1.Study on assessment methods for acetabular cup size in total hip arthroplasty.
Jinzi WANG ; Wenju CHANG ; Pei ZHANG ; Xiang LI ; Yong ZHANG ; Shuoshuo ZHANG ; Hai DING
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):163-167
OBJECTIVE:
To evaluate precise assessment methods for predicting the optimal acetabular cup size in total hip arthroplasty (THA).
METHODS:
A clinical data of 73 patients (80 hips) who underwent primary THA between December 2022 and July 2024 and met the inclusion criteria was analyzed. There were 39 males and 34 females with an average age of 66.3 years (range, 56-78 years). Among them, 66 cases were unilateral THA and 7 were bilateral THAs. There were 29 patients (34 hips) of osteoarthritis, 35 patients (35 hips) of femoral neck fractures, and 9 patients (11 hips) of osteonecrosis of the femoral head. Based on anteroposterior pelvic X-ray films, three methods were employed to predict acetabular cup size, including preoperative template planning, radiographic femoral head diameter (FHD) measurement, and intraoperative FHD measurement. The predicted acetabular cup sizes from these methods were compared with the actual implanted sizes.
RESULTS:
The predicted acetabular cup sizes using the preoperative template planning, radiographic FHD measurement, and intraoperative FHD measurement were (51.25±2.81), (49.72±3.11), and (49.90±2.74) mm, respectively, compared to the actual implanted cup size of (50.57±2.74) mm, with no significant difference ( P>0.05). Regarding agreement with the actual implanted cup size, the preoperative template planning achieved exact matches in 35 hips (43.75%), one-size deviation in 41 hips (51.25%), and two-size deviations in 4 hips (5%); the radiographic FHD measurement achieved exact matches in 12 hips (15%), one-size deviation in 57 hips (71.25%), and two-size deviations in 11 hips (13.75%); and the intraoperative FHD measurement achieved exact matches in 26 hips (32.5%), one-size deviation in 52 hips (65%), and two-size deviations in 2 hips (2.5%). There were significant differences in agreement distributions between the three methods and the actual implanted cup sizes ( H=18.579, P<0.001).
CONCLUSION
The intraoperative FHD measurement, as a simple, cost-effective, and accurate method, effectively guides acetabular cup selection, reduces the risk of prosthesis wear, enhances postoperative joint stability.
Humans
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Male
;
Female
;
Middle Aged
;
Acetabulum/diagnostic imaging*
;
Aged
;
Hip Prosthesis
;
Prosthesis Design
;
Femur Head/surgery*
;
Osteoarthritis, Hip/surgery*
;
Radiography
;
Femoral Neck Fractures/surgery*
;
Femur Head Necrosis/surgery*
2.Reconstruction of phonatory function using a tubular free flap from upper-lateral upper arm after near-total laryngectomy.
Liu YANG ; Yitao ZHENG ; Wen LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):209-214
OBJECTIVE:
To explore the feasibility of reconstruction of phonatory function by using a tubular free flap from upper-lateral upper arm to repair the laryngotracheal circumferential defect after near-total laryngectomy for laryngeal cancer.
METHODS:
A retrospective study was conducted on 7 patients who underwent near-total laryngectomy between June 2021 and October 2023, aged from 48 to 70 years (median, 59 years), 6 males and 1 female. The disease duration ranged from 1 to 11 months, with a median of 6 months. Pathological diagnosis of preoperative biopsy was squamous cell carcinoma. Tumor classification: glottic type in 5 cases, supraglottic type in 1 case, transglottic type in 1 case; TNM staging: T 4N 0M 0 in 6 cases, T 4N 2M 0 in 1 case; American Joint Committee on Cancer (AJCC) staging in 2017 was stage Ⅳ. Preoperative MRI angiography of upper arm was performed to investigate the blood supply in the upper and lateral regions of the upper arm. After near-total laryngectomy and bilateral neck lymph node dissection, the area of the laryngotracheal defect was measured. A free flap measuring 7.0 cm×5.0 cm to 8.0 cm×7.0 cm was harvested from the upper-lateral upper arm, rolled into a tube shape, and connected between the stump of the cervical trachea in the neck root and that of the epiglottis at the tongue base. Four patients received adjuvant radiochemotherapy, 1 patient received radiochemotherapy and targeted therapy, 2 patients adopted no further adjuvant treatment.
