1.Methacrylated dermal extracellular matrix hydrogel promotes repair of abdominal wall defects
Zhongyu LIU ; Wenya LI ; Yonghong FAN ; Shuang LYU ; Juan PEI ; Yaqin CHEN ; Beiyu LIU ; Hongyu SUN
Chinese Journal of Tissue Engineering Research 2025;29(10):2074-2082
BACKGROUND:Synthetic polymers,such as polypropylene and polyester,used for the treatment of abdominal wall defects not only lack biodegradability and bioactivity but also fail to meet the demands of complex and irregular wounds.Therefore,finding bioactive materials with low immunogenicity and good histocompatibility has become a hot spot in the repair of abdominal wall defects. OBJECTIVE:To prepare methacryloyl modified dermal extracellular matrix hydrogel and explore its potential application in abdominal wall defect. METHODS:(1)The porcine dermis was acellular with 0.25%trypsin and 1%Triton X-100 in turn to obtain the dermal extracellular matrix.After pepsin digestion and methacrylic anhydride modification,the methacrylated dermal extracellular matrix hydrogel was formed by photocrosslinking.The microscopic morphology of the hydrogel was observed by scanning electron microscope,and its rheological properties,swelling properties and other physical and chemical properties were tested.(2)Mice fibroblasts(L929)were inoculated into methacrylated dermal extracellular matrix hydrogel to detect the cell compatibility.(3)Totally 12 SD rats were randomly divided into two groups(n=6)to create abdominal wall defect model with peritoneum preserved.The defect site of the polypropylene group was filled with polypropylene material,and the hydrogel group was filled with methacrylated dermal extracellular matrix hydrogel.The wound skin of both groups was covered with polypropylene material.The wound healing was observed and histological analysis was carried out. RESULTS AND CONCLUSION:(1)Enzymatic hydrolysis had a good decellularization effect on porcine dermis after decellularization,and the original glycosaminoglycans and collagen were well retained.Scanning electron microscope observation revealed that the dermal extracellular matrix hydrogel presented loose and porous structure.The aperture was between 70 and 120 μm.The swelling ratio was(16.88±3.24)%and the water absorption was(94.24±1.11)%.The rheological property test showed that the methacrylated dermal extracellular matrix hydrogel was stable and had shear thinning characteristics,with injectability.(2)CCK-8 assay and live/dead staining showed that methacrylated dermal extracellular matrix hydrogel had good cell compatibility.(3)The results of animal experiments showed that the skin wound healing rate of the experimental group was higher than that of the control group at 7,10,and 14 days after operation(P<0.05).Hematoxylin-eosin and Masson staining of skin and muscle tissue exhibited that compared with the polypropylene group,the skin wound epithelialization,hair follicle formation,collagen fiber arrangement,and neovascularization were better in the hydrogel group 14 days after surgery.The skin wound new tissue structure was similar to the normal tissue at 28 days after surgery,and scar hyperplasia was less.A small amount of muscle regeneration was observed on day 28 after operation.(4)The results show that the methacrylated dermal extracellular matrix hydrogel can promote wound skin healing and muscle tissue regeneration in rats with abdominal wall defect.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Influence and mechanism of bone marrow mesenchymal stem cells overexpressing growth arrest specific 6 on full-thickness skin defect wounds in diabetic mice
Pei LIU ; Chao WANG ; Qijian WEI ; Yuteng LI ; Lijun CUI ; Changchuan WANG ; Fan ZHANG ; Ling MA ; Xuan TIAN
Chinese Journal of Burns 2025;41(2):145-154
Objective:To investigate the influence and mechanism of bone marrow mesenchymal stem cells (BMSCs) overexpressing growth arrest specific 6, i.e. GAS6/BMSCs on full-thickness skin defect wounds in diabetic mice.Methods:This study was an experimental study. Twelve 8-week-old male C57BL/6J mice were divided into a control wound group with only full-thickness skin defects and a diabetic wound group with diabetic full-thickness skin defects according to the random number table method, with 6 mice in each group. The wound healing rates were calculated at 3, 7, 14, and 21 days after injury. At 21 days after injury, wound tissue specimens were collected for hematoxylin-eosin staining to observe the histopathological conditions; Masson staining was performed to detect collagen deposition; immunohistochemical staining was performed to detect the number of proliferating cell nuclear antigen (PCNA)-positive cells and CD31-positive cells, representing cell