2.Correlation of color vision impairment and capillary blood glucose in diabetic patients without retinopathy vs. in those with mild non-proliferative diabetic retinopathy
Karen B. Reyes ; Margarita Justine O. Bondoc-Hermosa ; Maria Cecilia P. Garcia-Arenal ; Rachelle C. Perez
Philippine Journal of Ophthalmology 2025;50(2):93-98
OBJECTIVE
To compare the frequency and severity of color vision defects between diabetes mellitus (DM) patients without retinopathy and those with mild non-proliferative diabetic retinopathy (NPDR), and to evaluate the relationship between these color vision defects and capillary blood glucose (CBG) levels.
METHODSThis was a cross-sectional, hospital-based study conducted over a seven-month period at the Ophthalmology Outpatient Department of Cardinal Santos Medical Center. Thirty-five (35) DM patients (70 eyes) aged 50 to 75 years with best-corrected visual acuity of ≥20/50 and no more than mild NPDR were included. Patients with moderate or severe NPDR, macular edema, optic nerve pathology, or significant cataracts were excluded. All participants underwent visual acuity testing, fundus examination, and color vision assessment using the Ishihara pseudoisochromatic plates and Farnsworth D-15 tests conducted under standardized lighting conditions. CBG was measured using the finger-prick method. Main outcome measures included the proportion and type of color vision defects, their association with DR classification, and CBG levels. Statistical analyses included descriptive statistics, the Fisher exact test, the Mann-Whitney U test for the Farnsworth D-15 Color Confusion Index (CCI), and Spearman correlation between CBG and CCI.
RESULTSTritan-type defects were the most common, accounting for 36.2%. Color vision defects were observed in 91.3% (64 eyes) of patients with no DR, while defects were seen in all eyes (100%) with mild NPDR (5 eyes). However, this difference was not statistically significant (p = 1.000). There was no significant correlation between CBG levels and color vision scores. Mean CCI scores were similar between groups (p = 0.394), indicating no substantial difference in defect severity.
CONCLUSIONSColor vision defects may be more prevalent in early NPDR compared to no DR, but this difference was not significant in this sample. No correlation was found between CBG levels and color vision performance. Color vision testing may serve as a useful adjunctive screening tool for early diabetic retinal changes; however, further studies with larger sample sizes are necessary.
Human ; Color Vision Defects ; Diabetic Retinopathy
3.The Role of Prefrontal and Posterior Parietal Cortex in Generating Multiple Step Saccades.
Wenbo MA ; Zhaohuan DING ; Leixiao FENG ; Xiaoli LI ; Mingsha ZHANG
Neuroscience Bulletin 2025;41(8):1418-1428
While multiple step saccades (MSS) are occasionally reported in the healthy population, they are more evident in patients with Parkinson's disease (PD). Therefore, MSS has been suggested as a biological marker for the diagnosis of PD. However, the lack of clarity on the neural mechanism underlying the generation of MSS largely impedes their application in the clinic. We have proposed recently that MSS are triggered by the discrepancy between desired and executed saccades. Accordingly, brain regions involved in saccadic planning and execution might play a role in the generation of MSS. To test this hypothesis, we explored the role of the prefrontal (PFC) and posterior parietal cortex (PPC) in generating MSS by conducting two experiments: electroencephalographic recording and single-pulse transcranial magnetic stimulation in the PFC or PPC of humans while participants were performing a gap saccade task. We found that the PFC and PPC are involved in the generation of MSS.
Humans
;
Parietal Lobe/physiology*
;
Saccades/physiology*
;
Prefrontal Cortex/physiology*
;
Male
;
Transcranial Magnetic Stimulation
;
Female
;
Electroencephalography
;
Adult
;
Young Adult
4.Transcranial temporal interference stimulation precisely targets deep brain regions to regulate eye movements.
Mo WANG ; Sixian SONG ; Dan LI ; Guangchao ZHAO ; Yu LUO ; Yi TIAN ; Jiajia ZHANG ; Quanying LIU ; Pengfei WEI
Neuroscience Bulletin 2025;41(8):1390-1402
Transcranial temporal interference stimulation (tTIS) is a novel non-invasive neuromodulation technique with the potential to precisely target deep brain structures. This study explores the neural and behavioral effects of tTIS on the superior colliculus (SC), a region involved in eye movement control, in mice. Computational modeling revealed that tTIS delivers more focused stimulation to the SC than traditional transcranial alternating current stimulation. In vivo experiments, including Ca2+ signal recordings and eye movement tracking, showed that tTIS effectively modulates SC neural activity and induces eye movements. A significant correlation was found between stimulation frequency and saccade frequency, suggesting direct tTIS-induced modulation of SC activity. These results demonstrate the precision of tTIS in targeting deep brain regions and regulating eye movements, highlighting its potential for neuroscientific research and therapeutic applications.
