1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Immunotherapy for Lung Cancer
Pei-Yang LI ; Feng-Qi LI ; Xiao-Jun HOU ; Xue-Ren LI ; Xin MU ; Hui-Min LIU ; Shou-Chun PENG
Progress in Biochemistry and Biophysics 2025;52(8):1998-2017
Lung cancer is the most common malignant tumor worldwide, ranking first in both incidence and mortality rates. According to the latest statistics from the International Agency for Research on Cancer (IARC), approximately 2.5 million new cases and around 1.8 million deaths from lung cancer occurred in 2022, placing a tremendous burden on global healthcare systems. The high mortality rate of lung cancer is closely linked to its subtle early symptoms, which often lead to diagnosis at advanced stages. This not only complicates treatment but also results in substantial economic losses. Current treatment options for lung cancer include surgery, radiotherapy, chemotherapy, targeted drug therapy, and immunotherapy. Among these, immunotherapy has emerged as the most groundbreaking advancement in recent years, owing to its unique antitumor mechanisms and impressive clinical benefits. Unlike traditional therapies such as radiotherapy and chemotherapy, immunotherapy activates or enhances the patient’s immune system to recognize and eliminate tumor cells. It offers advantages such as more durable therapeutic effects and relatively fewer toxic side effects. The main approaches to lung cancer immunotherapy include immune checkpoint inhibitors, tumor-specific antigen-targeted therapies, adoptive cell therapies, cancer vaccines, and oncolytic virus therapies. Among these, immune checkpoint inhibitors and tumor-specific antigen-targeted therapies have received approval from the U.S. Food and Drug Administration (FDA) for clinical use in lung cancer, significantly improving outcomes for patients with advanced non-small cell lung cancer. Although other immunotherapy strategies are still in clinical trials, they show great potential in improving treatment precision and efficacy. This article systematically reviews the latest research progress in lung cancer immunotherapy, including the development of novel immune checkpoint molecules, optimization of treatment strategies, identification of predictive biomarkers, and findings from recent clinical trials. It also discusses the current challenges in the field and outlines future directions, such as the development of next-generation immunotherapeutic agents, exploration of more effective combination regimens, and the establishment of precise efficacy prediction systems. The aim is to provide a valuable reference for the continued advancement of lung cancer immunotherapy.
7.Optimization of extraction process for Shenxiong Huanglian Jiedu Granules based on AHP-CRITIC hybrid weighting method, grey correlation analysis, and BP-ANN.
Zi-An LI ; De-Wen LIU ; Xin-Jian LI ; Bing-Yu WU ; Qun LAN ; Meng-Jia GUO ; Jia-Hui SUN ; Nan-Yang LIU ; Hui PEI ; Hao LI ; Hong YI ; Jin-Yu WANG ; Liang-Mian CHEN
China Journal of Chinese Materia Medica 2025;50(10):2674-2683
By employing the analytic hierarchy process(AHP), the CRITIC method(a weight determination method based on indicator correlations), and the AHP-CRITIC hybrid weighting method, the weight coefficients of evaluation indicators were determined, followed by a comprehensive score comparison. The grey correlation analysis was then performed to analyze the results calculated using the hybrid weighting method. Subsequently, a backpropagation-artificial neural network(BP-ANN) model was constructed to predict the extraction process parameters and optimize the extraction process for Shenxiong Huanglian Jiedu Granules(SHJG). In the extraction process, an L_9(3~4) orthogonal experiment was designed to optimize three factors at three levels, including extraction frequency, water addition amount, and extraction time. The evaluation indicators included geniposide, berberine, ginsenoside Rg_1 + Re, ginsenoside Rb_1, ferulic acid, and extract yield. Finally, the optimal extraction results obtained by the orthogonal experiment, grey correlation analysis, and BP-ANN method were compared, and validation experiments were conducted. The results showed that the optimal extraction process involved two rounds of aqueous extraction, each lasting one hour; the first extraction used ten times the amount of added water, while the second extraction used eight times the amount. In the validation experiments, the average content of each indicator component was higher than the average content obtained in the orthogonal experiment, with a higher comprehensive score. The optimized extraction process parameters were reliable and stable, making them suitable for subsequent preparation process research.
Drugs, Chinese Herbal/analysis*
;
Neural Networks, Computer
8.Trend in testicular volume change after orchiopexy in 854 children with cryptorchidism.
