1.Advances in the role of protein post-translational modifications in circadian rhythm regulation.
Zi-Di ZHAO ; Qi-Miao HU ; Zi-Yi YANG ; Peng-Cheng SUN ; Bo-Wen JING ; Rong-Xi MAN ; Yuan XU ; Ru-Yu YAN ; Si-Yao QU ; Jian-Fei PEI
Acta Physiologica Sinica 2025;77(4):605-626
The circadian clock plays a critical role in regulating various physiological processes, including gene expression, metabolic regulation, immune response, and the sleep-wake cycle in living organisms. Post-translational modifications (PTMs) are crucial regulatory mechanisms to maintain the precise oscillation of the circadian clock. By modulating the stability, activity, cell localization and protein-protein interactions of core clock proteins, PTMs enable these proteins to respond dynamically to environmental and intracellular changes, thereby sustaining the periodic oscillations of the circadian clock. Different types of PTMs exert their effects through distincting molecular mechanisms, collectively ensuring the proper function of the circadian system. This review systematically summarized several major types of PTMs, including phosphorylation, acetylation, ubiquitination, SUMOylation and oxidative modification, and overviewed their roles in regulating the core clock proteins and the associated pathways, with the goals of providing a theoretical foundation for the deeper understanding of clock mechanisms and the treatment of diseases associated with circadian disruption.
Protein Processing, Post-Translational/physiology*
;
Circadian Rhythm/physiology*
;
Humans
;
Animals
;
CLOCK Proteins/physiology*
;
Circadian Clocks/physiology*
;
Phosphorylation
;
Acetylation
;
Ubiquitination
;
Sumoylation
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Key technology and equipment development status of first-aid robotics
Zhen-bao WANG ; Zi-jian WANG ; Xin-xi XU ; Xin LIU ; Tao CHENG ; Pei-peng LIU ; Xiu-guo ZHAO ; Chen SU
Chinese Medical Equipment Journal 2025;46(3):96-114
The development status of the key technologies of first-aid robotics was introduced in autonomous system,embo-died intelligence,digital twins,large artificial intelligence model and autonomous unmanned medical treatment.The present situation in first-aid robotics equipment was reviewed for first-aid diagnosis,treatment,assistance and transportation.The development trends of the key technology and equipment of first-aid robotics were analyzed.It was pointed out the involve-ment of big model-based embodied intelligence technology and digital twins technology in first aid might provide new pers-pectives for the application and advancement of specialized first-aid robotics.[Chinese Medical Equipment Journal,2025,46(3):96-114]
5.Research progress on the application of functional near-infrared spectroscopy in children and adolescents with mental disorders
Pei TANG ; Lewei LIU ; Lili ZHAO ; Xi ZHANG ; Yun ZHANG ; Lei XIA ; Huanzhong LIU
Chinese Journal of Psychiatry 2025;58(10):793-799
Functional near-infrared spectroscopy (fNIRS) is an emerging neuroimaging technique, strengthened by the advantages of non-invasiveness, operational convenience, real-time monitoring, and well compatibility. In recent years, its application has shown great promise in the diagnosis and treatment of mental disorders among children and adolescents. This article provides an overview of the fundamental principles of fNIRS. It focuses on its effectiveness in the diagnosis, symptom assessments, and treatment monitoring of mental disorders in children and adolescents.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Monte Carlo simulation study of the effect of filter on radiotherapy dosimetry in superficial X-ray therapy apparatus
Li TAO ; Hui ZHANG ; Yikai WU ; Junyi LIU ; Miao QI ; Ning GAO ; Yankui CHANG ; Xi PEI ; Zhi CHEN ; Xie XU
Chinese Journal of Radiological Medicine and Protection 2025;45(3):194-201
Objective:To explore the dosimetry optimization strategy based on filter thickness and shape selection for the bulb superficial X-ray radiotherapy unit.Methods:Monte Carlo code TOPAS was used to model tubular equipment, and the dose distribution from six X-ray energies (50-150 kV) and five conventional aluminum filters (0.5-3.0 mm) with different thickness were simulated in the water model. The percentage depth dose (PDD) curve along the central axis, the center-axis profile dose at different depths, and the lateral dose distribution were analyzed. The dose distribution of three different designs of aluminum filters (conventional cylindrical, conical and oblique cylindrical filters) was compared to evaluate the effect of dosimetric optimization of different filter shapes.Results:Under the same energy, increasing the thickness of the filter can optimize the superficial skin dose, and the optimization effect of depth dose uniformity can be increased by 26% at a depth of 5.5 mm at 70 kV energy. The raised, flat and inclined dose distribution modes can be achieved by using conventional cylindrical, conical and inclined aluminum filters.Conclusions:By selecting the appropriate X-ray energy and filter thickness, an ideal dose distribution matching the tumor depth can be achieved. The application of personalized filters is also of great significance for diverse target areas.
