1.Emotional processing characteristics and electroencephalography power values in patients with Parkinson disease: A differential analysis
Journal of Apoplexy and Nervous Diseases 2026;43(3):259-264
Objective To investigate the differences in emotional processing characteristics and electroencephalography (EEG) power values in patients with Parkinson disease (PD). Methods A total of 24 PD patients were enrolled as subjects, and 30 healthy individuals were enrolled as control group. With the use of the EPIE experimental paradigm, SAM questionnaire was used to determine the scores of emotional valence and arousal, and EEG was used for real-time monitoring of cortical EEG signals. The two groups were compared in terms of the differences in valence/arousal and EEG power values under different emotions and their correlation. Results The PD group had significantly higher BAI and BDI scores than the control group[BAI(16.92±3.83)vs(11.62±3.65),t=4.521,P<0.05;BDI(22.69±2.30)vs(14.17±4.06),t=7.981,P<0.05]. In the negative mood, there were significant differences in valence/arousal between the two groups (t=4.505,-7.705,bothP<0.05). There were significant differences between the two groups in power values at Fp1,Fp2,F7,F3,F4,T3,T4, and T5(t=-4.12,-12.43,5.76,-2.90,-4.72,-5.34,-5.81,-2.65,all P<0.05). In the negative mood, for the control group, valence score was correlated with Fp1 (r=-0.837, P<0.01), Fp2 (r=-0.920, P<0.01),F4(r=-0.604,P=0.008),P3(r=-0.658,P=0.003),and P4(r=-0.546,P=0.019), and arousal score was correlated with Fp1(r=0.887, P<0.01), Fp2 (r=0.958, P=0.003),F4(r=0.683,P=0.003),P3 (r=0.721, P=0.003),and P4 (r=0.610,P=0.007); for the PD group, valence score was correlated with Fp2(r=-0.490,P=0.015) and F7(r=-0.564,P=0.004), and arousal score was correlated with Fp2 (r=0.440, P=0.031) and F7(r=0.853,P<0.01). Conclusion Patients with PD have negative emotional processing abnormalities associated with right PFC and left lateral FL.
Electroencephalography
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Role of lifestyle factors on the development and long-term prognosis of pneumonia and cardiovascular disease in the Chinese population.
Yizhen HU ; Qiufen SUN ; Yuting HAN ; Canqing YU ; Yu GUO ; Dianjianyi SUN ; Yuanjie PANG ; Pei PEI ; Ling YANG ; Yiping CHEN ; Huaidong DU ; Mengwei WANG ; Rebecca STEVENS ; Junshi CHEN ; Zhengming CHEN ; Liming LI ; Jun LV
Chinese Medical Journal 2025;138(12):1456-1464
BACKGROUND:
Whether adherence to a healthy lifestyle is associated with a lower risk of developing pneumonia and a better long-term prognosis remains unclear. This study aimed to investigate associations of individual and combined lifestyle factors (LFs) with the incidence risk and long-term prognosis of pneumonia hospitalization.
METHODS:
Using data from the China Kadoorie Biobank study, we used the multistate models to investigate the role of five high-risk LFs, including smoking, excessive alcohol drinking, unhealthy dietary habits, physical inactivity, and unhealthy body shape, alone or in combination in the transitions from a generally healthy state at baseline to pneumonia hospitalization or cardiovascular disease (CVD, regarded as a reference outcome), and subsequently to mortality.
RESULTS:
Most of the five high-risk LFs were associated with increased risks of transitions from baseline to pneumonia and from pneumonia to death, but with different risk estimates. The greater the number of high-risk LFs, the higher the risk of developing pneumonia and long-term mortality risk after pneumonia, with the strength of associations comparable to that of LFs and CVD. Compared to participants with 0-1 high-risk LF, the adjusted hazard ratios (HRs) and 95% confidence intervals (CIs) for transitions from baseline to pneumonia and from pneumonia to death in those with five high-risk LFs were 1.43 (1.28-1.60) and 1.98 (1.61-2.42), respectively. Correspondingly, the respective HRs (95% CIs) for transitions from baseline to CVD and from CVD to death were 2.00 (1.89-2.11) and 1.44 (1.30-1.59), respectively. The risk estimates changed slightly when further adjusting for the presence of major chronic diseases.
