1.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
2.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
3.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
4.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
5.Evaluating Rituximab Failure Rates in Neuromyelitis Optica Spectrum Disorder: A Nationwide Real-World Study From South Korea
Su-Hyun KIM ; Ju-Hong MIN ; Sung-Min KIM ; Eun-Jae LEE ; Young-Min LIM ; Ha Young SHIN ; Young Nam KWON ; Eunhee SOHN ; Sooyoung KIM ; Min Su PARK ; Tai-Seung NAM ; Byeol-A YOON ; Jong Kuk KIM ; Kyong Jin SHIN ; Yoo Hwan KIM ; Jin Myoung SEOK ; Jeong Bin BONG ; Sohyeon KIM ; Hung Youl SEOK ; Sun-Young OH ; Ohyun KWON ; Sunyoung KIM ; Sukyoon LEE ; Nam-Hee KIM ; Eun Bin CHO ; Sa-Yoon KANG ; Seong-il OH ; Jong Seok BAE ; Suk-Won AHN ; Ki Hoon KIM ; You-Ri KANG ; Woohee JU ; Seung Ho CHOO ; Yeon Hak CHUNG ; Jae-Won HYUN ; Ho Jin KIM
Journal of Clinical Neurology 2025;21(2):131-136
Background:
and Purpose Treatments for neuromyelitis optica spectrum disorder (NMOSD) such as eculizumab, ravulizumab, satralizumab, and inebilizumab have significantly advanced relapse prevention, but they remain expensive. Rituximab is an off-label yet popular alternative that offers a cost-effective solution, but its real-world efficacy needs better quantification for guiding the application of newer approved NMOSD treatments (ANTs). This study aimed to determine real-world rituximab failure rates to anticipate the demand for ANTs and aid in resource allocation.
Methods:
We conducted a nationwide retrospective study involving 605 aquaporin-4-antibody-positive NMOSD patients from 22 centers in South Korea that assessed the efficacy and safety of rituximab over a median follow-up of 47 months.
Results:
The 605 patients treated with rituximab included 525 (87%) who received continuous therapy throughout the follow-up period (median=47 months, interquartile range=15–87 months). During this period, 117 patients (19%) experienced at least 1 relapse. Notably, 68 of these patients (11% of the total cohort) experienced multiple relapses or at least 1 severe relapse.Additionally, 2% of the patients discontinued rituximab due to adverse events, which included severe infusion reactions, neutropenia, and infections.
Conclusions
This study has confirmed the efficacy of rituximab in treating NMOSD, as evidenced by an 87% continuation rate among patients over a 4-year follow-up period. Nevertheless, the occurrence of at least one relapse in 19% of the cohort, including 11% who experienced multiple or severe relapses, and a 2% discontinuation rate due to adverse events highlight the urgent need for alternative therapeutic options.
6.Evaluating Rituximab Failure Rates in Neuromyelitis Optica Spectrum Disorder: A Nationwide Real-World Study From South Korea
Su-Hyun KIM ; Ju-Hong MIN ; Sung-Min KIM ; Eun-Jae LEE ; Young-Min LIM ; Ha Young SHIN ; Young Nam KWON ; Eunhee SOHN ; Sooyoung KIM ; Min Su PARK ; Tai-Seung NAM ; Byeol-A YOON ; Jong Kuk KIM ; Kyong Jin SHIN ; Yoo Hwan KIM ; Jin Myoung SEOK ; Jeong Bin BONG ; Sohyeon KIM ; Hung Youl SEOK ; Sun-Young OH ; Ohyun KWON ; Sunyoung KIM ; Sukyoon LEE ; Nam-Hee KIM ; Eun Bin CHO ; Sa-Yoon KANG ; Seong-il OH ; Jong Seok BAE ; Suk-Won AHN ; Ki Hoon KIM ; You-Ri KANG ; Woohee JU ; Seung Ho CHOO ; Yeon Hak CHUNG ; Jae-Won HYUN ; Ho Jin KIM
Journal of Clinical Neurology 2025;21(2):131-136
Background:
and Purpose Treatments for neuromyelitis optica spectrum disorder (NMOSD) such as eculizumab, ravulizumab, satralizumab, and inebilizumab have significantly advanced relapse prevention, but they remain expensive. Rituximab is an off-label yet popular alternative that offers a cost-effective solution, but its real-world efficacy needs better quantification for guiding the application of newer approved NMOSD treatments (ANTs). This study aimed to determine real-world rituximab failure rates to anticipate the demand for ANTs and aid in resource allocation.
