1.Comparative study of MS-39, Sirius, and Pentacam in assisting size selection of implantable collamer lens
Jiaqi YUE ; Xindi WANG ; Yimeng FAN ; Zhao LIU ; Cheng PEI
International Eye Science 2025;25(9):1505-1510
AIM: To assess the consistency of the new anterior segment analyzer, MS-39, the Sirius and Pentacam in measuring corneal white-to-white(WTW)and central anterior chamber depth(ACD), and to compare their differences in guiding implantable collamer lens(ICL)size selection.METHODS: Retrospective case study. A total of 210 consecutive patients(420 eyes)who treated at the Ophthalmology Refractive Surgery Center of the First Affiliated Hospital of Xi'an Jiaotong University between September 2019 and September 2020 were enrolled. Three anterior segment analysis systems, MS-39, Sirius, and Pentacam, were utilized to assess the WTW and ACD, with comparative analysis of the results. The sizing of the ICL V4c was simulated using the method recommended by the STAAR company. Data correlation and consistency were evaluated.RESULTS: The WTW measurement results obtained from MS-39, Sirius, and Pentacam were 11.39±0.35, 11.42±0.36, and 11.46±0.35 mm, respectively. Notably, the WTW measurement value from MS-39 was significantly lower than that from Pentacam(P=0.002), while no statistically significant differences were observed between MS-39 and Sirius, or between Sirius and Pentacam(all P>0.05). The WTW measurements from the three devices exhibited a strong positive correlation, with correlation coefficients(r)of 0.942 between MS-39 and Sirius, 0.925 between MS-39 and Pentacam, and 0.882 between Sirius and Pentacam(all P<0.0001). The ACD measurements values from the MS-39, Sirius and Pentacam were 3.28±0.22, 3.28±0.24, and 3.21±0.23 mm, respectively. While, no statistically significant difference was found between MS-39 and Sirius(P>0.05), both measurements were significantly higher than that of Pentacam(both P<0.0001). The ACD measurements also demonstrated a strong positive correlation, with r values of 0.959 between MS-39 and Sirius, 0.947 between MS-39 and Pentacam, and 0.932 between Sirius and Pentacam(all P<0.0001). In terms of ICL size selection based on the measurements from the three devices, the 12.6 mm size was the most frequently selected, while the 13.7 mm size was the least common, the distribution of size selections across the devices was similar.CONCLUSION: MS-39 demonstrated strong positive correlation with both Sirius and Pentacam for WTW and ACD measurements, indicating that the results can be considered clinically interchangeable. Furthermore, the outcomes derived from MS-39 for ICL size selection were closely aligned with those from Sirius and Pentacam, suggesting its clinical feasibility.
2.The addition of 5-aminolevulinic acid to HBSS protects testis grafts during hypothermic transportation: a novel preservation strategy.
Meng-Hui MA ; Pei-Gen CHEN ; Jun-Xian HE ; Hai-Cheng CHEN ; Zhen-Han XU ; Lin-Yan LV ; Yan-Qing LI ; Xiao-Yan LIANG ; Gui-Hua LIU
Asian Journal of Andrology 2025;27(4):454-463
The aim of this investigation was to determine the optimal storage medium for testicular hypothermic transportation and identify the ideal concentration for the application of the protective agent 5-aminolevulinic acid (5-ALA). Furthermore, this study aimed to explore the underlying mechanism of the protective effects of 5-ALA. First, we collected and stored mouse testicular fragments in different media, including Hank's balanced salt solution (HBSS; n = 5), Dulbecco's Modified Eagle Medium/Nutrient Mixture F-12 (DMEM/F12; n = 5), and alpha-minimum essential medium (αMEM; n = 5). Storage of testicular tissue in HBSS preserved the integrity of testicular morphology better than that in the DMEM/F12 group ( P < 0.05) and the αMEM group ( P < 0.01). Testicular fragments were subsequently placed in HBSS with various concentrations of 5-ALA (0 [control], 1 mmol l -1 , 2 mmol l -1 , and 5 mmol l -1 ) to determine the most effective concentration of 5-ALA. The 2 mmol l -1 5-ALA group ( n = 3) presented the highest positive rate of spermatogonial stem cells compared with those in the control, 1 mmol l -1 , and 5 mmol l -1 5-ALA groups. Finally, the tissue fragments were preserved in HBSS with control ( n = 3) and 2 mmol l -1 5-ALA ( n = 3) under low-temperature conditions. A comparative analysis was performed against fresh testes ( n = 3) to elucidate the underlying mechanism of 5-ALA. Gene set enrichment analysis (GSEA) for WikiPathways revealed that the p38 mitogen-activated protein kinase (MAPK) signaling pathway was downregulated in the 2 mmol l -1 5-ALA group compared with that in the control group (normalized enrichment score [NES] = -1.57, false discovery rate [FDR] = 0.229, and P = 0.019). In conclusion, these data suggest that using 2 mmol l -1 5-ALA in HBSS effectively protected the viability of spermatogonial stem cells upon hypothermic transportation.
