1.Effect of various intracanal materials on the diagnostic accuracy of cone-beam computed tomography in vertical root fractures.
Jin Hua ZHANG ; Jie PAN ; Zhi Peng SUN ; Xiao WANG
Journal of Peking University(Health Sciences) 2023;55(2):333-338
OBJECTIVE:
To study the effect of various intracanal materials on the accuracy of oral maxillofacial cone-beam computed tomography (CBCT) for the diagnosis of vertical root fracture (VRF).
METHODS:
A total of twenty-four structurally intact single root canal dried and isolated teeth extracted for orthodontic treatment or periodontal disease were collected. The teeth were decrowned along the cemento-enamel junction (CEJ) and then used as samples for the study after conventional root canal preparation and post preparation. The 24 samples were divided into two groups with 12 samples in each group. Group A was the control group (no VRF group). According to intracanal materials, they were divided into five subgroups: blank group, fiber post group, gutta-percha point group, titanium post group and gold-palladium post group. Group B was the experimental group (VRF group), and subgroups were grouped as above. The VRF model was prepared by a unified method in the VRF group: the root was completely fractured in the buccolingual direction with a custom root canal nail and then cemented and reset. The control group was not subjected to the simulation of VRF. Titanium post and gold-palladium post were made according to the individuality of the root canal preparation, and the tightness of the post to the root canal wall was confirmed by X-ray radiograph. Then all the samples were scanned by CBCT in the isolate swine mandibular alveolar sockets. The diagnostic accuracy was statistically analyzed via blind interpretation by experienced endodontic specialists and oral and maxillofacial medical imaging specialists.
RESULTS:
The accuracy of the diagnosis of VRF in the blank group, fiber post group, gutta-percha point group, titanium post group, and gold-palladium post group in CBCT was 95.83%, 91.67%, 87.50%, 79.17%, and 45.83%, respectively. Compared with the blank group, the differences were not statistically significant in the fiber post group (P>0.999), the gutta-percha point group (P=0.500) and the titanium post group (P=0.125). The lowest diagnostic accuracy of VRF was found in the gold-palladium post group, and the difference was statistically significant compared with all other groups (P < 0.001).
CONCLUSION
Various intracanal materials have different degrees of influence on the diagnostic accuracy of VRF diagnosis in CBCT. The influence of fiber post, gutta-percha point and titanium post was small, while the influence of gold-palladium post was significant.
Animals
;
Cone-Beam Computed Tomography/methods*
;
Gold
;
Gutta-Percha
;
Palladium
;
Swine
;
Titanium
;
Tooth Fractures/diagnostic imaging*
;
Tooth Root/injuries*
;
Reproducibility of Results
2.Antifungal effect of electrolyzed hydrogen water on Candida albicans biofilm.
Kyung Ryul PYO ; Yun Seung YOO ; Dong Heon BAEK
Journal of Dental Rehabilitation and Applied Science 2015;31(3):212-220
PURPOSE: Candida albicans can cause mucosal disease in many vulnerable patients. Also they are associated with denture-related stomatitis. Electrolyzed water is generated by electric current passed via water using various metal electrodes and has antimicrobial activity. The aim of this study was to investigate antifungal activity of electrolyzed water on C. albicans biofilm. MATERIALS AND METHODS: C. albicans was cultured by sabouraud dextrose broth and F-12 nutrient medium in aerobic and 5% CO2 condition to form blastoconidia (yeast) and hyphae type, respectively. For formation of C. albicans biofilm, C. albicans was cultivated on rough surface 6-well plate by using F-12 nutrient medium in CO2 incubator for 48 hr. After electrolyzing tap water using various metal electrodes, the blastoconidia and hyphal type of C. albicans were treated with electrolyzed water. C. albicans formed blastoconidia and hyphae type when they were cultured by sabouraud dextrose broth and F-12 nutrient medium, respectively. RESULTS: The electrolyzed water using palladium electrode (EWP) exhibited antifungal effect on blastoconidia of C. albicans. Also, the EWP significantly has antifungal activity against C. albicans biofilm and hyphae. In the electrolyzed water using various metal electrodes, only the EWP have antifungal activity. CONCLUSION: The EWP may use a gargle solution and a soaking solution for prevention of oral candidiasis and denture-related stomatitis due to antifungal activity. (
Biofilms*
;
Candida albicans*
;
Candida*
;
Candidiasis, Oral
;
Electrodes
;
Glucose
;
Humans
;
Hydrogen*
;
Hyphae
;
Incubators
;
Palladium
;
Stomatitis
;
Water*
3.Patch Testing with Dental Screening Series in Oral Disease.
