1.Efficacy analysis of gasless robotic surgery via transaxillary approach for unilateral N1b PTC.
Faya LIANG ; Xin ZOU ; Peiliang LIN ; Ping HAN ; Renhui CHEN ; Xijun LIN ; Jingyi WANG ; Xiangwei KONG ; Lanlan DENG ; Xiaoming HUANG
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(11):1009-1015
Objective:To compare the efficacy of gasless robotic surgery via transaxillary approach and combined axillary-retroauricular approach for unilateral N1b PTC, and to explore the safety and effectiveness of gasless robotic surgery via transaxillary approach for unilateral N1b PTC. Methods:Unilateral N1b PTC patients who underwent surgery in the Department of Otolaryngology, Sun Yat Sen Memorial Hospital, Sun Yat sen University between July 2016 and December 2024 were included and analyzed. According to the inclusion and exclusion criteria and the differences of surgical approaches, the patients were divided into the transaxillary approach(TA) group and the combined axillary-retroauricular approach(TARA) group. The demographic data, operation time, intraoperative blood loss, postoperative drainage volume, postoperative complications, shoulder function evaluation, postoperative visual analogue scale(VAS) of neck aesthetics and recurrence of the two groups were statistically analyzed. Results:A total of 88 patients undergoing gasless robotic surgery were included in this study, including 23 cases in the TA group and 65 cases in the TARA group. The proportion of males in the TA group was significantly higher than that in the TARA group(56.5% vs 21.5%, χ²=9.776, P=0.002). The total operation time in the TA group was significantly lower than that in the TARA Group(180.00[155.00, 220.00]min vs 220.00[177.50, 272.50]min, z=-2.775, P=0.006), and the postoperative blood loss in the TA group was significantly lower than that in the TARA Group(30.00[20.00, 50.00]ml vs 50.00[30.00, 60.00]ml, Z=-2.127, P=0.033). The proportion of area Ⅱ-Ⅴ in the TA group and the TARA group was 87.0% and 70.8%, respectively, and there was no significant difference between the two groups(P>0.05). There was no significant difference in lateral cervical lymph node dissection and central lymph node dissection between the two groups(P>0.05). During the follow-up period, no recurrence was found in the two groups, and there was no significant difference in the incidence of complications between the two groups(P>0.05). According to the stratification of dynamic recurrence risk assessment, it can be seen that the proportion of curative effect satisfaction in the TA group was as high as 95.7%, and that in the TARA group was as high as 81.5%, with no significant difference between the two groups. There was no significant difference in VAS score of neck, Constant Shoulder Score and NDⅡ scale between the two groups(P>0.05). Conclusion:Gasless robotic surgery via transaxillary approach for unilateral N1b PTC is safe and feasible, and the amount postoperative lymph node acquisition is equivalent to that of combined axillary-retroauricular approach, which can provide a new choice for the treatment of unilateral N1b PTC patients.
Humans
;
Robotic Surgical Procedures/methods*
;
Axilla/surgery*
;
Male
;
Female
;
Operative Time
;
Middle Aged
;
Adult
;
Treatment Outcome
;
Postoperative Complications
2.Clinical application of inflatable unilateral axillary approach robot assisted bilateral thyroid lobe lesion resection.
