1.Effectiveness of digital three-dimensional printing osteotomy guide plate assisted total knee arthroplasty in treatment of knee osteoarthritis patients with femoral internal implant.
Chao LI ; Binbin ZHANG ; Xiangping LIU ; Haiya LI ; Jingtang ZHANG ; Min WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):151-157
OBJECTIVE:
To investigate the effectiveness of digital three-dimensional (3D) printing osteotomy guide plate assisted total knee arthroplasty (TKA) in treatment of knee osteoarthritis (KOA) patients with femoral internal implants.
METHODS:
The clinical data of 55 KOA patients who met the selection criteria between July 2021 and October 2023 were retrospectively analyzed. Among them, 26 cases combined with femoral implants were treated with digital 3D printing osteotomy guide plate assisted TKA (guide plate group), and 29 cases were treated with conventional TKA (control group). There was no significant difference in gender, age, body mass index, side, Kellgren-Lawrence classification, preoperative visual analogue scale (VAS) score, Hospital for Special Surgery (HSS) knee score, knee range of motion, and other baseline data between the two groups ( P>0.05). The operation time, intraoperative blood loss, incision length, postoperative first ambulation time, surgical complications; VAS score, knee HSS score, knee range of motion before operation, at 1 week and 3 months after operation, and at last follow-up; distal femoral lateral angle, proximal tibial medial angle, hip-knee-ankle angle and other imaging indicators at last follow-up were recorded and compared between the two groups.
RESULTS:
The operation time, incision length, intraoperative blood loss, and postoperative first ambulation time in the guide plate group were significantly lower than those in the control group ( P<0.05). In the control group, there were 1 case of incision rupture and bleeding and 1 case of lower limb intermuscular venous thrombosis, which was cured after symptomatic treatment. There was no complication such as neurovascular injury, incision infection, or knee prosthesis loosening in both groups. Patients in both groups were followed up 12-26 months, with an average of 16.25 months. The VAS score, HSS score, and knee range of motion improved at each time point after operation in both groups, and further improved with time after operation, the differences were significant ( P<0.05). The above indicators in the guide plate group were significantly better than those in the control group at 1 week and 3 months after operation ( P<0.05), and there was no significant difference between the two groups at last follow-up ( P>0.05). At last follow-up, the distal femoral lateral angle, the proximal tibial medial angle, and the hip-knee-ankle angle in the guide plate group were significantly better than those in the control group ( P<0.05).
CONCLUSION
The application of digital 3D printing osteotomy guide plate assisted TKA in the treatment of KOA patients with femoral implants can simplify the surgical procedures, overcome limitations of conventional osteotomy guides, reduce surgical trauma, achieve individualized and precise osteotomy, and effectively restore lower limb alignment and knee joint function.
Humans
;
Arthroplasty, Replacement, Knee/instrumentation*
;
Osteoarthritis, Knee/surgery*
;
Osteotomy/instrumentation*
;
Male
;
Retrospective Studies
;
Female
;
Printing, Three-Dimensional
;
Femur/surgery*
;
Middle Aged
;
Bone Plates
;
Range of Motion, Articular
;
Aged
;
Treatment Outcome
;
Surgery, Computer-Assisted/methods*
;
Knee Prosthesis
;
Knee Joint/surgery*
;
Operative Time
2.Functional and aesthetic evaluation of external fixator lengthening through plantar approach for fourth brachymetatarsia.
Jiadong ZHANG ; Ning ZHANG ; Zheng HUANG ; Yang WANG ; Wenpeng XU ; Yong HU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(8):1020-1024
OBJECTIVE:
To evaluate the functional and aesthetic evaluation of external fixator lengthening through plantar approach for fourth brachymetatarsia.