RESULTS:
All 7 patients were followed-up 1-2 years (mean, 1 year and 3 months). Four patients had primary wound healing, 2 patients had minor pharyngeal fistulas that healed after dressing change, 1 patient experienced pharyngeal fistula because of flap necrosis and the wound still healed without secondary surgery. All patients took food orally within 1 month after operation, and the tracheal cannula was retained. Six patients with survived flap gradually adapted to their new pronunciation mode and obtained satisfactory phonatory function from 15 days to 2 months after operation. Four patients had slight aspiration after operation. Till the end of the follow-up, all patients survived and no local recurrence or distant metastasis had been observed. The motor function of the upper arm was not affected, only partial sensory loss occurred in the area near the incision. The scar of the incision could be covered by the short sleeve so as to obtain a better aesthetic effect.
CONCLUSION
Using a tubular free flap from upper-lateral upper arm to repair the laryngotracheal circumferential defect after near-total laryngectomy for laryngeal cancer can achieve satisfactory phonatory restoration while preserve the motor function and aesthetics of the donor site.
Humans
;
Laryngectomy/methods*
;
Male
;
Middle Aged
;
Female
;
Laryngeal Neoplasms/surgery*
;
Aged
;
Free Tissue Flaps
;
Retrospective Studies
;
Plastic Surgery Procedures/methods*
;
Carcinoma, Squamous Cell/surgery*
;
Phonation
;
Arm/surgery*
;
Neck Dissection
3.Finite element analysis of adding one transverse screw for Pauwels type Ⅲ femoral neck fractures.
Luyao MA ; Xueao SUN ; Qingjun TAN ; Yanping LAN ; Xiaohu WANG ; Yunsheng YIN ; Jinhui MA
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):584-591
OBJECTIVE:
To investigate whether adding 1 transverse screw (TS) to the triangular parallel cannulated screw (TPCS) fixation has a mechanical stability advantage for Pauwels type Ⅲ femoral neck fractures by conducting finite element analysis on four internal fixation methods.
METHODS:
Based on CT data of a healthy adult male volunteer's femur, three Pauwels type Ⅲ femoral neck fracture models (Pauwels angle 70°, Pauwels angle 80°, and Pauwels angle 70° combined with bone defect) were constructed using Mimics 21.0 software and SolidWorks 2017 software. Four different internal fixation models were built at the same time, including TPCS, TPCS+TS, three cross screws (TCS), and TPCS+medial buttress plate (MBP). The mechanical stability of different models under the same load was compared by finite element analysis.
RESULTS:
The femoral model established in this study exhibited a maximum stress of 28.62 MPa, with relatively higher stress concentrated in the femoral neck. These findings were comparable to previous studies, indicating that the constructed femoral finite element model was correct. The maximum stress of internal fixation in finite element analysis showed that TCS was the lowest and TPCS+MBP was the highest in Pauwels angle 70° and 80° models, while TPCS+TS was the lowest and TCS was the highest in Pauwels angle 70° combined with bone defect model. The maximum displacement of internal fixation in each fracture model was located at the top of the femoral head, with TCS having the highest maximum displacement of the femur. The maximum stress of fracture surface in finite element analysis showed that TCS was the lowest and TPCS was the highest in the Pauwels angle 70° model, while TPCS+MBP was the lowest and TPCS/TCS were the highest in the Pauwels angle 80° model and the Pauwels angle 70° combined with bone defect model, respectively. The maximum displacement of fracture surfece analysis showed that TPCS+MBP was the lowest and TCS was the highest in Pauwels angle 70° and 80° models, while TPCS+TS was the lowest and TCS was the highest in Pauwels angle 70° combined with bone defect model.
