1.Olfactory Receptors Expressed in The Intestine and Their Functions
Pei-Wen YANG ; Meng-Meng YUAN ; Ying ZHOU ; Peng LI ; Gui-Hong QI ; Ying YANG ; Zhong-Yi MAO ; Meng-Sha ZHOU ; Xiao-Shuang MAO ; Jian-Ping XIE ; Yi-Nan YANG ; Shi-Hao SUN
Progress in Biochemistry and Biophysics 2026;53(3):534-549
Olfactory receptors (ORs) form the largest superfamily of G protein-coupled receptors (GPCRs). Traditionally recognized for their role in the nasal olfactory epithelium, where they mediate the sense of smell, accumulating evidence has firmly established their ectopic expression in non-olfactory tissues, including the intestine, lungs, and kidneys. The intestine, as the primary site for nutrient digestion and absorption, harbors a highly complex chemical environment. To adapt to this environment, the gut employs a sophisticated network of “chemosensors” to monitor luminal contents and maintain homeostasis. Among these sensors, intestinal ORs have emerged as crucial functional components, serving as a molecular bridge that connects environmental chemical signals—such as food-derived odorants—to specific physiological responses. This discovery has significantly deepened our understanding of how dietary flavors and compounds influence intestinal physiology at the molecular level. This review systematically summarizes the expression profiles, ligand classification, and biological functions of ORs within the gastrointestinal tract. Studies indicate that intestinal ORs exhibit distinct spatial distribution patterns across different gut segments and display cell-type specificity, particularly within enterocytes and enteroendocrine cells. These receptors function as versatile sensors capable of recognizing a wide variety of ligands, including exogenous dietary components, gut microbiota metabolites such as short-chain fatty acids, and endogenous small molecules like azelaic acid. Upon activation by specific ligands, intestinal ORs trigger intracellular signaling cascades, primarily involving the AC-cAMP-PKA pathway or calcium influx channels. A major focus of this review is to elucidate the molecular mechanisms by which these receptors regulate the secretion of gut hormones. Activation of specific ORs in enteroendocrine cells has been shown to stimulate the release of hormones such as glucagon-like peptide-1 (GLP-1), peptide YY (PYY), and serotonin (5-HT), thereby modulating systemic energy metabolism, glucose homeostasis, and gastrointestinal motility. Furthermore, the review addresses the critical roles of ORs in immune regulation and pathology. Evidence suggests that specific ORs contribute to the maintenance of intestinal immune homeostasis and may offer protection against inflammation. Beyond their involvement in inflammatory responses, ORs such as Olfr78 have been shown to regulate the differentiation and function of intestinal endocrine cells. Similarly, Olfr544 has been demonstrated to alleviate intestinal inflammation by remodeling the gut microbiome and metabolome. These findings collectively suggest that specific ORs hold promise as therapeutic targets for mitigating intestinal inflammation and maintaining gut homeostasis. Additionally, the review explores the emerging role of ORs in cancer. Although OR expression is often downregulated in tumor tissues compared to normal mucosa, activation of specific ORs by certain ligands can inhibit tumor cell proliferation and migration and induce apoptosis via pathways such as MEK/ERK and p38 MAPK. Conversely, other receptors, such as OR7C1, may serve as biomarkers for cancer-initiating cells. In conclusion, intestinal ORs represent a vital component of the gut’s sensory network. The review also discusses the translational potential of these findings. By elucidating the precise pairing relationships between dietary components and specific ORs, novel therapeutic strategies could be developed. Intestinal ORs may thus emerge as promising targets for nutritional and pharmacological interventions in metabolic diseases, inflammatory bowel diseases, and malignancies.
2.Correlation between bone mass loss and incidence of knee osteoarthritis in the elderly community-based population.
Chen-Jie XIA ; Jin LI ; Xiang LI ; Ke ZHOU ; Liang FANG ; Hong-Ting JIN ; Pei-Jian TONG
China Journal of Orthopaedics and Traumatology 2025;38(4):358-363
OBJECTIVE:
To explore the epidemiological characteristics of knee osteoarthritis (KOA) among the elderly in the community, and its correlation with bone mass loss.