Tae Wook KIM ; Woo Il KIM ; Je Ho MUN ; Margaret SONG ; Hoon Soo KIM ; Byung Soo KIM ; Moon Bum KIM ; Hyun Chang KO
Annals of Dermatology 2015;27(4):389-393
BACKGROUND: The oral mucosa is constantly exposed to several irritants and allergens including dental materials, but the role of contact allergy in oral disease is obscure. OBJECTIVE: To analyze positive patch test results in patients with oral diseases and evaluate the clinical relevance of oral diseases with contact allergy to dental materials. METHODS: We retrospectively analyzed patch test results with dental screening series in 44 patients with oral disease from 2004~2011. RESULTS: Oral diseases included oral lichen planus (54.5%), cheilitis (27.3%), burning mouth syndrome (9.1%), and others (9.1%). Thirty-one of 44 patients (70.5%) had positive reactions to one or more allergens. The most commonly detected allergens were gold sodium thiosulfate (25.0%) and nickel sulfate (25.0%), followed by potassium dichromate (22.7%), cobalt (15.9%), palladium (6.8%), mercury (4.5%), copper (4.5%), and methylhydroquinone (4.5%). Six of 24 patients with oral lichen planus had a symptom in areas adjacent to dental materials and positive patch test reactions to allergens contained in the suspected dental materials. CONCLUSION: Patch tests with dental screening series are worth considering for oral diseases, especially for oral lichen planus.
Allergens
;
Burning Mouth Syndrome
;
Cheilitis
;
Cobalt
;
Copper
;
Dental Materials
;
Gold Sodium Thiosulfate
;
Humans
;
Hypersensitivity
;
Irritants
;
Lichen Planus, Oral
;
Mass Screening*
;
Mouth Mucosa
;
Nickel
;
Palladium
;
Patch Tests*
;
Potassium Dichromate
;
Retrospective Studies
4.Influence of shape and finishing on the corrosion of palladium-based dental alloys.
Ana MILHEIRO ; Joris MURIS ; Cornelis J KLEVERLAAN ; Albert J FEILZER
The Journal of Advanced Prosthodontics 2015;7(1):56-61
PURPOSE: The purpose of this study was to evaluate the effects of the surface treatment and shape of the dental alloy on the composition of the prosthetic work and its metallic ion release in a corrosive medium after casting. MATERIALS AND METHODS: Orion Argos (Pd-Ag) and Orion Vesta (Pd-Cu) were used to cast two crowns and two disks. One of each was polished while the other was not. Two as-received alloys were also studied making a total of 5 specimens per alloy type. The specimens were submersed for 7 days in a lactic acid/sodium chloride solution (ISO standard 10271) and evaluated for surface structure characterization using SEM/EDAX. The solutions were quantitatively analysed for the presence of metal ions using ICP-MS and the results were statistically analysed with one-way ANOVA and a Tukey post-hoc test. RESULTS: Palladium is released from all specimens studied (range 0.06-7.08 microg.cm(-2).week(-1)), with the Pd-Cu alloy releasing the highest amounts. For both types of alloys, ion release of both disk and crown pairs were statistically different from the as-received alloy except for the Pd-Ag polished crown (P>.05). For both alloy type, disk-shaped pairs and unpolished specimens released the highest amounts of Pd ions (range 0.34-7.08 microg.cm(-2).week(-1)). Interestingly, in solutions submerged with cast alloys trace amounts of unexpected elements were measured. CONCLUSION: Shape and surface treatment influence ion release from dental alloys; polishing is a determinant factor. The release rate of cast and polished Pd alloys is between 0.06-0.69 microg.cm(-2).week(-1), which is close to or exceeding the EU Nickel Directive 94/27/EC compensated for the molecular mass of Pd (0.4 microg.cm(-2).week(-1)). The composition of the alloy does not represent the element release, therefore we recommend manufacturers to report element release after ISO standard corrosion tests beside the original composition.
