1.Ectopic expression of hemoglobin subunits enhances the in vitro cytotoxicity of CAR-T cells against tumor cells under hypoxic conditions
YANG Jianxun1,2 ; ZHENG Rui3 ; LIANG Sixin3 ; PAN Jie4 ; LI Yanlong5 ; ZHAI Chenxi5 ; ZHAO Xiaojuan2 ; WANG Pengju3 ; DONG Hao4 ; YAN Bo2 ; SUN Zhihong1 ; YANG Angang3
Chinese Journal of Cancer Biotherapy 2026;33(3):233-242
[摘 要] 目的:探讨异位表达血红蛋白亚基(HBA/HBB)对缺氧条件下嵌合抗原受体T细胞(CAR-T细胞)功能障碍的改善作用及其对肿瘤细胞的杀伤效应。方法:全基因合成技术合成靶向HER2的CAR序列,构建共表达HBA或HBB的CAR慢病毒载体,包装慢病毒后感染人原代T淋巴细胞,制备异位表达HBA/HBB的CAR-T细胞,命名为HBA CAR-T和HBB CAR-T。采用缺氧探针检测小鼠实体瘤缺氧状态。通过流式细胞术检测瘤内CAR-T细胞占比、异位表达血红蛋白亚基的CAR-T细胞阳性率及CAR-T细胞的活性氧、凋亡水平。WB法检测HBA CAR-T和HBB CAR-T内相关血红蛋白亚基表达情况,采用细胞计数板计数检测细胞增殖水平,通过萤光素酶报告基因法检测CAR-T细胞对肿瘤细胞的杀伤能力,qPCR检测CAR-T细胞中缺氧诱导因子-1α(HIF-1α)表达水平,利用MitoXpress Intra试剂盒检测CAR-T细胞内氧气含量。结果:不同细胞构建的实体瘤模型均存在明显缺氧情况,且CAR-T细胞浸润水平与缺氧程度呈显著负相关(P < 0.000 1)。HBA CAR-T与HBB CAR-T构建成功(阳性率 > 60%),相应血红蛋白亚基可稳定表达。缺氧环境下HBA CAR-T和HBB CAR-T的ROS水平、凋亡水平显著下降,增殖、对肿瘤细胞的体外杀伤能力显著强于传统CAR-T细胞(均P < 0.05)。HBA CAR-T与HBB CAR-T内HIF-1α表达降低(均P < 0.001),且缺氧程度显著降低(均P < 0.001)。结论:异位表达血红蛋白亚基可改善缺氧条件下CAR-T细胞功能障碍并增强其对肿瘤细胞的体外杀伤作用。
2. Exploration and Practice of a Generative AI-assisted Four-dimensional Integration Platform of “Teaching, Learning, Evaluation, and Research” for The Biochemistry and Molecular Biology Courses
Pan CHEN ; Yang XI ; Xiao-Feng JIN ; De-Sen SUN ; Qiang CHEN ; Jun-Ming GUO
Progress in Biochemistry and Biophysics 2026;53(3):789-800
ObjectiveBiochemistry and Molecular Biology, a discipline that elucidates life phenomena at the molecular level, serves as a core foundational course in medical education. It provides the theoretical basis for studying other basic and clinical medical subjects, as well as for understanding pathogenesis, disease diagnosis, and treatment. However, its complex content and highly abstract concepts have posed a dual challenge to traditional teaching models: “inefficient instruction” and “inadequate learning outcomes”. Within limited classroom hours, how to engage students and stimulate their intrinsic motivation, and how to help them recognize, understand, and develop a passion for biochemistry from the perspective of the discipline’s essence, have long been key focuses of curriculum research. MethodsUsing the lipid metabolism chapter as an example, this study employs “Rain Classroom”, a generative artificial intelligence (AI)-assisted platform, to support education in four dimensions: teaching, learning, evaluation, and research. In teaching, it assists instructors through virtual experiments, lesson preparation support, knowledge mapping, and assignment design. For learning, it serves as an intelligent study assistant for students, providing automated assignment review, enabling educational resource sharing, and facilitating personalized learning pathways. In evaluation, the platform automates assignment grading, analyzes student performance data, and offers diagnostic feedback and teaching recommendations. In research, it aids educators in collecting and analyzing teaching data, as well as searching for and summarizing relevant literature. ResultsThe results indicate that an educational model integrating teacher-led instruction, student-centered learning, and generative AI assistance significantly enhances teaching quality, students’ self-directed learning abilities, and knowledge mastery. Furthermore, with the support of generative AI, curriculum-based ideological education—focusing on cutting-edge disciplinary advances and topical medical issues—helps cultivate students’ medical spirit of “honoring life and healing the wounded”, thereby fostering the establishment of appropriate professional values. Finally, while generative AI presents both opportunities and challenges for higher education, this study also analyzes potential risks in its teaching applications, emphasizing the need for both instructors and students to avoid over-reliance and to ensure that technological tools consistently serve the fundamental goals of education. ConclusionThis study demonstrates that integrating generative AI, specifically via the “Rain Classroom” platform, can effectively enhance biochemistry education. By supporting teaching, learning, evaluation, and research, this approach improves both educational effectiveness and student outcomes. It also facilitates the incorporation of cutting-edge knowledge and professional ethics, nurturing a patient-centered mindset. Additionally, the study addresses potential implementation risks to ensure that such technological tools remain aligned with the core purpose of education.