Ying-Ying HE ; Zhi-Cong KE ; Shou-Lin LI ; Hui-Jie GUO ; Pei-Liang ZHANG ; Peng-Yu CHEN ; Wan-Hua XU ; Feng-Hao SUN ; Zhi-Lin YANG
Asian Journal of Andrology 2025;27(6):723-727
The aim of this study was to investigate the trend in testicular volume changes after orchiopexy in children with cryptorchidism. The clinical data of 854 children with cryptorchidism who underwent orchiopexy between January 2013 and December 2016 in Shenzhen Children's Hospital (Shenzhen, China) were retrospectively analyzed. The mean (standard deviation) age of the patients was 2.8 (2.5) years, and the duration of follow-up ranged from 1 year to 5 years. Ultrasonography was conducted preoperatively and postoperatively. The variables analyzed included age at the time of surgery, type of surgical procedure, laterality, preoperative testicular position, preoperative and postoperative testicular volumes, and the testicular volume ratio of them. The average testicular volumes preoperatively and at 1 year, 2 years, 3 years, and 5 years postoperatively were 0.27 ml, 0.38 ml, 0.53 ml, 0.87 ml, and 1.00 ml, respectively ( P < 0.001). The corresponding testicular volume ratios were 0.67, 0.76, 0.80, 0.83, and 0.84 ( P < 0.001). The mean volume of the undescended testes was significantly smaller than the mean normative value ( P < 0.001, lower than the 10 th percentile). The postoperative testicular volumes in children with cryptorchidism were generally lower than those in healthy boys but were still greater than the 10 th percentile and exhibited an increasing trend. The older the child is at the time of surgery, the larger the gap in volume between the affected and normal testes. Although testicular volume tends to gradually increase after orchiopexy for cryptorchidism, it could not normalizes. Earlier surgery results in affected testicular volumes closer to those of healthy boys.
Humans
;
Male
;
Cryptorchidism/diagnostic imaging*
;
Orchiopexy
;
Child, Preschool
;
Testis/surgery*
;
Retrospective Studies
;
Organ Size
;
Ultrasonography
;
Infant
;
Child
;
Postoperative Period
;
Follow-Up Studies
9.Efficacy and Safety of Venetoclax in Combination with Hypomethylating Agents for the Treatment of High-Risk Myelodysplastic Syndromes.
Yang XU ; Jian ZHANG ; Zhi-Hong LIN ; Jun CHEN ; Li-Min LIU ; Hui-Ying QIU ; De-Pei WU
Journal of Experimental Hematology 2025;33(1):168-174
OBJECTIVE:
To investigate the clinical efficacy and safety of venetoclax (VEN) in combination with hypomethylating agent (HMA) in the treatment of patients with high-risk myelodysplastic syndromes (MDS).
METHODS:
A total of 30 patients with high-risk MDS who received the combination of VEN and HMA from March 2019 to November 2022 were included. The overall response rate (ORR), modified overall response rate (mORR), overall survival (OS), progression-free survival (PFS), and adverse events of all included patients were evaluated.
RESULTS:
Among the 30 high-risk MDS patients treated with VEN combined with HMA regimen, 24 cases achieved complete response (CR)/ marrow complete response (mCR), 2 cases achieved partial response (PR), the ORR was 24/30, the median OS was 28.1 months, and the median PFS was 28.1 months. In addition, patients who achieved complete remission / marrow complete remission after treatment had a significantly longer OS than those who did not. Moreover, 12 patients were treated with allogeneic hematopoietic stem cell transplantation (allo-HSCT). There were grade 3 or higher hematologic adverse events including thrombocytopenia (14 cases), neutropenia (14 cases), febrile neutropenia (10 cases) and anemia (7 cases) as well as gastrointestinal adverse events of any grade, such as vomiting (7 cases), diarrhea (5 cases), and constipation (4 cases).
CONCLUSION
VEN in combination with HMA is an effective and safe treatment option in patients with high-risk MDS. This regimen combined with allo-HSCT can improve the prognosis of these patients. Continuous attention to the monitoring and management of adverse events is essential for the patients' safety in this combination therapy.
Humans
;
Myelodysplastic Syndromes/drug therapy*
;
Sulfonamides/therapeutic use*
;
Bridged Bicyclo Compounds, Heterocyclic/therapeutic use*
;
Female
;
Male
;
Treatment Outcome
;
Middle Aged
;
Aged
;
Antineoplastic Combined Chemotherapy Protocols/therapeutic use*
;
Adult
10.Identification of Complex Samples Based on Broad Learning System and Physicochemical Indicators
Jia-Qi XIE ; Qiang ZHANG ; Pei-Ran LIU ; Ya-Fei YANG ; Xi-Hui BIAN
Chinese Journal of Analytical Chemistry 2025;53(6):944-954,中插16-中插21
Compared to traditional machine learning algorithms,which often suffer from low feature extraction efficiency,insufficient nonlinear pattern recognition capabilities and slow training speeds,the broad learning system(BLS)enhances the learning ability and efficiency by horizontally expanding the network structure.BLS offers advantages such as a simple structure,fast training speed,and strong generalization capabilities.While BLS has demonstrated potential in various fields,but its application in identification of complex samples has not been fully explored.This research investigated the feasibility of using BLS algorithm for identification of complex samples based on physicochemical indicators.Using the iris,wine,and breast cancer datasets,the length and width of petals and sepals of iris flowers,the physicochemical properties of wine,and the nuclear characteristics of breast cancer cells were used as input variables to establish BLS models for identifying iris species,wine varieties,and benign versus malignant nucleus.The model performance was evaluated by confusion matrices,accuracy,and runtime.Compared with partial least squares-discriminant analysis(PLS-DA),soft independent modeling of class analogies(SIMCA),and artificial neural networks(ANN),the results indicated that BLS demonstrated significant advantages in computational efficiency and recognition accuracy.Thus,BLS was an efficient and reliable method for identification of complex samples.

Result Analysis
Print
Save
E-mail