METHODS:
A cross-sectional study was conducted on elderly community population over 50 year old from 12 community health service centers in Zhejiang province. Their gender, age, body mass index (BMI), T value and KOA diagnosis were collected using face to face questionnaire survey. Univariate regression was used to analyze the influence of age, gender, BMI and bone loss on KOA. Logistic multivariate regression model was used to analyze the independent effect of bone mass loss on KOA.
RESULTS:
Among 4 173 subjects in this study, 1 710 of them were had a KOA. The prevalence rate was 40.9%. The mean age, the proportion of females and the mean BMI in KOA patients were (65.5±3.8) years old, 67.7%(1 158/1 710) and(24.59±1.28) kg·m-2, respectively, which were significantly higher than (58.5±3.2) years old, 51.3%(1 263/2 463), and (23.48±1.25) kg·m-2 in non-KOA subjects (P<0.001). In the population aged from 60 to 69 years old, the influence of osteopenia and osteoporosis on the prevalence of KOA was[OR=1.21, 95%CI(1.00, 1.46), P=0.053 2], [OR=1.42, 95%CI(1.14, 1.78), P=0.002 2]. The influence of male and female osteoporosis on the prevalence of KOA was [OR=1.52, 95%CI(1.16, 1.99), P=0.002 7] and [OR=1.87, 95%CI(1.51, 2.32), P<0.000 1], respectively. In the population of 24 kg·m-2≤BMI<28 kg·m-2, the influence of osteopenia and osteoporosis on the prevalence of KOA was [OR=1.47, 95%CI(1.21, 1.80), P=0.000 1], [OR=2.69, 95%CI(2.11, 3.42), P<0.000 1], respectively. After controlling the confounding factors of age, gender and BMI, compared with people with normal bone mass, the effect of osteopenia on the prevalence of KOA was [OR=1.34, 95%CI(1.08, 1.67), P=0.009 2], and the effect of osteoporosis on the prevalence of KOA was [OR=1.38, 95%CI(1.06, 1.79), P=0.017 9].
CONCLUSION
Elderly overweight women are more likely to develop KOA. Bone mass loss is an independent risk factor for KOA, which will significantly increase the prevalence of KOA in people overweight or aged 60 to 69 years old.
Humans
;
Female
;
Male
;
Aged
;
Osteoarthritis, Knee/etiology*
;
Middle Aged
;
Cross-Sectional Studies
;
Bone Density
;
Aged, 80 and over
;
Incidence
;
Body Mass Index
;
China/epidemiology*
;
Osteoporosis/epidemiology*
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Colorimetric Sensor for Determination of Golgi Protein 73 Based on Hemin-Reduced Graphene Oxide-Manganese Dioxide Nanozyme
Xiao-Hong TAN ; Jia-Hao ZHOU ; Pei-Hong XU ; Hao LIN ; Gui-Yin LI
Chinese Journal of Analytical Chemistry 2025;53(9):1476-1485
Hepatocellular carcinoma(HCC)is one of common cancer that seriously endangers human health.Designing methods for early,rapid,and accurate diagnosis of HCC has become the key point.Golgi protein 73(GP73),a novel potential biomarker for HCC,is crucial for diagnosis and treatment of HCC.In this study,a colorimetric sensor with rapidity,smplicity and high specificity was established for detection of GP73 based on peroxidase-like activity of hemin-reduced graphene oxide-manganese dioxide(H-rGO-MnO2).The H-rGO-MnO2-GP73Apt1 signal probe was synthesized by carboxyl of H-rGO-MnO2 nanozyme and amination of GP73 aptamer(GP73Apt1)though amide reaction.In the presence of GP73,the sulfhydryl-modifed GP73 aptamer(GP73Apt2),as the capture probe,and the signal probe both specifically recognized GP73,forming a sandwich structure(GP73Apt2-GP73-H-rGO-MnO2-GP73Apt1).This structure could catalyze the oxidation of H2O2 to produce hydroxyl radical(·OH),thereby oxidizing the colorless phthalenediamine(OPD)into the yellow 