Di WU ; Zheng ZHAO ; Qi FANG ; Fei CAO ; Ruobin LIN ; Jun CHEN ; Xuekui LIU
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(11):1022-1027
Objective:To evaluate the feasibility, safety, and short-term efficacy of robot-assisted unilateral axillary approach for partial or total thyroidectomy without inflation. Methods:A retrospective analysis was performed on the clinical data of 98 patients who underwent gasless unilateral axillary approach robot-assisted resection of bilateral thyroid lesions at Sun Yat-sen University Cancer Center between October 2022 and October 2024. Perioperative indicators were recorded and compared among patients undergoing different surgical approaches(total thyroidectomy vs. bilateral partial thyroidectomy) and with different body mass index(BMI) values, including operative time, intraoperative blood loss, number of lymph nodes dissected, incidence of postoperative hoarseness, incidence of postoperative hypocalcemia, and other postoperative complications. Results:A total of 98 patients were included, of whom 78.57% were female, with a median age of 39 years(interquartile range[IQR]: 35-49) and a median BMI of 24.08 kg/m²(IQR: 21.43-25.98). The median intraoperative blood loss was 32.14 mL(IQR: 20.00-50.00), the median operative time was 130.0 minutes(IQR: 104.80-150.30), and the median hospital stay was 2.01 days(IQR: 1.00-2.00). The most common postoperative complication was transient hypocalcemia, with an incidence of 16.32%. There were no cases of permanent recurrent laryngeal nerve palsy or conversion to open surgery. Compared with the non-total thyroidectomy group, the total thyroidectomy group had a significantly longer operative time(135.10±33.28 min vs 120.30±30.53 min, P=0.033). Subgroup analysis based on BMI showed no statistically significant differences in operative time, hospital stay, drainage volume, or incidence of hypocalcemia between patients with BMI≥25 kg/m² and those with BMI<25 kg/m². Conclusion:The gasless unilateral axillary approach for robot-assisted partial or total thyroidectomy demonstrates favorable safety, cosmetic outcomes, and feasibility. Appropriate selection of surgical techniques and meticulous protection of critical structures during the procedure can further reduce the risk of complications and optimize therapeutic outcomes.
Humans
;
Thyroidectomy/methods*
;
Retrospective Studies
;
Female
;
Robotic Surgical Procedures/methods*
;
Male
;
Adult
;
Middle Aged
;
Axilla/surgery*
;
Operative Time
;
Postoperative Complications
;
Thyroid Neoplasms/surgery*
;
Thyroid Gland/surgery*
;
Lymph Node Excision
3.Single-Center clinical application and analysis of Robot-Assisted endoscopic salivary gland surgery via a postauricular approach.
Ping HAN ; Faya LIANG ; Peiliang LIN ; Ying LI ; Renhui CHEN ; Xiaoming HUANG
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(11):1028-1033
Objective:Traditional salivary gland surgery involves incisions in the visible facial and cervical regions, leaving postoperative scars that affect cosmesis. This study aims to investigate the clinical efficacy, safety, and application value of robot-assisted endoscopic resection of benign submandibular and parotid gland lesions via a postauricular approach, while clarifying its advantageous differences compared with endoscopic surgery. Methods:Clinical data of 23 patients who underwent robot-assisted endoscopic surgery via a postauricular approach(11 parotid gland cases and 12 submandibular gland cases) from January 2017 to February 2025 were retrospectively analyzed. Meanwhile, A matched control group of patients who received postauricular endoscopic surgery during the same period was selected as the control group in a 1∶1 ratio(11 parotid gland cases and 12 submandibular gland cases). Indicators such as operation time, intraoperative blood loss, complications, and postoperative aesthetic satisfaction scores(Numeric Satisfaction Scale, NSS) were collected and compared between the two groups. The inclusion criteria were limited to benign lesions of the parotid superficial lobe(diameter ≤5 cm, without deep lobe involvement) and benign submandibular gland lesions(diameter ≤4 cm, without extension through the mylohyoid muscle). Results:All robot-assisted surgeries were successfully completed without conversion to open surgery. In the robot group, there were 7 male patients(mean age 39.5 years) and 16 female patients(mean age 35.9 years). For parotid gland surgeries, the mean operation time was (114.00±38.35) minutes. For submandibular gland surgeries, the mean operation time was(140.00±30.75) minutes.Temporary facial paralysis occurred in 0 of patients after robotic submandibular gland surgery (vs.8% in the endoscopic group) and 18% after robotic parotid gland surgery (vs.27 % in the endoscopic group),all of which resolved within 1 month, with no occurrence of salivary fistula or infection. Patients had high aesthetic satisfaction(NSS scores: 8.90±1.20 for parotid surgeries and 9.00±0.70 for submandibular surgeries). No tumor recurrence was observed during the 8-77 month follow-up period. Conclusion:Robot-assisted endoscopic salivary gland surgery via a postauricular approach is safe and feasible. With three-dimensional high-definition visualization and precise mechanical manipulation, it outperforms traditional endoscopic surgery in reducing blood loss, lowering the risk of nerve injury, and achieving long-term cosmetic outcomes. It is particularly suitable for young patients and cases with benign lesions of the parotid superficial lobe or submandibular gland that have high aesthetic demands. However, this surgical approach is not suitable for deep parotid lobe tumors, and its long-term efficacy requires verification through large-sample studies.
