1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Ultrasound-guided quadratus lumborum block at lateral supra-arcuate ligament for analgesia after open hepatectomy
Lei ZHANG ; Ya-Jun DING ; Pei-Pei KANG
Journal of Regional Anatomy and Operative Surgery 2024;33(11):955-958
Objective To explore the analgesic effect of ultrasound-guided quadratus lumborum block at lateral supra-arcuate ligament after open hepatectomy.Methods A total of 106 patients with open hepatectomy in our hospital from April 2022 to May 2023 were selected prospectively and randomly divided into the control group(anesthetized by ultrasound-guided subcostal transverse abdominis plane block)and the observation group(anesthetized by ultrasound-guided quadratus lumborum block at lateral supra-arcuate ligament),with 53 cases in each group.The postoperative recovery index,immune function,and numerical rating scale(NRS)score and Ramsay sedation score in each time point of patients in the two groups were compared,and the incidence of adverse reactions during hospitalization was counted.Results The time of getting out of bed and anal discharge time of patients in the observation group were earlier than those in the control group(P<0.05),the dosage of sufentanil in 48 hours and numbers of analgesic pump compressions were less than those in the control group(P<0.05),Ramsay sedation scores 6 hours and 12 hours after surgery were higher than those in the control group(P<0.05),NRS scores at resting and cough 6 hours,12 hours,24 hours after surgery were lower than those in the control groups(P<0.05),the contents of CD4+,NK and CD4+/CD8+24 hours after surgery were higher than those in the control group(P<0.05).There was no statistically significant difference in the incidence of postoperative adverse reactions between the two groups(P>0.05).Conclusion Ultrasound-guided quadratus lumborum block at lateral supra-arcuate ligament in patients with open hepatectomy can achieve ideal analgesic and sedative effects,and promote postoperative recovery.
7.Muscle-brain crosstalk mechanisms in the cognitive-motor interference effects of freezing of gait in Parkinson disease
Pei LI ; Peizhu ZHANG ; Gongqiang WANG ; Xinfeng MA ; Guang'an TONG ; Kang LIN ; Ping JIN
Chinese Journal of Behavioral Medicine and Brain Science 2024;33(9):813-818
Freezing of gait is a common gait disorder in Parkinson disease (PD), which is highly disabling, situational and therapeutically challenging. At present, there is no clear and effective intervention method. In recent ten years, exercise training based on cognitive-motor dual tasks has been more and more used in the intervention treatment of freezing of gait of PD patients, and achieved certain clinical results. The muscle-brain crosstalk effect of exercise training promoting muscle secretory factors is crucial for freezing of gait rehabilitation of PD. There are differences in the effects of cognitive-motor dual tasks of different types and loads on gait, but the specific training types and loads and mechanism of action still need to be further elucidated. This paper focuses on the research progress of muscle-brain crosstalk mechanism in cognitive-motor interference effect of freezing of gait in PD patients, aiming to providing a new theoretical perspective for clinical cognitive-motor training intervention of freezing of gait in PD patients.