2,3-diaminophenazine(DPA).The quantitative detection of GP73 was achieved by measuring the characteristic absorbance of DPA at 450 nm.In the GP73 concentration range of 10-150 ng/mL,there was a good linear relationship between the DPA absorbance at 450 nm(A450 nm)and the GP73 concentration under optimal conditions.The linear equation was A450 nm=0.00321CGP73+0.8988,with the correlation coefficient(R2)of 0.9960 and the detection limit(LOD)of 5.38 ng/mL.The colorimetric sensor was applied to detection of GP73 in human serum samples,with recoveries of 88.4%?98.8%.This sensor showed high specificity,sensitivity,and stability,and had potential for clinical detection of GP73,providing a new approach for the early diagnosis of HCC.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
10.Dosimetric study of radiotherapy synchronized with 3D printing-based tumor treating fields for glioblastoma
Zhongwei LI ; Xuwei LU ; Di WU ; Jianfeng TAN ; Zaijie HUANG ; Pei YANG ; Yujuan ZHOU ; Hong LIU
Chinese Journal of Medical Physics 2025;42(6):712-718
Objective To investigate the dosimetric effects of tumor treating fields(TTFields)patches on different radiotherapy modes for glioblastoma(GBM)patients who wear TTFields patches during radiotherapy,thereby providing dosimetric guidance for determining the appropriate radiotherapy mode.Methods With the TTFields data from GBM patients,artifact-free radiotherapy CT images were obtained utilizing 3D-printed TPU TTFields patches(3D-Print-TTFields)and anthropomorphic phantoms,and then a TTFields-synchronized radiotherapy image model was constructed.Furthermore,the treatment planning system was used to construct a dosimetric calculation model for TTFields-synchronized radiotherapy by simulating and fitting the ray attenuation rate of TTFields patches measured by accelerators.Using these models,3 kinds of radiotherapy plans were simulated and developed.Specifically,P1 simulated the conventional radiotherapy mode;P2 simulated the TTFields-combined radiotherapy mode(TTF-Com-RT),in which patients underwent radiotherapy using the P1 plan while wearing TTFields patches;and P3 simulated the TTFields-synchronized radiotherapy(TTF-Syn-RT)mode where the TTFields patches were worn throughout the entire radiotherapy process.The paired t-test was used to analyze dosimetric parameters such as target dose(D95),average scalp dose(D-skin),conformity index(CI)and homogeneity index(HI)in 3 plans(P1,P2,and P3),as well as the D95 and D-skin parameters for intensity-modulated radiotherapy(IMRT)and volumetric modulated arc therapy(VMAT)techniques in the P3 plan.Results The D95 simulated by P2 decreased by 1.35%as compared with P1(P<0.05),and the D95 simulated by P3 was 1.31%higher than that in P2(P<0.05).Compared with P1,P2 and P3 increased the D-skin by 12.56%and 14.30%,respectively(P<0.05),and the D-skin simulated by P3 increased by 1.55%as compared with P2(P<0.05).However,there were trivial differences in D95 between P3 and P1,CI and HI among all plans,D95 and D-skin between IMRT and VMAT techniques in P3 plan(P>0.05).Conclusion Based on GBM patient data,CT simulation images obtained from 3D-Print-TTFields combined with anthropomorphic phantom are artifact-free and meet radiotherapy requirements.The target and scalp dose differences between TTF-Com-RT and TTF-Syn-RT are less than 2%,and the dosimetric difference of TTF-Syn-RT using IMRT/VMAT techniques is insignificant.Therefore,clinicians can choose radiotherapy modes and techniques according to actual needs.

Result Analysis
Print
Save
E-mail