1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Analysis of physical fitness test results for freshmen with different nutritional status at Civil Aviation University of China from 2014 to 2024
SHEN Shunfa, PENG Ziye, CHEN Xuedong, LI Huichao, ZHAO Kun, PEI Zhengcun
Chinese Journal of School Health 2025;46(6):857-862
Objective:
To analyze the status and trends of physical fitness test data among college freshmen with different body mass index (BMI) groups from 2014 to 2024, providing the scientific evidence for monitoring and intervening in college students physical health.
Methods:
A census was conducted on all 67 949 freshmen at Civil Aviation University of China from 2014 to 2024. Physical tests included vital capacity, sit and reach, sit ups, 50 m sprint, standing long jump, pull ups, and 800 m/1 000 m run. Freshmen were divided into underweight, normal weight, overweight and obese groups according to WHO BMI standards. The Kruskal-Wallis H test was used to compare differences in physical fitness indicators across gender and BMI groups, while the Mann-Kendall trend test was employed to detect upward or downward trends in physical indicators over time.
Results:
From 2014 to 2024, statistically significant differences were observed in vital capacity, 50 m sprint, standing long jump, and sit and reach among different BMI groups for both genders (boy: Z =2 396.40, 4 160.33, 4 662.23, 531.85; girl: Z =593.37, 308.86, 499.37, 128.70). Significant differences were also found in 1 000 m run and pull ups for boys, and 800 m run and sit ups for girls across BMI groups (boy: Z =6 574.80, 6 880.48; girl: Z =528.56, 146.18) ( P <0.01). Overall physical test scores showed a declining trend during 2014-2024, particularly pronounced in overweight and obese groups. Male vital capacity in 2014 exceeded national survey data( d =320 mL), with the gap widening to 734 mL by 2019, while the female vital capacity difference increased from 271 mL in 2014 to 576 mL in 2019. Male 1 000 m run times were 23.0 s and 17.5 s faster than national data in 2014 and 2019 respectively, while female 800 m run times were 22.3 s and 21.5 s faster than corresponding national data.
Conclusions
Physical health status among freshmen at this university varies across BMI groups and changes over time. Although overall test scores remain higher than national levels, the declining trend in physical fitness performance requires attention.
7.Prevalence trends of elevated blood pressure and its association with nutritional status among primary and secondary school students in Inner Mongolia
Chinese Journal of School Health 2025;46(9):1342-1345
Objective:
To analyze the prevalence trends of different types of elevated blood pressure and their association with nutritional status among primary and secondary school students in Inner Mongolia from 2019 to 2024, providing references for targeted prevention strategies.
Methods:
From September 2019 to 2024, a stratified random cluster sampling method was used to select 12 primary and secondary schools from each league city in Inner Mongolia Autonomous Region. A total of 177 108, 137 758, 190 182, 180 084 , 188 056, 180 351 primary and secondary school students (excluding grades one to three of primary school) were included for physical examination. The correlation between their nutritional status and high blood pressure was analyzed based on the basic situation of 129 821 primary and secondary school students who completed a questionnaire survey at the same time in 2024. Statistical analysis was conducted using a Chi-square test and multiple Logistic regression model.
Results:
From 2019 to 2024, the detection rates of elevated blood pressure were 13.60%, 13.68%, 17.60%, 17.24%, 14.77% and 15.96%, respectively. The rates for isolated systolic hypertension were 4.24%, 5.83%, 7.26%, 7.19%, 6.24% and 6.93%; isolated diastolic hypertension rates were 6.38%, 4.99%, 6.23 %, 6.41%, 5.39% and 5.66%; and combined systolic and diastolic hypertension rates were 2.97%, 2.86%, 4.11%, 3.65%, 3.14 % and 3.36%. Multivariate Logistic regression analysis showed that girls, junior high school, senior high school, overweight, and obesity were positively associated with elevated blood pressure risk ( OR =1.27, 1.25, 1.32, 1.66, 3.07, all P <0.05); conversely, county residence, Mongolian ethnicity, and other ethnicities showed negative associations ( OR =0.90, 0.93, 0.90, all P <0.05).
Conclusions
Overweight and obesity among children and adolescents are closely related to various types of elevated blood pressure. Prevention strategies should prioritize effectively controlling weight issues among children and adolescents, thereby effectively reducing the incidence of elevated blood pressure.
