1.Risk Factors for Prolonged Postoperative Length of Stay After Hip Fracture Surgery in Very Elderly Patients.
Bo-Wen XU ; Wei-Yun CHEN ; Chen SUN ; Ling LAN ; Lu-Lu MA ; Li-Jian PEI
Chinese Medical Sciences Journal 2025;40(2):111-119
OBJECTIVES:
To identify risk factors contributing to prolonged postoperative length of stay (LOS) in very elderly patients following hip fracture surgery, with a focus on postoperative complications and the impact of different anesthesia approaches.
METHODS:
This retrospective single-center cohort study enrolled patients aged 90 years or older who underwent hip fracture surgery at Peking Union Medical College Hospital between January 31, 2013 and December 31, 2023. Relevant perioperative data were collected. The primary outcome was postoperative LOS, and the study cohort was divided into two groups: postoperative LOS ≤ 7 days and LOS > 7 days. Logistic regression was performed to identify factors related to prolonged postoperative LOS.
RESULTS:
A total of 155 patients were included. The average age was 92.7 ± 2.6 years. There were 73 (47%) patients with postoperative LOS > 7 days. Postoperative pneumonia was the only factor associated with a prolonged postoperative LOS (OR = 2.12, 95% CI [1.09, 4.16], P = 0.028). Neither the type of anesthesia (regional vs. general anesthesia, OR = 1.00, 95% CI [0.53, 1.90], P = 0.993) nor the method of airway management (laryngeal mask ventilation vs. spontaneous breathing, OR = 1.46, 95% CI [0.58, 3.76], P = 0.424; endotracheal intubation vs. spontaneous breathing, OR = 0.82, 95% CI [0.39, 1.69], P = 0.592) showed a significant association with a prolonged postoperative LOS. Preoperative chronic obstructive pulmonary disease (OR = 2.78, 95% CI [1.05, 7.65], P = 0.040) and preoperative neutrophil count (OR = 1.13, 95% CI [1.01, 1.26], P = 0.029) were both significantly associated with the occurrence of postoperative pneumonia, while anesthesia type and airway management method were not.
CONCLUSIONS
Postoperative pneumonia was associated with prolonged postoperative LOS in very elderly patients undergoing hip fracture surgery, whereas anesthesia types and airway management methods show no association with prolonged postoperative LOS or postoperative pneumonia. Preoperative comorbidities, especially respiratory conditions and systemic inflammation, potentially play a substantial role in postoperative recovery.
Humans
;
Hip Fractures/surgery*
;
Aged, 80 and over
;
Risk Factors
;
Length of Stay
;
Female
;
Male
;
Retrospective Studies
;
Postoperative Complications/etiology*
2.Correlation between bone mass loss and incidence of knee osteoarthritis in the elderly community-based population.
Chen-Jie XIA ; Jin LI ; Xiang LI ; Ke ZHOU ; Liang FANG ; Hong-Ting JIN ; Pei-Jian TONG
China Journal of Orthopaedics and Traumatology 2025;38(4):358-363
OBJECTIVE:
To explore the epidemiological characteristics of knee osteoarthritis (KOA) among the elderly in the community, and its correlation with bone mass loss.
METHODS:
A cross-sectional study was conducted on elderly community population over 50 year old from 12 community health service centers in Zhejiang province. Their gender, age, body mass index (BMI), T value and KOA diagnosis were collected using face to face questionnaire survey. Univariate regression was used to analyze the influence of age, gender, BMI and bone loss on KOA. Logistic multivariate regression model was used to analyze the independent effect of bone mass loss on KOA.