METHODS:
A retrospective analysis was conducted on 20 patients (23 feet) with fourth brachymetatarsia who met the selection criteria between January 2016 and January 2024, including 3 males and 17 females, with 8 left, 9 right, and 3 bilateral cases. The mean age was 24.7 years (range, 14-51 years). The preoperative metatarsal shortening length was (13.8±3.2) mm. The preoperative American Orthopaedic Foot and Ankle Society (AOFAS) forefoot score was 79.5±3.9, the visual analogue scale (VAS) score of appearance satisfaction was 1.7±0.8, and the appearance index (AI) score was 13.6±0.9. All patients underwent external fixator lengthening through plantar approach. The lengthening length of metatarsal bone, lengthening ratio, healing time, and healing index were recorded. Functional outcomes were assessed using the AOFAS forefoot score, VAS score of appearance satisfaction, and quality-of-life impact with AI questionnaire.
RESULTS:
All 20 patients were followed up 14-55 months with an average of 36.3 months. During the follow-up, complications occurred in 4 cases (17.4%), including 2 cases of metatarsophalangeal joint stiffness, which had no significant effect on the function and appearance. Delayed union of osteotomy occurred in 1 case (healed at 12 weeks after operation). Pin loosening occurred in 1 case and recovered after outpatient reinforcement. No complications related to plantar scar occurred. At last follow-up, the lengthening length of metatarsal bone was (13.9±3.1) mm, and the lengthening ratio was 25.8%±5.6%. All cases achieved bony union, with a mean healing time of (64.3±12.5) days and a healing index of (46.9±4.8) d/cm. At last follow-up, AOFAS score was 98.9±2.1, the VAS score of appearance satisfaction was 9.3±0.7, and the AI score was 0.6±0.8, which significantly improved when compared with those before operation ( t=27.398, P<0.001; t=32.994, P<0.001; t=56.135, P<0.001).
CONCLUSION
External fixator lengthening through plantar approach is a safe and effective technique for fourth brachymetatarsia, achieving satisfactory functional and aesthetic outcomes.
Humans
;
Male
;
Female
;
Adult
;
External Fixators
;
Retrospective Studies
;
Bone Lengthening/instrumentation*
;
Middle Aged
;
Metatarsal Bones/abnormalities*
;
Adolescent
;
Young Adult
;
Treatment Outcome
;
Patient Satisfaction
;
Esthetics
;
Osteotomy/methods*
;
Foot Deformities, Congenital/surgery*
3.Comparison of effectiveness of multiple metatarsal osteotomy and first metatarsophalangeal arthrodesis for severe metatarsal adductus hallux valgus deformity.
Shengyuan LAN ; Xingchen LI ; Xiangyang XU ; Yuan ZHU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(10):1246-1250
OBJECTIVE:
To compare effectiveness of multiple metatarsal osteotomy versus first metatarsophalangeal arthrodesis in treating severe metatarsal adductus hallux valgus deformity.
METHODS:
A retrospective analysis was conducted on the clinical data of 25 patients with severe metatarsal adductus hallux valgus deformity admitted between June 2010 and May 2014 who met the selective criteria. Among them, 15 patients underwent multiple metatarsal osteotomy (osteotomy group), while 10 patients underwent first metatarsophalangeal arthrodesis (fusion group). There was no significant difference between groups ( P>0.05) in gender, age, disease duration, affected side, preoperative American Orthopaedic Foot and Ankle Society (AOFAS) score, visual analogue scale (VAS) score for pain, intermetatarsal angle (IMA), hallux valgus angle (HVA), or metatarsal adduction angle (MAA). The osteotomy group underwent fixation with screws and/or staples fixation, while the fusion group utilized anatomic fusion plates and trans-articular compression screws. The study compared the following outcome indicators between groups: operation time, pre- and post-operative differences (change values) in AOFAS scores, VAS scores, and radiographic parameters (HVA, MAA), osteotomy healing outcomes, and recurrence of hallux valgus deformity.
RESULTS:
Both surgical procedures were completed successfully. The operation time was significantly shorter in the fusion group than in the osteotomy group ( P<0.05). All patients were followed up 96-144 months (mean, 116 months). The follow-up time was (129.1±7.2) months in the osteotomy group and (104.4±8.0) months in the fusion group, with no significant difference between groups ( P>0.05). X-ray films revealed the radiographic union in two groups, and the fusion time was significantly shorter in the fusion group than in the osteotomy group ( P<0.05). At last follow-up, both groups demonstrated significant improvements in AOFAS and VAS scores compared to preoperative levels ( P<0.05). However, the differences in the change values of AOFAS and VAS scores between groups were not significant ( P>0.05). During follow-up, 3 cases (20%) of deformity recurrence occurred in the osteotomy group, while no recurrence was observed in the fusion group. There was no significant difference in the incidences of deformity recurrence between groups ( P>0.05).