Alloys
;
Corrosion*
;
Crowns
;
Dental Alloys*
;
Ions
;
Nickel
;
Palladium
5.Influence of cryogenic treatment and age-hardening heat treatment on the corrosion behavior of a dental casting Ag-Pd alloy.
Yao ZHAO ; Bin WU ; Yukun MENG
West China Journal of Stomatology 2014;32(3):238-241
OBJECTIVEThe purpose of this study is to investigate the influence of cryogenic treatment and age-hardening heat treatment on the corrosion behavior of a dental casting Ag-Pd alloy.
METHODSA low gold content dental casting alloy composed of Ag-Pd-Cu-Au was prepared for this study. Corrosion test was performed according to ISO 10271:2001 dental metallie-corrosion test methods. Experimental specimens were casted according to a standard dental lost-wax casting procedure, treated with solution by heating the specimens to 900 degrees C, and immediately quenched in ice water. The specimens were then divided into four groups and subjected to heat treatment, cryogenic treatment, and heat treatment combined with cryogenic treatment. The specimens after the solution treatment were taken as control. The metallographic structures of the specimens were observed. The electrochemical parameters and the quantity of non-precious metallic ions released were evaluated via electrochemical and static immersion tests.
RESULTSMetallographic observation revealed that all the treatments resulted in a change in the microstructure of the alloy. The treatments were effective in improving the electrochemical parameters, such as an increase in Eocp and Ecorr and a decrease in Icorr (P < 0.05). The amount of non-noble metal ions released showed no difference compared with the control group (P > 0.05).
CONCLUSIONAfter different treatments, the antierosion properties of the alloy satisfied the ISO requirements. Age-hardening heat treatment and cryogenic treatment improved the corrosion resistance of the alloy.
Alloys ; Copper ; Corrosion ; Dental Alloys ; Gold Alloys ; Hot Temperature ; Palladium ; Silver
6.Influence of cryogenic treatment and age-hardening heat treatment on the microhardness of palladium-silver dental alloys.
Yao ZHAO ; Xu TONG ; Jiajun LIU ; Zhichao HAO ; Yukun MENG
West China Journal of Stomatology 2013;31(3):235-241
OBJECTIVEThe purpose of this study was to investigate the influence of cryogenic treatment and age-hardening heat treatment on the micro-Vicker's hardness of palladium-silver dental alloys.
METHODSA low-gold content dental casting alloy composed of Ag-Pd-Cu-Au was prepared for this study. Experimental specimens according to standard requirements were prepared following a standard dental laboratory casting procedure, cast specimens were heated to 900 degrees C and quenched in ice water. The specimens were then divided into 4 groups. They were subsequently subjected to different treatments, including age-hardening heat treatment, cryogenic treatment, heat treatment combined with cryogenic treatment. The non-treated group was used as control. The micro-Vicker's hardness value was examined. The significance of correlation was analyzed.
RESULTSThe micro-Vicker's hardness of specimens after age-hardening heat treatment, cryogenic treatment, heat treatment combined with cryogenic treatment increased by 129%, 13% and 141%, respectively, compared with that of the non-treated control group. Conclusion Age-hardening heat treatment and cryogenic treatment were effective in elevating the hardness of Ag-Pd-Cu-Au alloy.
Copper ; Dental Alloys ; Gold Alloys ; Hardness ; Hot Temperature ; Humans ; Palladium ; Silver
7.Development and Evaluation of the Quick Anaero-system-A New Disposable Anaerobic Culture System.
