1.Overview of Diagnosis,Treatment and Mechanism Research of Functional Dyspepsia by Integrated Traditional Chinese and Western Medicine
Shengsheng ZHANG ; Zhaohong SHI ; Xiaofang LU ; Luqing ZHAO ; Danyan LI ; Shu ZHANG ; Lu ZHAO ; Yudi ZHUO ; Nian WANG ; Fan LIU ; Shuangyi LI ; Xudong TANG
Journal of Traditional Chinese Medicine 2026;67(4):397-403
Functional dyspepsia (FD) is a prioritized disease category where traditional Chinese medicine (TCM) demonstrates distinct therapeutic advantages. The current western medicine treatment for FD is mainly based on proton pump inhibitors and prokinetic agents, with digestive enzymes, probiotics and antidepressants serving as adjuvant medication, yet such therapies still have certain limitations. TCM treatment for FD includes oral administration of Chinese herbal formulas and Chinese patent medicines, as well as external TCM therapies such as acupuncture and moxibustion, acupoint application, hot medicinal compress therapy, rubbing with ointment, medicinal iontophoresis, auricular acupoint therapy and tui na (Chinese medical massage). The combined treatment of FD with integrated TCM and western medicine can significantly improve clinical effectiveness and reduce adverse reactions. The common mechanisms underlying the therapeutic effects of both TCM and western medicine revolve around the core pathological processes of FD, mainly focusing on restoring gastrointestinal motility, regulating the levels of brain-gut peptides, modulating intestinal microecology, and ameliorating inflammatory status. The differential mechanisms lie in the precise targeting feature of western medicine versus the holistic-regulating and multi-target characteristics of TCM, and the two approaches exert a synergistic effect to enhance efficacy. This paper proposes to leverage the advantages of TCM in holistic regulation and the strengths of western medicine in targeted treatment, so as to provide personalized and comprehensive treatment regimens for FD patients.
2.Assessing High-density Y-SNP Panels for Paternal Haplogroup Assignment in Forensic Practice
De-Qin ZHANG ; Chun-Nian WANG ; Lin-Lin LOU ; Meng NI ; Jing GAO ; Jiang HUANG ; Li JIANG
Progress in Biochemistry and Biophysics 2026;53(2):458-469
ObjectiveThe accuracy of Y-chromosome haplogroup assignment is crucial for tracing paternal lineage in male samples. With the advancement of high-throughput sequencing technologies, high-density Y-SNP genotyping from whole-genome or array-based data has become a standard method for determiningY-chromosome haplogroups. This study systematically evaluated the performance of 4 commonly used high-density SNP genotyping systems—namely, the Global Screening Array (GSA), Chinese Genotyping Array (CGA), Affymetrix array, and the 1240K capture panel—for haplogroup assignment. This work provides a reference for data comparison across different systems. MethodsWe extracted genotype data for the 4 Y-SNP panels from 30× whole-genome sequencing (WGS) data of 1 590 male samples from the 1000 Genomes Project. Additionally, GSA array genotype data from 384 relative pairs (spanning 1st- to 12th-degree relationships) from 109 Chinese Han families were collected. Haplogroup assignment was performed using Y-LineageTracker v1.3.0 software. We assessed the concordance and resolution of haplogroup assignments between the four Y-SNP panels and the WGS data. The consistency and resolution of haplogroup assignments were also evaluated for both the 1000 Genomes Project samples and the 109 family samples collected in this study. Furthermore, the impact of varying numbers of Y-SNPs on haplogroup assignment was examined. ResultsThe GSA and CGA panels demonstrated superior resolution and discrimination of haplogroup subclades compared with the other two panels. The haplogroup assignments from the GSA, CGA, and 1240K panels showed high concordance with WGS data, with consistency rates exceeding 88.70%, whereas the Affymetrix platform exhibited a significantly lower consistency rate of 61.89%. Specifically, the GSA and CGA panels consistently demonstrated superior performance compared with the other two panels in the assignment of haplogroups O-M175 and H-L901, achieving complete concordance (100%) for both haplogroups. In contrast, the Affymetrix panel erroneously assigned all individuals belonging to haplogroup O-M175 to haplogroup K2-M526. Furthermore, its accuracy for haplogroup H-L901 was exceedingly low, at merely 1.41%. This poor performance was characterized by the misassignment of 98.59% of H-L901 samples—specifically, 1.41% to J-M304 and a predominant 97.18% to F-M89. For haplogroup R-M207, all four panels exhibited uniformly high levels of consistency, with concordance values exceeding 94.00%. Notably, for haplogroup E-M96, the 1240K and Affymetrix panels outperformed the GSA and CGA panels in terms of concordance, representing the first instance in which these two panels surpassed the latter. Conversely, for haplogroups J-M304, Q-M242, and I-M170, all 4 panels showed relatively elevated misclassification