CONCLUSION
For Pauwels type Ⅲ femoral neck fractures, the biomechanical stability of TPCS+TS was superior to that of TPCS alone and TCS, but it has not yet reached the level of TPCS+MBP.
Finite Element Analysis
;
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Bone Plates
;
Stress, Mechanical
;
Biomechanical Phenomena
;
Tomography, X-Ray Computed
;
Adult
;
Femur Neck/surgery*
4.Analysis of effectiveness of Holosight robot navigation-assisted percutaneous cannulated screw fixation in treatment of femoral neck fractures.
Weizhen XU ; Zhenqi DING ; Hui LIU ; Jinhui ZHANG ; Yuanfei XIONG ; Jin WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):673-679
OBJECTIVE:
To investigate the effectiveness of Holosight robotic navigation-assisted percutaneous cannulated screw fixation for femoral neck fractures.
METHODS:
A retrospective analysis was conducted on 65 patients with femoral neck fractures treated with cannulated screw fixation between January 2022 and February 2024. Among them, 31 patients underwent robotic navigation-assisted screw placement (navigation group), while 34 underwent conventional freehand percutaneous screw fixation (freehand group). Baseline characteristics, including age, gender, fracture side, injury mechanism, Garden classification, Pauwels classification, and time from injury to operation, showed no significant differences between the two groups ( P>0.05). The operation time, intraoperative blood loss, fluoroscopy frequency, fracture healing time, and complications were recorded and compared, and hip function was evaluated by Harris score at last follow-up. Postoperative anteroposterior and lateral hip X-ray films were taken to assess screw distribution accuracy, including deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex.
RESULTS:
No significant difference was observed in operation time between the two groups ( P>0.05). However, the navigation group demonstrated superior outcomes in intraoperative blood loss, fluoroscopy frequency, deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex ( P<0.05). No incision infections or deep vein thrombosis occurred. All patients were followed up 12-18 months (mean, 16 months). In the freehand group, 1 case suffered from cannulated screw dislodgement and nonunion secondary to osteonecrosis of femoral head at 1 year after operation, 1 case suffered from screw penetration secondary to osteonecrosis of femoral head at 5 months after operation; and 1 case suffered from nonunion secondary to osteonecrosis of femoral head at 6 months after operation in the navigation group. All the 3 patients underwent internal fixators removal and total hip arthroplasty. There was no significant difference in the incidence of complications between the two groups ( P>0.05). The fracture healing time and hip Harris score at last follow-up in the navigation group were significantly better than those in the freehand group ( P<0.05).
CONCLUSION
Compared to freehand percutaneous screw fixation, Holosight robotic navigation-assisted cannulated screw fixation for femoral neck fractures achieves higher precision, reduced intraoperative radiation exposure, smaller incisions, and superior postoperative hip function recovery.
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Middle Aged
;
Aged
;
Adult
;
Treatment Outcome
;
Operative Time
;
Fracture Healing
;
Surgery, Computer-Assisted/methods*
;
Fluoroscopy
5.Short-to-medium-term clinical efficacy of total hip arthroplasty with Pinnacle ES constrained liner in the treatment of femoral neck fractures associated with lower limb neuromuscular disorders.
Can-Feng WANG ; Xiao-Qing WANG ; Lei HAN ; Yun-Gen HU ; Tuo WANG
China Journal of Orthopaedics and Traumatology 2025;38(11):1151-1155
OBJECTIVE:
To investigate the short-to-medium-term clinical efficacy of total hip arthroplasty(THA) with Pinnacle ES constrained liner in the treatment of femoral neck fractures(FNF) associated with lower limb neuromuscular disorders.