Methods:
We conducted a nationwide retrospective study involving 605 aquaporin-4-antibody-positive NMOSD patients from 22 centers in South Korea that assessed the efficacy and safety of rituximab over a median follow-up of 47 months.
Results:
The 605 patients treated with rituximab included 525 (87%) who received continuous therapy throughout the follow-up period (median=47 months, interquartile range=15–87 months). During this period, 117 patients (19%) experienced at least 1 relapse. Notably, 68 of these patients (11% of the total cohort) experienced multiple relapses or at least 1 severe relapse.Additionally, 2% of the patients discontinued rituximab due to adverse events, which included severe infusion reactions, neutropenia, and infections.
Conclusions
This study has confirmed the efficacy of rituximab in treating NMOSD, as evidenced by an 87% continuation rate among patients over a 4-year follow-up period. Nevertheless, the occurrence of at least one relapse in 19% of the cohort, including 11% who experienced multiple or severe relapses, and a 2% discontinuation rate due to adverse events highlight the urgent need for alternative therapeutic options.
7.Evaluating Rituximab Failure Rates in Neuromyelitis Optica Spectrum Disorder: A Nationwide Real-World Study From South Korea
Su-Hyun KIM ; Ju-Hong MIN ; Sung-Min KIM ; Eun-Jae LEE ; Young-Min LIM ; Ha Young SHIN ; Young Nam KWON ; Eunhee SOHN ; Sooyoung KIM ; Min Su PARK ; Tai-Seung NAM ; Byeol-A YOON ; Jong Kuk KIM ; Kyong Jin SHIN ; Yoo Hwan KIM ; Jin Myoung SEOK ; Jeong Bin BONG ; Sohyeon KIM ; Hung Youl SEOK ; Sun-Young OH ; Ohyun KWON ; Sunyoung KIM ; Sukyoon LEE ; Nam-Hee KIM ; Eun Bin CHO ; Sa-Yoon KANG ; Seong-il OH ; Jong Seok BAE ; Suk-Won AHN ; Ki Hoon KIM ; You-Ri KANG ; Woohee JU ; Seung Ho CHOO ; Yeon Hak CHUNG ; Jae-Won HYUN ; Ho Jin KIM
Journal of Clinical Neurology 2025;21(2):131-136
Background:
and Purpose Treatments for neuromyelitis optica spectrum disorder (NMOSD) such as eculizumab, ravulizumab, satralizumab, and inebilizumab have significantly advanced relapse prevention, but they remain expensive. Rituximab is an off-label yet popular alternative that offers a cost-effective solution, but its real-world efficacy needs better quantification for guiding the application of newer approved NMOSD treatments (ANTs). This study aimed to determine real-world rituximab failure rates to anticipate the demand for ANTs and aid in resource allocation.
Methods:
We conducted a nationwide retrospective study involving 605 aquaporin-4-antibody-positive NMOSD patients from 22 centers in South Korea that assessed the efficacy and safety of rituximab over a median follow-up of 47 months.
Results:
The 605 patients treated with rituximab included 525 (87%) who received continuous therapy throughout the follow-up period (median=47 months, interquartile range=15–87 months). During this period, 117 patients (19%) experienced at least 1 relapse. Notably, 68 of these patients (11% of the total cohort) experienced multiple relapses or at least 1 severe relapse.Additionally, 2% of the patients discontinued rituximab due to adverse events, which included severe infusion reactions, neutropenia, and infections.
Conclusions
This study has confirmed the efficacy of rituximab in treating NMOSD, as evidenced by an 87% continuation rate among patients over a 4-year follow-up period. Nevertheless, the occurrence of at least one relapse in 19% of the cohort, including 11% who experienced multiple or severe relapses, and a 2% discontinuation rate due to adverse events highlight the urgent need for alternative therapeutic options.
