocity(EDV),and resistance index were measured using Doppler ultrasound,and their clinical application value in carotid artery diseases was evaluated.Results The fabricated samples exhibited a sound velocity of(1506.2±0.1)m/s and an attenuation of(0.76±0.01)dB/cm,and the vascular diameters were 4.0 and 6.0 mm,which corresponded to the normal clinical range of the external and internal carotid arteries,respectively.For the 4.0 mm TMM,both PSV and EDV were linearly correlated with flow velocity(R2=0.77,P<0.001;R2=0.74,P=0.001),and Pearson correlation analysis confirmed strong positive correlations(r=0.89,95%CI:0.82-0.93;r=0.94,95%CI:0.90-0.97,all P<0.001).For the 6.0 mm TMM,PSV and EDV also demonstrated significant linear correlations with flow velocity(R2=0.70,P=0.001;R2=0.61,P=0.005),with Pearson correlation analysis revealing strong positive correlations(r=0.86,95%CI:0.78-0.91;r=0.79,95%CI:0.68-0.87).All the data were consistent with hemodynamic parameters and followed the variation law of hemodynamic parameters.Conclusion The fabricated TMM and blood mimicking fluids meet the requirements for clinical ultrasound research on hemodynamics,and their material ratios can be used as a reference for the subsequent researches with diverse objectives.
3.Construction and Application of Management Information System Based on TCM Coding System
Liping LIAO ; Peikai WU ; Meiqu XU ; Yihua LV ; Xiongwei TANG ; Yuanyan ZHU
Chinese Journal of Information on Traditional Chinese Medicine 2016;23(10):13-15
Through analyzing the existing problems and relevant solutions of TCM decoction pieces management, this article expounded the construction of TCM coding system and its construction and application in the hospital information system, attempted to apply technological standards of TCM coding system to routine TCM standardized management work through the means of informatization. At the same time, it also described the basic situation in the construction of TCM coding management information system, and promoted specific ideas, operation methods, and current condition and prospects.

Result Analysis
Print
Save
E-mail