1.Hippocampal Extracellular Matrix Protein Laminin β1 Regulates Neuropathic Pain and Pain-Related Cognitive Impairment.
Ying-Chun LI ; Pei-Yang LIU ; Hai-Tao LI ; Shuai WANG ; Yun-Xin SHI ; Zhen-Zhen LI ; Wen-Guang CHU ; Xia LI ; Wan-Neng LIU ; Xing-Xing ZHENG ; Fei WANG ; Wen-Juan HAN ; Jie ZHANG ; Sheng-Xi WU ; Rou-Gang XIE ; Ceng LUO
Neuroscience Bulletin 2025;41(12):2127-2147
Patients suffering from nerve injury often experience exacerbated pain responses and complain of memory deficits. The dorsal hippocampus (dHPC), a well-defined region responsible for learning and memory, displays maladaptive plasticity upon injury, which is assumed to underlie pain hypersensitivity and cognitive deficits. However, much attention has thus far been paid to intracellular mechanisms of plasticity rather than extracellular alterations that might trigger and facilitate intracellular changes. Emerging evidence has shown that nerve injury alters the microarchitecture of the extracellular matrix (ECM) and decreases ECM rigidity in the dHPC. Despite this, it remains elusive which element of the ECM in the dHPC is affected and how it contributes to neuropathic pain and comorbid cognitive deficits. Laminin, a key element of the ECM, consists of α-, β-, and γ-chains and has been implicated in several pathophysiological processes. Here, we showed that peripheral nerve injury downregulates laminin β1 (LAMB1) in the dHPC. Silencing of hippocampal LAMB1 exacerbates pain sensitivity and induces cognitive dysfunction. Further mechanistic analysis revealed that loss of hippocampal LAMB1 causes dysregulated Src/NR2A signaling cascades via interaction with integrin β1, leading to decreased Ca2+ levels in pyramidal neurons, which in turn orchestrates structural and functional plasticity and eventually results in exaggerated pain responses and cognitive deficits. In this study, we shed new light on the functional capability of hippocampal ECM LAMB1 in the modulation of neuropathic pain and comorbid cognitive deficits, and reveal a mechanism that conveys extracellular alterations to intracellular plasticity. Moreover, we identified hippocampal LAMB1/integrin β1 signaling as a potential therapeutic target for the treatment of neuropathic pain and related memory loss.
Animals
;
Laminin/genetics*
;
Hippocampus/metabolism*
;
Neuralgia/metabolism*
;
Cognitive Dysfunction/etiology*
;
Male
;
Peripheral Nerve Injuries/metabolism*
;
Extracellular Matrix/metabolism*
;
Integrin beta1/metabolism*
;
Pyramidal Cells/metabolism*
;
Signal Transduction
2.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
3.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
4.Bioequivalence study of olmesartan medoxomil tablet in Chinese healthy subjects
Na SHAN ; Da-Hai JIANG ; Lin-Lin MIAO ; Zhen-Li REN ; Peng-Bo JIN ; Pei-Qi HAO ; Li AN ; Hong ZHU ; Yong XIN ; Guang-De YANG ; Feng LIU
The Chinese Journal of Clinical Pharmacology 2024;40(20):3033-3037
Objective To study the bioequivalence of test and reference olmesartan tablet in Chinese healthy subjects after single dose under fasting and fed conditions.Methods A single-center,random,open,single-dose,two-preparations,double-period,crossover study was adopted.A total of 48 healthy adult male and female subjects(24 cases of fasting test and 24 cases of fed test)were included in the random crossover administration.Single oral dose 20 mg of test and reference were taken under fasting and postprandial conditions,respectively.Plasma concentration of olmesartan in plasma were determined by liquid chromatography tandem mass spectrometry.The main pharmacokinetic parameters were calculated by Phoenix WinNonlin 8.0 software.Results The main pharmacokinetic parameters of the test and reference preparations of olmesartan tablets in the fasting group were as follows:Cmax were(653.06±133.53)and(617.37±151.16)ng·mL-1,AUC0-t were(4 201.18±1 035.21)and(4 087.38±889.99)ng·mL-1·h,AUC0-∞ were(4 254.30±1 058.90)and(4 135.69±905.29)ng·mL-1·h.The main pharmacokinetic parameters of the test and reference preparations of olmesartan tablets in the postprandial group were as follows:Cmax were(574.78±177.05)and(579.98±107.74)ng·mL-1,AUC0-t were(3 288.37±866.06)and(3 181.51±801.06)ng·mL-1·h,AUC0-∞ were(3 326.11±874.26)and(3 242.01±823.09)ng·mL-1·h.Under fasting and postprandial conditions,the 90%confidence intervals of the main pharmacokinetic parameters of the test and reference preparations are both 80.00%-125.00%.Conclusion Under fasting and postprandial conditions,a single oral dose of test and reference preparations olmesartan tablets in Chinese healthy adult volunteers showed bioequivalence.