Humans
;
Robotic Surgical Procedures/methods*
;
Retrospective Studies
;
Endoscopy/methods*
;
Submandibular Gland/surgery*
;
Parotid Gland/surgery*
;
Female
;
Male
;
Operative Time
;
Salivary Glands/surgery*
;
Adult
;
Middle Aged
4.Application of domestic single-port robotic surgical system in thyroid cancer.
Qian MA ; Sicheng ZHANG ; Longyue ZHANG ; Jinyuan LIU ; Ronghao SUN ; Yuqiu ZHOU ; Linjie MA ; Chunyan SHUI ; Yongcong CAI ; Chao LI
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(11):1044-1047
Objective:To explore the feasibility and preliminary efficacy of domestic single-port robotic surgical system in the surgical treatment of thyroid cancer. Methods:Thyroid cancer patients who underwent domestic single-port robotic surgery in the Department of Head and Neck Surgery of Sichuan Cancer Hospital from June 2024 to January 2025 were prospectively included. Clinical data, oncological characteristics, and perioperative indicators were systematically collected. Results:A total of 7 patients were included, including 3 males and 4 females, with an age of (34.57±10.26) years. All procedures were successfully completed without conversion to open surgery. Operative time was(180.00±30.41) minutes. Blood loss was(5.00[15.00 ])mL. Postoperative drainage volume was (167.86±130.95) mL. The postoperative pathological results were all thyroid papillary carcinoma. There were no system failures, no device-related complications and adverse events were observed during the operation and perioperative period. No tumor recurrence or metastasis was observed during the follow-up period. Conclusion:Preliminary data indicate that the domestic single-port robotic surgical system is safe and feasible for the surgical treatment of thyroid cancer, providing a practical basis for subsequent multi-disease, multi-center, and large-sample studies.
Humans
;
Thyroid Neoplasms/surgery*
;
Robotic Surgical Procedures/instrumentation*
;
Male
;
Female
;
Adult
;
Thyroidectomy/methods*
;
Operative Time
;
Middle Aged
;
Prospective Studies
5.Application of domestic jingfeng single-port robotic-assisted surgery in multisite diseases of oropharyngeal-head and neck region: case series.
Ping HAN ; Faya LIANG ; Peiliang LIN ; Junyu CHEN ; Jingyi WANG ; Yanke LIU ; Xiaoming HUANG
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(11):1048-1056
Objective:To evaluate the safety, feasibility, and technical advantages of the domestic Jingfeng single-port robotic surgical system in transoral and transaxillary approach surgeries for multisite diseases. Methods:A retrospective analysis was conducted on the clinical data of 6 patients who underwent Jingfeng SP1000 single-port robotic-assisted surgery at our hospital from June 2025 to July 2025. They were divided into the transoral robotic surgery group(4cases) and the transaxillary approach thyroid cancer radical resection group(2cases) based on surgical approaches. The transoral robotic surgery group included extended resection of right tonsillar cancer with cervical lymph node dissection, epiglottic cyst resection, extended resection of right pyriform sinus cancer with cervical lymph node dissection, and surgery for epiglottic cyst and obstructive sleep apnea(OSA). For each case, parameters including operative time, intraoperative blood loss, perioperative complications, robotic operation performance, and postoperative recovery were recorded. Results:All 6 surgeries were successfully completed without conversion to open surgery or system failure. In the transoral robotic surgery group, the mean robotic operation time was(60.00±34.88) minutes, and the mean intraoperative blood loss was 20.00(5.75,20.00)mL. In the transaxillary robotic surgery group, the robotic operation time was respectively 60.00 and 40.00 minutes, and the intraoperative blood loss was 10.00 and 5.00 mL, respectively. One case of minor perioperative complication(in the flap dissection area) occurred, with no severe complications reported. All patients recovered smoothly after surgery, with a median follow-up of 1.9 months showing no residual lesions, recurrence, or functional impairment. Conclusion:This case series confirms the safety and feasibility of the domestic Jingfeng single-port robot in transoral and axillary approach surgeries in oropharyngeal-head and neck surgery. Its single-port design reduces trauma and the risk of robotic arm collision, adapts to minimally invasive needs, and its domestic production attribute lowers costs to facilitate popularization, providing a new option for such patients.
