1.Traditional Chinese Medicine Alleviates Dry Eye Disease by Regulating Tear Film Homeostasis: A Review
Sainan TIAN ; Bin'an WANG ; Yao CHEN ; Guicheng LIU ; Li TANG ; Pei LIU ; Genyan QIN ; Jun PENG ; Qinghua PENG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(7):172-181
Dry eye (DE) is a prevalent multifactorial disease of the ocular surface, clinically characterized by tear film homeostasis imbalance accompanied by related ocular surface symptoms. Specifically, the tear film is a thin liquid layer of tears covering the cornea and conjunctiva through blinking, while tear film homeostasis serves as the foundation for maintaining normal ocular surface structure and function. Insufficient tear secretion and excessive tear film evaporation lead to tear hyperosmolarity and the production of inflammatory mediators, disrupting tear film homeostasis and subsequently forming DE. Additionally, cascade reactions are triggered, resulting in a "vicious cycle of DE" that exacerbates the disease severity and prolongs its duration. Therefore, for DE treatment, it is crucial to restore tear film homeostasis and terminate this vicious cycle. Traditional Chinese medicine (TCM), which differentiates and treats DE based on systemic conditions, often achieves favorable therapeutic outcomes, offering additional treatment options for DE. Studies have demonstrated that TCM can alleviate DE by regulating tear film homeostasis and terminating the vicious cycle. This review systematically summarizes recent basic experimental research in China and abroad on TCM in alleviating DE by regulating tear film homeostasis, aiming to provide a theoretical basis for clinical treatment and an insight for research design.
2.Establishment and Evaluation of Mouse Model of Dry Eye with Lung Yin Deficiency Syndrome
Liyuan CAO ; Pei LIU ; Yuhui QIN ; Qinghua PENG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(7):182-190
ObjectiveTo establish a model of dry eye with lung Yin deficiency syndrome in mice. MethodsA total of 40 SPF C57BL/6J mice were assigned via the random number table method into 5 groups (n=8): Normal control, model control, and high-, medium-, and low-dose (11.7, 5.85, and 2.925 g·kg-1, respectively) Yangyin Qingfeitang. Mice in the normal control group were fed normally without any intervention. Mice in Yangyin Qingfeitang group and model control group were treated with 0.2% benzalkonium chloride eye drops (5 μL) twice a day and fed in a controlled drying system in a dry environment for 28 days. At the same time, the mice were administrated with thyroxine tablet solution by gavage and placed in a glass fumigation tank (SO2 concentration: 0.5 g·m-3) for 14 days. After 4 weeks, mice in Yangyin Qingfeitang groups were treated with Yangyin Qingfeitang by gavage and those in the normal control group and model control group were administrated with deionized water at 0.01 mL·g-1. The body mass, anal temperature, four examination information (claw and nail appearance), basic tear secretion test, tear film rupture time, corneal fluorescein staining, and lacrimal gland HE staining were compared among groups. Compound Yangyin Qingfeitang granules were used to measure the syndrome to verify the success of modeling. ResultsAfter 28 days of continuous modeling, compared with the normal control group, the model group exhibited listless and emaciated status, coughing, drowsiness, dry and dull hair, dry and hard stool, reduced food intake and water intake, red lip circumference, red tongue with reduced fluid, dry nose and teeth, red claws and nails, body mass gain, decreased anal mild tear secretion (P<0.05), and shortened tear film rupture time (P<0.05). After 28 days of modeling, the mice showed large corneal fluorescein staining range, severe corneal injury, and increased content of interleukin (IL)-18, IL-β, and tumor necrosis factor (TNF)-α in lacrimal gland, compared with those in the normal control group (P<0.05). After the treatment with Yangyin Qingfeitang, the mice had good drinking and eating conditions, with lighter redness of the tongue, moist nose, moist and shiny teeth, and the claw and nail color close to that in the normal group. Compared with the model control group, Yangyin Qingfeitang groups showed increases in body mass and anal temperature (P<0.05), tear secretion (P<0.05), and tear film rupture time (P<0.05), narrowed range of corneal fluorescein staining, and declined levels of IL-18, IL-β, and TNF-α in lacrimal glands (P<0.01). The high-dose group had the best effect, with the indicators close to the levels in the normal control group. ConclusionThe animal model of dry eye with lung Yin deficiency syndrome can be established by culture in a controlled drying system, treatment with benzalkonium chloride eye drops for 28 days, and administration of thyroxine tablet solution combined with SO2 fumigation for 14 days.
