1.Therapeutic Study on The Inhibition of Neuroinflammation in Ischemic Stroke by Induced Regulatory T Cells
Tian-Fang KANG ; Ai-Qing MA ; Li-Qi CHEN ; Han GONG ; Jia-Cheng OUYANG ; Fan PAN ; Hong PAN ; Lin-Tao CAI
Progress in Biochemistry and Biophysics 2025;52(4):946-956
ObjectiveNeuroinflammation plays a crucial role in both the onset and progression of ischemic stroke, exerting a significant impact on the recovery of the central nervous system. Excessive neuroinflammation can lead to secondary neuronal damage, further exacerbating brain injury and impairing functional recovery. As a result, effectively modulating and reducing neuroinflammation in the brain has become a key therapeutic strategy for improving outcomes in ischemic stroke patients. Among various approaches, targeting immune regulation to control inflammation has gained increasing attention. This study aims to investigate the role of in vitro induced regulatory T cells (Treg cells) in suppressing neuroinflammation after ischemic stroke, as well as their potential therapeutic effects. By exploring the mechanisms through which Tregs exert their immunomodulatory functions, this research is expected to provide new insights into stroke treatment strategies. MethodsNaive CD4+ T cells were isolated from mouse spleens using a negative selection method to ensure high purity, and then they were induced in vitro to differentiate into Treg cells by adding specific cytokines. The anti-inflammatory effects and therapeutic potential of Treg cells transplantation in a mouse model of ischemic stroke was evaluated. In the middle cerebral artery occlusion (MCAO) model, after Treg cells transplantation, their ability to successfully migrate to the infarcted brain region and their impact on neuroinflammation levels were examined. To further investigate the role of Treg cells in stroke recovery, the changes in cytokine expression and their effects on immune cell interactions was analyzed. Additionally, infarct size and behavioral scores were measured to assess the neuroprotective effects of Treg cells. By integrating multiple indicators, the comprehensive evaluation of potential benefits of Treg cells in the treatment of ischemic stroke was performed. ResultsTreg cells significantly regulated the expression levels of both pro-inflammatory and anti-inflammatory cytokines in vitro and in vivo, effectively balancing the immune response and suppressing excessive inflammation. Additionally, Treg cells inhibited the activation and activity of inflammatory cells, thereby reducing neuroinflammation. In the MCAO mouse model, Treg cells were observed to accumulate in the infarcted brain region, where they significantly reduced the infarct size, demonstrating their neuroprotective effects. Furthermore, Treg cell therapy notably improved behavioral scores, suggesting its role in promoting functional recovery, and increased the survival rate of ischemic stroke mice, highlighting its potential as a promising therapeutic strategy for stroke treatment. ConclusionIn vitro induced Treg cells can effectively suppress neuroinflammation caused by ischemic stroke, demonstrating promising clinical application potential. By regulating the balance between pro-inflammatory and anti-inflammatory cytokines, Treg cells can inhibit immune responses in the nervous system, thereby reducing neuronal damage. Additionally, they can modulate the immune microenvironment, suppress the activation of inflammatory cells, and promote tissue repair. The therapeutic effects of Treg cells also include enhancing post-stroke recovery, improving behavioral outcomes, and increasing the survival rate of ischemic stroke mice. With their ability to suppress neuroinflammation, Treg cell therapy provides a novel and effective strategy for the treatment of ischemic stroke, offering broad application prospects in clinical immunotherapy and regenerative medicine.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.A 30-year review and outlook on esophageal acid and pressure measurement
Yong JIANG ; Wentao FANG ; Zhigang LI ; Wenhu CHEN ; Wenhu PAN ; Yanfang ZHENG ; Hong ZHANG ; Yuchen SU ; Jie ZHANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(06):766-770
The Department of Thoracic Surgery of Shanghai Chest Hospital has performed esophageal function testing for over 30 years, being the only department of its kind in China with this capability. The pressure testing and 24-hour pH/impedance monitoring of the esophagus is of great help to assist in the diagnosis and treatment of benign and malignant esophageal diseases related to it. Thanks to the esophageal function test, in addition to the routine various endoscopic anti-reflux procedures, our hospital has taken the lead in China in recent years to carry out a series of clinical and research work for benign esophageal diseases, such as the development of magnetic ring, double nedoscopic combination and new anti-reflux endoscopic techniques. In recent years, we have carried out high-resolution esophageal manometry and 24-hour pH/impedance monitoring for patients with interstitial pneumonia and pulmonary fibrosis suspected to be caused by gastroesophageal acid reflux. We can better assess the correlation between gastroesophageal reflux and pulmonary fibrosis, and to provide the different clinical treatments and even surgical interventions. The Bravo capsule is used more often in the United States, and it has obvious advantages over traditional approach for acid measurement. We strongly call for the collaboration between industry and academic institutions in this field, and the development of our own related products with independent intellectual property rights.