Nam Woong YANG ; Jin Man KIM ; Gwang Ju CHOI ; Sook Jin JANG
The Korean Journal of Laboratory Medicine 2010;30(2):133-137
BACKGROUND: We developed a new disposable anaerobic culture system, namely, the Quick anaero-system, for easy culturing of obligate anaerobes. METHODS: Our system consists of 3 components: 1) new disposable anaerobic gas pack, 2) disposable culture-envelope and sealer, and 3) reusable stainless plate rack with mesh containing 10 g of palladium catalyst pellets. To evaluate the efficiency of our system, we used 12 anaerobic bacteria. We prepared 2 sets of ten-fold serial dilutions of the 12 anaerobes, and inoculated these samples on Luria-Bertani (LB) broth and LB blood agar plate (LB-BAP) (BD Diagnostic Systems, USA). Each set was incubated in the Quick anaero-system (DAS Tech, Korea) and BBL GasPak jar with BD GasPak EZ Anaerobe Container System (BD Diagnostic Systems) at 35-37degrees C for 48 hr. The minimal inoculum size showing visible growth of 12 anaerobes when incubated in both the systems was compared. RESULTS: The minimal inoculum size showing visible growth for 2 out of the 12 anaerobes in the LB broth and 9 out of the 12 anaerobes on LB-BAP was lower for the Quick anaero-system than in the BD GasPak EZ Anaerobe Container System. The mean time (+/-SD) required to achieve absolute anaerobic conditions of the Quick anaero-system was 17 min and 56 sec (+/-3 min and 25 sec). CONCLUSIONS: The Quick anaero-system is a simple and effective method of culturing obligate anaerobes, and its performance is superior to that of the BD GasPak EZ Anaerobe Container System.
Bacteria, Anaerobic/*growth &development
;
Bacteriological Techniques/instrumentation/methods
;
Culture Media/chemistry
;
Gases/chemistry
;
Palladium/chemistry
;
Reagent Kits, Diagnostic
8.Two Cases of Melanosis Ilei Developed after Long-standing Charcoal Ingestion.
Myung Suk KIM ; Yong Bum PARK ; Byeong Wha HA ; Dae Young CHEUNG ; Jin Il KIM ; Se Hyun CHO ; Soo Heon PARK ; Jae Kwang KIM
Korean Journal of Gastrointestinal Endoscopy 2008;36(1):36-39
Melanosis ilei is an extremely rare condition in which black pigment, consisted of aluminum, magnesium, or silicon, accumulate in the terminal ileal mucosa. Medical treatment with charcoal enhances the neutralization of the toxic material and elimination of many drugs. In addition, it has been used as a traditional remedy in some oriental countries to relieve chronic diarrhea, abdominal pain, or acute enterocolitis, which is made up carbon, oxygen, aluminum, magnesium, silicon, calcium, and palladium. Two patients taking the charcoal for a long time underwent a colonoscopy to evaluate chronic diarrhea or abdominal pain. The colonoscopy revealed a normal colonic mucosa and multiple geographic black-pigmented mucosal changes at the terminal ileum. Therefore, it was assumed that melanosis ilei can develop in patients with long-standing charcoal ingestion. To the best of our knowledge, this is the first case of melanosis ilei associated with the ingestion of charcoal.
Abdominal Pain
;
Aluminum
;
Calcium
;
Carbon
;
Charcoal
;
Colon
;
Colonoscopy
;
Diarrhea
;
Eating
;
Enterocolitis
;
Humans
;
Ileum
;
Magnesium
;
Melanosis
;
Mucous Membrane
;
Oxygen
;
Palladium
9.Induction of biliary cholangiocarcinoma cell apoptosis by 103Pd cholangial radioactive stent gamma-rays.
Gui-jin HE ; Dan-dan SUN ; Da-wei JI ; Dong-ming SUI ; Fa-qiang YU ; Qin-yi GAO ; Xian-wei DAI ; Hong GAO ; Tao JIANG ; Chao-liu DAI
Chinese Medical Journal 2008;121(11):1020-1024
BACKGROUNDIn recent years, interventional tumor therapy, involving implantation of intra-cholangial metal stents through percutaneous trans-hepatic punctures, has provided a new method for treating cholangiocarcinoma. (103)Pd cholangial radioactive stents can concentrate high radioactive dosages into the malignant tumors and kill tumor cells effectively, in order to prevent re-stenosis of the lumen caused by a relapsed tumor. The aim of the present study was to investigate the efficacy of gamma-rays released by the (103)Pd biliary duct radioactive stent in treating cholangiocarcinoma via induction of biliary cholangiocarcinoma cell apoptosis.