5.Meta-analysis on the incidence of long COVID in Omicron-infected pa-tients
Li-Yu WANG ; Shi-Wei WU ; Meng-Qi XU ; Bao-Guang LIU ; Lan-Ying PEI ; Guo-Li YAN ; Guan-Min ZHENG
Chinese Journal of Infection Control 2024;23(11):1384-1390
Objective To explore the incidence of long CO VID symptoms in patients infected with Omicron variant of severe acute respiratory syndrome coronavirus 2(SARS-CoV-2).Methods According to the inclusion and exclu-sion criteria of literatures,relevant studies without language restrictions published up to 2024 were retrieved from both Chinese and English databases.The Chinese databases were China National Knowledge Infrastructure(CNKI),Wanfang Database,and VIP databases,and the foreign databases were PubMed,Embase,and Web of Science.Three-step screening was used to select literatures,and Stata 17.0 software was used for analysis.Results The incidence of at least one sequelae in patients infected with Omicron variant was 29.62%.The most common symptoms included fatigue(19.10%),joint or muscle pain(11.06%),memory loss(9.71%),brain fog(8.80%),cough(8.42%),headache(7.26%),and sore throat(6.68%).Subgroup analysis results showed that with the extension of follow-up(3 months vs 6 months),the incidence of smell or taste changes was significantly re-duced(7.22%vs 0.78%).The higher the proportion of women(<50%vs 50%-65%vs>65%),the higher the incidence of joint or muscle pain(1.09%vs 4.62%vs 19.53%);the greater the median age(≥45 years vs<45 years),the higher the incidence of chest pain or chest distress(0.90%vs 3.86%),all with statistically significant differences(all P<0.05).Conclusion Incidence of long COVID in Omicron-infected patients is high and can cause various symptoms.Follow-up time,median age and gender proportion have significant impacts on the incidence of some symptoms.
6.Morphological classification and molecular identification of Hyalomma asiaticum in parts of Xindi Township,Xinjiang
Xiao-Qing ZAN ; Qiao-Yun REN ; Jin LUO ; Yan-Long WANG ; Pei-Wen DIAO ; Li-Yan CHE ; Jian-Xun LUO ; Hong YIN ; Gui-Quan GUAN ; Guang-Yuan LIU ; Hong-Xi ZHAO
Chinese Journal of Zoonoses 2024;40(4):289-294
The purpose of this study was to identify the tick species native to Xindi Township,Yumin County,Xinjiang,China.Preliminary morphological identification of parasitic ticks collected from animals in the area was conducted with an ultra-depth of field three-dimensional VHX 600 digital stereo microscope.Total DNA of the ticks was extracted,amplified by PCR based on the COI and ITS2 gene loci,and the posi-tive PCR products were sequenced.The sequence were a-ligned with reference sequences from the NCBI database were aligned with the Basic Local Alignment Search Tool.A genet-ic phylogenetic tree was generated with the neighbor-joining method of MEGA 7.0 software to determine the evolutionary biological characteristics of ticks.Morphological identification showed that the ticks collected from Xindi Township of Yu-min County were consistent with the characteristics of Hya-lomma asiaticum.An evolutionary tree based on the COI and ITS2 gene sequences showed that the ticks collected in this study were clustered with known H.asiaticum sequences.The PCR products of COI and ITS2 were sequenced and compared,which confirmed that the collected tick species were H.asiaticum,in agreement with the morphological and molecular biological results.These findings help to clarify the distribution of ticks in Xindi Township of Xinjiang,and provide basic data for the analysis of tick genetic and evolutionary characteristics,as reference for surveillance and control of ticks in the Xinjiang Uygur Autonomous Region.
