1.Impact of ischemia time and storage periods on RNA quality of fresh-frozen breast cancer and esophageal cancer tissue samples in biobank
Yang-si ZHENG ; Xuan-hao LIN ; Fan LI ; Kun-sheng XIAO ; Xi-feng CHEN ; Chun-peng LIU ; Pei-xiu YAO ; Shao-hong WANG
Fudan University Journal of Medical Sciences 2025;52(3):437-445
Objective To investigate the effects of ischemia time and storage periods on RNA quality in fresh-frozen breast cancer(BC)and esophageal cancer(EC)tissue samples in order to establish evidence-based protocols for biobank sample management.Methods The tumor(T)and paired normal(N)tissue samples from 6 cases of BC and 6 cases of EC were collected and cryopreserved in Biobank,Shantou Central Hospital.Mirror paraffin-embedded tissues were simultaneously prepared into sections for morphological analysis.The samples were divided into two groups of<15 min and 15-30 min according to ischemia time,and RNA quality was analyzed at 4 storage periods of 8-10 months(T1),14-16 months(T2),26-28 months(T3)and 38-40 months(T4).Results In 96 analyzed samples,93.8%(90/96)exhibited high quality(RIN≥6),with 89.6%(43/48)in BC and 97.9%(47/48)in EC.Significant differences in RIN were observed between BC group and EC group(8.050 vs.8.600,P=0.009).In EC group,RIN value was significantly negatively correlated with RNA yield(P<0.001).Moreover,RIN values of tumor-normal pairs exhibited markedly significant differences(7.550 vs.9.000,P<0.001).In contrast,no significant difference was detected in BC group(8.200 vs.7.700,P=0.348).Statistical analysis showed that RIN value was positively correlated with 28S/18S(P<0.001),but had no correlation with tumor content(P=0.676)and necrotic content(P=0.055).Neither ischemia time(<15 min vs.15-30 min:8.200 vs.8.300,P=0.932)nor storage periods(T1-T4:8.400,7.700,8.450,8.600,P=0.163)compromised RNA quality.Conclusion Organ origin and tissue type could influence RNA quality of fresh-frozen tissue samples.However,limited ischemia time(≤30 min)and long-term storage period(38-40 months)do not adversely affect RNA quality in fresh-frozen breast cancer and esophageal cancer tissue samples.
2.Impact of ischemia time and storage periods on RNA quality of fresh-frozen breast cancer and esophageal cancer tissue samples in biobank
Yang-si ZHENG ; Xuan-hao LIN ; Fan LI ; Kun-sheng XIAO ; Xi-feng CHEN ; Chun-peng LIU ; Pei-xiu YAO ; Shao-hong WANG
Fudan University Journal of Medical Sciences 2025;52(3):437-445
Objective To investigate the effects of ischemia time and storage periods on RNA quality in fresh-frozen breast cancer(BC)and esophageal cancer(EC)tissue samples in order to establish evidence-based protocols for biobank sample management.Methods The tumor(T)and paired normal(N)tissue samples from 6 cases of BC and 6 cases of EC were collected and cryopreserved in Biobank,Shantou Central Hospital.Mirror paraffin-embedded tissues were simultaneously prepared into sections for morphological analysis.The samples were divided into two groups of<15 min and 15-30 min according to ischemia time,and RNA quality was analyzed at 4 storage periods of 8-10 months(T1),14-16 months(T2),26-28 months(T3)and 38-40 months(T4).Results In 96 analyzed samples,93.8%(90/96)exhibited high quality(RIN≥6),with 89.6%(43/48)in BC and 97.9%(47/48)in EC.Significant differences in RIN were observed between BC group and EC group(8.050 vs.8.600,P=0.009).In EC group,RIN value was significantly negatively correlated with RNA yield(P<0.001).Moreover,RIN values of tumor-normal pairs exhibited markedly significant differences(7.550 vs.9.000,P<0.001).In contrast,no significant difference was detected in BC group(8.200 vs.7.700,P=0.348).Statistical analysis showed that RIN value was positively correlated with 28S/18S(P<0.001),but had no correlation with tumor content(P=0.676)and necrotic content(P=0.055).Neither ischemia time(<15 min vs.15-30 min:8.200 vs.8.300,P=0.932)nor storage periods(T1-T4:8.400,7.700,8.450,8.600,P=0.163)compromised RNA quality.Conclusion Organ origin and tissue type could influence RNA quality of fresh-frozen tissue samples.However,limited ischemia time(≤30 min)and long-term storage period(38-40 months)do not adversely affect RNA quality in fresh-frozen breast cancer and esophageal cancer tissue samples.