METHODSA group of biliary duct cancer cells was collectively treated with a dose of gamma-rays. Cells were then examined by the 3-(4, 5-dimethyl thiazol-2-yl)-2, 5-diphenyl terazolium-bromide (MTT) technique for determining the inhibition rate of the biliary duct cancer cells, as well as with other methods including electron microscopy, DNA agarose gel electrophoresis, and flow cytometry were applied for the evaluation of their morphological and biochemical characteristics. The growth curve and the growth inhibition rate of the cells were determined, and the changes in the ultrastructure of the cholangiocarcinoma cells and the DNA electrophoresis bands were examined under a UV-lamp.
RESULTSThe gamma-ray released by (103)Pd inhibited cholangiocarcinoma cell growth, as demonstrated when the growth rate of the cells was stunned by a gamma-ray with a dosage larger than 197.321 MBq. Typical features of cholangiocarcinoma cell apoptosis were observed in the 197.321 MBq dosage group, while cell necrosis was observed when irradiated by a dosage above 245.865 MBq. DNA agarose gel electrophoresis results were different between the 197.321 MBq irradiation dosage group, the 245.865 MBq irradiation dosage group, and the control group.
CONCLUSIONS(103)Pd radioactive stents which provide a radioactive dosage of 197.321 MBq are effective in the treatment of cholangiocarcinoma; (103)Pd radioactive stents should be useful for the clinical treatment of cholangiocarcinoma.
Apoptosis ; radiation effects ; Bile Duct Neoplasms ; pathology ; radiotherapy ; ultrastructure ; Bile Ducts, Intrahepatic ; Cell Line, Tumor ; Cell Proliferation ; radiation effects ; Cholangiocarcinoma ; pathology ; radiotherapy ; ultrastructure ; DNA ; analysis ; Flow Cytometry ; Gamma Rays ; therapeutic use ; Humans ; Palladium ; Stents
10.Structure relationship of nitrochlorobenzene catalytic degradation process in water over palladium-iron bimetallic catalyst.
Shao-feng NIU ; Hong-yi ZHOU ; Xu-ping AO ; Xin-hua XU ; Zhang-hua LOU
Journal of Zhejiang University. Science. B 2006;7(7):548-552
Two isomers of nitrochlorobenzene (o-, and p-NCB) were treated by a Pd/Fe catalyst in aqueous solutions through catalytic amination and dechlorination. Nitrochlorobenzenes are rapidly converted to form chloroanilines (CAN) first through an amination process, and then rapidly dechlorinated to become aniline (AN) and Cl(-), without the involvement of any other intermediate reaction products. The amination and dechlorination reaction are believed to take place predominantly on the surface site of the Pd/Fe catalysts. The dechlorination rate of the reductive degradation of the two isomers of nitrochlorobenzene (o-, and p-NCB) in the presence of Pd/Fe as a catalyst was measured experimentally. In all cases, the reaction rate constants were found to increase with the decrease in the Gibbs free energy (correlation with the activation energy) of NCBs formation; the activation energy of each dechlorination reaction was measured to be 95.83 and 77.05 kJ/mol, respectively for o- and p-NCB. The results demonstrated that p-NCBs were reduced more easily than o-NCBs.
Catalysis
;
Industrial Waste
;
prevention & control
;
Iron
;
chemistry
;
Isomerism
;
Kinetics
;
Metals
;
chemistry
;
Nitrobenzenes
;
chemistry
;
Palladium
;
chemistry
;
Structure-Activity Relationship
;
Waste Disposal, Fluid
;
methods
;
Water
;
chemistry
;
Water Purification
;
methods

Result Analysis
Print
Save
E-mail