Animals
;
Superior Colliculi/physiology*
;
Transcranial Direct Current Stimulation/methods*
;
Eye Movements/physiology*
;
Male
;
Mice
;
Mice, Inbred C57BL
5.AQMFB-DWT: A Preprocessing Technique for Removing Blink Artifacts Before Extracting Pain-evoked Potential EEG.
Wenjia GAO ; Dan LIU ; Qisong WANG ; Yongping ZHAO ; Jinwei SUN
Neuroscience Bulletin 2025;41(12):2285-2295
The pain-evoked potential electroencephalogram (EEG) is an effective electrophysiological indicator for pain assessment, yet its extraction is challenging due to interference from background activity and involuntary blinks. Although existing blink artifact-removal methods show efficacy, they face limitations such as the need for reference signals, neglect of individual differences, and reliance on user input, hindering their practical application in clinical pain assessments. In this paper, we propose a novel framework applying adaptive quadrature mirror filter banks (AQMFB) with discrete wavelet transform (DWT) to remove blink artifacts in pain EEG. Unlike traditional DWT methods that apply fixed wavelets across subjects, our method adapts wavelet construction based on the characteristics of EEG. Experimental results demonstrate that AQMFB-DWT outperforms four leading methods in removing blink artifacts with minimal distortion of pain information, all within an acceptable processing time. This technique is a valuable preprocessing step for enhancing the extraction of pain-evoked potentials.
Humans
;
Artifacts
;
Blinking/physiology*
;
Electroencephalography/methods*
;
Pain/diagnosis*
;
Male
;
Wavelet Analysis
;
Adult
;
Female
;
Evoked Potentials/physiology*
;
Young Adult
;
Brain/physiopathology*
;
Pain Measurement/methods*
;
Signal Processing, Computer-Assisted
6.Recent Advances in the Molecular Mechanisms of Ocular Dominance Plasticity in the Visual Cortex.
Yanglin QIN ; Wei WANG ; Yu GU ; Xuefeng SHI
Neuroscience Bulletin 2025;41(9):1645-1655
The visual cortex is an essential part of the brain for processing visual information. It exhibits structural and functional plasticity, which is crucial for adapting to complex visual environments. The quintessential manifestation of visual cortical plasticity is ocular dominance plasticity during the critical period, which involves numerous cellular and molecular events. While previous studies have emphasized the role of visual cortical neurons and their associated functional molecules in visual plasticity, recent findings have revealed that structural factors such as the extracellular matrix and glia are also involved. Investigating how these molecules interact to form a complex network that facilitates plasticity in the visual cortex is crucial to our understanding of the development of the visual system and the advancement of therapeutic strategies for visual disorders like amblyopia.
Neuronal Plasticity/physiology*
;
Dominance, Ocular/physiology*
;
Visual Cortex/physiology*
;
Humans
;
Animals
;
Neurons/physiology*
7.Dynamic continuous emotion recognition method based on electroencephalography and eye movement signals.
Yangmeng ZOU ; Lilin JIE ; Mingxun WANG ; Yong LIU ; Junhua LI
Journal of Biomedical Engineering 2025;42(1):32-41
Existing emotion recognition research is typically limited to static laboratory settings and has not fully handle the changes in emotional states in dynamic scenarios. To address this problem, this paper proposes a method for dynamic continuous emotion recognition based on electroencephalography (EEG) and eye movement signals. Firstly, an experimental paradigm was designed to cover six dynamic emotion transition scenarios including happy to calm, calm to happy, sad to calm, calm to sad, nervous to calm, and calm to nervous. EEG and eye movement data were collected simultaneously from 20 subjects to fill the gap in current multimodal dynamic continuous emotion datasets. In the valence-arousal two-dimensional space, emotion ratings for stimulus videos were performed every five seconds on a scale of 1 to 9, and dynamic continuous emotion labels were normalized. Subsequently, frequency band features were extracted from the preprocessed EEG and eye movement data. A cascade feature fusion approach was used to effectively combine EEG and eye movement features, generating an information-rich multimodal feature vector. This feature vector was input into four regression models including support vector regression with radial basis function kernel, decision tree, random forest, and K-nearest neighbors, to develop the dynamic continuous emotion recognition model. The results showed that the proposed method achieved the lowest mean square error for valence and arousal across the six dynamic continuous emotions. This approach can accurately recognize various emotion transitions in dynamic situations, offering higher accuracy and robustness compared to using either EEG or eye movement signals alone, making it well-suited for practical applications.