8.Research on evaluation and screening indicator for emergency ventilators
Qin-Qi YAO ; Ming-Kang TANG ; Long-Ying YE ; Pei-Pei ZHANG ; Ke-Sheng WANG ; Dan LING ; Qian-Hong HE ; Zhu CHEN
Chinese Medical Equipment Journal 2024;45(7):8-16
Objective To propose an evaluation and screening indicator for the reliability of emergency ventilators.Methods Firstly,a regression model was used to clean the data and remove noise to ensure the accuracy of regression analysis.Then,four groups of highly correlated data combinations,including inspiratory tidal volume-minute expiratory volume,peak airway pressure-minute expiratory volume,peak airway pressure-inspiratory tidal volume and positive end-expiratory pressure(PEEP)-mean airway pressure,were determined with the methods of curve fitting and transfer function,and the difference between the theoretical output and the actual output of the data combinations was regarded as an indicator to judge whether the ventilator functioned well or not;finally,the indicator proposed was applied to single and multiple ventilators,and the feasibility of the indicator was determined by the proportion of the ventilators functioning well.Results The evaluation results with a single ventilator showed the four groups of data combinations had the actual output fitted well with the theoretical output,and all the differences between the theoretical output and the actual output were lower than the threshold;the results with multiple ventilators indicated there were 71.49%ventilators functioning well,which was very close to the actual result that 72%ventilators behaved well.Conclusion The evaluation and screening indicator for emergency ventilators has high feasibility,and theoretical support is provided for reliability assessment and selection of series of emergency treatment equipment.[Chinese Medical Equipment Journal,2024,45(7):8-16]
9.Review of gallium-based liquid metals for medical applications
Pei-Kai ZHAO ; Yu-Long WANG ; Yong-Kang ZHAN ; Jia-Xing QI ; Xu-Yi CHEN
Chinese Medical Equipment Journal 2024;45(11):97-102
The gallium-based liquid metals were introduced in terms of the advantages when applied in medical field,application status in medical imaging,drug delivery,antibiosis and tumor therapy and cutting-edge application in flexible e-skin,wearable sensor and flexible medical device.The deficiencies of the gallium-based liquid metals in durability,potential toxicity,high cost of preparation and difficulty of process control were analyzed when applied in medical fields.The future development directions of the gallium-based liquid metals were pointed out.[Chinese Medical Equipment Journal,2024,45(11):97-102]
10.Ameliorating effect of calycosin regulating SIRT3/SOD2 signaling pathway on airway epithelial cell damage in mice
Jia NIE ; Yongying GUO ; Xiangyan YU ; Yuzhen PEI ; Yun LIU ; Zenglu KANG ; Yinghao SU
Tianjin Medical Journal 2024;52(11):1171-1176
Objective To investigate effects of calycosin(CA)on cigarette smoke(CS)induced airway epithelial cell damage in mice and the sirtuin 3/superoxide dismutase 2(SIRT3/SOD2)signaling pathway in mice.Methods A total of 90 mice were randomly separated into the control group,the cigarette smoke(CS)group,the CA low-dose treatment group(CA-L group),the CA high-dose treatment group(CA-H group)and the CA high-dose treatment plus SIRT3 inhibitor 3-TYP group(CA-H+3-TYP group),with 18 mice in each group.Tidal volume(TV)and peak expiratory flow rate(PEF)of lung function were detected by whole body plethysmography system.Serum levels of inflammatory factors[interleukin(IL)-6,tumor necrosis factor(TNF)-α]and oxidative stress indicators[reactive oxygen species(ROS),SOD]were detected by enzyme-linked immunosorbent assay(ELISA).The injury of airway epithelial cells in lung tissue was observed by HE staining.The expression levels of barrier related proteins(OCLN and ZO-1)in airway epithelial cells were detected by immunohistochemistry.Immunoblotting was applied to detect the expression of SIRT3/SOD2 signaling pathway related proteins.Results Compared with the control group,levels of TV,PEF,MAN and SOD and the expression levels of OCLN,ZO-1,SIRT3 and SOD2 were decreased in the CS group,while the levels of MLI,IL-6,TNF-α and ROS were increased(P<0.05).Compared with the control group,the lung tissue structure was significantly damaged,the alveolar enlargement was obvious,the surrounding alveolar was accompanied by inflammatory cell infiltration,and the airway epithelial cells were obviously shed in the CS group.Different doses of CA alleviated lung tissue destruction,improved alveolar structure,reduced inflammatory cell infiltration,reduced airway epithelial cell shedding,increased levels of TV,PEF,MAN,SOD and OCLN,ZO-1,SIRT3 and SOD2,and decreased levels of MLI,IL-6,TNF-α and ROS.The effect of high dose CA was more significant than that of low dose CA(P<0.05).SIRT3/SOD2 signaling pathway inhibitor 3-TYP partially reversed the ameliorative effect of CA on CS induced airway epithelial cell injury in mice.Conclusion CA can ameliorate CS induced airway epithelial cell damage in mice,and its mechanism is related to the activation of the SIRT3/SOD2 signaling pathway.

Result Analysis
Print
Save
E-mail