CONCLUSION
In this Chinese population, unhealthy LFs were associated with an increased incidence and long-term mortality risk of pneumonia.
Adult
;
Aged
;
Female
;
Humans
;
Male
;
Middle Aged
;
Cardiovascular Diseases/etiology*
;
China/epidemiology*
;
Life Style
;
Pneumonia/etiology*
;
Prognosis
;
Risk Factors
;
Smoking
5.Effects of honey-processed Astragalus on energy metabolism and polarization of RAW264.7 cells
Hong-chang LI ; Ke PEI ; Wang-yang XIE ; Xiang-long MENG ; Zi-han YU ; Wen-ling LI ; Hao CAI
Acta Pharmaceutica Sinica 2025;60(2):459-470
In this study, RAW264.7 cells were employed to investigate the effects of honey-processed
6.MR ultrashort echo time and T1W sequences for detecting bone erosions of gouty arthritis
Tong YU ; Xiaoli LI ; Pei NIE ; Ying CHEN ; Lin HAN ; Meihan CHEN ; Fengjiao LI ; Xin HUANG ; Changgui LI ; Wenjian XU
Chinese Journal of Medical Imaging Technology 2025;41(3):452-456
Objective To compare the value of ultrashort echo time(UTE)and T1W sequences for detecting bone erosions of gouty arthritis.Methods Forty-four gouty patients were prospectively enrolled,including 32 cases with affected feet and 12 cases with affected knee.MR UTE and T1W sequence scanning of the affected area were performed,and subjectively scoring of imaging quality of 2 kinds of MRI were evaluated,respectively.Then total number and total score of bone erosions of each case were calculated according to all affected bones.Taken DECT as reference standard,the efficacy of UTE and T1WI for detecting bone erosions was assessed through comparing with DECT using Kappa coefficient.Results The imaging quality score of T1WI was lower than that of DECT(all P<0.05),while no significant difference was found between UTE and DECT(all P>0.05).There was high agreement between UTE and DECT for detecting bone erosions(κ=0.949),while the agreement between T1WI and DECT ranged from good to high(κ=0.718 to 0.805).The total number and total score of bone erosions based on T1WI were significantly lower than those based on DECT(all P<0.05),while no significant difference was found between UTE and DECT(all P>0.05).Conclusion UTE was better than T1WI for detecting bone erosions of gouty arthritis.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Preliminary exploration of the mode and timing of delivery for complex fetal congenital heart disease
Junshu XIE ; Manman HAN ; Xiuju YIN ; Tiantian HAN ; Qiuyan PEI ; Lin ZHANG ; Huili ZHANG ; Shoujun LI ; Xiaohong ZHANG
Chinese Journal of Obstetrics and Gynecology 2025;60(10):763-771
Objective:To investigate the mode and timing of delivery in pregnant women with complex fetal congenital heart disease (CHD) detected by prenatal ultrasound.Methods:The clinical data of 123 fetuses with complex CHD detected by prenatal ultrasound in Peking University People′s Hospital from January 2016 to December 2023 were retrospectively analyzed. Pregnant women with indications for prenatal diagnosis underwent G-banding karyotype analysis, single nucleotide polymorphism array (SNP arrry) or whole exome sequencing after informed consent. Integrated managements were provided for pregnant women with complex CHD during pregnancy and perinatal period, and to determine the mode and timing of delivery. Infants with complex CHD received timely treatment or referral after birth.Results:The gestational age at ultrasound diagnosis of the 123 fetuses with complex CHD was (23.7±3.4) weeks. There were 11 cases (8.9%) of total anomalous pulmonary venous connection (TAPVC), 14 cases (11.4%) of anomalous pulmonary valve (PVA), 7 cases (5.7%) of right ventricle double outlet (RVDO), 13 cases (10.6%) of anomalous aortic arch, 69 cases (56.1%) of transposition of the great arteries (TGA), 9 cases (7.3%) of other types. All cases were treated with fetal preservation after prenatal consultation. Among the 72 cases undergoing prenatal diagnosis, 9 cases (12.5%) had chromosomal variations. Fifty-five cases (44.7%, 55/123) underwent trial of labor, of which 46 cases (37.4%, 46/123) had successful vaginal delivery, including 