Male
;
Animals
;
Testis/cytology*
;
Aminolevulinic Acid/pharmacology*
;
Mice
;
Organ Preservation/methods*
;
Organ Preservation Solutions/pharmacology*
;
Cryopreservation/methods*
3.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
4.Oral Herombopag Olamine and subcutaneous recombinant human thrombopoietin after haploidentical hematopoietic stem cell transplantation
Dai KONG ; Xinkai WANG ; Wenhui ZHANG ; Xiaohang PEI ; Cheng LIAN ; Xiaona NIU ; Honggang GUO ; Junwei NIU ; Zunmin ZHU ; Zhongwen LIU
Chinese Journal of Tissue Engineering Research 2025;29(1):1-7
BACKGROUND:Allogeneic hematopoietic stem cell transplantation is an important treatment for malignant hematological diseases,and delayed postoperative platelet implantation is a common complication that seriously affects the quality of patient survival;however,there are no standard protocols to improve platelet implantation rates and prevent platelet implantation delays. OBJECTIVE:To compare the safety and efficacy of oral Herombopag Olamine versus subcutaneous recombinant human thrombopoietin for promoting platelet implantation in patients with malignant hematological diseases undergoing haploid hematopoietic stem cell transplantation. METHODS:Clinical data of 163 patients with malignant hematological diseases who underwent haploidentical hematopoietic stem cell transplantation from January 2016 to October 2022 were retrospectively analyzed.A total of 72 patients who started to subcutaneously inject recombinant human thrombopoietin at+2 days were categorized into the recombinant human thrombopoietin group;a total of 27 patients who started to orally take Herombopag Olamine at+2 days were categorized into the Herombopag Olamine group;and 64 patients who did not apply Herombopag Olamine or recombinant human thrombopoietin were categorized into the blank control group.The implantation status,incidence of acute graft-versus-host disease of degree II-IV within 100 days,1-year survival rate,1-year recurrence rate,and safety were analyzed in the three groups. RESULTS AND CONCLUSION:(1)The average follow-up time was 52(12-87)months.The implantation time of neutrophils in the blank control group,recombinant human thrombopoietin group,and Herombopag Olamine group was(12.95±3.88)days,(14.04±3.71)days,and(13.89±2.74)days,respectively,with no statistically significant difference(P=0.352);the implantation time of platelets was(15.16±6.27)days,(17.67±6.52)days,and(17.00±4.75)days,with no statistically significant difference(P=0.287).(2)The complete platelet implantation rate on day 60 was 64.06%,90.28%,and 92.59%,respectively,and the difference was statistically significant(P<0.001).The subgroup analysis showed that the difference between the blank control group and the recombinant human thrombopoietin group was statistically significant(P<0.001),and the difference between the blank control group and the Herombopag Olamine group was statistically significant(P=0.004).The difference was not statistically significant between the recombinant human thrombopoietin group and Herombopag Olamine group(P=0.535).(3)100-day II-IV degree acute graft-versus-host disease incidence in the blank control group,recombinant human thrombopoietin group,and Herombopag Olamine group were 25.00%,30.56%,and 25.93%,respectively,and the difference was not statistically significant(P=0.752).(4)The incidence of cytomegalovirus anemia,cytomegalovirus pneumonia,and hepatic function injury had no statistical difference among the three groups(P>0.05).(5)During the follow-up period,there was no thrombotic event in any of the three groups of patients.(6)The results showed that recombinant human thrombopoietin and Herombopag Olamine could improve the platelet implantation rate of malignant hematological disease patients after haploidentical hematopoietic stem cell transplantation,with comparable efficacy and good safety.