CONCLUSION
For severe metatarsus adductus hallux valgus deformities, both multiple metatarsal osteotomy and first metatarsophalangeal arthrodesis can correct the deformity. The former preserves metatarsophalangeal joint mobility but demands high technical proficiency from the surgeon, involves relatively longer operation times, extended bone healing periods, and higher complication incidences. The latter procedure is relatively simpler, facilitates faster postoperative recovery, allows early weight-bearing, and yields more reliable outcomes, though it sacrifices first metatarsophalangeal joint mobility.
Humans
;
Osteotomy/methods*
;
Hallux Valgus/diagnostic imaging*
;
Retrospective Studies
;
Arthrodesis/instrumentation*
;
Treatment Outcome
;
Metatarsal Bones/diagnostic imaging*
;
Metatarsophalangeal Joint/diagnostic imaging*
;
Male
;
Female
;
Bone Screws
;
Adult
;
Middle Aged
;
Bone Plates
;
Pain Measurement
4.Fixation of Intertrochanteric Valgus Osteotomy with T Plate in Treatment of Developmental Coxa Vara.
Mohamed Mansour ELZOHAIRY ; Hosam Mohamed KHAIRY
Clinics in Orthopedic Surgery 2016;8(3):310-315
BACKGROUND: Although the valgus subtrochanteric osteotomy is considered as a standard surgical treatment for coxa vara, there is no consensus on the optimal method of fixation and osteotomy technique. Fixation of the osteotomy has been achieved by various methods including external fixation and internal fixation with pins and cerclage and a variety of plates. The aim of this study is the evaluation of the results of developmental coxa treated by Y intertrochanteric valgus osteotomy fixed with a T-buttress plate compared with other methods of fixation in the literature. METHODS: Eighteen corrective valgus intertrochanteric femoral osteotomies were performed in 18 patients (18 hips) for treatment of unilateral developmental coxa vara deformity and fixed with a T plate. There were 12 males and 6 females. The right hip was affected in 10 patients and the left hip in 8 patients. Clinically, patients were evaluated by Larson hip score. Radiographically, anteroposterior view of the pelvis and frog leg lateral views of the affected hip were taken preoperatively and compared with the findings at the final follow-up. RESULTS: The average follow-up was 29 months (range, 24 to 36 months). Clinical results showed improvement of the mean Larson hip score from 57.8 to 97.0 (p < 0.001). Radiological results showed that all osteotomies were completely united in 2.4 months (range, 2 to 3 months) with the achievement of the planned correction angle. The average correction of Hilgenreiner's epiphyseal angle improved from 78.2° to 27.8° (p < 0.001) at the final follow-up. The femoral neck shaft angle was improved from 93.7° to 129.9° (p < 0.001) at the final follow-up. Shortening of the affected limb was corrected from 2.8 cm to 1.3 cm (p < 0.001) at the last follow-up. No major serious complications were recorded in the present study. CONCLUSIONS: Intertrochanteric valgus osteotomy of the proximal femur fixed with a T plate may be efficient for treatment of developmental coxa vara. With careful planning, it can result in a low complication rate and insignificant or minimal recurrence rate.
*Bone Plates
;
Child
;
Child, Preschool
;
Coxa Vara/*surgery
;
Female
;
Femur Neck/*surgery
;
Follow-Up Studies
;
*Fracture Fixation, Internal/instrumentation/methods/statistics & numerical data
;
Humans
;
Male
;
*Osteotomy/methods/statistics & numerical data
5.Case-control study on individual osteotomy instrument and conventional total knee arthroplasty for the treatment of knee osteoarthritis.