8.Chemical Constituents and Pharmacological Effect of Epimedium sagittatum: A Review
Lixin PEI ; Lin CHEN ; Nuo LI ; Mengyao ZHAO ; Haoyuan YANG ; Xiaoyu YANG ; Baoyu JI
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(21):282-290
Epimedium sagittatum is a perennial herb of Berberidaceae. Its leaves have a long history of medicinal use in China. This plant is widely used as a Chinese traditional medicine,with the main functions of tonifying kidney Yang,strengthening bones and muscles,and dispelling wind and dampness. It can be used for treating kidney Yang deficiency,impotence,spermatorrhea,flaccidity of bones and muscles,rheumatic arthralgia,numbness,and spasms. The chemical constituents of this plant include flavonoids,polysaccharides,lignans,and alkaloids. Flavonoids are the main active ingredients. These compounds show a wide range of biological activities,including cartilage repair,anti-aging,anti-fatigue,cough-relieving,blood glucose-lowering,and anti-tumor effects. Modern pharmacological research has shown that E. sagittatum has definite pharmacological effects on the reproductive system,respiratory system,nervous system,cardiovascular system,skeletal system,etc. It has remarkable effects of helping pregnancy,resisting osteoporosis,controlling diabetes,improving immunity,and inhibiting tumor. Under the background of advocating one health and Chinese medicine,E. sagittatum is widely used in health care products,serving as the main raw material of various products. It has great market potential and is a Chinese medicinal herb with great clinical application and research value. This paper reviews the main chemical constituents and pharmacological effects of E. sagittatum based on domestic and foreign reports, providing a theoretical basis for further study on E. sagittatum and its safe clinical application.
9.Chemical Constituents and Pharmacological Effect of Epimedium sagittatum: A Review
Lixin PEI ; Lin CHEN ; Nuo LI ; Mengyao ZHAO ; Haoyuan YANG ; Xiaoyu YANG ; Baoyu JI
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(21):282-290
Epimedium sagittatum is a perennial herb of Berberidaceae. Its leaves have a long history of medicinal use in China. This plant is widely used as a Chinese traditional medicine,with the main functions of tonifying kidney Yang,strengthening bones and muscles,and dispelling wind and dampness. It can be used for treating kidney Yang deficiency,impotence,spermatorrhea,flaccidity of bones and muscles,rheumatic arthralgia,numbness,and spasms. The chemical constituents of this plant include flavonoids,polysaccharides,lignans,and alkaloids. Flavonoids are the main active ingredients. These compounds show a wide range of biological activities,including cartilage repair,anti-aging,anti-fatigue,cough-relieving,blood glucose-lowering,and anti-tumor effects. Modern pharmacological research has shown that E. sagittatum has definite pharmacological effects on the reproductive system,respiratory system,nervous system,cardiovascular system,skeletal system,etc. It has remarkable effects of helping pregnancy,resisting osteoporosis,controlling diabetes,improving immunity,and inhibiting tumor. Under the background of advocating one health and Chinese medicine,E. sagittatum is widely used in health care products,serving as the main raw material of various products. It has great market potential and is a Chinese medicinal herb with great clinical application and research value. This paper reviews the main chemical constituents and pharmacological effects of E. sagittatum based on domestic and foreign reports, providing a theoretical basis for further study on E. sagittatum and its safe clinical application.
10.A novel intracoronary hypothermia device reduces myocardial reperfusion injury in pigs
Zhiqiang PEI ; Jin QIU ; Yongchao ZHAO ; Shuai SONG ; Rui WANG ; Wei LUO ; Xingxing CAI ; Bin LIU ; Han CHEN ; Jiasheng YIN ; Xinyu WENG ; Yizhe WU ; Chenguang LI ; Li SHEN ; Junbo GE
Chinese Medical Journal 2024;137(20):2461-2472
Background::Hypothermia therapy has been suggested to attenuate myocardial necrosis; however, the clinical implementation as a valid therapeutic strategy has failed, and new approaches are needed to translate into clinical applications. This study aimed to assess the feasibility, safety, and efficacy of a novel selective intracoronary hypothermia (SICH) device in mitigating myocardial reperfusion injury.Methods::This study comprised two phases. The first phase of the SICH was performed in a normal porcine model for 30 minutes ( n = 5) to evaluate its feasibility. The second phase was conducted in a porcine myocardial infarction (MI) model of myocardial ischemia/reperfusion which was performed by balloon occlusion of the left anterior descending coronary artery for 60 minutes and maintained for 42 days. Pigs in the hypothermia group ( n = 8) received hypothermia intervention onset reperfusion for 30 minutes and controls ( n = 8) received no intervention. All animals were followed for 42 days. Cardiac magnetic resonance analysis (five and 42 days post-MI) and a series of biomarkers/histological studies were performed. Results::The average time to lower temperatures to a steady state was 4.8 ± 0.8 s. SICH had no impact on blood pressure or heart rate and was safely performed without complications by using a 3.9 F catheter. Interleukin-6 (IL-6), tumor necrosis factor-α, C-reactive protein (CRP), and brain natriuretic peptide (BNP) were lower at 60 min post perfusion in pigs that underwent SICH as compared with the control group. On day 5 post MI/R, edema, intramyocardial hemorrhage, and microvascular obstruction were reduced in the hypothermia group. On day 42 post MI/R, the infarct size, IL-6, CRP, BNP, and matrix metalloproteinase-9 were reduced, and the ejection fraction was improved in pigs that underwent SICH.Conclusions::The SICH device safely and effectively reduced the infarct size and improved heart function in a pig model of MI/R. These beneficial effects indicate the clinical potential of SICH for treatment of myocardial reperfusion injury.


Result Analysis
Print
Save
E-mail