RESULTS:
Among 4 173 subjects in this study, 1 710 of them were had a KOA. The prevalence rate was 40.9%. The mean age, the proportion of females and the mean BMI in KOA patients were (65.5±3.8) years old, 67.7%(1 158/1 710) and(24.59±1.28) kg·m-2, respectively, which were significantly higher than (58.5±3.2) years old, 51.3%(1 263/2 463), and (23.48±1.25) kg·m-2 in non-KOA subjects (P<0.001). In the population aged from 60 to 69 years old, the influence of osteopenia and osteoporosis on the prevalence of KOA was[OR=1.21, 95%CI(1.00, 1.46), P=0.053 2], [OR=1.42, 95%CI(1.14, 1.78), P=0.002 2]. The influence of male and female osteoporosis on the prevalence of KOA was [OR=1.52, 95%CI(1.16, 1.99), P=0.002 7] and [OR=1.87, 95%CI(1.51, 2.32), P<0.000 1], respectively. In the population of 24 kg·m-2≤BMI<28 kg·m-2, the influence of osteopenia and osteoporosis on the prevalence of KOA was [OR=1.47, 95%CI(1.21, 1.80), P=0.000 1], [OR=2.69, 95%CI(2.11, 3.42), P<0.000 1], respectively. After controlling the confounding factors of age, gender and BMI, compared with people with normal bone mass, the effect of osteopenia on the prevalence of KOA was [OR=1.34, 95%CI(1.08, 1.67), P=0.009 2], and the effect of osteoporosis on the prevalence of KOA was [OR=1.38, 95%CI(1.06, 1.79), P=0.017 9].
CONCLUSION
Elderly overweight women are more likely to develop KOA. Bone mass loss is an independent risk factor for KOA, which will significantly increase the prevalence of KOA in people overweight or aged 60 to 69 years old.
Humans
;
Female
;
Male
;
Aged
;
Osteoarthritis, Knee/etiology*
;
Middle Aged
;
Cross-Sectional Studies
;
Bone Density
;
Aged, 80 and over
;
Incidence
;
Body Mass Index
;
China/epidemiology*
;
Osteoporosis/epidemiology*
3.Triangular Wave tACS Improves Working Memory Performance by Enhancing Brain Activity in the Early Stage of Encoding.
Jianxu ZHANG ; Jian OUYANG ; Tiantian LIU ; Xinyue WANG ; Binbin GAO ; Jinyan ZHANG ; Manli LUO ; Anshun KANG ; Zilong YAN ; Li WANG ; Guangying PEI ; Shintaro FUNAHASHI ; Jinglong WU ; Jian ZHANG ; Tianyi YAN
Neuroscience Bulletin 2025;41(7):1213-1228
Working memory is an executive memory process that includes encoding, maintenance, and retrieval. These processes can be modulated by transcranial alternating current stimulation (tACS) with sinusoidal waves. However, little is known about the impact of the rate of current change on working memory. In this study, we aimed to investigate the effects of two types of tACS with different rates of current change on working memory performance and brain activity. We applied a randomized, single-blind design and divided 81 young participants who received triangular wave tACS, sinusoidal wave tACS, or sham stimulation into three groups. Participants performed n-back tasks, and electroencephalograms were recorded before, during, and after active or sham stimulation. Compared to the baseline, working memory performance (accuracy and response time) improved after stimulation under all stimulation conditions. According to drift-diffusion model analysis, triangular wave tACS significantly increased the efficiency of non-target information processing. In addition, compared with sham conditions, triangular wave tACS reduced alpha power oscillations in the occipital lobe throughout the encoding period, while sinusoidal wave tACS increased theta power in the central frontal region only during the later encoding period. The brain network connectivity results showed that triangular wave tACS improved the clustering coefficient, local efficiency, and node degree intensity in the early encoding stage, and these parameters were positively correlated with the non-target drift rate and decision starting point. Our findings on how tACS modulates working memory indicate that triangular wave tACS significantly enhances brain network connectivity during the early encoding stage, demonstrating an improvement in the efficiency of working memory processing. In contrast, sinusoidal wave tACS increased the theta power during the later encoding stage, suggesting its potential critical role in late-stage information processing. These findings provide valuable insights into the potential mechanisms by which tACS modulates working memory.
Humans
;
Memory, Short-Term/physiology*
;
Male
;
Female
;
Young Adult
;
Transcranial Direct Current Stimulation/methods*
;
Brain/physiology*
;
Adult
;
Electroencephalography
;
Single-Blind Method
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Carbon footprint accounting of traditional Chinese medicine extracts based on life cycle assessment: a case study of mulberry leaf extract from an enterprise.