rates, with the Affymetrix array demonstrating the poorest overall performance. None of the four panels showed any discordant haplogroup assignments among the familial relative pairs analyzed. A positive correlation was observed between the number of Y-SNPs (ranging from 1 000 to 10 000) and classification consistency; however, classification consistency plateaued when the number of Y-SNPs exceeded 10 000. Furthermore, a random sampling analysis conducted on the GSA and CGA panels demonstrated that the haplogroup misclassification rate exhibited negligible fluctuation across the Y-SNP range of 500 to 1 000. Conversely, a marked enhancement in classification consistency was observed as the number of markers increased from 1 000 to 5 000, ultimately reaching a plateau within the interval of 5 000 to 8 000 markers. ConclusionThese findings indicate that the GSA and CGA panels provide high resolution and concordance, delivering reliable Y-haplogroup assignment for forensic investigations.
3.Assessing High-density Y-SNP Panels for Paternal Haplogroup Assignment in Forensic Practice
De-Qin ZHANG ; Chun-Nian WANG ; Lin-Lin LOU ; Meng NI ; Jing GAO ; Jiang HUANG ; Li JIANG
Progress in Biochemistry and Biophysics 2026;53(2):458-469
ObjectiveThe accuracy of Y-chromosome haplogroup assignment is crucial for tracing paternal lineage in male samples. With the advancement of high-throughput sequencing technologies, high-density Y-SNP genotyping from whole-genome or array-based data has become a standard method for determiningY-chromosome haplogroups. This study systematically evaluated the performance of 4 commonly used high-density SNP genotyping systems—namely, the Global Screening Array (GSA), Chinese Genotyping Array (CGA), Affymetrix array, and the 1240K capture panel—for haplogroup assignment. This work provides a reference for data comparison across different systems. MethodsWe extracted genotype data for the 4 Y-SNP panels from 30× whole-genome sequencing (WGS) data of 1 590 male samples from the 1000 Genomes Project. Additionally, GSA array genotype data from 384 relative pairs (spanning 1st- to 12th-degree relationships) from 109 Chinese Han families were collected. Haplogroup assignment was performed using Y-LineageTracker v1.3.0 software. We assessed the concordance and resolution of haplogroup assignments between the four Y-SNP panels and the WGS data. The consistency and resolution of haplogroup assignments were also evaluated for both the 1000 Genomes Project samples and the 109 family samples collected in this study. Furthermore, the impact of varying numbers of Y-SNPs on haplogroup assignment was examined. ResultsThe GSA and CGA panels demonstrated superior resolution and discrimination of haplogroup subclades compared with the other two panels. The haplogroup assignments from the GSA, CGA, and 1240K panels showed high concordance with WGS data, with consistency rates exceeding 88.70%, whereas the Affymetrix platform exhibited a significantly lower consistency rate of 61.89%. Specifically, the GSA and CGA panels consistently demonstrated superior performance compared with the other two panels in the assignment of haplogroups O-M175 and H-L901, achieving complete concordance (100%) for both haplogroups. In contrast, the Affymetrix panel erroneously assigned all individuals belonging to haplogroup O-M175 to haplogroup K2-M526. Furthermore, its accuracy for haplogroup H-L901 was exceedingly low, at merely 1.41%. This poor performance was characterized by the misassignment of 98.59% of H-L901 samples—specifically, 1.41% to J-M304 and a predominant 97.18% to F-M89. For haplogroup R-M207, all four panels exhibited uniformly high levels of consistency, with concordance values exceeding 94.00%. Notably, for haplogroup E-M96, the 1240K and Affymetrix panels outperformed the GSA and CGA panels in terms of concordance, representing the first instance in which these two panels surpassed the latter. Conversely, for haplogroups J-M304, Q-M242, and I-M170, all 4 panels showed relatively elevated misclassification rates, with the Affymetrix array demonstrating the poorest overall performance. None of the four panels showed any discordant haplogroup assignments among the familial relative pairs analyzed. A positive correlation was observed between the number of Y-SNPs (ranging from 1 000 to 10 000) and classification consistency; however, classification consistency plateaued when the number of Y-SNPs exceeded 10 000. Furthermore, a random sampling analysis conducted on the GSA and CGA panels demonstrated that the haplogroup misclassification rate exhibited negligible fluctuation across the Y-SNP range of 500 to 1 000. Conversely, a marked enhancement in classification consistency was observed as the number of markers increased from 1 000 to 5 000, ultimately reaching a plateau within the interval of 5 000 to 8 000 markers. ConclusionThese findings indicate that the GSA and CGA panels provide high resolution and concordance, delivering reliable Y-haplogroup assignment for forensic investigations.