METHODS:
A retrospective analysis was conducted on 16 patients who underwent primary THA using Pinnacle ES constrained liner for FNF with lower limb neuromuscular disorders and had complete follow-up data, treated between January 2020 and January 2023. There were 7 males and 9 females, with a mean age of (68.42±3.58) years old ranging from 61 to 75 years old. Among them, 10 cases had left-sided fractures and 6 had right-sided fractures;based on the Garden classification, 11 cases were type Ⅲ and 5 cases were type Ⅳ. The affected limbs were complicated with sequelae of poliomyelitis (2 cases), Parkinson's disease (2 cases), and sequelae of cerebral infarction (12 cases). All operations were performed via a posterolateral approach. Prosthesis position was evaluated using imaging data. Hip function was assessed by the Harris hip score(HHS) and Merle D'Aubigne hip score. During the follow-up period, the occurrence of complications such as prosthetic dislocation, loosening, and infection was recorded.
RESULTS:
One patient died of advanced tumor 2 years after surgery, and the remaining 15 patients were followed up for 24 to 64 months with a mean of (34.8±5.5) months. The operation time ranged from 50 to 90 minutes with a mean of (75.56±8.15) minutes, and the blood loss ranged from 150 to 200 ml with a mean of (170.32±12.56) ml. All patients achieved primary wound healing after surgery. Intraoperatively, femoral calcar splitting occurred in 2 cases, which were treated with titanium cable binding;no neurovascular injuries were observed in any case. The mean HHS increased from (18.95±2.25) preoperatively to (88.02±2.42) at the last follow-up, and the mean Merle D'Aubigne Score increased from (3.05±0.06) preoperatively to (16.65±0.93) at the last follow-up. Postoperative follow-up X-rays showed good prosthetic position, and no complications such as dislocation, prosthetic loosening, periprosthetic fracture, or deep infection occurred during the follow-up period.
CONCLUSION
Total hip arthroplasty with Pinnacle ES constrained liner is effective in the treatment of femoral neck fractures associated with lower limb neuromuscular disorders. It can significantly improve hip function, reduce the postoperative prosthetic dislocation rate, provide good initial stability, and achieve satisfactory short-to-medium-term clinical efficacy.
Humans
;
Male
;
Female
;
Middle Aged
;
Aged
;
Arthroplasty, Replacement, Hip/methods*
;
Femoral Neck Fractures/complications*
;
Retrospective Studies
;
Neuromuscular Diseases/surgery*
;
Lower Extremity
;
Treatment Outcome
6.Shrapnel in carotid sheath: A rare penetrating neck injury.
Muhammad REHAN ; Savera ANWAR ; Hadia WALI ; Aysha NOOR ; Omer EHSAN ; Shayan Shahid ANSARI
Chinese Journal of Traumatology 2025;28(3):231-234
Injuries deeper than the platysma are considered as penetrating neck injuries, constituting approximately 5% - 10% of all trauma. Many vital organs are at risk from a penetrating neck injury. These injuries in zone 1 have the highest mortality, because the injuries are close to the vital organs and difficult to access surgically. A 41-year-old male, a car mechanic by profession, presented to the emergency department with a penetrating neck injury on the right side. CT scan demonstrated a metallic foreign body in zone 1 between the right internal jugular vein and the common carotid artery. The patient was asymptomatic, and the foreign body was removed surgically. This case shows a rare presentation of a penetrating neck injury with a foreign body located in zone 1, where no vital internal structure was injured. As of now, no previous case report has been identified on such presentation. Thus, it will provide a valuable addition to the pre-existing literature.
Humans
;
Male
;
Adult
;
Neck Injuries/diagnostic imaging*
;
Wounds, Penetrating/diagnostic imaging*
;
Foreign Bodies/diagnostic imaging*
;
Jugular Veins
;
Tomography, X-Ray Computed
;
Carotid Artery Injuries/surgery*
;
Carotid Artery, Common
7.Sparing piriformis and internus repairing externus vs. other conventional approaches for hip hemiarthroplasty: A report of early outcomes from a single UK trauma unit.