proliferation and capillary density, respectively; immunofluorescence staining was performed to detect the number of F4/80 and myeloperoxidase (MPO) double-positive cells, indicating efferocytosis. Two 4-week-old male C57BL/6J mice were used to extract BMSCs, and GAS6/BMSCs were constructed through adenovirus transfection and successfully identified. Eighteen 8-week-old male C57BL/6J mice were used to create diabetic full-thickness skin defect wound models and divided into phosphate buffered solution (PBS) group, BMSC group, and GAS6/BMSC group (with 6 mice in each group) according to the random number table method. Immediately after injury, PBS, BMSC single-cell suspension, and GAS6/BMSC single-cell suspension were injected locally into the wounds of the three groups of mice, respectively. The wound healing rates were calculated, and the cell proliferation, capillary density, and efferocytosis were detected at the same time points as the previous experiments.Results:At 3, 7, 14, and 21 days after injury, the wound healing rates of mice in diabetic wound group were significantly lower than those in control wound group (with t values of 7.99, 8.62, 9.80, and 5.85, respectively, P<0.05). Compared with those in control wound group, the wound tissue of mice in diabetic wound group showed the infiltration of a large number of inflammatory cells and reduced collagen deposition at 21 days after injury. At 21 days after injury, the number of PCNA-positive cells and CD31-positive cells in the wound tissue of mice in diabetic wound group were significantly less than that in control wound group (with t values of 6.61 and 5.38, respectively, P<0.05). At 21 days after injury, the number of F4/80 and MPO double-positive cells in the wound tissue of mice in diabetic wound group was 3.3±0.8, which was significantly less than 12.7±1.8 in control wound group ( t=11.00, P<0.05). At 14 and 21 days after injury, the wound healing rates of mice in BMSC group were significantly higher than those in PBS group ( P<0.05); at 3, 7, 14, and 21 days after injury, the wound healing rates of mice in GAS6/BMSC group were significantly higher than those in BMSC group ( P<0.05). At 21 days after injury, the number of PCNA-positive cells in the wound tissue of mice in BMSC group was significantly higher than that in PBS group ( P<0.05), and the number of PCNA-positive cells and CD31-positive cells in the wound tissue of mice in GAS6/BMSC group were significantly higher than that in BMSC group ( P<0.05). At 21 days after injury, the number of F4/80 and MPO double-positive cells in the wound tissue of mice in BMSC group was 4.2±1.2, which was similar to 3.5±1.1 in PBS group ( P>0.05); the number of F4/80 and MPO double-positive cells in the wound tissue of mice in GAS6/BMSC group was 8.2±1.2, which was significantly more than that in BMSC group ( P<0.05). Conclusions:Dysfunctional efferocytosis of macrophage exists in the full-thickness skin defect wounds of diabetic mice, while GAS6/BMSC can promote wound healing by restoring the efferocytosis of macrophages.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Review of chemical constituents, pharmacological effects, and quality control status of Eucommiae Cortex and prediction of its Q-markers.
Meng-Fan PENG ; Bao-Song LIU ; Pei-Pei YAN ; Cai-Xia LI ; Xiao-Fang ZHANG ; Yi ZHENG ; Ya-Gang SONG ; Tong LIU ; Lei YANG ; Ming-San MIAO
China Journal of Chinese Materia Medica 2025;50(4):946-958
Eucommiae Cortex, the dried bark of Eucommia ulmoides( Eucommiaceae), has both medicinal and edible values.Modern research has shown that Eucommiae Cortex contains various components such as flavonoids, lignans, iridoids, phenolic acids,terpenoids, and steroids, which have anti-osteoporosis, antioxidant, anti-inflammatory, blood glucose-lowering, and gastrointestinal tract-protecting effects. Eucommiae Cortex has applications in multiple fields such as healthcare, industry, and animal husbandry,demonstrating broad development prospects. This article reviews the chemical constituents, pharmacological effects, and quality control status of Eucommiae Cortex. Furthermore, according to the concept of quality marker(Q-marker), this article predicts the Q-markers of Eucommiae Cortex from traditional medicinal properties, traditional medicinal effects, new medicinal effects, measurability of chemical components, compatibility, harvesting periods, and geographical origins. The components such as pinoresinol diglucoside,chlorogenic acid, caffeic acid, quercetin, baicalein, baicalin, olivil, coniferyl ferulate, and kaempferol can be used as Q-markers for Eucommiae Cortex, which provide reference for establishing a systematic quality control system for Eucommiae Cortex.