4.Stem cell exosomes and biomaterial-assisted exosomes in bone defect repair
Nian LIU ; Xinyue DONG ; Songpeng WANG ; Yingjiang XU ; Xiaoming ZHANG
Chinese Journal of Tissue Engineering Research 2026;30(1):175-183
BACKGROUND:A large number of studies have demonstrated that stem cell exosomes play an important role in the repair of bone defects,either directly as carriers for loading other small molecules or surface modifications,or by binding to biomaterials to promote the repair and regeneration of bone tissue.OBJECTIVE:To summarize the osteogenic mechanisms of stem cell exosomes from different sources and their research progress in bone defect repair.METHODS:Chinese search terms"stem cell,exosome,bone,biomaterial,carrier,bioceramic,polymer,metal,hydrogel,engineered exosome"were used to search CNKI.English search terms"stem cell,exosome,bone defect,biomaterial,carrier,bioceramic,ploymer,metal material,hydrogel,engineering exosome"were used to search PubMed database.According to the inclusion and exclusion criteria,77 relevant articles were finally included for summary.RESULTS AND CONCLUSION:Exosomes from stem cells of different origins can promote osteoblast proliferation and differentiation,promote angiogenesis,and regulate osteoclast activity and macrophage phenotype to promote bone formation and bone mineralization.In addition,many achievements of exosomes in the field of bone defect repair were described from two aspects:biomaterial-assisted exosomes and engineered exosomes.However,the current research on stem cell exosomes in bone tissue engineering is still insufficient,and most of these studies are limited to small animal models,while the treatment of bone defects in large animals,including humans,will be more complex,which will also become a major challenge for the treatment of bone defects.This will also be a great challenge in the dissemination of exosome therapy.
5.Stem cell exosomes and biomaterial-assisted exosomes in bone defect repair
Nian LIU ; Xinyue DONG ; Songpeng WANG ; Yingjiang XU ; Xiaoming ZHANG
Chinese Journal of Tissue Engineering Research 2026;30(1):175-183
BACKGROUND:A large number of studies have demonstrated that stem cell exosomes play an important role in the repair of bone defects,either directly as carriers for loading other small molecules or surface modifications,or by binding to biomaterials to promote the repair and regeneration of bone tissue.OBJECTIVE:To summarize the osteogenic mechanisms of stem cell exosomes from different sources and their research progress in bone defect repair.METHODS:Chinese search terms"stem cell,exosome,bone,biomaterial,carrier,bioceramic,polymer,metal,hydrogel,engineered exosome"were used to search CNKI.English search terms"stem cell,exosome,bone defect,biomaterial,carrier,bioceramic,ploymer,metal material,hydrogel,engineering exosome"were used to search PubMed database.According to the inclusion and exclusion criteria,77 relevant articles were finally included for summary.RESULTS AND CONCLUSION:Exosomes from stem cells of different origins can promote osteoblast proliferation and differentiation,promote angiogenesis,and regulate osteoclast activity and macrophage phenotype to promote bone formation and bone mineralization.In addition,many achievements of exosomes in the field of bone defect repair were described from two aspects:biomaterial-assisted exosomes and engineered exosomes.However,the current research on stem cell exosomes in bone tissue engineering is still insufficient,and most of these studies are limited to small animal models,while the treatment of bone defects in large animals,including humans,will be more complex,which will also become a major challenge for the treatment of bone defects.This will also be a great challenge in the dissemination of exosome therapy.