Hua-chen YU ; Yu ZHANG ; Paul WONG
China Journal of Orthopaedics and Traumatology 2016;29(6):513-516
OBJECTIVETo compare clinical efficacy of individual osteotomy instrument and total knee arthrolplasty (TKA) in treating patients with knee osteoarthritis.
METHODSFrom June 2014 to December 2014, 40 patients with unilateral knee osteoarthritis were randomly divided into two groups and 20 cases were in each group. One group (individual group) were treated with TKA with individual osteotomy instrument,including 5 males and 15 females with an average age of (67.3 ± 6.5) years old; 8 cases on the left side and 12 cases on the right side. Another group (conventional group) were treated with conventional TKA , including 6 males and 14 females with an average age of (66.8 ± 7.3) years old; 9 cases on the left side and 11 cases on the right side. Operative time, blood loss, postoperative HSS score at 6 months, and changes of mechanical alignment before and after operation were analyzed.
RESULTSOperative time in individual group was (79.3 ± 4.7) min, and (83.5 ± 3.2) min in conventional group; blood loss in individual group was (287.1 ± 24.9) ml and (363.4 ± 47.2) ml in conventional group, there were statistical differences between two groups in these two items. There was no significant difference in postoperative HSS score at 6 months between individual group (84.8 ± 3.2) and conventional group (84.2 ± 2.5). Postoperative limb alignment in individual group was (2.8 ± 0.6)°, and (2.8 ± 0.6)° in conventional group, with no significant difference between two groups.
CONCLUSIONTKA with individual osteotomy instrument could reduce operative time and blood loss, but there was no differences in knee function, changes of mechanical alignment compared with TKA.
Adult ; Aged ; Arthroplasty, Replacement, Knee ; methods ; Case-Control Studies ; Female ; Humans ; Knee Joint ; surgery ; Male ; Operative Time ; Osteoarthritis, Knee ; surgery ; Osteotomy ; instrumentation ; methods ; Treatment Outcome
6.First Metatarsal Proximal Opening Wedge Osteotomy for Correction of Hallux Valgus Deformity: Comparison of Straight versus Oblique Osteotomy.
Seung Hwan HAN ; Eui Hyun PARK ; Joon JO ; Yong Gon KOH ; Jin Woo LEE ; Woo Jin CHOI ; Yong Sang KIM
Yonsei Medical Journal 2015;56(3):744-752
PURPOSE: The aim of this study was to compare clinical and radiographic outcomes of proximal opening wedge osteotomy using a straight versus oblique osteotomy. MATERIALS AND METHODS: We retrospectively reviewed 104 consecutive first metatarsal proximal opening wedge osteotomies performed in 95 patients with hallux valgus deformity. Twenty-six feet were treated using straight metatarsal osteotomy (group A), whereas 78 feet were treated using oblique metatarsal osteotomy (group B). The hallux valgus angle (HVA), intermetatarsal angle (IMA), distal metatarsal articular angle, and distance from the first to the second metatarsal (distance) were measured for radiographic evaluation, whereas the American Orthopaedic Foot and Ankle Society (AOFAS) forefoot score was used for clinical evaluation. RESULTS: Significant corrections in the HVA, IMA, and distance from the first to the second metatarsal were obtained in both groups at the last follow-up (p<0.001). There was no difference in the mean IMA correction between the 2 groups (6.1+/-2.7degrees in group A and 6.0+/-2.1degrees in group B). However, a greater correction in the HVA and distance from the first to the second metatarsal were found in group B (HVA, 13.2+/-8.2degrees; distance, 25.1+/-0.2 mm) compared to group A (HVA, 20.9+/-7.7degrees; distance, 28.1+/-0.3 mm; p<0.001). AOFAS scores were improved in both groups. However, group B demonstrated a greater improvement relative to group A (p=0.005). CONCLUSION: Compared with a straight first metatarsal osteotomy, an oblique first metatarsal osteotomy yielded better clinical and radiological outcomes.