9.Treatment plan optimization for intensity-modulated brachytherapy based on the conjugate gradient algorithm
Miao QI ; Junyi LIU ; Shijun LI ; Yankui CHANG ; Jieping ZHOU ; Bing YAN ; Yong CHENG ; Aidong WU ; Xi PEI ; Xie XU
Chinese Journal of Radiological Medicine and Protection 2025;45(1):56-62
Objective:To investigate the application of the conjugate gradient (CG) algorithm to treatment plan optimization for intensity-modulated brachytherapy (IMBT).Methods:The general Monte Carlo software TOPAS was utilized to simulate the 192Ir source of IMBT, and the unit dose contribution matrix was calculated. An objective function was established using the weighted least squares method and was solved using the CG algorithm to achieve optimized IMBT treatment plans. The optimization was validated using five clinical cervical cancer cases under modulation width 60°. The dose distributions of IMBT treatment plans under 45°, 60°, 90°, 120°, and 180° modulation widths were compared using the Wilcoxon test to determine the optimal IMBT treatment plan for cervical cancer treatment. Results:The CG algorithm successfully optimized IMBT treatment plans under modulation width 60° for five cases within 22.2 s on average. On the premise of sufficient target dose coverage, the average D2 cm 3 values of the bladder and rectum in IMBT treatment plans were 3.66 and 1.97 Gy, respectively, representing reductions of 0.54 and 0.69 Gy compared to traditional brachytherapy plans. For the five modulation widths, the D90% values of all IMBT treatment plans reached 6 Gy, without statistically significant differences ( P > 0.05). The average D2 cm 3 values of the bladder in IMBT treatment plans were significantly lower than those in the traditional brachytherapy plans( P<0.05), with modulation width 60° associated with the greatest reduction of 0.61 Gy. In contrast, the average D2 cm 3 values of the rectum under 45°, 60°, and 90° modulation widths decreased by 0.63, 0.54, and 0.45 Gy, respectively, compared to traditional plans, with statistically significant differences( P<0.05). Conclusions:The CG method enables rapid achievement of optimized IMBT treatment plans that meet clinical requirements, and modulation width 60° contributes to valid dosimetric optimization. This study can serve as a guide for the clinical implementation of IMBT.
10.Application of the ArcherQA 3D dosimetric verification system in dosimetric verification of VMAT plans
Jieping ZHOU ; Ning GAO ; Zhongyu QI ; Qiang REN ; Xi PEI ; Xie XU ; Aidong WU
Chinese Journal of Radiological Medicine and Protection 2025;45(6):551-557
Objective:To rapidly and accurately detect volumetric modulated arc therapy (VMAT) plans with potentially inaccurate radiation doses.Methods:The measurement-based dosimetric verification result of 196 VMAT plans obtained using ArcCHECK phantoms were retrospectively collected. Independent dosimetric calculation and verification were conducted for these plans using the ArcherQA system based on a fast Monte Carlo algorithm. The gamma passing rates of dosimetric verification using ArcCHECK phantom and the ArcherQA system were compared, followed by their correlation analysis and linear regression fitting. The ArcherQA system′s gamma passing rate threshold used to detect positive dosimetric verification result obtained using ArcCHECK phantoms, as well as the specificity of the detection, were calculated. Based on this gamma passing rate threshold, another 50 VMAT plans were selected as a test set to assess the ArcherQA system′s ability to detect positive measurement-based dosimetric verification result.Results:The average gamma passing rates for the dosimetric verification of the VMAT plans using the ArcherQA system and ArcCHECK phantoms were 97.28% and 96.57% (3%/3 mm, TH=10%), respectively. Both rates had a correlation coefficient of 0.71 ( P < 0.01) and a linear fitting coefficient of 0.54 ( R2=0.51). When the gamma passing rate for dosimetric verification using ArcCHECK phantoms was set at 90% (3%/2 mm, TH=10%), the gamma passing rate threshold for dosimetric verification using the ArcherQA system should be adjusted to 94.8% to detect all VMAT plans with positive dosimetric verification result obtained using ArcCHECK phantoms, with a specificity of 67.8%. Using this threshold, the ArcherQA system detected all VMAT plans in the test set for which ArcCHECK phantom-based measurement yielded positive dosimetric verification result. Conclusions:By determining an appropriate gamma passing rate threshold, the ArcherQA system can rapidly and accurately detect VMAT plans with potentially inaccurate doses, thus ensuring treatment accuracy and improving work efficiency.

Result Analysis
Print
Save
E-mail