3.Mechanism of MEK/Ras/Raf/ERK Signaling Pathway Modulated by Mimenghua Prescription on Inflammatory Response in Dry Eye Animal Model
Shi TAN ; Pei LIU ; Yuan ZHONG ; Sainan TIAN ; Pengfei JIANG ; Genyan QIN ; Qinghua PENG ; Jun PENG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(7):211-221
ObjectiveThis paper aims to investigate the effects and mechanism of Mimenghua prescription in modulating the mitogen-activated protein kinase kinase (MEK)/rat sarcoma viral oncogene homolog (Ras)/rapidly accelerated fibrosarcoma kinase (Raf)/extracellular signal-regulated kinase (ERK) signaling pathway to inhibit inflammatory responses in a dry eye animal model. MethodsA total of 60 C57BL/6J mice (eight weeks old, half male and half female) were used in the experiment. Ten mice were randomly selected as the blank control group, while the remaining 50 were exposed to a controlled dry system and received instillation of 0.2% benzalkonium chloride (BAC) into the eyes for four weeks to establish a dry eye mouse model. After successful modeling, the mice were randomly divided into five groups: Model group, sodium hyaluronate group, and Mimenghua prescription groups with low dose (4.83 g·kg-1), medium dose (9.67 g·kg-1), and high dose (19.34 g·kg-1). The mice in the model group received an equal volume of normal saline via gavage for four weeks. The mice in the sodium hyaluronate group received instillation of sodium hyaluronate eye drops twice daily for 14 consecutive days. The tear secretion volume, tear film break-up time (TBUT), and corneal fluorescein staining were evaluated once every two weeks. After four weeks of administration, mice were euthanized, and their lacrimal gland tissues and corneas were harvested. Hematoxylin-eosin (HE) staining was used to assess histopathological morphology. Western blot was performed to detect the protein expression levels of MEK, Ras, Raf, and ERK. Enzyme-linked immunosorbent assay (ELISA) was used to measure the contents and expressions of MEK, Ras, Raf, ERK, and interleukin (IL)-1β in lacrimal gland and corneal tissues of the mice in each group. Quantitative real-time polymerase chain reaction (Real-time PCR) was employed to determine mRNA expression levels of MEK, Ras, Raf, and ERK. ResultsThe Mimenghua prescription groups and the sodium hyaluronate group exhibited significantly increased tear secretion volume (P<0.05) and prolonged TBUT (P<0.05) after treatment. Ocular surface damage of mice was visibly recovered. Western blot results indicated that protein expression levels of MEK, Ras, Raf, and ERK in the lacrimal gland and corneal tissues were significantly downregulated in the sodium hyaluronate group and Mimenghua prescription group with high dose (P<0.05). ELISA results showed that IL-1β levels were highest in the model group but significantly reduced in the sodium hyaluronate group and Mimenghua prescription groups (P<0.05). Both ELISA and Real-time PCR results demonstrated that the expression levels of MEK, Ras, Raf, and ERK in the lacrimal glands and corneal tissues were significantly elevated in the model group (P<0.05), but markedly downregulated in the sodium hyaluronate group and Mimenghua prescription groups (P<0.05), suggesting that Mimenghua prescription can decrease the expressions of MEK, Ras, Raf, and ERK in the lacrimal glands and corneal tissues. ConclusionMimenghua prescription can reduce inflammatory responses, increase tear secretion, prolong TBUT, and promote corneal recovery by inhibiting the MEK, Ras, Raf, and ERK signaling pathways in lacrimal gland and corneal tissues.