Zhi-Min CI ; Jian-Xiang OU ; Qiang YU ; Chuan ZHENG ; Zhao-Qing PEI ; Li-Ping QU ; Ming YANG ; Li HAN ; Ding-Kun ZHANG
China Journal of Chinese Materia Medica 2025;50(1):120-129
Under the background of carbon peaking and carbon neutrality goals, the Ministry of Ecology and Environment, together with 15 national ministries and commissions, has formulated the Implementation Plan on Establishing a Carbon Footprint Management System, and it is urgent for traditional Chinese medicine(TCM) pharmaceutical enterprises to carry out research on carbon footprint accounting methods of related products. Based on the life cycle assessment(LCA) theory, taking mulberry leaf extract produced by a certain enterprise as an example, this study analyzed the carbon footprint of TCM extracts during the life cycle. The results show that for every 1 kg of product produced, the carbon emissions from the stages of raw material acquisition, transportation, and extract production are-20.569, 1.205, and 173.577 kgCO_2eq(CO_2 equivalent), respectively. The carbon footprint of the product is 154.213 kgCO_2eq·kg~(-1). In addition, the carbon emission is the highest in the production stage, in which the consumption of ethanol solvents makes the greatest contribution to the carbon footprint, accounting for 25.71%, more than one-fourth of the total carbon footprint. The second contribution was from the treatment process of TCM residues, accounting for 19.67%, closely followed by wastewater treatment(17.71%), the consumption of hot steam(17.43%), and drinking water(16.90%). The consumption of electric power and packaging materials has a smaller carbon emission of 2.58%. In particular, the carbon emission caused by the consumption of packaging materials is only 0.04%, which is negligible. The results of the study are expected to provide a reference for TCM enterprises to carry out research on the carbon footprint of products, offer ideas for collaborative innovation in reducing pollution and carbon emissions throughout the entire industry chain of TCM, and develop new quality productivity of modern TCM industry based on green and low-carbon manufacturing.
Morus/chemistry*
;
Plant Leaves/chemistry*
;
Carbon Footprint
;
Drugs, Chinese Herbal/chemistry*
;
Plant Extracts/analysis*
;
Medicine, Chinese Traditional
10.Yougui Pills inhibit oxidative stress-induced damage of granulosa cells by regulating Keap1/Nrf2 signaling pathway via Serpina3k.
Bei-Bei JIAO ; Tian LI ; Bei-Bei ZHOU ; Si CHEN ; Yue CHEN ; Jian ZHANG ; Pei-Juan WANG
China Journal of Chinese Materia Medica 2025;50(4):1111-1120
To investigate the effects and mechanisms of Yougui Pills(YGP) on oxidative damage induced by hydrogen peroxide(H_2O_2) in human ovarian granulosa cells(KGN). The components in serum with low-and high-doses of YGP were analyzed and compared through ultra-high performance liquid chromatography-quadrupole electrostatic field orbitrap mass spectrometry(UHPLC-QEMS), and selected the serum containing YGP high-dose group to follow-up experiments. To stimulated KGN with 200 μmol·L~(-1) H_2O_2to establish an oxidative damage model, which was divided into normal group, model group, low-, medium-, and high-dose of YGP groups, and the efficacy was further verified on the basis of silencing or overexpressing serine protease inhibitor(Serpina3k), further validating the efficacy based on the silencing or overexpression of Serpina3k. TUNEL staining was used to detect cell apoptosis,enzyme-linked immunosorbent assay(ELISA) was employed to measure the secretion levels of estradiol(E_2) and 17β-E_2 in KGN, and Western blot was utilized to assess the expression of Serpina3k and proteins related to the Keap1/Nrf2 signaling pathway. The results show that compared to the model group, each dose group of YGP not only significantly reduces granulocyte apoptosis and upregulates the secretion levels of E_2 and 17β-E_2, but also significantly upregulates Serpina3k and Nrf2 pathway. Further research has found that overexpression of Serpina3k not only enhances the therapeutic effect of YGP but also increases the expression of Nrf2 and inhibits the expression of Keap1. Conversely, interfering with Serpina3k partially reverses the therapeutic effect of YGP, while also partially. The results indicate that the mechanism by which YGP improves oxidative stress in KGN may be related to its upregulation of Serpina3k expression, which affects the conduction of the Keap1/Nrf2 signaling pathway. This study reveals the mechanism by which YGP protects granular cells, providing a certain theoretical basis for its clinical application.
NF-E2-Related Factor 2/genetics*
;
Kelch-Like ECH-Associated Protein 1/genetics*
;
Humans
;
Female
;
Signal Transduction/drug effects*
;
Oxidative Stress/drug effects*
;
Granulosa Cells/cytology*
;
Drugs, Chinese Herbal/pharmacology*
;
Apoptosis/drug effects*
;
Serpins/genetics*

Result Analysis
Print
Save
E-mail