Adult
;
Aged
;
Bone Plates
;
Epiphyses/surgery
;
Ethnic Groups
;
Female
;
Foot
;
Fracture Fixation, Internal/*instrumentation
;
Hallux Valgus/radiography/*surgery
;
Humans
;
Lower Extremity
;
Male
;
Metatarsal Bones/*radiography/*surgery
;
Middle Aged
;
Osteotomy/*methods
;
Range of Motion, Articular
;
Retrospective Studies
;
Treatment Outcome
;
Upper Extremity
7.Effect of Anteromedial Portal Entrance Drilling Angle during Anterior Cruciate Ligament Reconstruction: A Three-Dimensional Computer Simulation.
Dong Kyu MOON ; Chul Ho YOON ; Jin Seung PARK ; Bun Jung KANG ; Seong Hee CHO ; Ho Seung JO ; Sun Chul HWANG
Yonsei Medical Journal 2014;55(6):1584-1591
PURPOSE: The object of this study was to evaluate entrance angle effects on femoral tunnel length and cartilage damage during anteromedial portal drilling using three-dimensional computer simulation. MATERIALS AND METHODS: Data was obtained from an anatomic study performed using 16 cadaveric knees. The anterior cruciate ligament femoral insertion was dissected and the knees were scanned by computer tomography. Tunnels with different of three-dimensional entrance angles were identified using a computer simulation. The effects of different entrance angles on the femoral tunnel length and medial femoral cartilage damage were evaluated. Specifically, tunnel length and distance from the medial femoral condyle to a virtual cylinder of the femoral tunnel were measured. RESULTS: In tunnels drilled at a coronal angle of 45degrees, an axial angle of 45degrees, and a sagittal angle of 45degrees, the mean femoral tunnel length was 39.5+/-3.7 mm and the distance between the virtual cylinder of the femoral tunnel and the medial femoral condyle was 9.4+/-2.6 mm. The tunnel length at a coronal angle of 30degrees, an axial angle of 60degrees, and a sagittal angle of 45degrees, was 34.0+/-2.9 mm and the distance between the virtual cylinder of the tunnel and the medial femoral condyle was 0.7+/-1.3 mm, which was significantly shorter than the standard angle (p<0.001). CONCLUSION: Extremely low and high entrance angles in both of axial plane and coronal plane produced inappropriate tunnel angles, lengths and higher incidence of cartilage damage. We recommend that angles in proximity to standard angles be chosen during femoral tunnel drilling through the anteromedial portal.
Aged
;
Anterior Cruciate Ligament/*surgery
;
Anterior Cruciate Ligament Reconstruction/instrumentation/*methods
;
Cadaver
;
Computer Simulation
;
Female
;
Femur/anatomy & histology/*surgery
;
Humans
;
Imaging, Three-Dimensional
;
Knee Joint/radiography/*surgery
;
Male
;
Middle Aged
;
Osteotomy/*methods
;
Outcome and Process Assessment (Health Care)
;
Patient Positioning
;
Surgical Instruments
;
Tomography, X-Ray Computed
8.The anatomical safe zone for medial opening oblique wedge high tibial osteotomy.
Bavornrat VANADURONGWAN ; Thana SIRIPISITSAK ; Narumol SUDJAI ; Thossart HARNROONGROJ
Singapore medical journal 2013;54(2):102-104
INTRODUCTIONThe end of medial opening oblique wedge high tibial osteotomy (HTO) points into a narrow area between the articular cartilage of the posterolateral proximal tibia and proximal tibiofibular joint (PTFJ) at the tibial site, which is an anatomical safe zone (ASZ) for osteotomy. We studied the ASZ and its relation to the fibular tip, including the level of posterior cruciate ligament (PCL) insertion, to avoid penetration into the knee and PTFJ, and PCL injury by osteotomy.
METHODSTen pairs of embalmed cadaveric legs were disarticulated at the knee joint and then examined. Soft tissues at the proximal tibia were removed. The posterior capsule of the PTFJ was incised to identify the articular cartilage of the PTFJ at the tibial site. The height of the fibular tip and the thickness of the ASZ were measured and calculated to determine the relationship between the ASZ and fibular tip. The level of PCL insertion was measured from the posterior articular surface of the proximal tibia to the distal attachment of the PCL.