7.Study on fatigue vibration evaluation of ultrasonic knife tip based on Q factor
Ke-Sheng WANG ; Ze-Kai LI ; Pei LIU ; Jing-Sheng SUN ; Xu-Guang PENG ; Shuang-Shuang LI ; Qian-Hong HE ; Zhen LIU
Chinese Medical Equipment Journal 2024;45(6):17-22
Objective To propose a Q factor-based fatigue vibration evaluation method of the ultrasonic knife tip.Methods Firstly,an ultrasonic cutter fatigue testing table was established to realize repeated cutting,which was composed of a power supply module,a three-axis moving module,an ultrasonic cutter clamping module and a control module.Secondly,10 ultrasonic knives of some brand underwent fatigue testing with the table,during which non-contact measurement of the ultrasonic knife tip vibration was carried out and the Q factors were calculated at the five periods of the fatigue test,including the periods before cutting,after 500 times of cutting,after 1 000 times of cutting,after 2 000 times of cutting and after 3 000 times of cutting.Finally,the average cutting speed and burst pressure for coagulated vessels were computed at each period to validata the effectiveness of the method proposed.Results It's indicated that Q factor could effectively reflect the fatigue degradation of the ultrasonic knife tip,while the average cutting speed and burst pressure for coagulated vessels were difficult to efficiently evaluate the fatigue degradation level of the ultrasonic knife tip due to the uncertainty factors in the measurement process.Conclusion The proposed Q factor-based evaluation method can directly evaluate fatigue vibration of the ultrasonic knife tip in an accurate and quantitative manner.[Chinese Medical Equipment Journal,2024,45(6):17-22]
8.Accurate quantitative evaluation of MRI scanning noise based on laser vibrometry technology
Ke-Sheng WANG ; Pei-Jia XU ; Pei LIU ; Jing-Sheng SUN ; Ze-Kai LI ; Xu-Guang PENG ; Shuang-Shuang LI ; Qian-Hong HE ; Zhen LIU
Chinese Medical Equipment Journal 2024;45(10):20-24
Objective To carry out accurate quantative evaluation of MRI scanning noise based on laser vibrometry technology.Methods Skull and spine MRI was performed with mute and conventional sequences.A laser vibrometry device was used to sample the surface vibration noise at the outer edge of the inspection hole of MRI system according to GB/T 16539-1996 Acoustics—Determination of sound power levels of noise sources using vibration velocity—Measurement for seal machinery,and the indicators of sound power level,sound pressure level and perceived noise level obtained by the three calculation methods(LPN1,LPN2 and LPN3)were analyzed with some dedicated MRI noise analysis software.Results The peak sound pressure levels for conventional and mute sequences of skull scanning were 81 and 63 dB(A),respectively,and mute sequence reduced the noise level significantly;the peak sound pressure levels for conventional and mute sequences of spine scanning were 79 and 75 dB(A),respectively,and the noise reduction level was significantly lower than that of skull scanning.Significant differences in noise reduction were not found in spine scanning sequences,while were found in skull scanning sequences.During spine and skull scanning LPN1,LPN2 and LPN3 obtained by the three calculation methods of conventional and mute sequences were all higher than the overall sound power and overall pressure levels obviously.Conclusion Mute sequence can not realize linear noise reduction for the whole frequency band,the perceived noise of the human ear during MRI scanning is related directly to the scanning sequence,and there may be some bias when only one physical indicator is involved in the noise evaluation of MRI system.[Chinese Medical Equipment Journal,2024,45(10):20-24]
9.Image-guided Strategy of Intensity-modulated Radiotherapy in Helical Tomography for Nasopharyngeal Carcinoma
Meng-xue HE ; Pei-xun XU ; Hong HUANG ; Xuan-guang CHEN ; Hui-lang HE ; Zi-xian ZHANG ; Hui LIU ; Sen-kui XU ; Wen-yan YAO
Journal of Sun Yat-sen University(Medical Sciences) 2023;44(1):131-137
ObjectiveThis study aimed to analyze the difference in setup error before and after correction of systematic error. To determine the most appropriate image-guided strategy during HT treatment, we use different scanning ranges and image-guidance frequencies in patients with nasopharyngeal carcinoma (NPC) treated with helical tomotherapy (HT). MethodsFifteen patients with NPC who received HT treatment in Sun Yat-sen University Cancer Center from October 2019 to February 2020 were selected. Megavoltage computed tomography (MVCT) scanning was performed before each treatment. After five times of radiotherapy, system-error correction was performed to adjust the setup center. The setup errors before and after the correction of systematic errors, as well as the setup errors of different scanning ranges and different scanning frequencies, were collected for analysis and comparison. ResultsWhen comparing the setup errors before and after the correction of systematic error, the differences in setup errors in the left–right (LR), superior–inferior (SI), and anterior–posterior (AP) directions were statistically significant (P<0.05).The different scanning ranges of "nasopharynx + neck" and "nasopharynx" were compared, and a statistically significant difference was found in yaw rotational errors (P<0.05). In the comparison of daily and weekly scan frequency after system-error correction, a significant difference was found in AP direction (P<0.05). ConclusionDuring radiotherapy for NPC, the systematic error can be corrected according to the first five setup errors, and then small-scale scanning was selected for image-guided radiotherapy every day.
10.Correlation between axial lengths and anterior segment parameters evaluated by swept-source optical coherence tomography
Min ZHANG ; Guang-Qi AN ; Pei LIU ; Fan YANG ; Bo JIN ; Xue-Min JIN ; Li-Ping DU
International Eye Science 2023;23(8):1338-1342
AIM:To evaluate the correlation between axial lengths and anterior segment parameters using swept-source optical coherence tomography(SS-OCT).METHODS:For the cross-sectional clinical study, a total of 109 adult volunteers with different degrees of myopia recruited from January 1, 2022, to March 31, 2022, at the ophthalmology clinic of the First Affiliated Hospital of Zhengzhou University were included. Participants were divided into 4 groups based on axial length(AL): group A(AL≤24.0mm), group B(24.0mm

Result Analysis
Print
Save
E-mail