6.The epidemiological characteristics and spatial aggregation of typhus in Shaanxi Province from 2005 to 2023
Lu-qian ZHANG ; Shao-qi NING ; Yun-peng NIAN ; Shu WANG ; Xin-xin LI
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):19-24
Objective To investigate the epidemiological characteristics and changing trend of typhus in Shaanxi Province from 2005 to 2023 to provide a scientific basis for its prevention and control. Methods Excel 2007, SPSS 25.0, Joinpoint 4.9.1.0, and Geoda 1.6 were used for data collection and statistical analysis. Super Map was used for data visualization to describe the changing characteristics of the disease. Results A total of 394 typhus cases were reported in Shaanxi Province from 2005 to 2023. The average annual incidence of typhus was 0.054/100 000, showing a dynamic fluctuation trend(AAPC=-3.3, t=-0.3, P>0.05). The cases were mainly concentrated in Baoji, Hanzhong and Xi′an, accounting for 78.68%. The incidence peak was from May to October, accounting for 64.21% of annual incidence. The epidemic season was from May to October and December. The incidence of the disease was concentrated in the 40-69 age group, accounting for 58.88%, and the sex was 1.07:1. The main occupation was farmers, accounting for 72.08%. The median time from onset to diagnosis was 7 days. Global spatial autocorrelation analysis showed that there were significant spatial autocorrelations in 11 years from 2005 to 2023(P<0.05). Local spatial autocorrelation analysis detected a total of 43“high-high”clustering areas, mainly concentrated in Baoji City. Conclusions The overall incidence of typhus in Shaanxi Province showed a dynamic fluctuation trend, with notable seasonal and regional aggregation. The incidence of typhus was higher in middle-aged and elderly people in rural areas. Surveillance should be strengthened in typhus endemic areas in summer and autumn, and health education should be conducted for key population to form good health habits and reduce the incidence of typhus.
7.Development and validation of a blood-based differential diagnosis model for pulmonary tuberculosis and community-acquired pneumonia
Xiaolan SU ; Rui ZHANG ; Zeqing YANG ; Xinrui WANG ; Ziyu BI ; Nian LIU ; Yunyan HAN ; Qi REN
Acta Universitatis Medicinalis Anhui 2026;61(6):1143-1150
ObjectiveTo develop and validate a diagnostic prediction model for differentiating pulmonary tuberculosis from community-acquired pneumonia based on routine blood parameters. MethodsA total of 642 patients with pulmonary tuberculosis and 503 patients with community-acquired pneumonia were retrospectively enrolled from the Seventh Hospital of Tangshan. They were randomly divided into a training set and an internal validation set at a 7∶3 ratio. Additionally, 218 patients from the 981st Hospital were independently included as an external validation set. The Boruta algorithm and recursive feature elimination were employed to select predictors from 82 blood parameters, sex, and age. A multivariate Logistic regression model was established and evaluated using receiver operating characteristic (ROC) curves, calibration curves, and decision curve analysis. ResultsThe final model incorporated eight predictors, namely uric acid, urea nitrogen, alkaline phosphatase, monoamine oxidase, alanine aminotransferase, glutathione, neutrophil percentage, and age. The model achieved areas under the curve (AUCs) of 0.800 (95%CI: 0.769-0.830), 0.787 (95%CI: 0.738-0.836), and 0.736 (95%CI: 0.667-0.835) in the training, internal validation, and external validation sets, respectively. The model demonstrated good calibration, and decision curve analysis showed clinical net benefit within the threshold probability range of 10%-80%. ConclusionThe developed model exhibits good discriminative ability and clinical utility, serving as an effective early screening tool for primary healthcare institutions.
8.Epidemiological investigation of an outbreak of acute gastroenteritis caused by GⅡ norovirus at a vocational and technical school
ZHANG Hui ; NIAN Yunpeng ; LI Hua ; ZHANG Leile ; LAN Ning ; LI Xiaohu
Journal of Preventive Medicine 2025;37(9):917-921
Objective:
To investigate an outbreak of acute gastroenteritis at a vocational and technical school in Shaanxi Province in 2024, ao as to provide the reference for the handling of school outbreaks.