8.A clinical study on the effectiveness of feedforward control mode on improving occupational burnout among operating room nurses
Ru GU ; Liyan ZHAO ; Qianru WANG ; Hong ZHANG ; Dan LEI ; Yang YAO ; Pan LIU ; Jinzhu SUN ; Na LI
Chinese Medical Ethics 2025;38(10):1373-1378
ObjectiveTo explore the effectiveness of feedforward control mode on improving occupational burnout among operating room nurses through theoretical research and clinical practice, with a view to promoting their physical and mental health and enhancing the quality of surgical nursing. MethodsA total of 440 operating room nurses from different regions, scales, and nursing experiences in Shaanxi Province from November 2023 to December 2023 were randomly divided into an experimental group and a control group, with 220 nurses in each group. While the control group received routine intervention measures, the experimental group introduced a feedforward control mode based on the control group, with “emotional exhaustion,” “depersonalization,”and“personal achievement” as observation indicators. ResultsThe incidence of occupational burnout in the experimental group was 11.4%, while that in the control group was 20.0%. The experimental group showed a significantly lower incidence than the control group (P=0.013). ConclusionThe feedforward control mode can significantly alleviate nurses’ sense of job burnout, promote the improvement of surgical nursing quality, as well as continuously improve the scientific rigor, advancement, and humanistic nature of nursing services, which is conducive to building a harmonious and efficient nursing team. The spirit of teamwork, reflected in mutual support, mutual trust, and joint efforts for surgical success and patient health, has become an important component of nurses’ professional ethics.
9.Effect of Hirudo on autophagy in atherosclerotic mice
Qian-Qian HAN ; Yun-Yun PAN ; Zi-Yun WEN ; Qing LÜ ; Liang WEI ; Meng-Yi LI ; Min HONG
The Chinese Journal of Clinical Pharmacology 2024;40(5):688-692
Objective To explore the anti-atherosclerosis mechanism of Hirudo and its effect on autophagy in mice.Methods Forty healthy male ApoE-/-mice were randomly divided into model group,control group(3 × 10-3 g·kg-1·d-1 simvastatin)and experimental-L,experimental-M,experimental-H groups(0.45,0.9,1.8 g·kg-1· d-1,Maixuekang capsule).Eight healthy male C57BL/6J mice were divided into blank group.The mice were fed with common diet for 1 week.Then,except blank group,other groups were fed with high-fat diet.After 8 weeks of modeling,the atherosclerosis(AS)mice were given drugs orally once a day for 12 weeks,and fed with high-fat diet in the meantime.The levels of interleukin-6(IL-6),tumor necrosis factor-α(TNF-α)in serum were determined by enzyme-linked immunosorbent assay(ELISA).The levels of Beclin-1,LC3 autophagy protein were detected by Western blot method.Results The IL-6 contents in the experimental-H,experimental-M,experimental-L,control,model and blank groups were(107.59±3.03),(99.31±5.12),(103.52±2.28),(98.68±4.68),(112.66±6.08),(93.98±3.43)pg·mL-1;the TNF-α contents were(538.41±30.26),(504.49±21.51),(538.51±19.05),(494.05±25.08),(578.53±26.32),(467.35±21.53)pg·mL-1.For the above indexes,the differences between model group and experimental-H group,experimental-M group,experimental-L group,control group,blank group were all statistically significant(all P<0.05).The Beclin-1 protein expression levels in the experimental-H,experimental-M,experimental-L,control and model groups were 1.48±0.05,1.72±0.05,1.19±0.02,1.51±0.04,0.66±0.03;the LC3 Ⅱ protein expression levels were 1.53±0.01,1.83±0.02,1.16±0.01,1.90±0.01,0.49±0.01,and the differences between model group and experimental-H group,experimental-M group,experimental-L group,control group were all statistically significant(all P<0.05).Conclusion Hirudo can significantly reduce the area of atherosclerotic plaque by regulating the level of autophagy.