Humans
;
Robotic Surgical Procedures/methods*
;
Retrospective Studies
;
Operative Time
;
Middle Aged
;
Male
;
Female
;
Neck/surgery*
;
Sleep Apnea, Obstructive/surgery*
;
Adult
;
Head and Neck Neoplasms/surgery*
;
Oropharynx/surgery*
;
Oropharyngeal Neoplasms/surgery*
6.Early effectiveness of navigation-free robot-assisted total knee arthroplasty in treating knee osteoarthritis with extra-articular deformities.
Chen MENG ; Yongqing XU ; Rongmao SHI ; Luqiao PU ; Jian'an JI ; Xingyou YAO ; Xizong ZHOU ; Chuan LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):5-12
OBJECTIVE:
To evaluate the early effectiveness of navigation-free robot-assisted total knee arthroplasty (TKA) compared to traditional TKA in the treatment of knee osteoarthritis combined with extra-articular deformities.
METHODS:
The clinical data of 30 patients with knee osteoarthritis combined with extra-articular deformities who met the selection criteria between June 2019 and January 2024 were retrospectively analyzed. Fifteen patients underwent CORI navigation-free robot-assisted TKA and intra-articular osteotomy (robot group) and 15 patients underwent traditional TKA and intra-articular osteotomy (traditional group). There was no significant difference in age, gender, body mass index, affected knee side, extra-articular deformity angle, deformity position, deformity type, and preoperative knee range of motion, American Knee Society (KSS) knee score and KSS function score, and lower limb alignment deviation between the two groups ( P>0.05). The operation time, intraoperative blood loss, and complications of the two groups were recorded and compared. The knee range of motion and lower limb alignment deviation were recorded before operation and at 6 months after operation, and the knee joint function was evaluated by KSS knee score and function score.
RESULTS:
There was no significant difference in operation time between the two groups ( P>0.05); the intraoperative blood loss in the robot group was significantly less than that in the traditional group ( P<0.05). Patients in both groups were followed up 6-12 months, with an average of 8.7 months. The incisions of all patients healed well, and there was no postoperative complication such as thrombosis or infection. At 6 months after operation, X-ray examination showed that the position of the prosthesis was good in both groups, and there was no loosening or dislocation of the prosthesis. The knee joint range of motion, the lower limb alignment deviation, and the KSS knee score and KSS function score significantly improved in both groups ( P<0.05) compared to preoperative ones. The changes of lower limb alignment deviation and KSS function score between pre- and post-operation in the robot group were significantly better than those in the traditional group ( P<0.05), while the changes of other indicators between pre- and post-operation in the two groups were not significant ( P>0.05).