5.Treatment plan optimization for intensity-modulated brachytherapy based on the conjugate gradient algorithm
Miao QI ; Junyi LIU ; Shijun LI ; Yankui CHANG ; Jieping ZHOU ; Bing YAN ; Yong CHENG ; Aidong WU ; Xi PEI ; Xie XU
Chinese Journal of Radiological Medicine and Protection 2025;45(1):56-62
Objective:To investigate the application of the conjugate gradient (CG) algorithm to treatment plan optimization for intensity-modulated brachytherapy (IMBT).Methods:The general Monte Carlo software TOPAS was utilized to simulate the 192Ir source of IMBT, and the unit dose contribution matrix was calculated. An objective function was established using the weighted least squares method and was solved using the CG algorithm to achieve optimized IMBT treatment plans. The optimization was validated using five clinical cervical cancer cases under modulation width 60°. The dose distributions of IMBT treatment plans under 45°, 60°, 90°, 120°, and 180° modulation widths were compared using the Wilcoxon test to determine the optimal IMBT treatment plan for cervical cancer treatment. Results:The CG algorithm successfully optimized IMBT treatment plans under modulation width 60° for five cases within 22.2 s on average. On the premise of sufficient target dose coverage, the average D2 cm 3 values of the bladder and rectum in IMBT treatment plans were 3.66 and 1.97 Gy, respectively, representing reductions of 0.54 and 0.69 Gy compared to traditional brachytherapy plans. For the five modulation widths, the D90% values of all IMBT treatment plans reached 6 Gy, without statistically significant differences ( P > 0.05). The average D2 cm 3 values of the bladder in IMBT treatment plans were significantly lower than those in the traditional brachytherapy plans( P<0.05), with modulation width 60° associated with the greatest reduction of 0.61 Gy. In contrast, the average D2 cm 3 values of the rectum under 45°, 60°, and 90° modulation widths decreased by 0.63, 0.54, and 0.45 Gy, respectively, compared to traditional plans, with statistically significant differences( P<0.05). Conclusions:The CG method enables rapid achievement of optimized IMBT treatment plans that meet clinical requirements, and modulation width 60° contributes to valid dosimetric optimization. This study can serve as a guide for the clinical implementation of IMBT.
6.Key technology and equipment development status of first-aid robotics
Zhen-bao WANG ; Zi-jian WANG ; Xin-xi XU ; Xin LIU ; Tao CHENG ; Pei-peng LIU ; Xiu-guo ZHAO ; Chen SU
Chinese Medical Equipment Journal 2025;46(3):96-114
The development status of the key technologies of first-aid robotics was introduced in autonomous system,embo-died intelligence,digital twins,large artificial intelligence model and autonomous unmanned medical treatment.The present situation in first-aid robotics equipment was reviewed for first-aid diagnosis,treatment,assistance and transportation.The development trends of the key technology and equipment of first-aid robotics were analyzed.It was pointed out the involve-ment of big model-based embodied intelligence technology and digital twins technology in first aid might provide new pers-pectives for the application and advancement of specialized first-aid robotics.[Chinese Medical Equipment Journal,2025,46(3):96-114]
7.Comparison of efficacy and safety of defocus incorporated soft contact lenses versus orthokeratology in myopic children with different baseline characteris-tics
Xinxin LU ; Cheng PEI ; Lu YE ; Jiaqi WANG ; Zhirong LIU ; Wenjun WANG
Recent Advances in Ophthalmology 2025;45(11):897-901