Michael APOSTOLIDES ; William THOMAS ; Darren LEONG ; Bogdan ROBU ; Nimesh PATEL
Chinese Journal of Traumatology 2025;28(5):324-329
PURPOSE:
Over 30,000 hip hemiarthroplasties for neck of femur fractures are performed annually in the United Kingdom (UK). The national recommendation is via the lateral approach, to reduce the risk of dislocation, with the potential expense of reduced function and mobility post-operatively. Muscle-sparing approaches, such as SPAIRE (sparing piriformis and internus repairing externus), have been invented to address the issue of dislocation.
METHODS:
We performed a retrospective data collection at a single center with a high annual volume of hip hemiarthroplasties over 12 months. All patients who had hip hemiarthroplasty as their primary treatment were included. Patients who passed away and were non-ambulant before their surgery were excluded from the study. Our primary outcome was the dislocation rate and secondary outcomes were the time to mobilization after surgery and the duration of surgery. Statistical analysis was performed using XLSTAT software.
RESULTS:
We identified 194 cases, and these were divided into 3 groups based on the surgical approach: SPAIRE (n = 43), lateral (n = 97), and posterior (n = 54). Groups had similar demographics and a minimum 3-month follow-up after surgery. There were no dislocations in the SPAIRE group, whereas the dislocation rate for the other 2 groups was 2.5% in the lateral and 9.1% in the posterior groups at 6 months post-surgery. There was an earlier return to mobility in the SPAIRE (1.4 day) compared to the 2 other groups ( 2 days and 2.6 days). Average surgical times were very similar among all 3 groups (74 min vs. 79 min vs. 71 min).
CONCLUSION
The SPAIRE approach seems to be safe and provides a low risk of dislocation and good post-operative function for patients undergoing hip hemiarthroplasties.
Humans
;
Hemiarthroplasty/methods*
;
Retrospective Studies
;
Female
;
Male
;
Aged
;
United Kingdom
;
Femoral Neck Fractures/surgery*
;
Middle Aged
;
Treatment Outcome
;
Aged, 80 and over
;
Arthroplasty, Replacement, Hip/methods*
;
Trauma Centers
;
Hip Dislocation/prevention & control*
;
Postoperative Complications/prevention & control*
8.Left sided sternocleidomastoid interosseous intravascular papillary endothelial hyperplasia: A case report.
Xiaodi XIAO ; Youchen XIA ; Jianying LIU ; Peng FU
Journal of Peking University(Health Sciences) 2025;57(5):1002-1004
Intravascular papillary endothelial hyperplasia (IPEH), also known as Masson tumor, is a rare vascular benign tumor of blood vessels. It may occur in any part of the body, especially the deep dermis and subcutaneous tissue of the head, neck, fingers and trunk. The imaging and histopathology of IPEH are similar to hemangiosarcoma, especially in the case of active vascular endothelial hyperplasia. IPEH is a reactive proliferative lesion of vascular intima. The etiology is still unclear. After some studies showed that IPEH was a benign lesion, few reports on the etiology of it were reported. IPEH is usually limited to the thrombotic vessels or lumens of vascular malformations, usually accompanied by a clear history of trauma. IPEH usually does not cause any symptoms. It looks like a slow-growing lump. Some cases have been reported with pain and swelling. Although IPEH is relatively rare, its accurate diagnosis is crucial because it may be similar to malignant angiogenic lesions in clinical practice. There were few reports of cases related to intravascular papillary endothelial hyperplasia located in the sternocleidomastoid muscle after reviewing the domestic and foreign literature in recent 10 years. This case reports that a young male, who was admitted to the hospital one month after finding a subcutaneous tumor in the left neck. After admittance, relevant preoperative examinations were completed. After multi-disciplinary discussion and elimination of surgical contraindications, a specific surgical plan was formulated. The tumor was removed under local anesthesia on the second day after admission. During the operation, it was found that the tumor was located between the sternocleidomastoid muscle bundles, and it was sent for pathologic examination. Paraffin section pathology was reported after operation. Histological examination showed that the morphology was consistent with vascular endothelial papillary hyperplasia. There were no related surgical complications and recurrence in the 3-month follow-up. The purpose of this paper is to provide clinicians with a certain understanding of this rare disease through the report of this case of IPEH, and to identify it in later clinical work, and at the same time, to avoid confusion with malignant diseases, such as hemangiosarcoma, leading to unnecessary treatment and increase the cost of treatment.
