1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Research advances in small-molecule hydrophobic tagging protein degraders
Zirui HUO ; Jieyu PEI ; Fangyi ZHAN ; Shaowen XIE ; Jinyi XU ; Shengtao XU
Journal of China Pharmaceutical University 2025;56(2):252-263
In In recent years, small-molecule targeted protein degraders inducing protein degradation have been developing rapidly. These molecules are attracting substantial interest from researchers since they can overcome such limitations of traditional small-molecule inhibitors as their inapplicability to ‘undruggable’ targets and tendency to induce drug resistance. Compared with other targeted protein degraders, small-molecule hydrophobic tags (HyTs) may have a smaller number of hydrogen bond donors/acceptors, smaller molecular weights, and better pharmacokinetic profiles, thus attracting extensive attention from researchers. This review focuses on the possible mechanisms and popular types of HyTs, with special attention to the potential application value of adamantane, a typical hydrophobic tag, in the fields of cancer and neurodegeneration. In general, there are still some problems like fewer types of hydrophobic tags and insufficient research on degradation mechanisms, which still need to be further explored. This review is expected to provide researchers working in the fields of small-molecule targeted protein degraders with some valuable reference.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Mitochondrial Transfer Promotes Immune Escape in Osteosarcoma Cells: Mechanisms and Research Advances
Qishun QIN ; Xingsheng WANG ; Kai LI ; Pei PENG ; Shihong XU
Medical Journal of Peking Union Medical College Hospital 2025;16(5):1250-1259
Osteosarcoma is a highly aggressive malignant bone tumor whose immuno evasion mechanisms play a pivotal role in tumor progression and therapeutic resistance. Recent studies have identified mitochondrial transfer as a novel mode of intercellular communication that significantly influences metabolic reprogramming and immune evasion in osteosarcoma cells. This mechanism operates through three principal pathways: (1) enhancing energy metabolic efficiency in tumor cells; (2) mitigating intracellular oxidative stress; and (3) modulating immune checkpoint molecule expression. Collectively, these alterations impair host immune surveillance while promoting tumor proliferation, invasion, and distant metastasis through metabolic remodeling, immune tolerance induction, and tumor microenvironment reconstruction. This review systematically elucidates the molecular mechanisms by which mitochondrial transfer regulates immune evasion in osteosarcoma and its dynamic impact on the tumor microenvironment. Furthermore, we discuss the translational potential of targeting this pathway for precision therapy and outline future research directions in this emerging field.
8.Associations of serum peroxisome proliferator-activated receptor-γ coactivator-1α with cerebral microbleeds and their severity in patients with cerebral small vessel disease
International Journal of Cerebrovascular Diseases 2024;32(5):344-348
Objective:To investigate associations of serum peroxisome proliferator-activated receptor-γ coactivator-1α (PGC-1α) with cerebral microbleeds (CMBs) and their severity in patients with cerebral small vessel disease (CSVD).Methods:Consecutive patients with CSVD admitted to the Department of Neurology, the Second Affiliated Hospital of Nantong University and the Eighth People's Hospital of Tongzhou District, Nantong from August 2022 to August 2023 were prospectively included. According to the MRI findings, patients were divided into non-CMB group and CMB group, with the latter further divided into mild CMB group (1-2), moderate CMB group (3-10), and severe CMB group (>10). Multivariate logistic regression analysis was used to identify the independent correlation factors of CMBs. Multiple linear regression analysis was used to identify the correlation between serum PGC-1α and the number of CMBs. Results:A total of 158 patients with CSVD were included, of which 96 (60.8%) had CMBs; among them, 55 patients had mild CMBs, 24 had moderate CMBs, and 17 had severe CMBs. The PGC-1α and white blood cell count in the CMB group were significantly lower than those in the non-CMB group, while age, platelet count, triglycerides, fasting blood glucose, and glycated hemoglobin were significantly higher than those in the non-CMB group (all P<0.05). Multivariate logistic regression analysis showed that after adjusting for the confounding variables such as age, fasting blood glucose, and white blood cell count, PGC-1α was an independent protective factor for CMBs in patients with CSVD (odds ratio 0.588, 95% confidence interval 0.415-0.833; P=0.003). Multiple linear regression analysis showed a significant negative correlation between serum PGC-1α and the number of CMBs ( β=-0.566, P<0.001). Conclusion:Serum PGC-1α is associated with CMBs and their severity in patients with CSVD; the higher the serum PGC-1α, the lower the likelihood of the presence of CMBs.