Objective To compare the efficacy and safety of defocus incorporated soft contact lenses(DISC)and orthokeratology(Ortho-K)for myopia control in children aged 8~15 years,and to further investigate the influence of dif-ferent baseline age and spherical equivalent(SE)on the treatment effect.Methods A retrospective cohort study was conducted,involving 197 myopic children(197 eyes)aged 8~15 years who were fitted with contact lenses at the Depart-ment of Ophthalmology,Xi'an People's Hospital(Xi'an Fourth Hospital)from May to September 2023.They were divid-ed into the DISC group(97 cases)and the Ortho-K group(100 cases).After 12 months of continuous follow-up,the chan-ges in axial length(AL)at 3,6,and 12 months after lens wear were compared between the two groups.Subgroup analysis was then performed:participants were divided into a younger subgroup(8~10 years)and an older subgroup(11~15 years)based on pre-wear age,and into a low myopia subgroup(-1.00~-3.00 D)and a moderate myopia subgroup(-3.25~-6.00 D)based on pre-wear SE.The AL changes at 3,6,and 12 months after wearing DISC or Ortho-K were com-pared between groups within these subgroups.Meanwhile,the incidence of conjunctivitis,incidence of corneal staining,corneal endothelial cell density,and corneal thickness were compared between the two groups at 12 months after lens wear.Results Inter-group comparisons showed:The change in AL in the DISC group at 3 months after lens wear was significantly lower than that in the Ortho-K group,and the difference was statistically significant(P<0.05);at 6 and 12 months after lens wear,the differences in AL change between the two groups were not statistically significant(both P>0.05).Subgroup analysis by age and SE showed:In the younger subgroup and the low myopia subgroup,the AL change in the DISC group at 3 months after lens wear was significantly lower than that in the Ortho-K group,and the differences were statistically significant(both P<0.05),but these differences disappeared at 6 and 12 months after lens wear(all P>0.05);in the older subgroup and the moderate myopia subgroup,the differences in AL change between the two groups at 3,6,and 12 months after lens wear were not statistically significant(all P>0.05).At 12 months after lens wear,there were no statistically significant differences in the incidence of conjunctivitis,incidence of corneal staining,corneal endothe-lial cell density,or corneal thickness between the DISC and Ortho-K groups(all P>0.05).Conclusion DISC demon-strates superior myopia control efficacy in the short term(3 months)for younger children and those with low myopia,but its medium-term(6 months)and long-term(12 months)efficacy converges with that of Ortho-K.Furthermore,the long-term safety of DISC is not significantly different from that of Ortho-K.
8.Antagonistic effect of Lactobacillus reuteri on testicular reproductive toxicity of neonicotinoid insecticides in mice
Zhen-han XU ; Pei-gen CHEN ; Jin-tao GUO ; Lin-yan LÜ ; Hai-cheng CHEN ; Gui-hua LIU
National Journal of Andrology 2025;31(2):131-137
Objective:To explore the effect of Lactobacillus reuteri on testicular injury in mice exposed to neonicotinoid insec-ticides(NNI).Methods:Fifteen C57BL/6 male mice were randomly divided into control group(CTRI.group),exposure group(NNI group)and Lactobacillus intervention group(NNI-L group).The mice in CTRL group were given 0.02ml/g of 0.5%carboxym-ethyl cellulose sodium solution by gavage for 14 days.The mice in NNI group were given 0.02 ml/g of NNI mixture by gavage for 14 days.The mice in NNI-L group were given 0.02 ml/g of NNI mixture by gavage and 5 × 108cfu/ml of Lactobacillus reuteri powder so-lution for 14 days.Then,the histomorphology and function of testicle were evaluated by hematoxylin-eosin staining,immunofluores-cence staining and RNA sequencing.Results:Compared with CTRL group,the thickness of testicular seminiferous epithelium in the NNI group was significantly thinner.And the decline in the number of spermatogenic cells and sperm was observed.And the expression of spermatogonial stem cell marker UCHL1 was down-regulated which was significantly improved in NNI-L group compared with the NNI group.The abnormal expressions of hormone and sperm methylation related genes in testis of NNI group were detected by RNA sequen-cing,with significant down-regulation being found in NPFF and IGF2.While the expression of HSD3B8 was significantly up-regulated.The abnormal expression of these genes could be significantly improved after oral administration of Lactobacillus reuteri.Conclusion:Testicular spermatogenesis and endocrine function can be damaged by NNI exposure.And oral administration of Lactoba-cillus reuteri protects testis from the adverse effects of NNI toxicity.