6 cases of forceps delivery, and other 9 cases of failed trial of labor transferred to cesarean section. A total of 77 cases of pregnant women underwent cesarean section. Except for the 21 cases of pregnant women who asked for cesarean section, the cesarean section rate of pregnant women with complex CHD was 45.5% (56/123), which was not significantly different from the average cesarean section rate of the same period in our hospital (40.2%; χ2=7.34, P=0.270). The gestational age at delivery of the 123 fetuses with complex CHD was (37.9±1.4) weeks, the birth weight of the neonates was (3 099±480) g, and the umbilical artery blood pH value was 7.31±0.05. The oxygen saturation of 86 cases before and after alprostadil infusion were (72.8±6.0)% and (80.5±5.0)%, respectively, and the difference was statistically significant ( t=4.38, P<0.001). One hundred and fourteen children underwent surgical treatment, 112 of them (98.2%) had good postoperative reexamination. Only 2 cases (1.8%) died after surgery, and 14.0% (16/114) had the possibility of secondary surgery. Conclusions:Fetal complex CHD is not an indication for cesarean section, and the delivery mode could be selected according to the obstetric situation. If the mother and child are in stable condition, the delivery is planned after 39 weeks of gestation. For children with low oxygen saturation after birth, alprostadil could be pumped to maintain the open ductus arteriosus, and timely referral to the pediatric cardiac surgery for subsequent surgical treatment, which could achieve a good prognosis.
10.Carbon footprint accounting of traditional Chinese medicine extracts based on life cycle assessment: a case study of mulberry leaf extract from an enterprise.
Zhi-Min CI ; Jian-Xiang OU ; Qiang YU ; Chuan ZHENG ; Zhao-Qing PEI ; Li-Ping QU ; Ming YANG ; Li HAN ; Ding-Kun ZHANG
China Journal of Chinese Materia Medica 2025;50(1):120-129
Under the background of carbon peaking and carbon neutrality goals, the Ministry of Ecology and Environment, together with 15 national ministries and commissions, has formulated the Implementation Plan on Establishing a Carbon Footprint Management System, and it is urgent for traditional Chinese medicine(TCM) pharmaceutical enterprises to carry out research on carbon footprint accounting methods of related products. Based on the life cycle assessment(LCA) theory, taking mulberry leaf extract produced by a certain enterprise as an example, this study analyzed the carbon footprint of TCM extracts during the life cycle. The results show that for every 1 kg of product produced, the carbon emissions from the stages of raw material acquisition, transportation, and extract production are-20.569, 1.205, and 173.577 kgCO_2eq(CO_2 equivalent), respectively. The carbon footprint of the product is 154.213 kgCO_2eq·kg~(-1). In addition, the carbon emission is the highest in the production stage, in which the consumption of ethanol solvents makes the greatest contribution to the carbon footprint, accounting for 25.71%, more than one-fourth of the total carbon footprint. The second contribution was from the treatment process of TCM residues, accounting for 19.67%, closely followed by wastewater treatment(17.71%), the consumption of hot steam(17.43%), and drinking water(16.90%). The consumption of electric power and packaging materials has a smaller carbon emission of 2.58%. In particular, the carbon emission caused by the consumption of packaging materials is only 0.04%, which is negligible. The results of the study are expected to provide a reference for TCM enterprises to carry out research on the carbon footprint of products, offer ideas for collaborative innovation in reducing pollution and carbon emissions throughout the entire industry chain of TCM, and develop new quality productivity of modern TCM industry based on green and low-carbon manufacturing.
Morus/chemistry*
;
Plant Leaves/chemistry*
;
Carbon Footprint
;
Drugs, Chinese Herbal/chemistry*
;
Plant Extracts/analysis*
;
Medicine, Chinese Traditional

Result Analysis
Print
Save
E-mail