Humans
;
Electroencephalography/methods*
;
Emotions/physiology*
;
Eye Movements/physiology*
;
Signal Processing, Computer-Assisted
;
Support Vector Machine
;
Algorithms
8.A portable steady-state visual evoked potential brain-computer interface system for smart healthcare.
Yisen ZHU ; Zhouyu JI ; Shuran LI ; Haicheng WANG ; Yunfa FU ; Hongtao WANG
Journal of Biomedical Engineering 2025;42(3):455-463
This paper realized a portable brain-computer interface (BCI) system tailored for smart healthcare. Through the decoding of steady-state visual evoked potential (SSVEP), this system can rapidly and accurately identify the intentions of subjects, thereby meeting the practical demands of daily medical scenarios. Firstly, an SSVEP stimulation interface and an electroencephalogram (EEG) signal acquisition software were designed, which enable the system to execute multi-target and multi-task operations while also incorporating data visualization functionality. Secondly, the EEG signals recorded from the occipital region were decomposed into eight sub-frequency bands using filter bank canonical correlation analysis (FBCCA). Subsequently, the similarity between each sub-band signal and the reference signals was computed to achieve efficient SSVEP decoding. Finally, 15 subjects were recruited to participate in the online evaluation of the system. The experimental results indicated that in real-world scenarios, the system achieved an average accuracy of 85.19% in identifying the intentions of the subjects, and an information transfer rate (ITR) of 37.52 bit/min. This system was awarded third prize in the Visual BCI Innovation Application Development competition at the 2024 World Robot Contest, validating its effectiveness. In conclusion, this study has developed a portable, multifunctional SSVEP online decoding system, providing an effective approach for human-computer interaction in smart healthcare.
Brain-Computer Interfaces
;
Humans
;
Evoked Potentials, Visual/physiology*
;
Electroencephalography
;
Signal Processing, Computer-Assisted
;
Software
;
Adult
;
Male
9.Performance evaluation of a wearable steady-state visual evoked potential based brain-computer interface in real-life scenario.
Xiaodong LI ; Xiang CAO ; Junlin WANG ; Weijie ZHU ; Yong HUANG ; Feng WAN ; Yong HU
Journal of Biomedical Engineering 2025;42(3):464-472
Brain-computer interface (BCI) has high application value in the field of healthcare. However, in practical clinical applications, convenience and system performance should be considered in the use of BCI. Wearable BCIs are generally with high convenience, but their performance in real-life scenario needs to be evaluated. This study proposed a wearable steady-state visual evoked potential (SSVEP)-based BCI system equipped with a small-sized electroencephalogram (EEG) collector and a high-performance training-free decoding algorithm. Ten healthy subjects participated in the test of BCI system under simplified experimental preparation. The results showed that the average classification accuracy of this BCI was 94.10% for 40 targets, and there was no significant difference compared to the dataset collected under the laboratory condition. The system achieved a maximum information transfer rate (ITR) of 115.25 bit/min with 8-channel signal and 98.49 bit/min with 4-channel signal, indicating that the 4-channel solution can be used as an option for the few-channel BCI. Overall, this wearable SSVEP-BCI can achieve good performance in real-life scenario, which helps to promote BCI technology in clinical practice.
Brain-Computer Interfaces
;
Humans
;
Evoked Potentials, Visual/physiology*
;
Electroencephalography
;
Wearable Electronic Devices
;
Algorithms
;
Signal Processing, Computer-Assisted
;
Adult
;
Male
10.Technical maturity and bubble risks of brain-computer interface (BCI): Considerations from research to industrial translation.
Journal of Biomedical Engineering 2025;42(4):651-659
Brain-computer interface (BCI) technology faces structural risks due to a misalignment between its technological maturity and industrialization expectations. This study used the Technology Readiness Level (TRL) framework to assess the status of major BCI paradigms-such as steady-state visual evoked potential (SSVEP), motor imagery, and P300-and found that they predominantly remained at TRL4 to TRL6, with few stable applications reaching TRL9. The analysis identified four interrelated sources of bubble risk: overly broad definitions of BCI, excessive focus on decoding performance, asynchronous translational progress, and imprecise terminology usage. These distortions have contributed to the misallocation of research resources and public misunderstanding. To foster the sustainable development of BCI, this paper advocated the establishment of a standardized TRL evaluation system, clearer terminological boundaries, stronger support for fundamental research, enhanced ethical oversight, and the implementation of inclusive and diversified governance mechanisms.
Brain-Computer Interfaces
;
Humans
;
Evoked Potentials, Visual
;
Electroencephalography
;
Event-Related Potentials, P300


Result Analysis
Print
Save
E-mail