8.Perioperative nutritional practice of surgeons in Korea: a survey study
Ji-Hyeon PARK ; Mi Ran JUNG ; Sang Hyun KIM ; Hongbeom KIM ; Gyeongsil LEE ; Jae-Seok MIN ; Heung-Kwon OH ; Jung Hoon BAE ; Yoona CHUNG ; Dong-Seok HAN ; Seung Wan RYU ;
Annals of Clinical Nutrition and Metabolism 2024;16(3):134-148
Purpose:
Enhanced recovery after surgery (ERAS) protocols advocate reduced fasting and early nutrition to improve recovery in surgical patients. However, data on ERAS implementation among Korean surgeons performing major abdominal surgeries remain sparse.
Methods:
A survey conducted by the External Relation Committee of the Korean Society of Surgical Metabolism and Nutrition assessed perioperative nutritional practices among 389 Korean general surgeons from February to September 2023. The survey covered preoperative fasting, carbohydrate drinks, nasogastric tube use, postoperative dietary progression, parenteral nutrition (PN), and oral supplements, yielding 551 responses stratified by specialty.
Results:
More than 80% of respondents practiced “midnight NPO (Nil Per Os)” fasting, often at the anesthesiology department’s request, while 70%–80% reported no use of preoperative carbohydrate drinks. Most surgeons began dietary progression with water on postoperative day one, advancing to a liquid or soft diet by day two. PN was routinely prescribed by 49% of respondents, with a common dosage of 1,000–1,500 kcal/d. Oral supplements were selectively provided, with 21% of surgeons prescribing them universally.
Conclusion
The results reveal significant variability in perioperative nutrition practices across Korean surgical specialties, with many adhering to traditional practices despite ERAS guidelines. These findings highlight a need for standardized guidelines in Korea to optimize perioperative nutritional support and improve patient recovery outcomes following major abdominal surgeries.
9.Guideline for Minimizing Radiation Exposure of Interventionalists during Fluoroscopy-guided Interventional Procedures
Il Sang SHIN ; Yun Nah LEE ; Jun Kyu LEE ; Joo Seong KIM ; Sung Bum KIM ; Jiyoung KEUM ; Chang Hoon OH ; Kang Won LEE ; Joowon CHUNG ; Lyo Min KWON ; Nam Hee KIM ; Sang Soo LEE ; Byoung Kwan SON ; Miyoung CHOI
The Korean Journal of Gastroenterology 2024;84(6):251-264
As fluoroscopy-guided interventional procedures gain popularity, the associated health threats from radiation exposure to interventionalists during these procedures are increasing. Therefore, an understanding of the potential risks of radiation and careful consideration on minimizing exposure to radiation during the procedures are of paramount importance. The Korean Pancreatobiliary Association has developed a clinical practice guideline to minimize radiation exposure during fluoroscopy-guided interventional procedures. This guideline provides recommendations to deal with the risk of radiation exposure to interventionalists who perform fluoroscopy-guided procedures, and emphasizes the importance of proper and practical approaches to avoid unnecessary radiation exposure.
10.Guideline for Minimizing Radiation Exposure of Interventionalists during Fluoroscopy-guided Interventional Procedures
Il Sang SHIN ; Yun Nah LEE ; Jun Kyu LEE ; Joo Seong KIM ; Sung Bum KIM ; Jiyoung KEUM ; Chang Hoon OH ; Kang Won LEE ; Joowon CHUNG ; Lyo Min KWON ; Nam Hee KIM ; Sang Soo LEE ; Byoung Kwan SON ; Miyoung CHOI
The Korean Journal of Gastroenterology 2024;84(6):251-264
As fluoroscopy-guided interventional procedures gain popularity, the associated health threats from radiation exposure to interventionalists during these procedures are increasing. Therefore, an understanding of the potential risks of radiation and careful consideration on minimizing exposure to radiation during the procedures are of paramount importance. The Korean Pancreatobiliary Association has developed a clinical practice guideline to minimize radiation exposure during fluoroscopy-guided interventional procedures. This guideline provides recommendations to deal with the risk of radiation exposure to interventionalists who perform fluoroscopy-guided procedures, and emphasizes the importance of proper and practical approaches to avoid unnecessary radiation exposure.

Result Analysis
Print
Save
E-mail