9.Characteristic spectrum of Rheum tanguticum Maxim,ex Balf.water decoction and analysis of different origins and different processed products
Kaiwei HUANG ; Hui ZHANG ; Shuping XU ; Huiling YANG ; Yanghua LI ; Weizhi ZHAO ; Zhijun GUO ; Pei TAN
Drug Standards of China 2024;25(4):330-338
Objective To establish an ultra-high liquid chromatography(UPLC)characteristic spectrum of Rheum tanguticum Maxim.ex Balf.water decoction and conduct chemical pattern recognition analysis,and to identify the medicinal materials of different origins and different processed products.Methods:UPLC was adopted to establish the characteristic spectra of 15 batches of Rheum tanguticum Maxim.ex Balf.Cluster analysis combined with principal component analysis was used to analyze their quality.Rhei Radix et Rhizoma from different origins and different processed products of Rheum tanguticum Maxim.ex Balf.were identified.Results:The characteristic spectrum of Rheum tanguticum Maxim.ex Balf.water decoction was established,18 common peaks were identi-fied,and 15 batches of Rheum tanguticum Maxim.ex Balf.were divided into 2 categories according to their origins by cluster analysis.The similarity between 15 batches of samples from different origins and the control spectrum was greater than 0.900.According to OPLS-DA analysis,a total of 6 markers(rhein-8-O-β-D-glu-cosid,resveratrol-4'-O-β-D-(6''-O-D-gallyl)glucopyranside,isolindleyin,rhein,epicatechin-3-O-D-gallate,and catechin)affecting the quality of Rheum tanguticum Maxim.ex Balf.water decoction samples were found.Rhei Radix et Rhizoma from different origins and different processed products of Rheum tanguticum Maxim.ex Balf.can be effectively distinguished.Conclusion:The established characteristic spectrum method is easy to operate and has good repeatability.It can be used for the quality control of Rheum tanguticum Maxim.ex Balf.water decoction,and can provide reference for the formulation of quality standard of formula granules of Rhei Radix et Rhizoma.
10.Orthopaedic robot assisted closed reduction and cannulated screw internal fixation for the treatment of femoral neck fractures
Shou-Hai JIANG ; Chuan-Kai ZHANG ; Fang-Teng JIA ; Qiang CHEN ; Meng XU ; Pei-Lin YANG ; Yu-Shuai ZHANG
China Journal of Orthopaedics and Traumatology 2024;37(2):119-123
Objective To investigate the preliminary clinical effect of closed reduction and cannulated nail internal fixa-tion for femoral neck fracture assisted by robot navigation and positioning system.Methods From July 2019 to January 2020,16 cases of femoral neck fracture(navigation group)were treated with closed reduction and internal fixation guided by robot system,including 7 males and 9 females,aged 25 to 72 years old with an average of(53.61±5.45)years old;Garden classification of fracture:3 cases of type Ⅰ,3 cases of type Ⅱ,8 cases of type Ⅲ,2 cases of type Ⅳ.Non navigation group(control group):20 cases of femoral neck fracture were treated with closed reduction and hollow nail internal fixation,8 males and 12 females,aged 46 to 70 years old with an average of(55.23±4.64)years old;Garden type Ⅰ in 2 cases,type Ⅱ in 4 cases,type Ⅲ in 11 cases,type Ⅳ in 3 cases.The operation time,fluoroscopy times,guide needle drilling times,screw adjustment times,intraoperative bleeding volume and other indicators of two groups were evaluated.Results Both groups were followed up for 12 to 18 months with an average of(15.6±2.8)months.The fractures of both groups were healed without delayed union and nonunion.There was no significant difference in healing time between two groups(P=0.782).There was no significant differ-ence in Harris scores between two groups at the last follow-up(P=0.813).There was no significant difference in operation time between two groups(P>0.05).There were significant differences between two groups in fluoroscopy times,guide needle drilling times,hollow screw replacement times,and intraoperative bleeding volume(P<0.05).Conclusion Closed reduction and hollow screw internal fixation assisted by robot navigation system for femoral neck fracture has the advantages of minimally invasive operation,precise screw placement,and reduction of X-ray radiation damage during operation.

Result Analysis
Print
Save
E-mail