3.Preliminary evaluation of the safety and efficacy of a self-prepared activated prothrombin complex concentrate
Xu PAN ; Yuwei HUANG ; Liehuo MAO ; Pan SUN ; Changqing LI ; Xi DU ; Li MA
Chinese Journal of Blood Transfusion 2026;39(8):1004-1011
Objective: To evaluate the in vitro procoagulant efficacy and in vivo potential thrombogenic risk of self-prepared activated prothrombin complex concentrate (aPCC). Methods: The preparation was administered at a dose of 0.5 IU per milliliter of plasma. For in vitro assays, the self-prepared aPCC concentrate was added to plasma spiked with factorⅧ (FⅧ) inhibitors. Calibrated automated thrombin generation (CAT), prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), and fibrinogen (Fib) quantification were performed. Normal saline and FEIBA
were set as controls to evaluate the procoagulant capacity of the self-prepared aPCC concentrate. For in vivo animal studies, the self-prepared aPCC concentrate was injected into rats via the jugular vein. A ferric chloride (FeCl3) filter paper patch was applied to induce carotid arterial thrombosis. Laser speckle blood flow imaging was used to continuously monitor thrombus formation in the rat carotid artery. Plasma samples were collected from rats for CAT, PT, APTT, TT and Fib testing, with normal saline and FEIBA
as controls to evaluate the potential thrombogenic risk of the self-prepared aPCC concentrate. Results: Supplementation with aPCC significantly shortened APTT and PT values in inhibitor-spiked plasma (all P<0.001). There were no statistically significant differences in APTT and PT between FEIBA
and self-prepared aPCC (P>0.05). CAT results demonstrated that adding aPCC to inhibitor-containing plasma markedly increased endoge-nous thrombin potential (ETP) and peak thrombin concentration (Peak) (P<0.001), with both parameters higher than those of normal plasma (P<0.05). No significant intergroup difference in ETP was observed between self-prepared aPCC and FEIBA
(P>0.05). Carotid blood flow imaging in rats revealed that, compared with FEIBA
, thrombi induced by self-prepared aPCC were smaller and less stable, and all underwent spontaneous lysis, accompanied by better restoration of carotid blood perfusion. Conclusion: The self-prepared aPCC restores coagulation function in inhibitor-spiked plasma to a comparable extent as FEIBA
, while exhibiting a lower thrombogenic risk.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Best essential surgical technique training course to improve surgical residents′ laparoscopic peritoneal suturing skills: a cohort study
Zhenghao CAI ; Haiqin SONG ; Jing SUN ; Pei XUE ; Luyang ZHANG ; Chao WU ; Hiju HONG ; Xi CHENG ; Sen ZHANG ; Minhua ZHENG ; Lu ZANG ; Ruijun PAN ; Jianwen LI ; Bo FENG
Journal of Surgery Concepts & Practice 2025;30(2):132-137
Objective To explore the effectiveness of an integrated laparoscopic simulation training course (best essential surgical technique training, BEST) in enhancing laparoscopic peritoneal suturing techniques in surgical residents.Methods As an integrated two-stage program, the BEST course applied basic laparoscopic training system with simple molds in phase Ⅰ training, and then adopted advanced laparoscopic training system, 3D Laparoscope and ex-vivo animal models in phase Ⅱ training. The laparoscopic suturing techniques were practiced in phase Ⅱ training. From August 2021 to July 2024, surgical residents in the second year of the national standardized training program were divided into pilot and control groups based on whether they had undergone the BEST course. Two cases of laparoscopic peritoneal suture were performed by the surgical residents under supervision in the department of gastrointestinal surgery. The operative time, quality of suture, and independent completion rate were compared between the two groups.Results A total of 33 surgical residents (19 in pilot group and 14 in control group) were included in this study, and a total of 66 cases of laparoscopic peritoneal suture were performed (38 in pilot group and 28 in control group). The operative time was significantly shorter in pilot group than that in control group (15.7 min vs. 17.5 min, P=0.025). The quality of suture was significantly better in pilot group compared to control group (P=0.023). In pilot group, all peritoneal sutures were performed by residents independently, whereas in control group, 3 cases (10.7%) were assisted by the supervisor, and the independent completion rate was different significantly (P=0.039).Conclusions The BEST course can help improve surgical residents′ laparoscopic peritoneal suturing techniques and could be promoted in the national standardized training program for surgical residents.
8.Association between unhealthy lifestyle and risk of heart disease and diabetes in the elderly in Xi'an
Ning CUI ; Jun LIU ; Rui WANG ; Nini MA ; Man ZHANG ; Aiping SUN ; Xiaomin RAN ; Aiqing PAN
Journal of Public Health and Preventive Medicine 2025;36(5):163-167
Objective To investigate the association between lifestyle and risk of heart disease and diabetes in the elderly population in Xi'an City. Methods From January 2021 to January 2024, a staged cluster sampling method was used to investigate the lifestyle and the occurrence of heart disease and diabetes in elderly population aged 60 years and above in the communities of Xi'an. Multivariate logistic regression was used to analyze the relationship between lifestyle and the risk of heart disease and diabetes. Results A total of 413 elderly people were investigated, of which 31.96% had heart disease, 27.12% had diabetes, and 10.90% had diabetes with heart disease. Multivariate logistic regression analysis revealed that age, BMI, family history, sweet food preference, smoking, and sitting and lying for a long time were risk factors for diabetes in the elderly population (P<0.05). Age, BMI, family history, history of diabetes, preference for salted products, smoking, drinking, and sitting and lying for a long time were risk factors for heart disease in the elderly population (P<0.05). Conclusion The incidence rates of heart disease and diabetes are high in the elderly population in Xi'an City. The risk of diabetes is related to unhealthy lifestyles such as sweet food preference, smoking, and sitting and lying for a long time, while heart disease is related to unhealthy lifestyles such as preference for salted products, smoking, drinking, and sitting and lying for a long time.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.


Result Analysis
Print
Save
E-mail