Methods:
The conducted case searches, individual case investigations, and on-site hygienic investigations were established in accordance with the Guidelines on outbreak investigation, prevention and control of Norovirus infection (2015). The potential risk factors were analyzed by case-control study. Anal swab samples from cases and all canteen staff, as well as environmental swab samples were collected to detect common intestinal pathogens. All reserved food samples in canteen were collected to test for common pathogenic bacteria.
Results:
From October 26 to November 5, 2024, a cumulative total of 53 cases were reported, with an attack rate of 1.47%. The main clinical symptoms included vomiting (83.02%), abdominal pain (56.60%), diarrhea (30.19%), and fever (26.42%). The epidemic curve suggested an intermittent common-source outbreak, with no obvious clustering characteristics in terms of the population and spatial distribution of cases. The case-control analysis revealed that having dinner at the rice-with-dishes-on-top stall on the first floor of the canteen on October 28 was a risk factor for illness (OR=11.025, 95%CI: 2.186-55.601). GⅡ norovirus was detected as positive in anal swab samples from 6 cases and 2 asymptomatic infected canteen staff, as well as in 3 environmental swab samples from the rice-with-dishes-on-top stall. The test results for common pathogenic bacteria in the reserved food samples were all negative.
Conclusions
This outbreak was caused by an acute gastroenteritis epidemic induced by GⅡ norovirus infection, with a transmission pattern consistent with an intermittent homologous outbreak. The possible source of infection was asymptomatic infected canteen staff mainly through foodborne trasmission, and having meals at the rice-with-dishes-on-top stall was the primary risk factor for this outbreak.
9.Interpretation and Examples:Key Updates in CONSORT 2025
Zelei DAI ; Renjie ZHAO ; Kefan LI ; Yonggang ZHANG ; Nian LI ; Wenjie YANG ; Lei LIU ; Lingmin CHEN
Journal of Sichuan University (Medical Sciences) 2025;56(3):678-685
Standardized clinical trial reporting is crucial for ensuring the scientific validity,reproducibility,and clinical translational value of reported results.The Consolidated Standards of Reporting Trials(CONSORT)statement,an internationally recognized guideline for randomized controlled trials(RCTs),has become an important reference standard for writing research papers in medicine since the 2010 version of CONSORT was published.With advancements in scientific research methodologies and the emergence of new forms of clinical trials,the CONSORT working group released an updated version in April 2025,published in journals such as The BMJ.Herein,we provide a systematic interpretation of the core revisions of CONSORT 2025,as well as a comparison with CONSORT 2010 to highlight the key differences.By providing practical,example-based recommendations,we aim to help domestic researchers apply the new guidelines efficiently,thereby improving the quality of clinical trial reports authored by domestic researchers.
10.Interpretation and Examples:Key Updates in SPIRIT 2025 Statement
Zelei DAI ; Renjie ZHAO ; Kefan LI ; Yonggang ZHANG ; Nian LI ; Wenjie YANG ; Lei LIU ; Lingmin CHEN
Journal of Sichuan University (Medical Sciences) 2025;56(3):686-696
A high-quality clinical trial protocol is the cornerstone for ensuring the scientific integrity and ethical compliance of a study.The Standard Protocol Items:Recommendations for Interventional Trials(SPIRIT)has become the international benchmark for developing clinical trial protocols since its release in 2013.To adapt to the developing trends of open science and patient-centered principles,the SPIRIT group completed a comprehensive update in 2025.While retaining its core structure,this updated guideline introduces a new open science module and incorporates several new elements,including patient and public involvement,trial monitoring,and data sharing,alongside substantial revisions of five pre-existing items.In this article,we critically examine the core revisions in SPIRIT 2025 and,through analysis of representative case studies,illustrate the practical application of the new reporting guideline in drafting trial protocols.Our goal is to to provide Chinese researchers with a valuable reference for understanding and implementing this new reporting guideline,thereby enhancing the quality and rigor of clinical trial protocols developed in the country.


Result Analysis
Print
Save
E-mail