10.Network Correlation Analysis Between Components of Shuanghuanglian Injection and Allergy-like Targets
Weilong ZHANG ; Hong HE ; Ru QIAO ; Peng HE ; Wenjiao LI ; Liangqi ZHANG ; Xiaoxuan LIU ; Siqi HUANG ; Xue PAN ; Fuyuan HE
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(19):190-197
ObjectiveBased on the network pharmacology system and quantitative spectroscopy of traditional Chinese medicine(TCM) compounds, a topological network analysis method with equilibrium constant as the core was established to further explore the interaction between allergenic components and their network targets in Shuanghuanglian injection(SHLI), in order to provide new ideas and experimental basis for identifying and screening potential allergens of SHLI. MethodAfter one week of adaptive feeding, 72 SPF-grade SD male rats were randomly divided into blank group, SHLI standard group, Lonicerae Japonicae Flos(LJF) group, Scutellariae Radix(SR) group, Forsythiae Fructus(FF) group, and 7 groups of SHLI matching groups(groups 1-7), with 6 rats in each group. Rats in each group were administered the drug intravenously and blood samples were taken after steady state, high performance liquid chromatography(HPLC) characterization profiles of the testing drugs and plasma components in each group were established, and the peak area changes of the drugs and plasma components in each group were calculated after the component groups were classified. Enzyme-linked immunosorbent assay(ELISA) was used to determine the changes of immunoglobulin E(IgE), histamine(HIS), tryptase(TPS), total complement(CH50) and terminal complement complex(C5b-9) in animal blood samples. MATLAB R2020b v9.9.0 software was used to calculate the network balance constants of the component groups with the targets, and the eigenvalues of the matrices composed of network equilibrium constants were calculated and ranked according to their values. ResultELISA results showed that, compared with the blank group, groups 1-3 could significantly increase the IgE level, groups 1-2, groups 4-6 and SHLI standard group could significantly increase the HIS level, group 4 could significantly increase the CH50 level, groups 1, 3-4, LJF group and FF group could significantly increase the TPS level, SR group could significantly increase the C5b-9 level, and the differences were all statistically significant(P<0.05). According to the retention time of chromatographic peaks, it was classified into 6 component groups from C1 to C6 by HPLC. The order of the network balance constants of each component group was C6>C4>C1>C5>C3>C2, indicating that C6 had the greatest effect on the allergic reaction, and was most likely to be the allergen. The sequence of eigenvalues was C2>C5b-9>C3>C1>CH50>C6>C5>IgE>TPS>C4>HIS, indicating that component group C2 had the greatest contribution to the whole network. ConclusionBased on the correlation analysis of SHLI component group and allergy-like target network, this study clarified that component group C6 may be a potential allergen in SHLI, and the component group C2 may be a key node in the mechanism of drug action, which can provide new strategies and methods for the screening of allergens in TCM injections.

Result Analysis
Print
Save