CONCLUSION
Compared to traditional TKA, navigation-free robot-assisted TKA for knee osteoarthritis with extra-articular deformities results in less intraoperative blood loss, more precise reconstruction of lower limb alignment, and better early effectiveness. However, long-term effectiveness require further investigation.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Osteoarthritis, Knee/surgery*
;
Robotic Surgical Procedures/methods*
;
Male
;
Female
;
Retrospective Studies
;
Range of Motion, Articular
;
Middle Aged
;
Aged
;
Treatment Outcome
;
Osteotomy/methods*
;
Knee Joint/physiopathology*
;
Operative Time
7.TiRobot-assisted minimally invasive treatment of coracoid process fractures of scapula.
Yonghong DAI ; Qingyu LI ; Yanhui ZENG ; Zhengjie WU ; Chunpeng ZHAO ; Junqiang WANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):40-46
OBJECTIVE:
To explore effectiveness of TiRobot-assisted screw implantation in the treatment of coracoid process fractures of the scapula.
METHODS:
A retrospective analysis was conducted on the clinical data from 24 patients with coracoid process fractures of the scapula admitted between September 2019 and January 2024 and met selection criteria. Among them, 12 patients underwent TiRobot-assisted screw implantation (robot group) and 12 underwent manual screw implantation (control group) during internal fixation. There was no significant difference ( P>0.05) in baseline data such as gender, age, body mass index, disease duration, cause of injury, coracoid process fracture classification, and proportion of patients with associated injuries between the two groups. The incision length, operation time, intraoperative blood loss, hospital stay, accuracy of screw placement, coracoid process fracture healing time, and complications were recorded and compared, as well as pain visual analogue scale (VAS) score, and Constant-Murley score at last follow-up.
RESULTS:
The intraoperative blood loss and incision length in the robot group were significantly lower than those in the control group ( P<0.05); however, there was no significant difference in operation time and hospital stay between the two groups ( P>0.05). All patients were followed up 8-27 months (mean, 17.5 months), and the difference in follow-up time between the two groups was not significant ( P>0.05). At last follow-up, the VAS score for shoulder pain in the robot group was signifncatly lower compared to the control group, and the Constant-Murley score was significantly higher ( P<0.05). In the robot group, 16 screws were implanted intraoperatively, while 13 screws were implanted in the control group. Radiographic re-evaluation showed that the excellent and good rate of screw implantation was higher in the robot group (93.8%, 15/16) than in the control group (61.5%, 8/13), but the difference in the precision of screw implantation between the two groups was not significant ( P>0.05). Four patients in the robot group and 1 in the control group achieved double screws fixation; however, the difference in achieving double screws fixation between the two groups was not significant ( P>0.05). All fractures healed in both groups with 1 case of malunion in the control group. There was no significant difference in healing time between the two groups ( P>0.05). During follow-up, 1 patient in the control group experienced screw loosening and displacement. There was no significant difference in the incidence of screw loosening and fracture malunion between the two groups ( P>0.05).
CONCLUSION
Compared with manual screw implantation, TiRobot-assisted minimally invasive treatment of coracoid process fractures of the scapula can reduce intraoperative blood loss, shorten incision length, alleviate pain, and obtain better promote shoulder joint functional recovery.
Humans
;
Male
;
Female
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Minimally Invasive Surgical Procedures/instrumentation*
;
Adult
;
Middle Aged
;
Fractures, Bone/surgery*
;
Bone Screws
;
Coracoid Process/surgery*
;
Robotic Surgical Procedures/methods*
;
Scapula/surgery*
;
Treatment Outcome
;
Operative Time
;
Young Adult
;
Length of Stay
;
Blood Loss, Surgical
8.Short-term effectiveness of Gamma 3 U-Blade system for osteoporotic intertrochanteric fractures in the elderly.
Wenbin FAN ; Liu SHI ; Tian XIE ; Cheng ZHANG ; Xiangxu CHEN ; Hui CHEN ; Yunfeng RUI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):47-52
OBJECTIVE:
To compare the short-term effectiveness between Gamma 3 intramedullary nails and Gamma 3 U-Blade system in the treatment of osteoporotic intertrochanteric fractures in the elderly.
METHODS:
A retrospective analysis was conducted on the clinical data of 124 elderly patients with osteoporotic intertrochanteric fractures, who were admitted between February 2020 and February 2023 and met the selection criteria. The fractures were fixed with Gamma 3 intramedullary nails in 65 patients (control group) and Gamma 3 U-Blade systems in 59 patients (UB group). The differences between the two groups were not significant in age, gender, body mass index, American Society of Anesthesiologists (ASA) classification, bone mineral density, time from injury to operation, fracture classification, and affected side ( P>0.05). The operation time, intraoperative blood loss, hospital stay, and fracture healing time were recorded; the tip-apex distance, fracture reduction quality, and lag screw position were evaluated on X-ray films at immediate after operation; the lag screw sliding distance and change value of neck-shaft angle were measured on X-ray films at last follow-up. Harris hip score at 1 year after operation and the occurrence of internal fixation-related complications were compared between the two groups.
RESULTS:
The operation time, intraoperative blood loss, and hospital stay in the UB group increased compared to the control group, but the differences were not significant ( P>0.05). All patients in both groups were followed up 12-24 months (mean, 17.1 months). At 12 months after operation, there was no significant difference in the Harris hip score between the two groups ( P<0.05). Radiological examination showed that there was no significant difference between the two groups ( P>0.05) in terms of tip-apex distance, fracture reduction quality, and lag screw position. Fractures healed in both groups, and there was no significant difference in healing time ( P>0.05). At last follow-up, the change value of neck-shaft angle and lag screw sliding distance in the UB group were significantly lower than those in the control group ( P<0.05). During follow-up, no related complications occurred in the UB group, while 6 cases (9.2%) in the control group experienced complications, and the difference in the incidence was significant ( P<0.05).
CONCLUSION
For the osteoporotic intertrochanteric fractures in the elderly, the Gamma 3 U-Blade system fixation can achieve good short-term effectiveness, with better imaging results compared to Gamma 3 intramedullary nails fixation.
Humans
;
Retrospective Studies
;
Hip Fractures/surgery*
;
Male
;
Female
;
Aged
;
Fracture Fixation, Intramedullary/methods*
;
Osteoporotic Fractures/surgery*
;
Bone Nails
;
Bone Screws
;
Aged, 80 and over
;
Treatment Outcome
;
Fracture Healing
;
Operative Time
;
Length of Stay
9.Treatment of irreducible intertrochanteric femoral fractures in elderly by novel bone hook combined with finger-guided technique.
Zenghui ZHANG ; Tichao HAN ; Wei LI ; Yangyang ZHOU ; Junjun LIU ; Nannan LI ; Tiantian REN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):53-58
OBJECTIVE:
To investigate the feasibility and effectiveness of the novel bone hook combined with finger-guided technique in the treatment of irreducible intertrochanteric femoral fractures in elderly.
METHODS:
Between January 2021 and August 2023, 23 elderly patients with irreducible intertrochanteric femoral fractures were treated with the novel bone hook combined with finger-guided technique. There were 10 males and 13 females; the age ranged from 68 to 93 years (mean, 76.2 years). The time from injury to operation ranged from 36 to 76 hours (mean, 51.2 hours). According to the classification standard proposed by TONG Dake et alin 2021, there were 10 cases of typeⅠA, 1 case of typeⅠB, 6 cases of type ⅡA, 4 cases of type ⅡB, and 2 cases of type ⅡC. The operation time, intraoperative blood loss, intraoperative fluoroscopy frequences, and quality of fracture reduction were recorded. The fracture healing time and occurrence of postoperative complications were observed during follow-up. At last follow-up, the Harris scoring system was used to evaluate the hip joint function.
RESULTS:
The operation time was 42-95 minutes (mean, 52.1 minutes). The intraoperative blood loss was 40-420 mL (mean, 126.5 mL). Intraoperative fluoroscopy was performed 14-34 times (mean, 20.7 times). According to the criteria proposed by Chang et al, the quality of fracture reduction was rated as good in 20 cases and acceptable in 3 cases. All patients were followed up 6-20 months (mean, 10.2 months). X-ray film showed that all fractures healed with the healing time of 3.0-5.5 months (mean, 4.0 months). At last follow-up, the Harris score of the hip joint ranged from 82 to 97 points (mean, 90.4 points). Among them, 14 cases were rated as excellent and 9 cases as good. No complication such as coxa vara, cutting of the cephalomedullary nail, nail withdrawal, or nail breakage occurred during follow-up.
CONCLUSION
The treatment of elderly patients with irreducible intertrochanteric femoral fractures by using the novel bone hook combined with finger-guided technique can achieve high-quality fracture reduction and fixation, and has a good effectiveness.
Humans
;
Male
;
Female
;
Aged
;
Aged, 80 and over
;
Hip Fractures/diagnostic imaging*
;
Fracture Fixation, Internal/instrumentation*
;
Fracture Healing
;
Treatment Outcome
;
Operative Time
;
Fracture Fixation, Intramedullary/instrumentation*
;
Bone Nails
;
Postoperative Complications/epidemiology*
;
Feasibility Studies
;
Fingers
10.Comparison of effectiveness between two surgical methods for humeral lateral condyle fractures in children.
Hailong MA ; Qingjie WU ; Fang LIU ; Zhongtuo HUA ; Sicheng ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):64-69
OBJECTIVE:
To compare the effectiveness of ultrasound-guided closed reduction with Kirschner wire fixation and open reduction with Kirschner wire fixation in the treatment of humeral lateral condyle fracture (HLCF) in children.
METHODS:
A clinical data of 53 children with HLCF admitted between May 2020 and April 2023 and met selective criteria was retrospectively analyzed. Of these, 25 cases were managed with closed reduction and Kirschner wire fixation under ultrasound guidance (closed group), while 28 cases underwent open reduction and Kirschner wire fixation (open group). There was no significant difference between the two groups in terms of gender, age, cause of injury, fracture side, fracture classification, and time from injury to operation ( P>0.05). The following variables were recorded and compared between the two groups: operation time, intraoperative fluoroscopy frequency, fracture healing time, incidence of complications, and the Flynn elbow function score at last follow-up.
RESULTS:
In the closed group, the fractures were successfully reduced under ultrasound guidance, with no nerve damage reported in either group. The operation time and intraoperative fluoroscopy frequency were significantly less in the closed group than in the open group ( P<0.05). One case of infection (Kirschner wire irritation) was observed in the closed group, while 3 cases in the open group (2 of Kirschner wire irritation and 1 of incision infection). However, the difference in the incidence of infection between the two groups was not significant ( P>0.05). All patients in both groups were followed up 6-18 months (mean, 10.2 months). X-ray examinations confirmed that fractures had healed in both groups, with no significant difference in healing time ( P>0.05). During follow-up, 5 cases of lateral humeral process formation were observed in the closed group, compared to 12 cases in the open group, although this difference was not significant ( P>0.05). At last follow-up, the excellent and good rate of elbow joint function was evaluated as 96.0% (24/25) in the closed group and 92.9% (26/28) in the open group according to the Flynn scoring criteria, with no significant difference between the two groups ( P>0.05). Both groups showed no occurrence of ossifying myositis or elbow internal/external rotation.
CONCLUSION
The effectiveness of ultrasound-guided closed reduction and Kirschner wire fixation in the treatment of HLCF in children is comparable to open reduction and Kirschner wire fixation, but the former can reduce operation time and intraoperative fluoroscopy frequency, and obtain lower the incidence of complications.
Humans
;
Humeral Fractures/diagnostic imaging*
;
Bone Wires
;
Male
;
Female
;
Child
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Treatment Outcome
;
Child, Preschool
;
Open Fracture Reduction/methods*
;
Fracture Healing
;
Elbow Joint/surgery*
;
Adolescent
;
Closed Fracture Reduction/methods*
;
Fluoroscopy
;
Operative Time

Result Analysis