Humans
;
Male
;
Endothelium, Vascular/pathology*
;
Hemangioendothelioma/surgery*
;
Hyperplasia/pathology*
;
Neck Muscles/surgery*
;
Vascular Neoplasms/pathology*
9.Current application and future development trends of robotic head and neck surgery.
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(11):993-1000
Surgical robots, leveraging a 10-fold magnified field of view, 3D visualization, and stable robotic arms, address the limitations of traditional 2D endoscopic surgery. They have been applied in multiple surgical fields, with remarkable potential in head and neck surgery. This article elaborates on their applications in surgeries for laryngeal cancer (supraglottic and glottic types), pharyngeal tumors (oropharyngeal cancer, recurrent nasopharyngeal carcinoma, etc.), thyroid tumors, and neck cysts. Combined with multi-center research data, it confirms the advantages of surgical robots in minimally invasive procedures and functional preservation. Additionally, the article looks ahead to the future applications of single-port robots, VR/AR, AI, domestically produced specialized robots, and 5G-enabled remote surgery. The development of robotic surgery is closely intertwined with advancements in science and technology, and it will undoubtedly drive the diagnosis and treatment of head and neck tumors into the "era of precise minimally invasive care".
Humans
;
Robotic Surgical Procedures/trends*
;
Head and Neck Neoplasms/surgery*
10.Clinical application of robotic lateral lymph node dissection via BABA for thyroid cancer.
Yan FANG ; Kai YUE ; Yuansheng DUAN ; Hao LI ; Xudong WANG
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(11):1038-1043
Objective:To investigate the clinical efficacy of robotic surgery via the bilateral axillo-breast approach(BABA) in lateral lymph node dissection for papillary thyroid carcinoma(PTC). Methods:Clinicopathological records of 324 PTC patients receiving unilateral neck dissection in Tianjin Medical University Cancer Institute and Hospital from December 2020 to November 2024 were retrospectively analyzed. Of these patients, 108 underwent robotic surgery via BABA(robotic group), while the remaining patients underwent conventional open surgery(open group). The extent of lateral neck lymph node dissection included level Ⅱ, Ⅲ and Ⅳ. The differences in surgical indexes, postoperative complication rates and cosmetic outcomes of incisions were compared between two groups. Results:All study subjects completed the operation successfully, and there was no conversion in the robotic group. The average age of patients in the robotic group was lower than that in the open group, and the proportion of female patients was higher in the robotic group compared to the open group(P<0.05). Patients in the robotic group had a greater number of dissected lymph nodes in level ⅡB and higher cosmetic scores(P<0.05). There were no statistically significant differences between the two groups in the average dissection time of lateral cervical lymph nodes, the number of dissected lymph nodes and metastatic lymph nodes in level ⅡA, Ⅲ, and Ⅳ, average postoperative drainage volume, average postoperative hospital stay, and postoperative complication rates(P>0.05). Conclusion:The application of robotic surgical system via BABA in lateral neck lymph node dissection for PTC is safe and feasible, with superior advantages in level ⅡB dissection and better postoperative cosmetic outcomes.
Humans
;
Thyroid Neoplasms/surgery*
;
Robotic Surgical Procedures/methods*
;
Female
;
Retrospective Studies
;
Neck Dissection/methods*
;
Lymph Node Excision/methods*
;
Male
;
Thyroid Cancer, Papillary
;
Axilla/surgery*
;
Thyroidectomy/methods*
;
Breast/surgery*
;
Middle Aged
;
Adult
;
Lymph Nodes/surgery*
;
Treatment Outcome

Result Analysis
Print
Save
E-mail