9.Key technology and equipment development status of first-aid robotics
Zhen-bao WANG ; Zi-jian WANG ; Xin-xi XU ; Xin LIU ; Tao CHENG ; Pei-peng LIU ; Xiu-guo ZHAO ; Chen SU
Chinese Medical Equipment Journal 2025;46(3):96-114
The development status of the key technologies of first-aid robotics was introduced in autonomous system,embo-died intelligence,digital twins,large artificial intelligence model and autonomous unmanned medical treatment.The present situation in first-aid robotics equipment was reviewed for first-aid diagnosis,treatment,assistance and transportation.The development trends of the key technology and equipment of first-aid robotics were analyzed.It was pointed out the involve-ment of big model-based embodied intelligence technology and digital twins technology in first aid might provide new pers-pectives for the application and advancement of specialized first-aid robotics.[Chinese Medical Equipment Journal,2025,46(3):96-114]
10.Comparison of efficacy and safety of defocus incorporated soft contact lenses versus orthokeratology in myopic children with different baseline characteris-tics
Xinxin LU ; Cheng PEI ; Lu YE ; Jiaqi WANG ; Zhirong LIU ; Wenjun WANG
Recent Advances in Ophthalmology 2025;45(11):897-901
Objective To compare the efficacy and safety of defocus incorporated soft contact lenses(DISC)and orthokeratology(Ortho-K)for myopia control in children aged 8~15 years,and to further investigate the influence of dif-ferent baseline age and spherical equivalent(SE)on the treatment effect.Methods A retrospective cohort study was conducted,involving 197 myopic children(197 eyes)aged 8~15 years who were fitted with contact lenses at the Depart-ment of Ophthalmology,Xi'an People's Hospital(Xi'an Fourth Hospital)from May to September 2023.They were divid-ed into the DISC group(97 cases)and the Ortho-K group(100 cases).After 12 months of continuous follow-up,the chan-ges in axial length(AL)at 3,6,and 12 months after lens wear were compared between the two groups.Subgroup analysis was then performed:participants were divided into a younger subgroup(8~10 years)and an older subgroup(11~15 years)based on pre-wear age,and into a low myopia subgroup(-1.00~-3.00 D)and a moderate myopia subgroup(-3.25~-6.00 D)based on pre-wear SE.The AL changes at 3,6,and 12 months after wearing DISC or Ortho-K were com-pared between groups within these subgroups.Meanwhile,the incidence of conjunctivitis,incidence of corneal staining,corneal endothelial cell density,and corneal thickness were compared between the two groups at 12 months after lens wear.Results Inter-group comparisons showed:The change in AL in the DISC group at 3 months after lens wear was significantly lower than that in the Ortho-K group,and the difference was statistically significant(P<0.05);at 6 and 12 months after lens wear,the differences in AL change between the two groups were not statistically significant(both P>0.05).Subgroup analysis by age and SE showed:In the younger subgroup and the low myopia subgroup,the AL change in the DISC group at 3 months after lens wear was significantly lower than that in the Ortho-K group,and the differences were statistically significant(both P<0.05),but these differences disappeared at 6 and 12 months after lens wear(all P>0.05);in the older subgroup and the moderate myopia subgroup,the differences in AL change between the two groups at 3,6,and 12 months after lens wear were not statistically significant(all P>0.05).At 12 months after lens wear,there were no statistically significant differences in the incidence of conjunctivitis,incidence of corneal staining,corneal endothe-lial cell density,or corneal thickness between the DISC and Ortho-K groups(all P>0.05).Conclusion DISC demon-strates superior myopia control efficacy in the short term(3 months)for younger children and those with low myopia,but its medium-term(6 months)and long-term(12 months)efficacy converges with that of Ortho-K.Furthermore,the long-term safety of DISC is not significantly different from that of Ortho-K.

Result Analysis
Print
Save
E-mail