Eucommiaceae/chemistry*
;
Drugs, Chinese Herbal/pharmacology*
;
Quality Control
;
Humans
;
Animals
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Experimental study of the ultraviolet A-riboflavin cross-linking corneal stro-mal lenticule punctal plug for the treatment of dry eyes in rabbits
Fan YANG ; Fang TIAN ; Cheng PEI ; Juan LI ; Yong LI ; Yi SHAO
Recent Advances in Ophthalmology 2025;45(4):286-290
Objective To investigate the efficacy of the ultraviolet A-riboflavin cross-linking corneal stromal lenticule punctal plug for the treatment of dry eyes in rabbits.Methods Thirty-two New Zealand white rabbits(64 eyes)were se-lected and randomly divided into a normal group,a model group,a conventional plug group and a cross-linking plug group,with 8 rabbits(16 eyes)in each group.Rabbits in the normal group were not treated.In the model group,moderate-to-se-vere dry eye rabbit models were constructed but no treatment was given.Rabbits in the conventional and cross-linking plug groups were implanted with conventional and cross-linking plugs after model construction,respectively.The tear film func-tions of the experimental rabbits,including tear secretion volume(SIT),corneal fluorescein sodium staining,tear film break-up time(BUT),and tear meniscus height(TMH),were detected before the intervention,1 day,1 week,2 weeks,and 4 weeks after the intervention.In addition,the corneas of each group were collected for hematoxylin and eosin(HE)staining to observe the changes of the corneal epithelium 4 weeks after the intervention.Finally,the non-cross-linking and cross-linking corneal stromal lenticules were placed separately in 1 g·L-1 of type Ⅰ collagenase to observe the change of the lenticule diameter over time.Results In the cross-linking plug group,the SIT,BUT and TMH values 2 and 4 weeks after the intervention were significantly higher than those before the intervention(all P<0.01).In the conventional plug group,the SIT,BUT and TMH values 4 weeks after intervention were significantly higher than those before the intervention(all P<0.01).After 4 weeks of intervention,the corneal staining of rabbits in the cross-linking plug group was better than that in the conventional plug group and model group.The HE staining results showed that in the cross-linking plug group,the corneal epithelial thickness of rabbits was basically normal,epithelial cells were basically arranged in order,and a single layer of columnar epithelial cells was observed on the basal layer.The dissolution time of the corneal stromal lenticule after cross-linking was significantly increased,compared with that of the non-cross-linking one.Conclusion The ultraviolet A-riboflavin cross-linking corneal stromal lenticule punctal plug has a more stable therapeutic effect on the rabbit dry-eye model than the conventional one,so it is expected to provide a novel approach for the clinical treatment of dry eyes.
10.Guideline for the prevention of intraoperative acquired pressure injury in paraplegic patients with spinal cord injury (version 2025)
Aijun XU ; Shuixia LI ; Bo CHEN ; Mengyuan YE ; Lejiao LANG ; Ning NING ; Lin ZHANG ; Changqing LIU ; Zhonglan CHEN ; Weihu MA ; Weishi LI ; Xiaoning WANG ; Dongmei BIAN ; Jiancheng ZENG ; Xin WANG ; Yuan GAO ; Yaping CHEN ; Jiali CHEN ; Yun HAN ; Xiuting LI ; Yang ZHOU ; Xiaojing SU ; Qiong ZHANG ; Tianwen HUANG ; Ping ZHANG ; Hua LIN ; Xingling XIAO ; Ruifeng XU ; Fanghui DONG ; Bing HAN ; Luo FAN ; Yanling PEI ; Suyun LI ; Xiaoju TAN ; Rongchen GUO ; Yefang ZOU ; Xiaoyun HAN ; Junqin DING ; Yi WANG ; Shuhua DENG ; Jinli GUO ; Yinhua LIANG ; Yuan CEN ; Xiaoqin LIU ; Junru CHEN ; Haiyang YU ; Lunlan LI ; Ying REN ; Yunxia LI ; Jianli LU ; Ying YING ; Lan WEI ; Yin WANG ; Qinhong XU ; Yanqin ZHANG ; Yang LYU ; Shijun ZHANG ; Sui WENJIE ; Sanlian HU ; Shuhong YANG ; Guoqing LI ; Jingjing AN ; Baorong HE ; Leling FENG
Chinese Journal of Trauma 2025;41(6):530-541
Paraplegia caused by spinal cord injury is a serious neurological complication, for which surgery is currently the main treatment method. Due to different surgical approaches, patients are usually expected to maintain a passive prone position for a long time or switch between the supine and prone positions. Affected by multiple factors such as neurogenic sensory disorders, pathological changes in muscle tone and operative duration, the risk of intraoperative acquired pressure injury (IAPI) is significantly increased. Current clinical prevention strategies for IAPI in these patients predominantly focus on localized pressure relief during positioning, lacking systematic, standardized comprehensive prevention protocols or evidence-based guidelines. To address it, Department of Nursing, Orthopedics Branch, China International Exchange and Promotive Association for Medical and Health Care, Spinal Trauma Professional Committee, Orthopedics Branch, Chinese Medical Doctor Association, Nursing Group of Spine and Spinal Cord Professional Committee of Chinese Association of Rehabilitation Medicine organized experts in relevant fields to formulate Guideline for the prevention of intraoperative acquired pressure injury in paraplegic patients with spinal cord injury ( version 2025), based on evidence-based medical evidence and latest research results and clinical practice at home and abroad. Eleven recommendations were put forward from the aspects of preoperative risk assessment, intraoperative prevention strategies, postoperative handover and monitoring, and supportive mechanisms for IAPI prevention, aiming to standardize the prevention measures and management strategies of IAPI in paraplegic patients with spinal cord injury and accelerate the recovery of patients and improve the therapeutic effect.

Result Analysis
Print
Save
E-mail