3.Construction of a theoretical framework for factors influencing the use of intravenous therapy specialist nurses based on grounded theory
Shengxiao NIE ; Kui SONG ; Yanfen SHEN ; Jingli KOU ; Pei WANG ; Lei LI ; Kaili ZHANG ; Hong SUN
Chinese Journal of Modern Nursing 2025;31(33):4497-4505
Objective:To explore the influencing factors of the use of intravenous therapy specialist nurses and construct a theoretical framework, so as to provide reference for developing intervention measures and improving the use of intravenous therapy specialist nurses.Methods:The grounded theory research method was used. From July to August 2024, 17 intravenous therapy managers/specialist nurses from six ClassⅢ Grade A hospitals in Beijing City and Hebei Province were selected through purposive and theoretical sampling for semi-structured interviews. NVivo 12.0 was used for data analysis, including open, axial, and selective coding.Results:A total of 79 initial concepts were extracted and summarized into 25 domains, which were consolidated into five main domains, including organizational management and support, personal characteristics and professional identity, team collaboration and communication, work performance and incentive mechanisms, and external environment and opportunities. On this basis, a theoretical framework for factors influencing the use of intravenous therapy specialist nurses was constructed.Conclusions:This study constructs a theoretical framework for factors influencing the use of intravenous therapy specialist nurses. Managers can leverage this theoretical framework to develop targeted intervention strategies that enhance the effectiveness of intravenous therapy specialist nurses and optimize the allocation of nursing human resources.
4.Design of performance testing platfrom for proportional solenoid valves in ventilators
Long-ying YE ; Ming-kang TANG ; Pei-pei ZHANG ; Ke-sheng WANG ; Dan LING ; Qian-hong HE
Chinese Medical Equipment Journal 2025;46(1):13-19
Objective To design a performance testing platform to evaluate the working status and performance characteristics of the ventilator proportional solenoid valve.Methods The performance testing platform had its hardware including a high-pressure gas source,a pressure regulating valve,sensors and etc,and its software designed based on PyQt5 and composed of several modules for data acquisition,parameter setting,image display,indicator computation,result output and etc.Two kinds of proportional solenoid valves(Valve 1、Valve2)were selected for static and dynamic tests to verify the performance of the platform.Results The platform developed facilitated the proportional solenoid valve to carry out accurate computation of static and dynamic indicators at real time and time domain and waveform feature extraction of sensor data by precision control and data acquisition for the proportional solenoid valve.Static tests showed that Valve 1 gained advantages over Valve 2 in static flow characteristics involving in lowered repeatability,return error and offset while enhanced stability;dynamic tests indicated Valve 2 had rapid flow variations and significant flow fluctuation impacts,Valve 1 showed smooth dynamic response changes,and Valve 2 behaved better than Valve 1 in dynamic performance.Conclusion The testing platform developed comprehensively demonstrates the performance characteristics and working performance of the ventilator proportional solenoid valve,which is of great significance to enhance the reliability and safety of the ventilator.[Chinese Medical Equipment Journal,2025,46(1):13-19]
5.Current status of field(emergency)rapid inspection systems
Pei-pei WANG ; Yu-hong HUANG ; Jing LI ; Wen REN ; Shi-chao LIANG ; Yu-qi QIAN ; Yan-jiang LIU
Chinese Medical Equipment Journal 2025;46(2):80-86
The field(emergency)rapid inspection systems involving in the backpack,chest,vehicle and shelter had their research advances introduced and characteristics and deficiencies analyzed,and some improvement suggestions were put forward accordingly.It's pointed out the backpack,chest,vehicle and shelter be combined effectively to enhance the mobility and flexibility of field(emergency)rapid inspection systems.References were provided for the future enhancement and effecient operation of field(emergency)rapid inspection systems.[Chinese Medical Equipment Journal,2025,46(2):80-86]
6.Construction of a theoretical framework for factors influencing the use of intravenous therapy specialist nurses based on grounded theory
Shengxiao NIE ; Kui SONG ; Yanfen SHEN ; Jingli KOU ; Pei WANG ; Lei LI ; Kaili ZHANG ; Hong SUN
Chinese Journal of Modern Nursing 2025;31(33):4497-4505
Objective:To explore the influencing factors of the use of intravenous therapy specialist nurses and construct a theoretical framework, so as to provide reference for developing intervention measures and improving the use of intravenous therapy specialist nurses.Methods:The grounded theory research method was used. From July to August 2024, 17 intravenous therapy managers/specialist nurses from six ClassⅢ Grade A hospitals in Beijing City and Hebei Province were selected through purposive and theoretical sampling for semi-structured interviews. NVivo 12.0 was used for data analysis, including open, axial, and selective coding.Results:A total of 79 initial concepts were extracted and summarized into 25 domains, which were consolidated into five main domains, including organizational management and support, personal characteristics and professional identity, team collaboration and communication, work performance and incentive mechanisms, and external environment and opportunities. On this basis, a theoretical framework for factors influencing the use of intravenous therapy specialist nurses was constructed.Conclusions:This study constructs a theoretical framework for factors influencing the use of intravenous therapy specialist nurses. Managers can leverage this theoretical framework to develop targeted intervention strategies that enhance the effectiveness of intravenous therapy specialist nurses and optimize the allocation of nursing human resources.