RESULTSThe average height of the fibular tip and the thickness of the ASZ were 5.43 ± 1.53 mm and 4.12 ± 1.60 mm, respectively. On average, the fibular tip was 1.31 ± 1.28 mm higher than the ASZ, and the level of PCL insertion was 10.10 ± 1.88 mm.
CONCLUSIONTo ensure safety during medial opening oblique wedge HTO, the end of osteotomy should point accurately into the ASZ at a level just below the fibular tip as reference. Proximal osteotomy thickness should not be less than 10 mm at the level of PCL insertion.
Cadaver ; Cartilage, Articular ; surgery ; Fibula ; anatomy & histology ; Humans ; Knee ; anatomy & histology ; Knee Joint ; anatomy & histology ; Middle Aged ; Osteotomy ; instrumentation ; methods ; Posterior Cruciate Ligament ; anatomy & histology ; Tibia ; anatomy & histology ; surgery
9.Limb Angular Deformity Correction Using Dyna-ATC: Surgical Technique, Calculation Method, and Clinical Outcome.
Hoon PARK ; Hyun Woo KIM ; Hui Wan PARK ; Ki Seok LEE
Yonsei Medical Journal 2011;52(5):818-830
PURPOSE: Dyna-ATC is a unilateral external fixator with angulator, lengthener, and translator, which allows for angular correction and compensation of the secondary displacement during angular correction. The purpose of this study is to introduce surgical technique and calculation methods and to evaluate the clinical outcome of angular deformity correction using Dyna-ATC. MATERIALS AND METHODS: The amounts of secondary displacement were calculated with the distances between axis of correction of angulation, Center of Rotational Angulation, and osteotomy and the amount of angular deformity. The rate of angular correction was determined to distract the corticotomy at 1 mm/day. Clinical and radiographic evaluation was performed on 13 patients who underwent deformity correction using Dyna-ATC. There were 8 proximal tibia vara, 1 tibia valga, 2 varus and 4 valgus deformities on distal femur. One patient underwent pelvic support femoral reconstruction. Concomitant lengthening was combined in all femur cases. Mean age at surgery was 17.5 years (7 to 64). RESULTS: All but one achieved bony healing and normal alignment with the index procedure. Mean mechanical axis deviation improved from 31.9 mm to 3.0 mm. The average amount of angular correction was 11.0degrees on tibiae and 10.0degrees on femora. The average length gain on femora was 6.4 cm, and the healing index averaged to 1.1 mo/cm. One patient underwent quadricepsplasty and one patient had three augmentation surgeries due to poor new bone formation. CONCLUSION: We believe that Dyna-ATC is a useful alternative to bulky ring fixators for selective patients with angular deformity less than 30 degrees in the coronal plane around the knee joint.
Adolescent
;
Bone Diseases, Developmental/*surgery
;
Child
;
*External Fixators
;
Female
;
Femur/abnormalities/surgery
;
Humans
;
Leg Length Inequality/surgery
;
Lower Extremity Deformities, Congenital/*surgery
;
Male
;
Middle Aged
;
Osteochondrosis/congenital/surgery
;
Osteogenesis, Distraction/*instrumentation/methods/statistics & numerical data
;
Osteotomy
;
Tibia/abnormalities/surgery
;
Treatment Outcome
;
Young Adult
10.Application of tunable guide device in prominent mandibular angle osteotomy.
Liang-gang YU ; Jia-yi HAN ; Xiong-zheng MU
Chinese Journal of Plastic Surgery 2010;26(1):24-26
OBJECTIVETo discuss the application and therapeutic effect of tunable guide device in correction of prominent mandibular angle.
METHODSSince 2007, 50 cases with prominent mandible angle underwent mandible angle osteotomy with the tunable guide device. The patients were followed up for 3-6 months.
RESULTSNo severe complication happened. Local seroma occurred in one case. Improved esthetic results were achieved at both frontal and oblique view.
CONCLUSIONSThe mandibular angle osteotomy with the tunable guide device makes the procedure safe and easily performed.
Adult ; Female ; Humans ; Mandible ; abnormalities ; surgery ; Osteotomy ; instrumentation ; methods ; Young Adult

Result Analysis
Print
Save
E-mail