4.Construction and Application of"On-Off-On"Fluorescence Sensor for Chlorpromazine Hydrochloride Based on Near Infrared Carbon Quantum Dots
Yu LIN ; Feng TAN ; Yu-Hua SHEN ; Li-Qin ZHU ; Pei-Yao YAN ; Jin-Tao PAN ; Kai-Shun LIU
Chinese Journal of Analytical Chemistry 2025;53(6):934-943
In this work,near infrared carbon quantum dots(NIR-CDs)were synthesized by hydrothermal method using biomass material Clausena lansium leaves.The synthesized NIR-CDs emitted maximum fluorescence signal at 677 nm,which was independent of excitation wavelength.The characterization results showed that there were abundant groups on the surface of NIR-CDs.Pd2+could form non-fluorescent compounds with the surface groups of NIR-CDs,resulting in fluorescence quenching(Fluorescence signal was denoted as F0).Because chlorpromazine hydrochloride(CPZ)parent nucleus contained unoxidized S atom,CPZ could form stable colored complex with Pd2+under acidic conditions.In the presence of CPZ,Pd2+dissociated from the surface of NIR-CDs and bonded with CPZ,so that the fluorescence signal could be restored(Fluorescence signal was denoted as F).An"on-off-on"fluorescence sensor was thus constructed.The fluorescence signal recovery value of NIR-CDs(△F=F-F0)showed a good linear relationship with the concentration of CPZ in the range of 5.68-28.43 μg/mL,and the detection limit(3σ)was 0.078 μg/mL.The sensor was applied to determination of CPZ in pharmaceutical preparations,and the recoveries were 94%-106%.The developed fluorescence sensor was expected to be used in quality control of actual pharmaceutical preparations.
5.Visualization and Analysis of Sweat Pore Features in Latent Fingerprints Using Core-Shell Structured Composite Nanofibrous Membrane
Shi-Yue MA ; Ya-Li PEI ; Hong-Yu CHEN ; Xin DU ; Yan-Feng ZHANG ; Rong-Liang MA ; Mei-Qin ZHANG
Chinese Journal of Analytical Chemistry 2025;53(8):1269-1278
Introducing fingerprint level 3 features(especially sweat pores)in fingerprint recognition can significantly improve the value of fingerprints.However,conventional fingerprint visualization methods suffer from issues such as poor stability and reproducibility,insufficient resolution,and feature masking in detecting level 3 features.Electrospun membrane has unique advantages in latent fingerprint(LFP)detection due to its excellent adsorption performance and high specific surface area,and thus its application potential in LFP visualization urgently need to be explored.A novel pore visualization method based on core-shell structured PAN-Flu/PVP composite nanofibrous membrane was proposed in this work.Specifically,the PAN-Flu/PVP composite nanofibrous membrane was prepared via coaxial electrospinning technology,with polyacrylonitrile(PAN)loaded with fluorescein(Flu)as the core and polyvinylpyrrolidone(PVP)as the shell.The experimental results showed that the prepared PAN Flu/PVP composite nanofibrous membrane had a porous structure and excellent adsorption performance.Based on the water solubility of the outer shell PVP and the water induced fluorescence enhancement effect of the core Flu,high-resolution visualization of sweat pores could be achieved within 2 s.The optimization experiment showed that the best quality of sweat latent fingerprints was obtained when the Flu content was 4 mg/mL,the spinning time was 1 h,and the sweating time was 2 min.Through repeated fingerprinting and live fingerprint comparison experiment,the strong stability and high reproducibility of the as-produced membrane in displaying fingerprint sweat pores were finally verified.In summary,the development method could quickly,stably and accurately extract the spatial distribution and activity level of fingerprint sweat pores,which was of great significance for improving the utilization and value of fingerprints.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail