1.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
2.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
3.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
4.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
5.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
7.Oxidative hemolytic crises in a dog due to fragrance products: clinical insights and treatment approaches
Sully LEE ; Kyoung-Won SEO ; Urs GIGER ; Min-Ok RYU
Journal of Veterinary Science 2024;25(5):e64-
and Relevance: Recurring oxidative hemolytic crises should raise suspicions of environmental toxicity, which, although harmless in small quantities to humans, can be devastating to small-breed dogs. In addition to removing the causative agents, methylene blue and other antioxidants, along with HBO, may be beneficial in the acute management of oxidative hemolytic anemia.
8.A case of successful pediatric heat stroke treatment using normothermic targeted temperature management
Seungjin LEE ; Geun Seop SHIN ; Sang-I KONG ; Yoseop WON ; Young Dai KWON ; Jung Min YOON ; Kyoung Ok KO ; In Goo LEE ; Jun Suk OH
Pediatric Emergency Medicine Journal 2024;11(4):179-184
This case report describes a successful use of normothermic targeted temperature management (TTM) for the treatment of a 14-year-old girl with exertional heat stroke. Upon hospitalization, she exhibited a 40.5 ℃ core temperature and multiorgan failure. We immediately applied the TTM, targeting a range of 36-37 ℃. Her condition improved rapidly, with vital signs stabilized and consciousness fully regained by day 3. She experienced a bimodal pattern of rhabdomyolysis during recovery, which was managed without further complications. No neurological sequelae were observed, and all laboratory parameters were normalized before discharge on day 10. This case suggests the potential efficacy of normothermic TTM in pediatric heat stroke.
9.Erratum: Correction of Affiliations in the Article “Clinical Characteristics and Treatment Outcomes in Children, Adolescents, and Young-adults with Hodgkin's Lymphoma: a KPHOG Lymphoma Working-party, Multicenter, Retrospective Study”
Jae Min LEE ; Jung Yoon CHOI ; Kyung Taek HONG ; Hyoung Jin KANG ; Hee Young SHIN ; Hee Jo BAEK ; Hoon KOOK ; Seongkoo KIM ; Jae Wook LEE ; Nack-Gyun CHUNG ; Bin CHO ; Seok-Goo CHO ; Kyung Mi PARK ; Eu Jeen YANG ; Young Tak LIM ; Jin Kyung SUH ; Sung Han KANG ; Hyery KIM ; Kyung-Nam KOH ; Ho Joon IM ; Jong Jin SEO ; Hee Won CHO ; Hee Young JU ; Ji Won LEE ; Keon Hee YOO ; Ki Woong SUNG ; Hong Hoe KOO ; Kyung Duk PARK ; Jeong Ok HAH ; Min Kyoung KIM ; Jung Woo HAN ; Seung Min HAHN ; Chuhl Joo LYU ; Ye Jee SHIM ; Heung Sik KIM ; Young Rok DO ; Jae Won YOO ; Yeon Jung LIM ; In-Sang JEON ; Hee won CHUEH ; Sung Yong OH ; Hyoung Soo CHOI ; Jun Eun PARK ; Jun Ah LEE ; Hyeon Jin PARK ; Byung-Kiu PARK ; Soon Ki KIM ; Jae Young LIM ; Eun Sil PARK ; Sang Kyu PARK ; Eun Jin CHOI ; Young Bae CHOI ; Jong Hyung YOON ;
Journal of Korean Medical Science 2021;36(4):e37-
10.A Comparison of the Effects between Eye-Mask and Light-Off Conditions on Psychiatric Patient Sleep
Juyong SHIN ; Kyoung-Ok LIM ; Seongnam CHO ; Soyeong JANG ; Seung-Min CHA ; Songyi HAN ; Moojin KIM
Sleep Medicine and Psychophysiology 2021;28(1):27-33
Objectives:
The purpose of this study is to investigate the difference in the effects of eye-mask and light-off on sleep status according to a commercial fitness tracker and a sleep diary of psychiatric in-patients in correctional facilities where nocturnal light is compulsory.
Methods:
This study was conducted over 3 consecutive nights. In-patients of the National Forensic Psychiatric Hospital (n = 29) were assigned random subject numbers and slept as usual in the light-on condition on the first night. The subjects slept with eye-masks in the light-on condition on another night and without an eye-mask in the light-off condition on the other night. Subjects were asked to sleep wearing a commercial fitness tracker and to keep a sleep diary. The order of these changes in bedroom lighting condition on the second and third nights was assigned randomly to participants.
Results:
In comparison of the sleep variables between the light-on condition and the eye-mask condition, the Wakefullness After Sleep Onset (WASO) was shorter and sleep satisfaction was higher in the latter.(respectively, Z = 3.66, p < 0.017 ; Z = 2.69, p < 0.017) In comparison of the sleep variables between the light-on and light-off conditions, the WASO was shorter and sleep efficiency and sleep satisfaction were higher in the latter (respectively, Z = 2.40, p < 0.017 ; Z = 3.02, p < 0.017 ; Z = 3.88, p < 0.017). However, there were no differences in the sleep variables between the eye-mask condition and the light-off condition.
Conclusion
Subjective improvements in sleep variables were noted in sleep diaries of institutionalized psychiatric patients under either the ‘eye-mask’ or ‘light-off’ condition. However, there were no significant differences between the ‘eye-mask’ and ‘light-off’ conditions. Therefore, we suggest that psychiatric patients in correctional facilities use eye-masks when sleeping.

Result Analysis
Print
Save
E-mail