7.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
8.Effects of Yiqi Juanbi Formula on chondrocyte pyroptosis in collagen-induced arthritic rats via NF-κB/NLRP3/Caspase-1 signaling pathway
Xin-yu CUI ; Hao-lin LI ; Wei-qing LI ; Hui-qin KANG ; Wei-gang CHENG ; Pei-xin HE ; Cai-hong YANG ; Ping CHEN ; Hai-dong WANG
Chinese Traditional Patent Medicine 2025;47(9):2880-2887
AIM To investigate the effects of Yiqi Juanbi Formula on chondrocyte pyroptosis in rat models of collagen-induced arthritis(CIA).METHODS Fifty rats were subcutaneously injected at the tail base with an emulsion containing equal volumes of bovine type Ⅱ collagen and incomplete Freund's adjuvant(IFA)to establish the CIA models.These rats were then randomly assigned to the model group,the methotrexate group(0.35 mg/kg),and the low-dose,medium-dose,and high-dose Yiqi Juanbi Formula groups(9.4,18.7,37.4 g/kg),in contrast to the ten intact rats serving in the normal control group.Following four weeks of intragastric administration,the rats had their general conditions observed;their joint swelling and arthritis indices measured;their ankle joint pathology assessed by HE staining;their serum levels of IL-1β,IL-18 and TNF-ɑ detected by ELISA;their mRNA expressions of NLRP3,Caspase-1,GSDMD,IL-1β,IL-18 and TNF-ɑ in ankle cartilage quantified by RT-qPCR;their protein expressions of NF-κB,NLRP3 and Caspase-1 in ankle cartilage analyzed by Western blot;and their NLRP3 and GSDMD positive expressions in ankle cartilage examined by immunohistochemistry.RESULTS Compared to the control group,the model group showed significantly increased joint swelling and arthritis indices(P<0.01);elevated serum levels of IL-1 β,IL-18 and TNF-ɑ(P<0.01);pathological changes including cartilage surface defects,reduced cell count,altered cellular morphology,irregular cell arrangement,and significant inflammatory cell infiltration in synovial tissue;upregulated mRNA expressions of NF-κB,NLRP3,Caspase-1,GSDMD,IL-1β,IL-18 and TNF-ɑ(P<0.01)and increased protein expressions of NF-κB,NLRP3 and Caspase-1(P<0.01)in ankle cartilage;enhanced positive expressions of NLRP3 and GSDMD in ankle cartilage(P<0.01).Compared to the model group,the groups intervened with methotrexate or medium-or high-dose Yiqi Juanbi Formula exhibited reduced joint swelling and arthritis indices(P<0.01);alleviated pathological damage in ankle joints;decreased serum levels of IL-1β,IL-18 and TNF-ɑ(P<0.01);downregulated mRNA expressions of NF-κB,NLRP3,Caspase-1,GSDMD,IL-1β,IL-18 and TNF-ɑ(P<0.05,P<0.01),and reduced protein expressions of NF-κB,NLRP3 and Caspase-1(P<0.05,P<0.01)in ankle cartilage;and diminished positive expressions of NLRP3 and GSDMD in ankle cartilage(P<0.01).CONCLUSION Yiqi Juanbi Formula alleviates inflammation in CIA rats,potentially by inhibiting the activation of the NF-κB/NLRP3/Caspase-1 signaling pathway,thereby suppressing chondrocyte pyroptosis.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail